Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC | ₹3.4 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹3.4 Cr+₹2.3 L (0.67%)Rejected-Finance | ₹3.4 Cr+₹2.3 L (0.67%) | L2 | Rejected-Finance Higher rate quoted |
| 3 | L3₹3.4 Cr+₹2.9 L (0.87%)Rejected-Finance NOT AVAILABLE | NA | NA | 121004 | ₹3.4 Cr+₹2.9 L (0.87%) | L3 | Rejected-Finance Higher rate quoted |
| 4 | L4₹3.4 Cr+₹7.2 L (2.14%)Rejected-Finance VILLAGE DOHAL PO PATTI TEHSIL PALAMPUR DISTRICT KANGRA | KANGRA | HIMACHAL PRADESH | 175013 | ₹3.4 Cr+₹7.2 L (2.14%) | L4 | Rejected-Finance Higher rate quoted |
| 5 | L5₹3.5 Cr+₹13.4 L (3.99%)Rejected-Finance | ₹3.5 Cr+₹13.4 L (3.99%) | L5 | Rejected-Finance Higher rate quoted |
Tender Value
₹3.7 Cr
EMD Value
₹4.1 L
Closing Date
21 Feb 2023, 5:00 pmClosed
Executive Engineer JS Division Padhar
Executive Engineer JS Division Padhar
SH Supply and errection of Pumping Machinery with allied accessories and Providing Laying Jointing Testing and Carriage MSERW pipe in Rising Main and Construction Thrust Block
2023_HPIPH_68700_1
11429-78 dated 10.02.2023
Open Tender
Pumps/Motors
Item Rate
365 days
Tandoo
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,500
EE Padhar
₹4.1 L
Yes
17 May 2023
10 Feb 2023
22 Feb 2023
10 Feb 2023
21 Feb 2023
10 Feb 2023
Amount
Bouster Stage:-Supply and installation at site of submersible clear water pump set of all approved make such as KSB/Clama /SU/Joinsion confirming to latest relevant BIS code. The pump should be fitted with free flow impellers of suitable alloys as per BIS-8034-1978 latest sunitable for lifting raw water having 6000 PPM turbidity, grease packed bearings and shaft with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft confirming to BIS specifications. The pump shall be directly coupled to submersible squirrel cage electrical induction motor of same make confirming to BIS-9283-1979 (latest with upto date ammendments) totely dust and water proof on submirsible duly isolated from the pump by intermediate casing with double mechanical seal in oin chamber and grease packed lubricated bearings and provided with stain less steel thrust bearing plate to with stand non vertical load with minimum bear and tear. It should also be fitted with a device to take up expention on water with heating of motor. The pump should include water level guard, errection clamps, cable clips and depth gauge etc. and suitable for operation in data give.
Supply and errection at site of suitable oil immeresd Star Delta Starter/ATS/stator Rotor Starter of standard approved make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with initial oil filling.
Providing and installation at site M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
Supply and installation ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen and other approved make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Supply and installation Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
Supply and installation MCB/Oil circuit breaker of suitabe capacity of Kilburn/L.T./LK/MEI/Standard and all approved make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
Supply and installation 3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Supply and installation Earth leakage circuit breaker of recomended approved make such as (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Supply and installation Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Supply and installation Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltage difference.
Supply and installation Single phase preventor of reputed make & suitable cacpacity.
Supply and installation at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed and approved make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 10.20 Kg/cm^²
Supply and installation at site of Kirlosker/Kilburn/IVC/Fouress/Gled/BHEL/Leader all other approved make of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of Pump for withstanding nominal seat pressure of 10.20 Kg/cm^²
Supply and installation at site of Kirloskar/Kilburn/IVC/Fouress/Gled/Bhel/Leader approved make of suitable size Cast Iron/Cast Steel ASA-300 double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main i.e. 65 mm dia for withstanding nominal seat pressure of 51 Kg/cm^² & 2nd class ASA-300.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power 3 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/ Gloster/ ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager /Bajaj approved make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming toBIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/ Bajaj and approved make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming toBIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply and installation at site of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
P/L column pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure indicated in item No. 1e(ii).
Ist Stage :-Supply and errection at site of Horizental spindle, vertical split casing Single/Multistage centrifugal pumps of all approved make such as KSB/Mather & platt/Jyoti/ Kirloskar/ WASP/Best and Cromption conforming to BIS (latest with upto date amamendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 6000 ppm with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible cuppling on a common base plate to Kirloskar/NGEF/Cromption/Siemen/ Joti/ABB/ Marathan approved by the department induction electric TEFC motors ISO conforming to IS 12615-2011 with IE-2 suitable for operation on the data given in data sheet.
Supply and installation at site of suitable oil immeresd Star Delta Starter/ ATS/ stator Rotor Starter of standard approved make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with initial oil filling. Note:- Star- delta - starter upto 37.5 KW. ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50KW.
Providing and installation M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
Supply and installation at site ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Supply and installation Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
Supply and installation MCB/Oil circuit breaker of suitabe capacity of Kilburn/L.T./LK/MEI/Standard and other approved make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
Supply and installation 3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
P/L Earth leakage circuit breaker of recomended approved make such as (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Supply and installation Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Supply and installation Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltage difference.
Supply and installation Single phase preventor of reputed make & suitable cacpacity.
Supply and installation at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed and approved make of suitable size cast iron/cast steel double flanged sluice valve having size minimum one step higher than delivery of pump and capable of with standing nominal seat pressure of 10.20 Kg/cm^²
NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to or class 300 ASA (Seat pressure 52 Kg/cm^²
Supply and installation at site of Kirlosker/Kilburn/IVC/Fouress/Gled/BHEL/Leader and other approved make of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size mimumum one set higher than delivery of Pump for withstanding nominal seat pressure of 10.20 Kg/cm^²
NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class or class 300 ASA (Seat pressure 52 Kg/cm^² or class (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply and installation at site of Kirloskar/Kilburn/IVC/Fouress/Gled/Bhel/Leader and other approved make of suitable size Cast Steel ASA-300 double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main i.e. 65 mm dia for withstanding nominal seat pressure of 51 Kg/cm^² & class ASA-300.
Supply and installation at site of Kirlosker/Kilburn/Pelican/Leader of suitable size cast iron flanged sluice valve confirming IS-780 size one set higher thanl to dia of sunction pipe, PN-1 provided with hand wheel/ cast iron Cap.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power 3 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/ Gloster/ ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager /Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming toBIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply and installation at site of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/ laying, jointing, testing of Rising Main & C/O Thurst Block:-Excavation in foundation and trenches etc.(for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/hard rock or chiselling soft /hard rock where blasting is prohibited in all lifts including trimming and dressing of sides,levelling of beds to correct grade i/c shoring, strutting, planking, timbering & dewatering wherever required,stacking the useable & unuseable material/soil separately & after laying,jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposited layer by ramming & watering and then disposing of all surplus excavated soil/unusable material as directed with in all leads and lifts including restoration unmetalled surfaces to its original; condition & including cost of diversion for traffic,night signals,fixing caution boards,crossing over trenches for access to houses,fencing etc.complete in all respects with in all leads & lifts as per directions of Engineer -in-Charge.
Providing, laying, jointing, fixing and testing in trenches MSERW pipe of following diametres conforming to BIS 3183-2007, of suitable grade and having wall thickness as specified below with plain end and capable of with standing required test pressure in randum length of 4 to 7 metres,including specials,short pieces, bends,reducers,tee etc.made from parent tube,providing and welding of MS flanges detailed as below.The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (Two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes,3 mm thick compressed asbestos fibre/ synthetic rubber gaskets confirming to relevant BIS standards.The laying of pipe will include all operation such as cutting,welding,jointing, providing & fixing of MS flanges, fabrication of bends,tee etc. including lowering and laying in excavated trenches to ensure required level including flushing,cleaning and hydraulic testing complete in all respects to the entire satisfaction of the Engineer-in-Charge.The fabricated bends shall have three of four cuts having its radious not less than five times the dia.of pipe.The pipes shall be factory galvanised(zinc coating both insides and outsides) as per relevant IS standards and the damaged portion of the pipes and specials made from the parent tube shall be provided anticorrosive treatment by applying two coats of the anti corrosive bitumineous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon// L & T of ISI marked make.The rates also includes entire carriage of material, flusing,cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts.( earth work in trenches will be measured and paid for separately).
Dia of pipe T hickness IS Specification Flanges Table
400 mm (Booster Stage) 4.80 mm MS pipe L 210 or A IS/ISO-3183-2007 5
400 mm (Ist Stage) 6.40mm MS pipe L 390 or X-56 IS/ISO-3183-2007 28
Providing, laying, jointing, testing and commissioning at site in trenches bevelled ended BIS marked MSERW pipe of various grade conforming to IS/ISO- 3183-2012, of suitable grade or its eqilvalent specification latest with upto date ammendements of following dia with upto date ammendements having wall thickness and per Rmt weight as mountained below and capable of with standing required test pressure as prescribed in BIS code in randum length of 6 to 7 metres. The pipe ends shall be bevelled suitable for butt welding including the cost of jointing, with butt welding confirming to IS-816-1969 or latest as applicable ends with upto date ammendements, (with leak proof ) in three lavers at site of work with welding, rods of standared make and all allied accessories what ever required for welding at site, tail pipes, tees, bends and other specials manufactured from parent pipes as applicable to the particular reach and of approved specifications as per site conditions and cutting of pipes where ever required as per site requirement including carriage in all leads and lifts as per direction by Engineer-in-Charge. The pipe shall be haves Zinc coating insides and outsides confirming to IS/ISO-4736-1986 or latest with upto date ammendements and shall be engraved with code IS/ISO-3183-2007 or its equivalent. The laying shall be conforming to BIS 5822-1971 or latesty with upto date ammendments with complete in all respect to the satisfaction of the Engineer-in-Charge.
Dia of pipe Thickness IS Specification
400 mm ( Ist Stage) 6.40 mm MS pipe L 390 or X-56 IS/ISO-3183-2007
400 mm (Ist Stage) 5.60 mm MS pipe L 390 or X-56 IS/ISO-3183-2007
400 mm (Ist Stage) 4.80 mm MS pipe L 390 or X-56 IS/ISO-3183-2007
Providing and laying cement concrete 1 : 4 : 8 (1Cement : 4 Sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts.
Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centring , shuttering , strutting and propping etc.with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtr and removal of the same for insitu- reinforced concrete & plain concrete work in :-
Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters,buttresses,plinth and string courses and the like.
Providing & Laying cement concrete work 1:2:4 (1 cement 2 sand 4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
Foundation footings bases of columns and the like and mass concrete as per the entire satisfaction and direction of Engineer-in-Charge.
Providing mild steel / Tor steel reinforcement for RCC work including bending binding and placing in position complete upto floor two level as per the eintire satisfaction and direction of Engineer-in-Charge.
Saurabh Vasudeva
MNBN Enterprises
GANTANTAR THAKUR
Shashank Jagota Govt. Contractor
SS RANA CONSTRUCTION PRIVATE LIMITED
Sushant Puri
sanjeev govt cont
UEE Electrical Engineers Pvt Ltd
Naresh Kumar
Universal Electric Engineers
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .