Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC 19 B PANKAJINI CHATTERJEE ROAD KOLKATA 700033 | KOLKATA | KOLKATA | WEST BENGAL | 700033 | ₹1.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 CrRejected-Finance | ₹1.1 Cr | L2 | Rejected-Finance NOT L1 |
| 3 | L3₹1.2 CrRejected-Finance | ₹1.2 Cr | L3 | Rejected-Finance NOT L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Non submission of EMD. |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
3 Feb 2026, 10:00 amClosed
Assistant Chief Engineer
Araksha Bhawan 3rd Floor Block DJ Sector II Salt Lake City
Construction of New Central Correctional Home at Baruipur in the district of South 24 Parganas - Fire Fighting Works. (3rd Call)
2026_WBSPH_986726_1
WBPHIDCL/ACE/NIT- 140(e)/2025-2026
Open Tender
CIVIL AND ELECTRICAL WORKS
180 days
Refer to NIT
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹2.6 L
Yes
12 Feb 2026
10 Jan 2026
5 Feb 2026
10 Jan 2026
3 Feb 2026
18 Jan 2026
Providing, laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS:3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 250 NB (6.3 mm)
Providing, laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS:3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 200 NB (6.3 mm)
Providing, laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS:3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 150 NB
Providing, laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS:3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 80 NB
Providing, laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS:3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 65 NB
Providing, laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS:3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. 25 NB
Supplying, installation, testing and commissioning of Double flanged Sluice/gate valve with rating PN 1.6 NB with non rising spindle, bronze/ gun metal seat, ISI marked complete with nuts, bolts, eashers, gaskets and conforming to IS 780 of following sizes as required. Valve shall be supplied with matching Counter flange (IS:6392) , Botlts, nuts washer and gasket . 200 NB
Supplying, installation, testing and commissioning of Double flanged Sluice/gate valve with rating PN 1.6 NB with non rising spindle, bronze/ gun metal seat, ISI marked complete with nuts, bolts, eashers, gaskets and conforming to IS 780 of following sizes as required. Valve shall be supplied with matching Counter flange (IS:6392) , Botlts, nuts washer and gasket . 150 NB
Supplying, installation, testing and commissioning of Double flanged Sluice/gate valve with rating PN 1.6 NB with non rising spindle, bronze/ gun metal seat, ISI marked complete with nuts, bolts, eashers, gaskets and conforming to IS 780 of following sizes as required. Valve shall be supplied with matching Counter flange (IS:6392) , Botlts, nuts washer and gasket . 80 NB
Supplying, installation, testing and commissioning of Double flanged Sluice/gate valve with rating PN 1.6 NB with non rising spindle, bronze/ gun metal seat, ISI marked complete with nuts, bolts, eashers, gaskets and conforming to IS 780 of following sizes as required. Valve shall be supplied with matching Counter flange (IS:6392) , Botlts, nuts washer and gasket . 65 NB
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80 mm dia 150 NB
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80 mm dia 65 NB
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Supply & Fixing of "Dial Type (100mm) Glycerine filled Pressure Gauge" with metal isolation ball valve suitable for working pressure of 225PSI. Rate shall be inclusive of short pieces, nipples, elbows etc complete. (Make-H Guru) 150 mm dia
Supply & Fixing of "Dial Type (100mm) Glycerine filled Pressure Gauge" with metal isolation ball valve suitable for working pressure of 225PSI. Rate shall be inclusive of short pieces, nipples, elbows etc complete. (Make-H Guru) 100 mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/cfittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm. dia (wall thickness = 6.3 mm)
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required Stainless Steel (Grade 304)
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304)
Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation not execeeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layer not exceeding 150mm including watering and ramming etc. layer by layer complete a) With earth obtained from excavation of foundation.
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety](a) 1:3:6 proportion
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work GROUND FLOOR
Controlled Cement concrete(1:1:2) with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] (b) M 25 Grade.i)pakur varity
Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. GROUND FLOOR (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
Electrical schedule item Supplying and fixing 415V, 63 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make : L&T/Havells/HPL or equivalent as approved by EIC.)
Supplying and fixing 415V, 32 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make : L&T/Havells/HPL or equivalent as approved by EIC.)
Supplying and fixing 240V, 32 A DP MCB (10 kA & 'C' Curve) with MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (Make : HPL/Havells/L&T/Standard or equivalent as approved by EIC.)
Supplying & fixing sheet metal (16 SWG), 4 bars, 415 V, 100/125 A Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) Dimension of Al. bars [85mm long] : 4 x 25 x 5 mm Dimension of Sheet Metal Box : 500 x 150 mm
Supplying and fixing (2+4 Way) double-door SPN MCB Distribution Board Enclosure (607712) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment including (Make : All Legrand/ L&T/Havells or equivalent as approved by EIC.) a) 240V, 40A DP Isolator............... 1 Nos. b) 240V, 6 - 32A SP MCB (10kA & 'C' Curve).............. 4 Nos.
Supplying and fixing MCB SS 4 pole enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment including (Make : All Legrand/ L&T/Havells or equivalent as approved by EIC.) a) 40 A DP MCB Isolator............. 1 Nos. b) 6-32A range SP MCB('C' Curve & 10kA Charecteristics)... 2 Nos.
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three (03) no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works (a) 2 Module Switch Board including with (b) Supply & Fixing 240 V 16 A Modular key type 2 nos switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required . a) 240 V, 16 A Modular switch ................ 2 Nos.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent as approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand Legrand/Crabtree or equivalent as approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Average Run 8 Mtr).
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent asapproved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand Legrand/Crabtree or equivalent as approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Average Run 10 Mtr).
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish (ON BOARD) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.
Supplying & Fixing GI 8 Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works including following items. (Computer Board) (Make Legrand / Cabtree or equivalent as approved by EIC.) a) 240 V, 16A, 3 pin Modular type Socket ................. 1 Nos b) 240 V, 6A, 5 pin Modular type Socket ................. 2 Nos c) 240 V, 16A, Modular type Switch ................. 2 Nos
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm).
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required including (i) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required including (i) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) For 2 core upto 6 sq mm including Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (ii) For 2 core 6 sq mm cable.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) For 2 core upto 10 sq mm including Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (ii) For 2 core 10 sq mm cable.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) For 3 core upto 6 sq mm including Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (ii) For 3 core 6 sq mm cable.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) For 3 core upto 70 sq mm including Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (ii) For 3 core 70 sq mm cable.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) For 4 core upto 95 sq mm including Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (ii) For 4 core 95 sq mm cable.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) For 4 core upto 185 sq mm including Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (ii) For 4 core 185 sq mm cable.
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Laying of cable from 4 core 95 sqmm to on wall/surface incl. S & F MS saddles with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting.
Laying of one No. cable above 185 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish (i) From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (50 mm dia).
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe .
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Morrum Soil )
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. Solid No. 4 SWG GI wire.
Providing & fixing 25 mm X 5 mm G.I. Strip on surface or in recess for connection etc. as required.
Supplying & installing of following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convinient section, joint with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness.
Supplying & installing of following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convinient section, joint with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness DSR, P-18, sl no-4.1.2
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply & delivery of 1.1 kV grade XLPE Aluminium armoured cable (Make- Gloster /Havells/ KEI ) a) 4 core 185 sqmm
Supply & delivery of 1.1 kV grade XLPE Aluminium armoured cable (Make- Gloster /Havells/ KEI ) a) 4 core 95 sqmm
Supply & delivery of 1.1 kV grade XLPE Aluminium armoured cable (Make- Gloster /Havells/ KEI ) a) 4 core 70 sqmm
Main Fire Pump Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, centrifugal, End suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable 75 HP Squirrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2850 lpm at 70 m Head (Make-Willo or equivalent as approved by EIC.)
Jockey Pump Supplying, installation, testing and commissioning of electric driven pressurization pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Vertical type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts,3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head (Make-Willo or equivalent as approved by EIC.)
Diesel Driven Pump (a) Supplying, Installation, Testing and Commissioning of Diesel Engine-driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Diesel Driven Pump) (b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (c) Suitable 75 HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50mm thick glass wool with 1.0mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (d) M.S. fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 70m Head (Make : Kirloskar/KSB/ Wilomather & Platt or Lubi.)
Supply and delivery of 2 core 6 sqmm 1.1 KV grade aluminium XLPE armoured cable (Make- Gloster /Havells/ KEI )
Supply and delivery of 3 core 6 sqmm 1.1 KV grade aluminium XLPE armoured cable (Make- Gloster /Havells/ KEI )
Supply and delivery of 2 core 10 sqmm 1.1 KV grade aluminium XLPE armoured cable (Make- Gloster /Havells/ KEI )
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.18 MB
Tendernotice_2.pdf
PDF • 0.20 MB
Tendernotice_3.pdf
PDF • 0.41 MB
Tendernotice_4.pdf
PDF • 2.43 MB
BOQ_2408987.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid