Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | ₹13.5 L Quoted ₹14.9 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹15.0 L+₹6,810 (0.46%)Rejected-Finance | ₹15.0 L+₹6,810 (0.46%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹18.0 L+₹3.0 L (20.4%)Rejected-Finance | ₹18.0 L+₹3.0 L (20.4%) | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
28 Sept 2024, 6:00 pmClosed
Major S N Gaikwad
Holta Cantt Palampur
REPAIR AND MAINT OF APFC PANELS MCCBs LT OVER HEAD LINE LT SWITCH GEAR SERVO VOLTAGE STABILIZER UPS AND OTHER ALLIED WORKS ALHILAL MIL STN UNDER GE PALAMPUR
2024_MES_668668_1
GEP-26/2024-25
Open Tender
Civil Works
Item Rate
180 days
Alhilal Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹40,000
30 Oct 2024
31 Aug 2024
30 Sept 2024
31 Aug 2024
28 Sept 2024
14 Sept 2024
Amount
Supply and fix and draw ACSR Weasel conductor of size 06 strands of aluminium of 2.59 mm dia and 1 strand of steel of 2.59 mm dia on HT/LT poles, bringing the sag within limit fixing on Insulator/Cross arms by means of necessary binding with 16 SWG aluminium binding wire and providing alkathin pipe of approved quality for jumpers, reconnecting the service connections after removing the carbon material including taking down old UNSV, ACSR conductor of any size & type from LT poles at any height position and place complete all as specified and directed.
M&L GI wire 4mm dia as continuous earth wire, guarding and craddles to OH line including binding wire, including taking out old UNSV damage GI wire complete all as specified and directed.
M&L work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer including taking out old UNSV cross arms complete all as specified and directed.
S&F in replacement steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking out old unsv, RCC/steel pole complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
S&F pin type porcelain vitreous insulator 100 mm height and 65 mm dia for 1100 Volts grade including galvanised mild steel spindle, one nut and two washers & Including taking out old UNSV insulators complete all as specified.
S&F shackle type insulator porcelain vitreous white,brown and green of size 75 mm heaight and 90 mm dia incl galvanised MS straps 31x3 mm size ,washers,insulator bolt 12 mm dia and nut for working pressure 1100 Volts grade & Including taking out old UNSV insulators complete all as specified.
M&L stay asembly comprising of stay bow (4000 x 14mm), stay rod 215 cm long and 16 mm dia with nuts, stay plate 300 x 300 x 6 mm thick and 2 nos of thimble complete as shown in electric plate no 1 of SSR part-1 connected to loop type insulator, including dismantling old UNSV stay assembly complete all as specified and directed. NOTE :- Earth work excavation, concrete and loop type insulator & Stay wire shall be measured and paid separetely under relevent items of Sch 'A'.
Supply and fix LT loop type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of Small size with over all dimensions 65 x 90 mm including dismantling of existing LT loop type insulator from LT poles of any height place and position.
S&F Galvanised stay wire stranded of size 7/4 mm including necessary binding, strengthening complete all as specified and directed.
M&L PCC 1:4:8 type D2 using 40mm thick crushed stone aggregate for foundation of poles/stays complete all as specified and directed.
M&L PCC 1:3:6 type C1 using 20mm thick crushed stone aggregate for coping of HT/LT poles, including necessary form work and finishing exposed surface of concrete even and smooth without using extra cement complete all as specified and directed.
M&L PCC 1:2:4 type B2 using 40mm thick crushed stone aggregate for making good the road cutting complete all as specified and directed.
M&L danger notice plate of 1.6 mm thick mild Steel sheet, vitreous enamelled white, with letters, figures and conventional skull & bones in signal red colour & fixed with MS clamps, bolt,nuts of approved size for LT 20 x 15 cm size including dismantling the old unserviceable one complete all as specified and directed.
M&L preparing old painted surfaces of steel tubular poles sawaged pole of any description and length not exc 7.5 above ground level erected in vertical position in LT OH line including cross arms of angle iron/ channel section clamps brackets etc with one coat of aluminium paint 6.0 mtr from top of the pole onward & remaining with black & Yellow paint strip in 30 cm width alternatively upto ground level & numbering the pole with white paint on black paint base 20 cm dia circular/square shape complete all as specified and directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 120sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 95sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 70sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 50sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 35sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 25sq.mm 4 core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 16sq.mm 4 core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 16sq.mm 2 core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 10sq.mm 4 core including taking out old unserviceable cable complete all as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
All as per item No. 24 here-in-above but exceeding 1.5 mtr but not exceeding 3 mtrs in depth complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
M&L old size brick class "B" as in cable protection laid dry,flat,transversally along the length of cable on sand cushioning with width equalto length of the brick complete all as specified and as directed.
S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
S&F 50mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
S&F 80mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
M&L inspection, checking and repair of APFC panel by cleaning of dust inside with blower, cleaning of moving part/contract from CT cleaner, tightening of loose parts/electrical wiring , cleaning of contractors, relays and capacitor juction points, oiling of cooling fan , complete testing of APFC relay with necessary settings with CTs /load adjustments to match with the APFC load management system complete with replacement of burnt/worn out unserviceable components /burnt wires thimbles /lugs etc for APFC panel capcity 50 KVAR to 150 KVAR complete all as specified and directed. Note : All unserviceable parts shall be measured and paid seprately as supply only. Replacment of small nuts/screws, wires lugs or thimbles and cleaning material cost included in this item.
Supply only MCB, TP 6 to 32 Amp 10 KA C curve for existing APFC panel complete all as specified and directed.
Supply only MCB, TP 40 to 63 Amp 10 KA C curve for existing APFC panel complete all as specified and directed.
Supply only Auxillary contractor 1 NO+1NC TP 415 volts suitable for 10 KVAR rating for existing APFC panel complete all as specified and directed.
Supply only Auxillary contractor 1 NO+1NC TP 415 volts suitable for 20 KVAR rating for existing APFC panel complete all as specified and directed.
Supply only capacitor 440 volts 50 Hz 5 KVAR for existing APFC panel complete all as specified and directed.
Supply only capacitor 440 volts 50 Hz 10 KVAR for existing APFC panel complete all as specified and directed.
Supply only capacitor 440 volts 50 Hz 15 KVAR for existing APFC panel complete all as specified and directed.
Supply only capacitor 440 volts 50 Hz 20 KVAR for existing APFC panel complete all as specified and directed.
Supply only CT's suitable for Ampere meter 100/5A ratio for existing APFC panel complete all as specified and directed.
Supply only CT's suitable for Ampere meter 200/5A ratio for existing APFC panel complete all as specified and directed.
Supply only APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 6 stages for existing APFC panel complete all as specified and directed.
Supply only APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 8 stages for existing APFC panel complete all as specified and directed.
Supply only MCCB, AC, 415volts, 100 Amp, 16KA,4 pole, fixed thermal magnetic release for existing APFC panel complete all as specified and directed.
Supply only MCCB, AC, 415 volts,160 Amp, 25KA, 4 pole, fixed thermal magnetic release for existing APFC panel complete all as specified and directed.
M/S MALHI CONSTRUCTIONS (BID ID -3118449)
somyaenterprises (BID ID -3119427)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .