| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC HOUSE NO 6 18 WARD NO 05 HOUSING BOARD COLONY HANUMANGARH JN 335512 RAJ | HANUMANGARH | RAJASTHAN | 335512 | L1 | Accepted-AOC M/S R B Infra Builders is the Lowest Bidder, hence accepted | |
| 2 | L2₹47.9 L+₹6.0 L (14.4%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹50.3 L+₹8.5 L (20.2%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
26 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Nitish Pathak
GE (AF) Phalodi
ADDITIONAL/ALTERATION TO BUILDING P-82 (SHOPPING COMPLEX) AT AF STN PHALODI
2024_MES_686065_1
8662/A/E8
Open Tender
Civil Works
Item Rate
180 days
Air Force Station Phalodi
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE(AF) Phalodi
₹87,200
Yes
29 Jan 2025
28 Nov 2024
2 Jan 2025
28 Nov 2024
26 Dec 2024
12 Dec 2024
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisses complete all as specified and directed.
Dismantling of stone slab and tiles of any description or thickness in floors, etc. laid bedded and pointed in any mortar complete all as specified and directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces 350x250x7mm/ 450mm x 300mmx7 mm thick over and including 10 mm thick Screeding in CM (1:3) on fair faces of brick work or concrete surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L Non - skid joint free Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile, exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement mortar (1:6), for laying floor finishes complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base 20 mm thick in cement mortar (1:6), laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over 15 mm thick rendering in cement mortar (1:4), laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed.
Demolition cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 40 mm thick cement concrete flooring type B-0, (1:2:4) (using 12.5 mm graded stone aggregate) surfaces of concrete topping to be finished even and fair (without using extra cement) all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) fininshing the surfaces of concrete topping even and fair without using extra cement complete all as specified and directed.
S&F APP based polymeric membrane not less than 3 mm thick ,weighing not less than 3.5 kg/sqm, reinforced with fiber glass (weighing not less than 150 gm/sqm) and upper side of membrane thermally insulated with white mineral gravel finish, informly embedded during manufacturing process shall only be used. it shall be used by torch application, side overlap shall be 75 mm and the ends shall be 100 mm and all over laps shall be sealed by torch application including applying a coat of cold applied bitumen primer confirming IS :3384 @0.4 kg/Sqm. Note:- work shall be carried up to 2-3 stored building.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed. Note- work shall be carried out up to 2-3 stored bldg, contractor to quote rate accordingly.
M&L for providing, cement concrete type B 0, (1:2:4) using 12.5 mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges and padding in roof over complete all as specified and directed.
M&L for brushing neat cement slurry with 3 kg per sqm of cement complete all as specified and directed.
M&L for rendering 10mm thick Cement plaster (1:3) on fair faces of brick work or concrete surfaces on the roof etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description by cutting or without damage of structure not otherwise provided for complete all as specified and directed.
M&L for Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and directed.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F 0.63mm Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
M&L two coats of synthetic enamel paint (ordinary tint) on steel surfaces of any description over 10 cm width or girth, not otherwise described over a coat of red oxide primer including preparation of new steel surface complete all as specified and directed.
M&L one coat of synthetic enamel paint (ordinary tint) on steel surfaces of any description over 10 cm width or girth, not otherwise described including preparation of old steel surfaces complete all as specified and directed .
Taking down cement plaster or cement lime plaster on brick, stone or PCC walls etc. including raking out joints hacking for key scrubbing down with water etc all complete all as specified and directed.
M&L for Rendering 5 mm thick in CM (1:4) over 10 mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces finished even & smooth (without using extra cement) second layer mixed with WPC/water proofing chemical as per manufacturer's instruction complete all as specified and directed. Note:- WPC shall be measured and paid saperately.
M&L rendering 10 mm thick in CM (1:6) on other than fair face stone masonry surfaces or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L 5mm thick rendering in cement mortar (1:3) to ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L three coats of white wash to undecorated ceiling surfaces including preparation of new surfaces complete all as specified and directed.
M&L one coat of white wash to old decorated plastered surfaces of ceilling including preparation of surfaces complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper of approved shade/tint over a coat of cement primer on walls all as specified & directed.
M&L for complete removal of existing treatment on walls and applying two coats of oil bound distemper white or tinted over a coat of cement primer over 3mm thick wall care putty on wall complete all as specified and directed.
M&L for preparing old decorated plastered or unplastered surfaces of walls and applying one coat of white wash on walls complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of whitewash on walls complete all as specified and directed .
M&L for new plastered surfaces of walls and applying two coats of cement base paint of approved shade over alkali resistant primer complete all as specified and directed.
M&L for old decorated plastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re?fixing or removal complete all specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re?fixing or removal complete all specified and directed.
Taking up or down 25mm bore steel tubing and connections, including cleaning for re?fixing or removal complete all specified and directed.
S&F 15mm bore galvinised steel water tubing 'medium grade' including necessary fitting such as GI bends, tee, union, etc fixed on walls and ceilings or laid in floors complete and connecting to water supply pipe line complete all specified and directed.
S&F 20 mm bore galvinised steel water tubing 'medium grade' including necessary fitting such as GI bends, tee, union, etc fixed on walls and ceilings or laid in floors complete and connecting to water supply pipe line complete all specified and directed.
S&F 25 mm bore galvinised steel water tubing 'medium grade' including necessary fitting such as GI bends, tee, union, etc fixed on walls and ceilings or laid in floors complete and connecting to water supply pipe line complete all specified and directed.
S&F in repairs for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all specified and directed.
S&F in repairs 10litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets. Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern fixed in position and connecting complete all specified and directed.
S&F in repairs vitreous china bowl urinal flat back size of 465x355x265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flushing pipe and waste pipe) complete all as specified and directed.
S&F in repairs for 750mm long PVC waste pipe of 40mm dia (Urinal/WHB/sink) including all fitting complete all as specified and directed complete all specified and directed.
S&F in repairs white vitreous China wash hand basin (flat back or angle back type) of size 550x400mm fixed on and including cutting for and pinning in ends of brackets or erecting stand complete including Waste fittings iron pipe 32 mm , brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all specified and directed.
S&F in 25mm size ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 25mm-455gms) and fly nut complete screwed for iron pipe and fixed complete all specified and directed.
S&F in repairs Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all specified and directed.
S&F 450mm long PVC connections 15mm size with PTMT nuts at both end complete all specified and directed.
S&F 600mm long PVC connections 15mm size with PTMT nuts at both end complete all specified and directed.
S&F in repairs towel rail of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all specified and directed.
S&F in repairs 15mm size Bib taps, cast fency type and choromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all specified and directed.
S&F in repairs 15mm size Pillar taps fancy type ,swan neck cast copper alloy, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all specified and directed.
S&F in repairs 15mm size angle valve, cast copper alloy chromium plated fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all specified and directed.
S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 25mm bore pipe complete for iron pipe and fixed all specified and directed.
S&F in repairs white vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests with 'P' or 'S' trap of cast iron 100 mm front and back inlet including all connection and provision of lime concrete base complete all specified and directed.
S&F in repairs white vitreous China wash down water closet pan (pedestal pattern) with fixing bolts plastic water closet seat cover with hinge, closet pattern with flat bottom and cover with aluminized hinging device including all connected complete all specified and directed.
S&F in repairs sainless steel grating with or without hole of 100mm dia fixed with cement complete all as specified.
S&F Soap dish, vitreous China white, approximate size 160x 160x90mmsoap tray embedded in the wall complete all as specified and directed.
Taking down shutter only of any description exc 1 sqm but n. exc 2 sqm each complete all as specified and directed.
Taking down shutters exceeding 1.0 Sqm but not exceeding 2.0 Sqm each in and refixing in same opening after resecuring or easing and adjusting complete all as specified & directed.
Taking down chowkhats or frames (without taking off shutters from the frames) not exceeding 1.5sqm each complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with particle board core and 2,4 or 6 raised panel design with 5mm thick Moulded colour PVC Sheet on the front Face & 5mm Plain colour PVC sheet on back face, fixing in frame at site complete specification & drawing as per SSR complete all as specified and directed.
S&F Factory made PVC single door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as per specification and drawing of SSR Part-I and the door frame to be fixed to the wall using MS screw 75mm long with PVC fastener as per manufacturer's, instruction complete all as specified and directed.
Demolition of cement concrete (unreinforcement) of any description and in any position not otherwise specifically provided for complete all specified and directed.
M&L for water proofing treatment to RCC sunken slab as specified below and as directed by Engr-in-Charge:- (a) 15mm plaster in CM (1:3) with WPC on raised vertical surface. (B) Cleaning the surface with wire brush/coir brush, removing loose material like dust particles ,dirt etc. (c) Creating fillet covering of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and vertical surfaces. (e) Provision of glass fibre mesh of 2x2 mm immidiately on above coating (f) Apply second coat of two component modified polymer coating after 72 hours (g) Laying concrete (1:4:8) over the coating as per requirement (h) Joining the sanitary pipe with non shrink cementatiuos grout (k) Complete the treatment to be carried out by authorised applicator of waterproofing manufacturer NOTE : (i) The Treatment shall be carried out as per the manufacturers instruction and as directed by Eng-in-Charge. (ii) The plan area of floor shall be consider for payment. (iii) WPC shall be measured and paid saperately.
Supply only integral Water proofing compound complete all as specified and directed.
Taking down existing steel rolling shutter of size not exc 20 Sqm with all connected items and repairs / replace the lath of steel rolling shutter and locking arrangement, greasing, tighting, of helical wire spring including welding when ever required rolling etc, complete and make in serviceable condition and applying two coats of synthetic enamel paint including preparation of old painted surfaces and refixing in the same opening complete all specified and directed. Note:- (i) Lath of steel rolling shutters, lock plate with locking arrangement and shall be measured and paid for seperately. (ii) Rate of spring shall be deemed to included in the unit quoted rate. (iii) Unservicanle items shall be measured and paid seperately as supply only under respective items.
S&F 1.25mm thick steel rolling shutters, with out ball bearing, as specified including top cover, an?choring rod, hasp and staple and one shop coat of primer; erected in position as indi?cated, complete: push pull or manual type complete all as specified and directed.
Supply only ball bearing for rolling shutters complete all as specified and directed.
Supply only Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
Supply only lath for rolling shutter (thickness of lath 1.25mm) complete all as specified and directed.
Supply only mild steel 0.45 m rolling shutter spring of wire dia 7mm complete all as specified and directed.
S&F prefabricated lock plate length not less than 2.00 mtr but n. exc 4.00 mtr and width not less than 0.15 m but not exc 0.20m of riveted construction made out of mild steel sheet 3.15 mm thick ,reinforced with mild steel angle 35 x 35 x 5 mm size at bottom and locking arrangement with two 50 mm bow handles and flat iron 25 x 3 mm to fix the lath and lock plate complete all as specified and directed.
Dismantling cast iron work of any description complete all as specified and directed.
S&F 100mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints, but fixed to walls complete all as specified and directed.
S&F 75mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints, but fixed to walls complete all as specified and directed.
S&F 100mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed.
S&F 75mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed.
Extra over 100mm cast iron pipes and fittings if lead joint is provided in lieu of cement joint complete all as specified and directed.
Extra over 75mm cast iron pipes and fittings if lead joint is provided in lieu of cement joint complete all as specified and directed.
M&L for CI floor trap 100 mm with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed by Engr-in-charge.
M&L for Jodhpur stone as in main hole covers of 75mm thick as long as per site requirement and flush jointed in cement mortar (1:6) complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan – necks, etc. including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fitting and accessories) of any description complete all as specified and directed.
M&L for bands, straps, supports or stays for rainwater , Ventilating pipes, including bolts , if required; hooks ( stay), heavy, for large gates; hook and lintle hanges; large hasps and staples ; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; knee piece inserts; two way and three ways straps , plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for cutting holes in brick walls n. exceeding half brick wall built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) Type B-1 as required complete all as specified and directed.
S&F 110mm bore PVC (SWR) rain water pipe single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
M&L for cement concrete type B1, (1:2:4) (using 20mm graded stone aggregate) as in benching/coping and the like including weathering slightly round or chamfered angles and throating complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L for TMT MS bars 10 mm dia and over, out to length , bent to shape required , including crancking , bending , spirally for hooping for colums hooking ends and binding with mild steel (annealed) not less than 0.9 mm dia or securing with clips specified and directed.
M&L for drilling 14mm dia holes in old concrete upto depth not less than 150mm cleaning the holes by blower and injecting grouting chemical of make-HILTI product HY-150 or equivalent into the holes & inserting 10 mm dia TMT bars into holes all as directed. Note :- TMT MS bars will be measured and paid seperately.
Dismantling of brick work or block masonry built in cement mortar complete all as specified and directed.
M&L Precast cement concrete type C1 (1:3:6) using 20mm graded stone aggregate block masonry with solid blocks exc. 10 cm in width and setting in cement mortar (1:6) complete all as specified and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F anodised aluminium frame for doors, windows, ventilators powder coating to (minimum thickness of powder coating 50 micron) with one or more rebates including joining cleat for fixing etc complete all as specified & directed.
S&F 150 mm size extruded aluminium alloy handles fabricated type, anodised and polished etc complete all as directed.
S&F 150mm size aluminium anodised barrel tower bolt of extruded section all as specified and directed.
S&F 300mm aluminium alloy anodised sliding door bolt with hasp,staple and fixed clips of sheet,cast or extruded section and fixed bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average wirth of aperture 1.40mm and fixed with stainless steel wire staple etc complete all as directed.
Hacking out old broken glass exc 1.5 sqm (any thickness, size, quality or description) from metal frames, including punching or drilling out old glazing pins / spring clips and glazed with oil putty and providing and fixing new ones complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
M&L cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate filling of pressed steel frame and hold fast blocks etc complete all as specified and directed.
S&F steel ventilators with top hung shutter including hinges, steel peg stay including painting with one shop coat of zinc chromate primer, complete all as specified and directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay complete with glazing bars, dovetailed or welded, all as specified and directed.
M&L for TMT MS bars of 5mm dia and upto 10mm dia as in stirrups and spacers cut to lengh bent to shape reqd incl cranking bending spirally for hooking for column and binding with MS annealed wire not less than 0.9mm dia complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) (1:2:4) type B-1 using 20mm graded stone aggregate as in chajjas etc complete all as specified and directed.
S & F aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan/socket) complete with all accessories such as switches, sockets, celing rose, wall brackets etc fitted and removing dismantled material & making good disturbed surfaces of walls/floor etc and matching with existing surface all as specified and directed.
M&L for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into in existing concealed/ surface conduit for one light point /fan point controlled by one switch and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated/ white bakelite sheet cover/ modular plate for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and connecting to earth dolly in MS Sunken box, making good the disturbed surfaces with cement sand mortar (1:3) to match with the existing surfaces complete all as specified & directed.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar (1:3) to match with the existing surfaces for One light/ Fan Point controlled by one switch complete all as specified & as directed.
All as per item No. 114.00 (here-in-before) but for one 3 pin socket out let 5 Amp on same board.
All as per item No. 114.00 (here-in-before) but for one 3 pin socket out let 5 Amp on independent board.
All as per srl item No. 114.00 (here-in-before) but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated sheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F switch piano flush type, 6 Amp 240 Volt, AC one way etc complete all as specified and directed.
S&F switch socket combination 3 pin 16 Amp, flush type complete all as specified and directed
S&F flush type socket outlet 5 Pin 6 Amp, 230 volts AC complete all as specified and directed.
S&F Ceiling fan regulator flush type electronic step type , 230V 450 Watt complete all as specified and as directed
S&F ceiling rose surface PVC/ Polycarbonate, 3 terminals with back plate etc complete all as specified and directed.
S& F modular type switch 6 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed.
S& F modular type switch 16 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed.
S&F modular one socket outlet 5 Pin 5 Amp 230 volts AC complete all as specified and directed.
S&F modular one socket outlet multipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC complete all as specified and directed.
S&F modular Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F in renewal modular white cover plate with frame, 2module complete all as specified and directed.
S&F modular white cover plate with frame, 3module complete all as specified and directed.
S&F in renewal modular white cover plate with frame, 4module complete all as specified and directed.
S&F in renewal modular white cover plate with frame, 6module complete all as specified and directed.
S&F in replacement of Batten holder 2 Amp 250V AC with skrit ISI marked top line series , pvc/ polycarbonate cased body of brass with back plate suitable for batten fittings and with LED bulb 9/10 watt B22 base 6000K complete all as specified and directed.
S&F in replacement of Smart bright Batten Series, LED luminaire using LED 20 watt 110 Lumens/watt with diffuser which ensures uniform distribution and comfort, batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminium housing, Energy efficient, Flicker free start Inbuilt driver unit, Suitable for wall and ceiling mounting using brackets with and including the luminaire testing on completion as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl),complete all as specified and directed.
S&F in renewal LED light fitting 9/10 Watt 2 feet light luminarire with poly carbonate cover complete with all acessories and driver including connections with with 3 core copper wire of suitable size complete all as specified and directed.
S&F in renewal LED Ceiling light square recessed mounted LED flat panel complete 600mm x 600mm, 230 volts 35/36 Watt LED light fixing on Surface/ceiling and connecting with 3 core copper conductor cable etc complete all as specified and directed.
S&F in renewal LED Ceiling light circular recessed mounted/ Surface mounted LED flat panel complete, 230 volts 10 Watt LED light fixing on wall/ceiling and connecting with twin core copper conductor FR-LSH cable etc complete all as specified and directed .
S&F in replacement of LED Security Light Luminaire 35 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed.
S&F in replacement of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complaints complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with minimum capacity 200 Amp bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with minimum 200 Amp bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F in repair sheet metal enclosure MCB distribution board triple pole & neutral 415 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F in renewal MCB TPN 63 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB TPN 40 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed .
S&F in renewal MCB SPN 63 Amp C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB SPN 40 Amp C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB SP 6 to 32 Amp B curves MCB repturing capacity 10 KA etc complete all as specified and directed.
M&L for Sub main wiring with 2 runs of 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 20mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof or concealed type on wall and one run of 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of PVC conduit of 20mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 20mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof or concealed type on wall and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of PVC conduit of 20mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof or concealed type on wall and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof or concealed type on wall and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 4 runs of 10 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 32mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof or concealed type on wall and one run of 10 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Four runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 32mm dia shall be measured and paid as one unit length.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 3.0 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI pipe 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways ,PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work,disposal of suplus spoil to a dstance not exceeding 50mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including dismantling of old earth plate complete all as specified and directed. Note :- (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x 6 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 25X4mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40 mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 4 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
S&F ceiling fans 1200mm sweep white in colour of Aluminium blades (three numbers) and body, double ball bearing, down rod, fan motor, pair of canopy shackle, assembly kit, electronic regulator with minimum air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) etc suitable for SP 230 to 250 volts, 50 Hz, AC supply complete all as specified and directed.
S&F Exhaust fan 300mm sweep metal body, heavy duty, four blade, double ball bearing, 1400 RPM, minimum air delivery dishcarge 1710 CMH suitable for SP 230/250V, 50 Hz AC Supply with protective bird guard with louver shutters including grouting of frame in wall and connecting with and including 3 run 0.5 Sqmm single core, PVC insulated but sheathered FRLSH multistranded copper conductors cable from ceiling rose to exhaust fan inlcuding making hole of size 300mm complete all as specified and directed.
S&F double door VTPN Distribution box sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting , 8 way, 415 Volt, fitted with shrouded nutral , insulated pin type copper bus bar , Din rail , earth bar of of 4 way , complete with MCCB 160 Amps as incoming complete all as specified and directed.
Taking out energy meter from site and repair, cleaning meter box and refixing/ reconnecting electric meter near DB box complete all as specified and as directed.
M&L for Cement Concrete (1:2:4) type B1 using 20mm graded stone aggregate for pole base foundation and coping complete all as specified and directed.
M&L cement concrete PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in pole foundation complete all as specified and directed.
Disconneting of Split AC Out Door Unit complete from roof Slab and servicing AC Unit with minor repair, filling Gas and refixing it on PCC platform complete all as specified and as directed.
S&F in replacement Intelligent, flexible & smart outdoor lighting control unit for automatic switch ON at dusk automatic switching OFF at Dawn with Analog Time Switch, high voltage and low voltage protection, 3 Pole / 230V For 65 Amp load equally distributed over 3 phases. Minimum IP54 Degre of Protection complete all as specified and directed.
S&F in replacement of U/S highmast flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 100 W LED as specified and directed.
S&F in replacement of U/S highmast flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 150 W LED as specified and directed.
S&F in renewal of suction line (1/4') copper pipe or suitable size as per existing dia and length with nitrile rubber protection as required at site complete all as specified and directed.
S&F in renewal of discharge line (5/8') copper pipe or suitable size as per existing dia and length with nitrile rubber protection as required at site complete all as specified and directed.
S&F unsv 6 sqmm aluminium service wire 2 core fixed to wall /ceiling using clamps of suitable size including removing the existing for replacement complete all as specified and as directed.
M&L for cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line and finished surfaces by extracted material and provided with 150mm thick PCC (1:3:6) type C-2 as top layer to match the existing surfaces and remove surplus extracted material 50 m away complete all as specified and directed.
S&F in replacement of GI tubes of size 50 mm bore ,ISI MARKED medium grade, galvanised, with all fitting and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed.
S&F in replacement of Rotational moulded polythelyne water storage tanks 1000Ltr capacity cylinderical/vertical with closed top hoised and fixed in position with complete suitable size of staging complete all as specified and directed.
S&F in replacement of 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed conforming to IS 9338 complete all as specified and directed.
S&F in replacement of Ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed with 25mm dia complete all as specified and directed.
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation & getting out in Soft/ loose soil etc for laying of cable complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed.
M&L for dry tibba sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supply and lay un reinforced precast concrete cable covers Class LV,Type 1, flat, size 250mm x 150mmx 40mm complete all as specified and directed.
Disconnecting and Taking out of old LT armored PVC cables from trenches of any size/core/any voltage grade from trenches for replacement all as directed.
S&F in replacement of GI Tubes of size 50 mm bore ,ISI MARKED light grade, galvanised, with all fitting and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed.
S&F in replacement of GI Tubes of size 40 mm bore ,ISI MARKED light grade, galvanised, with all fitting and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed.
KRISHNA CONSTRUCTION COMPANY (BID ID -3190877)
YOG INFRA (BID ID -3195676)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .