Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹6.3 L
EMD Value
₹15,831
Closing Date
28 Mar 2025, 2:00 pmClosed
Assistant Executive Engineer
PH Sub Division Pathanamthitta
DEPOSIT-Improvements to Mannumkal Water Supply Scheme- Phase II- Mannumkal Water Supply Phase II Improvements Work-General Civil Work
2025_KWA_754045_1
37(Rt)/2024-25/AEE/PH/PTA
Open Tender
Civil Works - Water Works
Item Rate
Pathanamthitta
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,400
₹15,831
16 May 2025
22 Mar 2025
29 Mar 2025
22 Mar 2025
28 Mar 2025
22 Mar 2025
Amount
Construction of Cement Concrete Tank as Aeration Water Tank & Supplying of Blower & Dual Media Filter Cum Multi Graded Filter for Iron Removal
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level
5.22.3:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelCold twisted bars
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
OD240641/2024-2025:Dual Media Filter (DMF), Multi Graded filter (MGF) : IRON REMOVAL PLANT Capable of Capacity 5000 LPH,FRP Vessel 3 nos Vessel size 18x65 inch Valve 50 NB multiport valve Media quartz sand, activated carbon, anthracite, mno2, purolite Pump 1.0 hp 1 no Dossing pump 1 no Pipe and fittings 1 lot (pvc and upvc) Pump 1.5 hp 1 no (To pump water from the well to the aeration tank) Starter and panel board 1 no Electrical fittings and cables 1 lot which ever is most suitable to the requirement
OD240643/2024-2025:Supplying and fixing AIR Blower Make A1 or AKASH Blower Capacity 10 m3 as per direction of departmental officer at site.
OD240644/2024-2025:Supply, installation, testing and commissioning of M.S pipe to complete the system between tank, pumps and water treatment unit, Diaphragm/Butterfly Valves, Chlorine Dosing Pump M.O.C : Kanakadhara, Working Pressure : 4BAR Material Construction –Wet Part : PVDF Dosing Chemical : Sodium Hypo chloric solution Concentration : 10%, Alum Dosing Pump M.O.C : Kanakadhara, Working Pressure : 4BAR Material Construction –Wet Part : PVDF Dosing Chemical : Alum
OD101398/2024-2025:Platform and shelter for Filter and necessary Control Panels
100.41.34:Supplying and fixing Rectangular C.I. manhole cover 455mm x 610mm with frame (low duty) charges including all cost, labour charges etc., complete.
Bidder Name
DENNY DANIEL
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1224037.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .