Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.1 CrAdmitted-Finance | ₹93.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹93.6 Cr+₹52.1 L (0.56%)Admitted-Finance | ₹93.6 Cr+₹52.1 L (0.56%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Chicago Constructions International Pvt Ltd L2 | R K INFRA (INDIA) PVT LTD L1 |
|---|---|---|---|---|---|
| 1.00CIVIL WORKS Pile Foundation | |||||
| 1.01 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M -35 (Min Cement quantity -400kg/m3 and no payment shall be made for extra cement) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.600 mm dia piles | 2,576.4 | Metre | 7,000 ₹1,80,34,800 | 6,686 ₹1,72,25,810.4 Lowest |
| 1.02 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M -35 (Min Cement quantity -400kg/m3 and no payment shall be made for extra cement) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.700 mm dia piles | 6,741.9 | Metre | 8,450 ₹5,69,69,055 Lowest | 9,099 ₹6,13,44,548.1 |
| 1.03 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M -35 (Min Cement quantity -400kg/m3 and no payment shall be made for extra cement) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete,including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.800 mm dia piles | 5,335.2 | Metre | 10,500 ₹5,60,19,600 Lowest | 10,959 ₹5,84,68,456.8 |
| 1.04 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile 137 tonne capacity. Initial test (For 600mm dia) | 1 | Per test | 5,94,000 ₹5,94,000 | 5,85,675 ₹5,85,675 Lowest |
| 1.05 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile 137 tonne safe capacity. (Test Load 1.5 times the Safe capacity) Routine test(For 600mm dia Pile) | 1 | Per test | 3,61,680 ₹3,61,680 | 3,36,609 ₹3,36,609 Lowest |
| 1.06 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile 188 tonne capacity. Initial test(For 700mm dia | 1 | Per test | 8,27,200 ₹8,27,200 | 6,03,057 ₹6,03,057 Lowest |
| 1.07 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile 188 tonne safe capacity. (Test Load 1.5 times the Safe capacity) Routine test(For 700mm dia Pile) | 2 | Per test | 4,96,320 ₹9,92,640 | 3,69,533 ₹7,39,066 Lowest |
| 1.08 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile 251 tonne capacity. Initial test(For 800mm dia) | 1 | Per test | 11,04,400 ₹11,04,400 | 8,05,145 ₹8,05,145 Lowest |
| 1.09 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile 251 tonne safe capacity. (Test Load 1.5 times the Safe capacity) Routine test(For 800mm dia Pile) | 2 | Per test | 6,62,640 ₹13,25,280 | 5,15,052 ₹10,30,104 Lowest |
Tender Value
₹85.2 Cr
EMD Value
₹5 L
Closing Date
10 Apr 2026, 5:00 pmClosed
Managing Director, INKEL Limited
1st Floor, Ajiyal Complex, Post Office Road, Kakkanad, Cochin - 682030
Civil and MEP works
2026_INKEL_838217_1
NIT/INKEL/KIIFB/2025-26/171 dated 19/02/2026
Open Tender
Civil Works - Buildings
Item Rate
540 days
Taluk Head Quarters Hospital Pulinkunnu
As per Tender Document
21 documents required · 21 mandatory
₹17,700
₹5 L
Yes
INKEL Limited
30 Apr 2026
19 Feb 2026
13 Apr 2026
20 Feb 2026
10 Apr 2026
5 Mar 2026
26 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1CIVIL WORKS Pile Foundation | |||||
| 1.01 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M -35 (Min Cement quantity -400kg/m3 and no payment shall be made for extra cement) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.600 mm dia piles | - | Metre | - | - |
| 1.02 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M -35 (Min Cement quantity -400kg/m3 and no payment shall be made for extra cement) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.700 mm dia piles | 1 | Metre | - | - |
| 1.03 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M -35 (Min Cement quantity -400kg/m3 and no payment shall be made for extra cement) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete,including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.800 mm dia piles | 1 | Metre | - | - |
| 1.04 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile 137 tonne capacity. Initial test (For 600mm dia) | - | Per test | - | - |
| 1.05 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile 137 tonne safe capacity. (Test Load 1.5 times the Safe capacity) Routine test(For 600mm dia Pile) | - | Per test | - | - |
| 1.06 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile 188 tonne capacity. Initial test(For 700mm dia | - | Per test | - | - |
| 1.07 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile 188 tonne safe capacity. (Test Load 1.5 times the Safe capacity) Routine test(For 700mm dia Pile) | - | Per test | - | - |
| 1.08 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile 251 tonne capacity. Initial test(For 800mm dia) | - | Per test | - | - |
| 1.09 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile 251 tonne safe capacity. (Test Load 1.5 times the Safe capacity) Routine test(For 800mm dia Pile) | - | Per test | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tenderdoc.pdf
Tender Documents • 1.34 MB
Technicalspec.pdf
Tender Documents • 3.04 MB
Dwng1.pdf
Tender Documents • 22.43 MB
Dwng2.pdf
Tender Documents • 23.06 MB
GRIHA.pdf
Tender Documents • 0.25 MB
Soilreport.pdf
Additional Documents • 9.26 MB
BOQ_1411914.xls
BOQ • 1.09 MB
Corrigendum5.pdf
PDF • 0.14 MB
Corrigendum2.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .