Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹21.4 L+₹66,147 (3.19%)Rejected-Finance H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹23.1 L+₹2.3 L (11.2%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
1 Nov 2022, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
PROVISION OF MS RAILING FROM MAIN GATE TO BUILDING NO. P-83 AT 24 CIVILIAN QTRS, PROVISION OF BALCONY RAILING, WINDOW GRILL AND SCOOTER SHED AT BUILDING NO. P-101, P-102 AND P-103, PROVISION OF VALLEY GUTTER FOR TIN ROOF OF BLDG NO. P-44 AND ADDN/ALT
2022_MES_510845_7
GE/CLT/ Of 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class E Cat a(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹44,000
Yes
10 Nov 2022
8 Oct 2022
3 Nov 2022
8 Oct 2022
1 Nov 2022
17 Oct 2022
Amount
Excavation in trenches n.exc. 1.5m wide and n.exc. 1.5m depth for foundation and getting out in loose/soft soil complete all as specified and as directed.
Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 cm as in soft/ loose soil complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where at a level n exc 1.5 m above the starting point in soils complete all as specified and directed.
M&L for cement concrete type D2 (1:4:8) (40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L brick work with sub class "B" old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L Mild steel framed work such as grills, gratings etc designed with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings framework of water tanks and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for preparing new steel and iron surfaces of any description over 10 CM width or girth and applying two coats of synthetic enamel paint of any tint over one coat of red oxide primer complete all as specified and directed.
M&L 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for cement concrete type B1, (1:2:4) (using 20mm graded crushed stone aggregate) as in coping including formwork (straight or curved) and finishing Complete all as specified and as directed.
M&L two coats of cement based paint over a coat of primer to newly plastered surfaces of wall including preparation surfaces complete all as specified and directed.
S&F Mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings framework of water tanks and similar work confirming to Fe-290 Gde E-165 in the existing walls and making good to disturbed area of Brickwork & concrete surface including plastering with two coats of white wash complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa and 150AZ as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coated GI based plain steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa and 150 AZ as in roof covering/cladding to wall, ridge, hips, valley gutters, drip and straight flashings (length and girth as fixed) etc fixed with self tapping screws complete all as specified and directed.
S&F mild steel work as in trusses, rafters, purlins etc, and the like made out of MS pipe, flat, angle or hollow sections conforming to Fe-410-W (Gde-E-250) quality-A incl all necessary cleats, gusset plates etc complete all as specified and directed.
M&L 100mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and pigment complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed.
S&F in repair PVC (SWR) bend any radius 110mm bore complete all as specified and directed.
S&F stack clamp of PVC with screws and securing ends of stays to wall and roof for 110mm dia bore pipe complete all as specified and directed.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed.
Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m soft soil , getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
M&L 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for three coats of white wash to newly plastered surfaces of walls including preparation of surfaces, complete all as specified and directed.
M&L Cement concrete type C2 (1:3:6) (40mm graded crushed stone aggregate) in foundations, post hole, filling and mass concrete etc complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed.
M&L 50mm thick PCC (1:3:6) type C-2 (Using 40mm graded crushed stone aggregate) as in plinth protection /hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed.
M&L for Machine cut pre polished Kota stone slab 18-20mm thick as in floor/ treads of steps (single piece) laid over and including 15mm thick screed in CM (1:6), set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cuttings, rubbing complete all as specified and directed.
S&F 0.50mm plain, galvanised, mild steel sheeting, in ridges, hips, vally gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as direcetd.
Supply and fixing DLP-U Galvnized iran adoptable trunking system size 50 x 200 mm, 1- compartment comprising of accessories like flexible cover, end caps, cable tie base, anggles, junctions and bus barsetc and any other required accessories as per site requirement and directed.
Supply and fixing DLP-U Galvnized iran adoptable trunking system size 50 x 150 mm, 1- compartment comprising of accessories like flexible cover, end caps, cable tie base, anggles, junctions and bus barsetc and any other required accessories as per site requirement and directed.
Supply and fixing DLP-U Galvnized iran adoptable trunking system size 50 x 100 mm, 1- compartment comprising of accessories like flexible cover, end caps, cable tie base, anggles, junctions and bus barsetc and any other required accessories as per site requirement and directed.
Supply and fixing DLP-U- Galvnized iran adoptable trunking system size 50 x 80 mm, complete of accessories like flexible cover, end caps, cable tie base, angles, junctions and bus bars etc and any other required accessories as per site requirement and directed.
Supply and fixing DLP-U- Galvnized iran adoptable trunking system size 50 x 50 mm, complete of accessories like flexible cover, end caps, cable tie base, angles, junctions and bus bars etc and any other required accessories as per site requirement and directed.
Supply and fixing DLP-U Galvnized iran adoptable trunking system size 32X12.5 mm, 1- compartment comprising of accessories like flexible cover, end caps, cable tie base,angles, junctions etc and any other required accessories as per site requirement and directed.
Supply and fixing DLP-U Galvnized iran adoptable trunking system as per MDS Lexic size 32X16 mm, 1- compartment comprising of accessories like flexible cover, end caps, cable tie base,angles, junctions etc and any other required accessories as per site requirement and directed.
Supply and fixing PVC Conduit Pipe 20mm on wall with clamps all as directed and specified.
Material and labour for point wiring with 1.5 sq mm PVC insulated, unsheathed stranded copper conductor cable (FRLS) single core 1100 volt grade in and including PVC casing caping medium grade 20mm dia or more ISI Marked concealed conduit and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface, including all necessary accessarries like metallic flush box, white cover plate with frame etc and 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS) as earth wire connected with main common earth dolly including complete all as specified and directed for the following :-"Material and labour for point wiring with 1.5 sq mm PVC insulated, unsheathed stranded copper conductor cable (FRLS) single core 1100 volt grade in and including PVC casing caping medium grade 20mm dia or more ISI Marked concealed conduit and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface, including all necessary accessarries like metallic flush box, white cover plate with frame etc and 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS) as earth wire connected with main common earth dolly including complete all as specified and directed for the following :- One light/fan/bell point controlled by one, one way switch complete all as specified and directed. Note :- (i) Cost of cutting chases of suitable girth where required on brick/ concrete surface and making good distrubed surface shall be deemed to be included in quoted rates. (ii) If the contractor fail to make good the distrubed surface of wall/ floor etc and do not match with the existing surface of wall/ floor to the entire satisfication of Engr-in-charge a recovery @ of Rs. 50 per RM will be made from payment due to the contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material and labour for point wiring with 4 sq mm PVC insulated, unsheathed stranded copper conductor cable (FRLS) single core 1100 volt grade in and including PVC casing caping medium grade 20mm dia accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface, including all necessary accessarries like metallic flush box, white cover plate with frame etc and 2.5 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS) as earth wire connected with main common earth dolly including complete all as specified and directed. Note :- (i) Cost of cutting chases of suitable girth where required on brick/ concrete surface and making good distrubed surface shall be deemed to be included in quoted rates. (ii) If the contractor fail to make good the distrubed surface of wall/ floor etc and do not match with the existing surface of wall/ floor to the entire satisfication of Engr-in-charge a recovery @ of Rs. 50 per RM will be made from payment due to the contractor. In case of any dispute the decision of accepting officer will be final and binding.
S&F switch piano flush type 05 Amps one way single pole 240 volts A C complete all as specified and directed.
S&F Poly carbonate isolated body ceiling rose three terminal complete all as specified and as directed.
S & F modular enclosure for geyser with two pole and earth plug socket complete with one, single pole MCB 20 Amps cap 240 Volts AC complete all as specified and as directed.
S & F PVC fresh air fan 240 volts Ac 50 Hz 250 mm sweep including louvers and cutting as required size and shape complete all as specified and as directed. (Make: Bajaj/Havells/Crompton)
S & F Metallic body exhaust fan 240 volts Ac 50 Hz 300 mm sweep including louvers and cutting as required size and shape complete all as specified and as directed. (Make: Bajaj/Havells/Crompton)
Supply and fixing MCB 5 to 32 Amp 'B' series 10 KA repturing capacity complete all as specified and as directed.
Supply and fixing MCB SPN 40 Amp 240 V AC 10 KA repturing capacity complete all as specified and as directed.
Supply and install electric water heater storage type geyser (ISI mared) 5 star rated inner container with Stainless steel 1500 watt of capacity 25 Ltr complete grouting on wall with suitable size of nut & bolts washer as srequired at site complete all as specified and as directed. (Make:Bajaj/Havells/Crompton)
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .