| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 CrAccepted-AOC HOSPITAL ROAD NEAR ALIA MADRASSA HOUSE NO 0 CITY TOWN SILCHAR P O SILCHAR P S SILCHAR DISTRICT CACHAR PIN 788005 | CACHAR | ASSAM | 788005 | ₹30.1 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹30.1 CrRejected-Finance | ₹30.1 Cr | L2 | Rejected-Finance Rejected |
Tender Value
₹30.1 Cr
EMD Value
₹60.2 L
Closing Date
19 Oct 2024, 2:00 pmClosed
CE, PWD(Roads), Assam, Chandmari, Ghy-3
O/O The CE, PWD(Roads), Assam, Chandmari, Ghy-3
SOPD_G_24_25_17 Up-gradation of Road from Kathal R.C.C. Bridge to Silchar Hailakandi Road at Rosekandi via Barsangon Under SOPD-G for the year 2024-25.
2024_PWD_39507_1
CE/DEV/TB/232/2024-25/01 Dtd. Guwahati, 23rd September, 2024
Open Tender
Civil Works – Roads
365 days
Cachar
Please refer Tender documents.
5 documents required · 5 mandatory
₹20,000
₹60.2 L
Yes
O/O The CE, PWD(Roads), Assam, Chandmari, Ghy-3
29 Jul 2025
30 Sept 2024
19 Oct 2024
30 Sept 2024
19 Oct 2024
9 Oct 2024
30 Sept 2024 - 8 Oct 2024
8 Oct 2024
Amount
Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per Technical Specification Clause 201 By Manual Means
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) from private land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) from private land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. for grading- II Material
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade & Camber,applying & broming stone screening /binding materials to fill up the interstices of coarse aggregate, watering and compacting to the reqd. density.)(with an initial lead of 5.0km). A. By Manual Means (II ) Grading II Using Screening Type-B (11.2mm Agg.)
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade & Camber,applying & broming stone screening /binding materials to fill up the interstices of coarse aggregate, watering and compacting to the reqd. density.)(with an initial lead of 5.0km). A. By Manual Means (III ) Grading III (b ) Using screnning type -B(11.20 mm Agg)
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sb-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density ( including carriage up to initial lead of 5.0 km from quarry and carriage of mixed materials up to 10.0 Km initial lead from mixing plant )
Providing and relaying of ICBP available at existing Road excluding edge restrain beam as per drawing & technical specification clause 1504 and IRC SP:63-2004 and as directed by the department.(Reusing existing good I.C.B.P)
Inter locking concrete Block pavement Interlocking pavement block Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. Excluding Edge block/ Edge restraints
Providing and laying M-40 grade cement concrete Edge block/ Edge restraints complete as per Technical specification clause 1504.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
Surface Dressing (Providing and laying surface dressing as wearing course in single coat using crushed stone aggregates of specified size on a layer of bituminous binder laid on prepared surface and rolling with 8-10 tonne smooth wheeled steel roller)( including carriage up to initial lead of 5.0 km) ( The penetration grade bitumen shall have kinematic viscisity lying in the range 1x104 to 7x105 centistokes)( Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) Without anti stripping agent '(I)' Paving bitumen 60/70 or VG-30 grade Case-I, 19 mm nominal chipping size
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 507. complete in all respect. ( including carriage up to initial lead of 5.0 km from quarry and carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.)'(a) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification) (I)'with 60/70 or VG-30 grade bitumen
Bituminous Concrete (Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) '(a) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification) (I)'with 60/70 or VG-30 grade bitumen ''for Grading-II(13 mm nominal size)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 900mm equilateral triangle
6'Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 00mm equilateral triangle
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 600mm circular
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 5th kilometre stone (precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Ordinary Kilometre stone (Precast)
Road Markers/Road Stud with Lens Reflector Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973 b) Two- way reflective with 2x43 glass elements.
Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m center to center, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanized by hot dip process, all fitting to conform to IS:1367 and IS:1364, metal beam rail to be fixedon the vertical post with a spacer of channel section 150mmX75mmX5mm, 330mm long complete as per clause 810.)
Planting of Trees and their Maintenance for three Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trenches, watering , fixing the tree guatrd and maintaining the plants for three year..
Boulder Appron (In Stretches)
Construction of RCC Open Drain Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202&1203 (A) With crushed Stone I.PCC Grade M10 (ii)nominal mix 1:3:6.
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal steel/Shyam steel/RINL) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 With Crushed Stone a)height up to 5m RCC Grade M 20 Case. I :Using concrete mixture
Construction of RCC Cover Drain Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202&1203. (A) With crushed Stone I.PCC Grade M10 (ii)nominal mix 1:3:6.
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal steel/Shyam steel/RINL) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204.With Crushed Stone a)height up to 5m RCC Grade M 20 Case. I :Using concrete mixture
Construction of Retaining wall 'Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202&1203. (A) With crushed Stone I.PCC Grade M10 (ii)nominal mix 1:3:6.
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204P.C.C. grade M 20 (ii)Nominal mix 1:2:4
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification '(ii) Sandyr material
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Brest Wall of 2.50 M Height Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (for coping on top of the Breast Wall) PCC Grade M 20 Height upto 5m
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III) Random Rubble Masonry In 1:4 cement mortar. In 1:4 cement mortar
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 Granular material
Construction of 1000 mm dia NP4 Hume Pipe Culvert 'Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202&1203 (A) With crushed Stone I.PCC Grade M10 (ii)nominal mix 1:3:6.
Providing and laying reinforced cement concrete pipe NP4 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling,concrete and masonry works in head walls and parapets Clause 1106. 1000mm dia
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 With crushed Stone P.C.C Grade M20 Nominal mix (1:2:4)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204P.C.C. grade M 20 (ii)Nominal mix 1:2:4
Construction of 1 x 3.00 m x 3.00 m RCC Box Cell Culvert Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side Ordinary soil upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10, Nominal mix 1:3:6
Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203 PCC Grade M 20 Nominial mix (1:2:4)
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 With crushed stone,For nominal mix 1:2:4, Height upto 5 M
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Supplying, fitting and placing MS Bar (Fe-500 D) reinforcement bar(From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, & 1203 IV) R.C.C.grade M 20
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A.With crushed stone
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
Construction of 2 x 3.00 m x 3.00 m RCC Box Cell Culvert Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side. Ordinary soil upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10, Nominal mix 1:3:6
Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203 PCC Grade M 20 Nominial mix (1:2:4)
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 With crushed stone, For nominal mix 1:2:4, Height upto 5 M, R.C.C grade M 20
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Supplying, fitting and placing MS Bar (Fe-500 D) reinforcement bar(From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing
Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, & 1203 IV) R.C.C.grade M 20
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 Random rubble masonry in case of stone pitching laid with cement mortar (1:5)
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
Providing bituminous wearing coat comprising of 20 mm thick premix carpet with 5 mm thick seal coat Type B for culverts as per drawing and technical specifications Clauses 1206.2 and 500
Construction of 2 x 5.00 m x 5.00 m RCC Box Cell Culvert 'Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. 'Ordinary soil upto 3 m depth
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. '(I)RCC Grade M20 using concrete mixture.
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork RCC Grade M20. Height up to 5m ,Using concrete mixture.
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 With crushed stone,For nominal mix 1:2:4, Height upto 5 M
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Supplying, fitting and placing MS Bar (Fe-500 D) reinforcement bar(From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
Debajit Deb (BID ID -244887)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid