Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.3 L+₹56,481.30 (6.49%)Rejected-AOC KACHEETTI PUTHEN VEEDU PALIYODE KUNNATHUKAL ANAVOOR P O TRIVANDRUM 695124 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695124 | L2 | Rejected-AOC L2 | |
| 3 | L3₹10.1 L+₹1.4 L (16.3%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹10.4 L+₹1.7 L (19.7%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹11.2 L+₹2.5 L (28.2%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹14.1 L
EMD Value
₹35,235
Closing Date
9 Jun 2025, 3:00 pmClosed
Executive Engineer
O/o Executive Engineer,PH Division (South), TVPM
AMRUT 2 PROPOSAL FOR PARTIAL COVERAGE IN KALADY PAPANMCOD, MELAMCOD ESTAT NEMOM PONUMANGLM WARDS UNDER KMA REPLACING EXISTING LINES EXTENSION OF EXISTING LINES PROVIDING NEW LINES WITH FHTCs P8 PROVIDING FREE CONECTIONS FOR WARDS UNDER KMA WWS
2025_KWA_766645_1
WRD/KWA-CE(SR)/TR/11392/2025
Open Tender
Civil Works - Water Works
Item Rate
365 days
Thiruvananthapuram
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,760
₹35,235
Yes
26 Jul 2025
28 May 2025
10 Jun 2025
28 May 2025
9 Jun 2025
28 May 2025
28 May 2025 - 9 Jun 2025
Amount
PIPE LAYING - Labour portion
15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
HOUSE CONNECTION
OD19953/2025-2026:Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm ASTM D-1785 ,SCH -40 PVC pipe and uPVC / GM /Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
OD19954/2025-2026:Providing additional length of house connection pipe using 20mm ASTM D-1785 ,SCH -40 PVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.3m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers
OD19949/2025-2026:Taking connection from the existing main (Single boring), supplying and fitting 25mm saddle piece, boring the main, supplying and fitting 25mm brass ferrule 1no, 25mm GM full way wheel valve1no, including all specials and connecting the newly laid main, testing the joints etc. complete but excluding cost of pipe
OD19952/2025-2026:Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC /GI Service line via T connection up to a length of 5 m using 20mm ASTM D-1785 ,SCH -40 PVC pipe ,fixing PVC valve ,water meter etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.12.4.1:Providing 15mm PVC Tap in the water meter assembly for 20mm connection, using 25mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.
OD19951/2025-2026:Providing granular sub base for restoration of tar cut surface using a mix of coarse sand and 40mm coarse aggregate including watering, consolidating, ramming, levelling etc complete as per the direction of departmental officers including cost of materials, labour, hire of tools and plants etc complete<br>1:2 (1 coarse sand : 2 graded stone aggregate 40 nominal size)
OD19950/2025-2026:Restoration of Tar Cut Portion Using Ready Mix Repair(Tar Macadam)
SUPPLY OF MATERIAL
OD19948/2025-2026:Supplying and laying 40mm ASTM Pipe
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
100.98.506:Supply of CI Plain End Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
100.98.508:Supply of CI Plain End Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
MOHANAKUMAR V (BID ID -2220687)
SHAJIN SHELTER (BID ID -2221782)
GOPAKUMAR BHASKARAN NAIR (BID ID -2221249)
Mohandas M (BID ID -2222432)
Bidder Name
MOHANAKUMAR V
GOPAKUMAR BHASKARAN NAIR
KIRAN A R
Mohandas M
SHAJIN SHELTER
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1249789.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .