Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹21.9 L+₹1.5 L (7.36%)Admitted-Finance 146 B SICOP BIRPUR INDUSTRIAL AREA BARI BRAHMANA JAMMU 181133 J K | BARI BRAHMANA | JAMMU | JAMMU AND KASHMIR | 181133 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical CRITERIA NOT FULFILLED |
| Sl No | Description | Qty | Unit | jaima electricals L2 | M/s Chopra Constructions L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out soft/loose soil complete all as specified and directed. | 133.38 | CUM | 120 ₹16,005.6 | 50 ₹6,669 Lowest |
| 2.00 | All as per Item No: 1 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed | 0.64 | CUM | 20 ₹12.8 Lowest | 70 ₹44.8 |
| 3.00 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 63.15 | CUM | 20 ₹1,263 | 5 ₹315.75 Lowest |
| 4.00 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. | 70.23 | CUM | 20 ₹1,404.6 | 5 ₹351.15 Lowest |
| 5.00 | Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed. | 50.22 | CUM | 2,200 ₹1,10,484 | 200 ₹10,044 Lowest |
| 6.00 | Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed | 4.34 | Per 1000 Nos | 15,000 ₹65,100 | 3,000 ₹13,020 Lowest |
| 7.00 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed. | 1.16 | CUM | 2,500 ₹2,900 | 1,200 ₹1,392 Lowest |
| 8.00 | M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed. | 0.1 | CUM | 2,500 ₹250 | 1,200 ₹120 Lowest |
| 9.00 | Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed.
NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. | 40 | RM | 1,275 ₹51,000 | 1,150 ₹46,000 Lowest |
| 10.00 | M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 95 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:- Excavation and earth, sand cushioning and protection for cable work shall be measured and paid separately. | 190 | RM | 785 ₹1,49,150 | 415 ₹78,850 Lowest |
Tender Value
₹24.6 L
EMD Value
₹49,100
Closing Date
28 Aug 2026, 6:00 pmClosed
CWE RAJOURI
HQ CWE Rajouri C/O 56 APO
PROVN OF 100 KVA TRANSFORMER, VOLTAGE STABILIZER AND CONNECTED ITEMS FOR ELECTRICITY CONNECTION AT DERA KI GALI (DKG) UNDER AGE (I) CIF (R)
2026_MES_782100_1
CWE/PAL-52/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Palma
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) CIF(R)
₹49,100
Yes
28 Sept 2026
31 Jul 2026
4 Sept 2026
31 Jul 2026
28 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches, in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out soft/loose soil complete all as specified and directed. | 133.38 | CUM | - | - |
| 2 | All as per Item No: 1 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed | 0.64 | CUM | - | - |
| 3 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 63.15 | CUM | - | - |
| 4 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. | 70.23 | CUM | - | - |
| 5 | Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed. | 50.22 | CUM | - | - |
| 6 | Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed | 4.34 | Per 1000 Nos | - | - |
| 7 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed. | 1.16 | CUM | - | - |
| 8 | M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed. | 0.1 | CUM | - | - |
| 9 | Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed.
NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. | 40 | RM | - | - |
| 10 | M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 95 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:- Excavation and earth, sand cushioning and protection for cable work shall be measured and paid separately. | 190 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
tender522627.pdf
Tender Documents • 1.31 MB
BOQ_876180.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .