Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹15.7 L Quoted ₹16.2 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹17.9 L+₹1.7 L (10.6%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹17.9 L+₹1.7 L (10.6%) | L2 | Rejected-AOC not lowest |
| 3 | L3₹18.6 L+₹2.4 L (14.5%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | ₹18.6 L+₹2.4 L (14.5%) | L3 | Rejected-AOC not lowest |
| 4 | L4₹19.0 L+₹2.8 L (17.1%)Rejected-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹19.0 L+₹2.8 L (17.1%) | L4 | Rejected-AOC not lowest |
| 5 | L5₹20.1 L+₹3.9 L (23.9%)Rejected-AOC D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | ₹20.1 L+₹3.9 L (23.9%) | L5 | Rejected-AOC not lowest |
Tender Value
₹32.3 L
EMD Value
₹64,520
Closing Date
14 Sept 2023, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ CWE HILLS, MALL ROAD, DEHRADUN CANTT- 248003
SPECIAL REPAIR / REPLACEMENT OF INTERNAL WIRING AND DBs OF KENDRIYA VIDYALAYA AT MIL STATION RAIWALA.
2023_MES_615831_1
86401/RWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) RAIWAL
Class D Category b(i)
6 documents required · 6 mandatory
₹500
AGE I RAIWALA
₹64,520
Yes
4 Dec 2023
26 Aug 2023
21 Sept 2023
26 Aug 2023
14 Sept 2023
9 Sept 2023
Amount
Dismantling and taking down old unserviceable point wiring of any type (light, fan, socket, power etc) complete with fitting such as switches, sockets, ceiling roses, pendants, lamp holders, light fitting etc including CI/ pressed steel terminals, switch box and making good the disturbed surface of wall/ floor etc to match with the existing surfaces of wall/ floor complete all as specified and directed. Note :- (i) If the contractor fail to make good the disturbed surface of wall/ floor etc and do not match with the existing surface of wall/ floor to the entire satisfaction of Engr-in-Charge, a recovery of @ Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute, the decision of Accepting Officer will be final and binding. (ii) Old fittings/ fixtures / accessories like switches, sockets, lamp holders, regulators etc., if found in serviceable condition shall be removed carefully for reuse in the work or taking on charge. (iii) Only old unserviceable items will be considered in credit Sch.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit "medium grade" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box suitable for modular fixture with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:- Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding.
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
Descrition same all as per item No 2 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
Descrition same all as per item No 2 above, but with 4.0 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
S&F SPN encloser modular type with a two pole and earth plug socket complete, with one SPN MCB 32 amps, 10 KA repturing capacity, 240V AC and ISI marked complete all as specified and directed.
S&F modular switch piano, 1module, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 01 or equivalent of make as specified.
S&F modular switch piano, 1module, flush type button 15/16 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 11 or equivalent of make as specified.
S&F modular socket outlet, 2 module, five pin 2 in 1, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Legrand cat No: 6734 52 or equivalent of make as specified.
S&F modular socket outlet, 2 module, five pin 2 in1, 15 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Legrand cat No: 6734 55 or equivalent of make as specified.
S&F modular fan regulator electronic, 2module, stepped type, suitable for ceiling fans of any capacity, pre-wired 120/ 280 volts AC 50Hz supply 100Watt complete all as specified and directed. Make: Legrand cat No: 6734 30 or equivalent others make as specified.
S&F ceiling rose surface bakelite 65 x 25mm dia three terminals (ISI Marked) complete all as specified and directed. Make – Anchor Jumbo Code-39050 / 3224 or equivalent of make as specified.
S&F angle Lamp holder (with metal ring), insulated body, of PVC/ Polycorbonate with back plate (ISI Marked) suitable for batten fitting with and including one No. 9 watt conventional type LED bulb temp 6500K and lumen out put 950 complete all as specified and as directed. Make– Anchor, Code-39797 or equivalent of make as specified.
S&F LED building security light 1 x 20W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit protection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including making necessary electric connection with 1.5 Sqmm, 3 core, PVC insulated copper conductor cable 1100 Volt grade complete all as specified and as directed. Make:- Crompton Greaves Cat No. TRP-400-20-57-SL-LM-NSR or equivalent of make as specified.
S&F in repair sub main wiring alongwith earth wire (green colour) with single core FRLSH, PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (medium grade) with standard accessories and earth wire connected with main earth dolly, of the following sizes of cable & dia of conduit complete all as specified and directed:- NOTE :- (i) Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and conduit shall be measured as one unit (RM). (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in CM (1:3) including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawal plugs.
2x4 Sqmm + 1x4 Sqmm earth wire with PVC conduit 20mm dia or more
4x4 Sqmm + 2x4 Sqmm earth wire with PVC conduit 25mm dia
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25 mtr depth below ground level at any type of strata with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4) funnel with wire mesh, RCC pit cover of 320 x 320 x 80mm size PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed.
Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 240V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps rating having following capacity complete all as specified and directed:-
DB SPN, 8 way Make :-Legrand Cat Part No- 5076 11 or equivalent others make as specified.
S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 415V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps rating having following capacity complete all as specified and directed:-
DB TPN, 4 way Make : Legrand Cat Part No. 5076 70 or equivalent others make as specified.
S&F connecting & testing sheet metal enclsoure double door type for MCCB DB VTPN 4 way with MCCB 4 pole, adjustable thermal & fixed magnetic type 40-63 Amp, 16 KA, 4 pole MCCB complete all as specified and directed. Note: Set the MCCB as per builidng load and distribute the load before charge the load.
S&F connecting & testing MCB, 230V/ 415V with rupturing capacity 10 KA of following capacity complete all as specified and directed:-
MCB 6 to 32 Amp, SP, 'B' series/ curve, Make :- Legrand, Cat Part No 4024 31 to 4024 36 or equivalent others make as specified.
MCB 6 to 32 Amp, SPN, 'C' series/ curve, Make :- Legrand, Cat Part No 4086 09, 4086 12, 4086 14 to 4086 17 or equivalent others make as specified.
MCB 40 to 63 Amp, TPN, 'C' series/ curve, Make :- Legrand, Cat Part No 4086 81 to 4086 83 or equivalent others make as specified.
Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removal of surplus soil to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose.
M&L for road cutting of size n'exc 20cm width and n'exc 90cm depth for laying of cable including making good the road with PCC (1:2:4) type B2 complete all as specified and directed.
S&F galvanized steel water tubing (GI Pipe) light grade (ISI marked) with all fittings as in sleeving for cable protection & laid in trenches/ floor or fixed to wall, ceiling and pole of following bore complete as specified and directed :- Note : MS Clamp, nut bolts and washer shall be measured and paid seperatly for fixing with pole etc.
50mm bore
Supply and laying cable protection bricks, common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed.
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated, PVC sheathed, steel armoured, aluminum stranded conductor LT UG cable (Conforming to IS 7098), ISI marked, in trenches / ducts / through GI pipes under roads of following size complete all as specified and directed:- Note:- 1. The earth work, GI pipe shall be measured and paid sepretely. 2. Cable may fixing/ passing through pipe laid in trenches or fixed to pole/ wall or fixed to LT panel etc.
95 Sqmm, 3½ core.
50 Sqmm, 3½ core.
16 Sqmm, 2 core.
S&F change over switch, four pole, 415V of following capacity complete all as specified and directed:-
Bedi Refrigeration Works
PARADISE INFRA POWER COMPANY
TARUN ENGINEERING WORKS
M/s Navansh Engineers & Consultants
M/S BABA ENTERPRISES
neeraj electricals
AMAN MATERIAL AND LABOUR CONTRACTOR
anant enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .