Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAccepted-AOC 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹5.3 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹5.5 Cr+₹22.6 L (4.25%)Rejected-Finance | ₹5.5 Cr+₹22.6 L (4.25%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹5.6 Cr+₹24.8 L (4.66%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹5.6 Cr+₹24.8 L (4.66%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹5.7 Cr+₹40.5 L (7.61%)Rejected-Finance | ₹5.7 Cr+₹40.5 L (7.61%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹5.7 Cr+₹41.8 L (7.86%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹5.7 Cr+₹41.8 L (7.86%) | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹7.5 L
Closing Date
11 Dec 2020, 6:00 pmClosed
CE (AF) Gandhinagar
Lekawada Patia Chiloda PO CRPF Campus Gandhinagar 382042
WORK SERVICES FOR ADDL/ ALTN AND IMPROVEMENT TO TECHNICAL ACCOMMODATION AT AFS JODHPUR
2020_MES_383656_2
80306
Open Tender
Civil Works
Lump-sum
540 days
GE (AF) Jodhpur
As per NIT and Tender Document
8 documents required · 8 mandatory
₹3,000
GE (AF) Jodhpur
₹7.5 L
Yes
19 Dec 2020
12 Nov 2020
12 Dec 2020
12 Nov 2020
11 Dec 2020
30 Nov 2020
14 Nov 2020 - 19 Nov 2020
Amount
NOTE: Schedule ‘A’ Part I to XII are under Ser No. 2.00 to 13.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation & Earthwork as listed in Sch `A’ Part II
Lump sum price worked out for Addition/Alteration to Building as listed in Sch `A’ Part III
Lump sum price worked out for Road/Path/Culvert/Hardstanding as listed in Sch `A’ Part IV
Lump sum price worked out for Area Drainage as listed in Sch 'A’ Part V
Lump sum price worked out for Fencing as listed in Sch `A’ Part VI
Lump sum price worked out for Toe/Traverse Wall as listed in Sch `A’ Part VII
Lump sum price worked out for External Water Supply as listed in Sch 'A’ Part VIII
Lump sum price worked out for External Electrification as listed in Sch `A’ Part IX
Lump sum price worked out for Lightening Protection as listed in Sch `A’ Part X
Lump sum price worked out for Fire Alarm System as listed in Sch `A’ Part XI
Lump sum price worked out for Cooling Appliances as listed in Sch `A’ Part XII
ADDITION/ALTERATION TO BUILDING
M & L for applying two coats of fire resistant paint over a coat of red oxide including preparation of new or previously untreated steel surfaces exc 10 cm in width or girth complete all as specified as and directed.
M&L high density polytheene film (transperent colour) in single layer of 400 Micron thickness virgin quality as per ASTMD 2103/IS 2508 laid with side and overlapping not less than 300 mm complete all as specified and as directed.
Dismantling / taking down old existing unserviceale cement plaster loose/unsound weaken cement concrete of any description and in any position from existing external/internal surfaces of RCC slab/RCC beam RCC columns/RCC lintles / RCC fascia/RCC chajjs etc. (up to maximum height 10 meters from natural ground level) with power driven penumetic chisel and including removal of debries outside MoD land complete all as specified and direected.
M&L for removing of cavaties roughening the smooth surface scrapping out/removing corrosion all loose/scale/rust etc from the visible reinforcement by applying rust remover @ 200 ml per sqm or as per manufactures instruction, rust removal and cleaning the steel reinforcement properly and then applying 40 micron thick dry thickness coat of epoxy zinc rich primer @ 250ml per sqm or as per manufacturers insturctions of exposed and new steel reinforcement (measured flat) complete all as specified and direected.
M&L for providing and filling epoxy putty into RCC/PCC/Stone masonry crack after opening up RCC/PCC/Stone masonry cracks in V-groove manner approximte 10mm wide & 10mm deep using mechnical cutter, properly cleaning the same to remove loose dust, dirt etc. and finishing in line and level with existing concrete/masonry surface etc. complete all as per manufacturer instructions and procedures complete all as specified and direected.
M&L for applying two coats of epoxy based two component binder to bind old to new concrete chemical bond as per manufacturer instructions and procedures complete all as specified and direected.
M&L for welding Mild Steel wire mesh weighing not less that 1 kg / sqm and primed with nitco zinc primer, fixing to the prepared concrete surface through proper fixing arrangements and applying 40 mm thick average cement mortar with guniting machine/shotgun at a presure not less than 5 kg/sqm in ratio 1:4 mixed with liquid water proofing compound chemical not less than @ 5% by weight of cement, including lapping of new reinforcement to the rusted portion all as per manufacturer instructions and carried out the work as per procedures complete all as specified and directed. (Reinforcement shall be measured and paid separtely).
M&L for providing rendering 10 mm thick average of cement mortar 1:4 liquid water proofing compound not less that @ 3% by weight of cement all as per manufacturer instructions and procedures complete all as specified and directed.
M&L for applying two coats of epoxy based water proofing and protective coating on newly plastered surfaces all as per manufacturer instructions and procedures complete all as specified and directed.
M&L for providing and applying High performance water based aliphatic protective coating to exposed concrete or masonry surface after proper surface preparation, cleaning of dust dirt etc. system should be application of water based acrylic polymer primer cum sealer coating coverage @ 8-10 sqm/litre/coat on prepared surface and application of 2 coats of water based aliphatic protective coating at 260-280 microns DFT coverage @ 5 Sqm /liter/coat @ 200 microns WFT using suitable brush or roller complete all as specified and directed.
S&F in repairs solid rubber beading of 30 to 50 mm wide and 3 to 5 mm thick fixing at bottom to existing doors complete all as specified and directed.
ROAD/PATH/CULVERT/HARDSTANDING
M & L Wet mix macadam 150 mm thick (75 mm in two layers compacted thickness) laid with coarse aggregate specified in MORTH, spread rolled and consolidated to required gradient and camber complete using mechanical paver asalt of grading 1 (90 to 40 mm sixze) spread, rolled and consolidated to required gradient and camber complete all as specified and directed.
M&L for Forming 25mm thick expansion joint (using diamond cutter) filled with DURA board HD 100(Brand Supreme or equivelant), applying bond breaker tape on top of board for complete width of joint, provision of closed polyurthane backup rod 30mm dia, filled with polyurethane sealent (Min depth of sealent above backup rod shall be 15mm) complies with BS-5212, priming the side and applying masking tape on edges of joint to prevent accidential spillage of sealent and removing the masking tape after sealent is applied complete all as specified and directed.
M&L for Forming construction joint 25 mm deep and 10mm wide (using diamond cutter) and sealed with polyurethane sealent complies with BS:5212 and priming the sides provision of closed cell polyethylene backup rod 12mm dia and applying masking tape on edges of joint to prevent accidential spillage of sealent and removing the masking tape after sealent is applied compleete all as specified.
M&L for Forming contraction (Dummy) joint 100mm deep and 8 mm wide (using diamond cutter) and sealed with polyurethane sealent complise with BS:5212 and priming the sides provison of closed cell polyethylene backup rod 10mm dia and applying masking tape on enges of joint to prevent accidential spillage of sealent and removing the masking tape after is applied complete all as specified and directed.
Painting lines, dashes, arrows, letters, etc., on roads, pavements and the like exc. 10 cm wide with Retro-Reflective Thermoplastic road marking paint, white or golden yellow, conforming to MoRT&H specification all as per manufacturer's specification complete all as specified and directed.
S&F solar road stud having 3 LED's of colours red/yellow/blue/green to a side (total 6 Nos) housed in a tought pressure dia casted aluminium alloy of size 125x125mm of height 20 mm with built in stem nail 37x37x55mm long for fixing with epoxy. LED's solar cells battery & light sensor well protected in side under tough unbreakable poly carbonate transparent sheet roof system workable for 3-4 (nights) after full charge in 8-10 hours by hammering complete all as specified and directed.
S&F directional reflective cay eye of aluminium casted stud 100x100mm having ABS plastic strip containing 43 mini retro-relfective glass beads of colour white/red/yellow a side for fixing with epocy fixing with self built in Nail/stem (CAT PART No. GPL-01-53) complete all as specified and directed.
S&F high intensity prismatic dual directional delinator having 100 mm dia HIP sheet reflector (red/yellow/white) held in strong ABS plastic body mounted over CRC steel tube 47 mm dia of 16 gauge sheet support of total height 600 mm having flared/welded foot for firm grip to base. hip reflector and ABS body protected in a welded mesh cage. jall. steel parts stove enamelled and baked to 120 C or powder ocated to make all weather resistant . vertical support tube too have a HIP sheet reflector all around (CAT PART No. GPL-11-06) and embedded in PCC block 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) incl necessary form work of side less than 8 mm complete all as specified and directed.
FENCING
S&F galvanised steel punched type concertina coil of 1050 mm dia (Dia of coil unstratched and fixed to angle iron posts/struts with 3.15 mm dia GI wire complete all as specified and as directed.
EXTERNAL WATER SUPPLY
Supply and fix sluice valve CI body of size 80 mm (3”) dia , class PN 1.6, IS 14846-2000 with spindle (heavy duty) both ends flanged with brass spindle and brass check nuts with CI hand wheel including jointing material like rubber insertion sheet 3 mm thick, bolts, nuts and fixed to pipe line and testing complete all as specified and as directed.
Supply and fix sluice valve CI body of size 80 mm (2”) dia , class PN 1.6, IS 14846-2000 with spindle (heavy duty) both ends flanged with brass spindle and brass check nuts with CI hand wheel including jointing material like rubber insertion sheet 3 mm thick, bolts, nuts and fixed to pipe line and testing complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
Taking out old LT U/S cable of any size
Taking down old MCCB,s of any capacity
Taking down old MCB of any capacity.
Taking down poles of any type.
Taking out existing HPSV/MH/ flood light of 90/10/120/150 W capacity with built in control box /unsv street LIGHT/flame proof light
Taking out old LT panel ,bus baar panel
Taking out old point wiring of any size any type
Taking out OLD DB box with all MCBs
Shifting of transformer inside the permises of air force station of capacity 100kva including all accessories and T&P directed as per Engr in charge.
Supply & Installation of 11 KV Outdoor type extensible 02 way Load break switch floor mounted with internal copper bus bars, consisting of 01 no incoming 630 Amp fixed manual Load Break Switch and 01 no outgoing fixed manual Load Break Switch. All live parts, bus bars, LBSs connections of LBS should be enclosed in one tank (Minimum 2 Modules) to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank of 3 +/-0.5mm thick having IP67 degree of protection filled with gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. LBS should complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar :
1 st Incoming Load Break Switch module should consist of following accessories :- 630A Load Break Switch module for making and breaking of fault current alongwith Earth Swicth of full making capacity Short time current - 20KA/ 3 sec Making Capacity - 50KA Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 28KV Impulse withstand voltage - 75KV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Internal arc type tested for 20kA for 1 sec Snap action mechanism for manual operation Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable Right angle boots (push on type) Suitable Cable bushings for front only cable terminations Arc proof cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 Ronis Key Interlock Mechanical Indications for Load break switch ON, OFF, EARTH
Outgoing Load Break Switch module should consist of following accessories :- 630A Load Break Switch module for making and breaking of fault current alongwith Earth Swicth of full making capacity Short time current - 20KA/ 3 sec Making Capacity - 50KA Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 28KV Impulse withstand voltage - 75KV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Internal arc type tested for 20kA for 1 sec Snap action mechanism for manual operation Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable Right angle boots (push on type) Suitable Cable bushings for front only cable terminations Arc proof cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 Mechanical Indications for Load break switch ON, OFF, EARTH
Supply, Installaton, Testing and Commissioning of cubical type dust and vermin proof IP66 outdoor type LT panel with ribbed type external surface, made of high quality CRCA 3.15MM characterised MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site comp;lete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc. pannel size should be 1.6M*1.2M*.35M, for lifting 4 hook should be provided at top of panel consisting of following:-
Supply, Installaton, Testing and Commissioning of cubical type dust and vermin proof IP66 outdoor type LT panel with ribbed type external surface, made of high quality CRCA 3.15MM characterised MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site complete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc. pannel size should be 1.6M*1.2M*.35M, for lifting 4 hook should be provided at top of panel consisting of following:-
(a) Bus bars of aluminium strips 600 Amp current rating capacity, minimum 600 mm long or of length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator - 01 set (a) MCCB 400 Amps TPN 36 KA, 415 V - 01 No. for incoming. (b) MCCB 250 Amps TPN 36 KA, 415 V - 01 No. Outgoing (C) MCCB 160 Amps TPN 25KA, 415 V (d) MCCB 40A Amps TPN 25 KA 415 Volts (E) MCB 32 Amps TPN 10 KA 415 Volts (j) LED type indicator lamp Red/ Yellow/ Blue colour-03 Nos (k) Internal wiring with copper conductor incl necessary lugs and thimbles 1 Job (L) pannel should comsist of emergency power off/kill switch facility
Supply, Installaton, Testing and Commissioning of cubical type dust and vermin proof IP66 outdoor type LT panel with ribbed type external surface, made of high quality CRCA 3.15MM characterised MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site complete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc. pannel size should be 1.6M*1.2M*.35M, for lifting 4 hook should be provided at top of panel consisting of following :-
Supply, Installaton, Testing and Commissioning of cubical type dust and vermin proof IP66 outdoor type LT panel with ribbed type external surface, made of high quality CRCA 3.15MM characterised MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site complete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc. pannel size should be 1.6M*1.2M*.35M, for lifting 4 hook should be provided at top of panel consisting of following:-
(a) Bus bars of aluminium strips of 300 Amp current rating capacity, minimum 600 mm long or of length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator - 01 set (a) MCCB 250 Amps TPN 36 KA, 415 V - 01 No. Incoming (b) MCCB 125 Amps TPN 25KA, 415 V (C) MCCB 100 Amps TPN 25KA, 415 V (d) MCB 32 Amps TPN 10 KA 415 Volts (j) LED type indicator lamp Red/ Yellow/ Blue colour-03 Nos (k) Internal wiring with copper conductor incl necessary lugs and thimbles 1 Job (l) pannel should consist of emergency power off/kill switch facility
Supply, Installaton, Testing and Commissioning of cubical type dust and vermin proof IP66 outdoor type LT panel with ribbed type external surface, made of high quality CRCA 3.15MM characterised MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site complete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc. pannel size should be 1.6M*1.2M*.35M, for lifting 4 hook should be provided at top of panel consisting of following:-
(a) Bus bars of aluminium strips of 300 Amp current rating capacity, minimum 600 mm long or of length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator - 01 set (b) MCCB 250 Amps TPN 36 KA, 415 V - 01 No. Incoming (c) MCCB 125 Amps TPN 25KA, 415 V (d) MCCB 100 Amps TPN 25KA, 415 V (e) MCCB 40A Amps TPN 25 KA 415 Volts (f) MCB 32 Amps TPN 10 KA 415 Volts (g) LED type indicator lamp Red/ Yellow/ Blue colour-03 Nos (h) Internal wiring with copper conductor incl necessary lugs and thimbles 1 Job (i) pannel should consist of emergency power off/kill switch facility
----ditto----- above but 100 Amps aluminium bus bar with below mentioned items panel size should be .9M*.96M*.35M for lifting 4 hook should be provided at top of panel consisting of following:-
Supply and fix LED street light 120 W IP 66 .
Supply and fix LED Flood light 120 W IP 66.
Supply and fix street light juction box of PVC make sintex junction box consisting of 01 No MCB 10 Amps, 10 KA capacity (3 phase and neutral) including aluminium strip bus bar for incoming and outgoing cable with necessary connection duly fixed on the pole with suitable size of MS clamp as approved and directed.300x200x105mm.
Material and labour for stone slab/patti, 40 to 50mm thick, rough dressed, Jodhpur stone slab cover in trenches for protection of cables, 25mm to 35mm wide and 80 cm long, laid dry abutting each other with gap between adjacent slab not exceeding 10mm complete all as specified and directed.
M&L for LT Feeder Pillar ( Kiosk)of size not less than 60 cmx 22 cm x45 cm made out 2 mm thick out door type CPRI approved) with openable Front door including locking arrangement with copper bus bar 200 amps rating and 125 AMP 4 pole MCCB and fixed on angle iron frame and PCC plinth complete all as specified and directed.
Boring of holes under road, pavement, hard standing through manual process and protection pipe of 80mm for cable made GI light grade type complete all as specified and directed.
Supply and fix Flame proof weather proof enclosure suitable for LED tube light fitting including lamp (Tube) 1 x 36/40 watt 230 volt 5700 CCRT lumen efficiency not less than 100 lumen/watt PF 0.8 with aluminium cast alloy LM6 insde and out side light gray epoxy coating prewired all accessories fixed on wall or on ceiling including mounting stand and connecting up complete with 23/0.0076 flexible 3 core copper cable in flexible steel conduit with flame proof cable gland complete all as specified and directed.
Supply and fix Flame proof - weather proof flood light fitting suitable for and including 90 watt LED complete all as specified and directed.
Dismantling and taking down the flame proof weather proof fluorescent fixture 1 x 40 W x 4' and refixing the same after cleaning and repair complete all as specified and directed.
Dismantling and taking down the flame proof weather proof fluorescent fixture 2 x 40 W x 4' and refixing the same after cleaning and repair complete all as specified and directed.
Dismantling and taking down the flame proof weather proof flood light fitting suitable for 500W GLS/400W HPMV/400W metal halide and refixing the same after cleaning and repair complete all as specified and directed.
M & L for SUBMAIN wiring complete with two single core runs of 1.5 Sqmm PVC insulated FRLS Copper conductor including stove enamelled steel Conduits surface/Concealled/flexible steel conduit(20mm size) incl all accessories like bends,tees and jointing plate pressed steel terminal sunken boxes 2 mm thick duly electroplated with 3 mm thick plastic laminated sheet for mounting of switches sockets, regulators etc including 1.5 sqmm PVC insulated FRLSH copper conductor used as earth wire for including making disturbed surface good to existing with surfaced colour for One flame proof light/fan point controlled by one flame proof rotary switch one way complete all as specified and directed.
M & L for SUBMAIN wiring complete with two single core runs of 2.5 Sqmm PVC insulated FRLSH Copper conductor including stove enamelled steel Conduits surface/Concealled /flexible steel conduit(20mm) incl all accessories like bends,tees and jointing plate pressed steel terminal sunken boxes 2 mm thick duly electroplated with 3 mm thick plastic laminated sheet for mounting of switches sockets, regulators etc including 2.5 sqmm PVC insulated FR LS copper conductor used as earth wire for including making disturbed surface good to existing with surfaced colour for 15 Amps socket point controlled by one flame proof rotary switch one way complete all as specified and directed.
Supply and fix Flame proof - weather proof switch socket & plug combined 16 A, 500 V(3P+Earth) complete all as specified and directed.
S&F in repair flame proof exhaust fan of 450 mm sweep 230 v incl fasteners and making good surfacecomplete all as specified and directed.
S&F in repair metal box suitable for fixing of flame proof rotary switches of size not less than 450mmX350mmX200 mm , 2mm thick incl powder coated complete all as specified and directed.The rate include for taking out/refixing switches after fixing of metal box complete all as specified and directed.
S&F Flame proof in repair SPN DBs 8 way Ekinoxe with metal door IP 54 protection fixed MCB SPN 32 amps 01 Nos and MCB SP 6 to 30 amps 6 Nos complete all as specified and directed.
S&F Flame proof in repair TPN DBs 4 way Ekinoxe with metal door IP 54 protection fixed MCB TPN 63 amps 01 Nos and MCB SP 6 to 30 amps 12 Nos complete on pillars with MS clamps etc including electric connections complete all as specified and directed.
Supply and lay stone aggregate of size 40mm graded layed on ground of two/four pole structure by cleaning area by surface dressing / cutting of foreign material/vegitation and filling all cavities of aggregate with lime layer etc complete all as specified and directed.
Supply and lay stone aggregate of size 20mm graded layed on ground of two/four pole structure by cleaning area by surface dressing / cutting of foreign material/vegitation and filling all cavities of aggregate with lime layer etc complete all as specified and directed.
LIGHTENING PROTECTION
Taking down ols U/S earthing strips of any size/any type complete all as specified and directed.
Supply and fix ACSR lines on existing poles with ACSR conductors size 2 of 6/1x2.11mm(Squirrel) complete all as specified and directed.
Taking out copper strip and refix as it was on their locatons with all complete accessories.
COOLING APPLIANCES
M&L for PVC rigid pipe of 20mm bore flushed in water /floor drain out the condensed water from the cooling unit complete all as specified and directed.
Supply ,installation ,testing of voltage stabilizer 5KVA copper wound for automatic operation single phase 230V,50 C/S with in coming voltage 170 to 280Volt stabilized 200 to 230Volt complete all as specified and directed.
.M&L for MS work in canopy with frame for mounting the condensing unit of AC fabricated from angle ,flats,nuts and bolts, MS sheet ,weld mesh etc .all as specified including painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
HUMIDIFIER
Suppy, Installation, Testing and Commissioning of desiccant dehumidiifer compleate with metal-silicate based desiccant rotor. Rotor should be placed horizontal. Rotor should have organic compound less than 2%. Rotor should be adsorbent, non-toxic, non-flambale, fully water-washable. Rotor should have perimeter flange, and teeth around perimeter flange to ensure a positive and slip-free rotation. Rotor should be made in India. Dehumidifier should have process blower, process motor, process filter, reactivation blower, reactivation motor, reactivation filter, reactivation electric heater, rotor drive motor, thermostat, humidistat and in-built MCB. The dehumidiifer casing should be industrial design, CNC fabricated from heavy guage sheet. It should be powder coated. BRY-AIR MAKE FFB1500:- 900 CMH Process-air @ 250 Pa ESP. Reactivation heater: 18 KW. Input Power Supply: Three-Phase, 415 V, 50 Hz. Humidistat: Digital with controller. Make: Hygro Tech/Condair as approved by GE.
All as per item No.78 but capacity FFB1000:- 600CMH Process-air @ 200 Pa ESP. Reactivation heater: 12 KW. Input Power Supply: Three-Phase, 415 V, 50 Hz. Humidistat: Digital with controller.Make: Hygro Tech/Condair as approved by GE.
All as per item No.78 but capacity FFB170:- 100 CMH Process-air @ 120 Pa ESP. Reactivation heater: 2.3 KW. Input Power Supply: Three-Phase, 415 V, 50 Hz. Humidistat: Digital with controller.Make: Hygro Tech/Condair as approved by GE.
Providing and fixing of flexible PVC hose pipe of 200mm diameter for providing process inlet air/process outlet air or reactivation inlet air/reactivation outlet air to the given room/lab for various equipment through walls/ceiling with appropriate clamps & fixing arrangement as per client requirement complete all as specified and directed.
Providing and Fixing of bird gauge with specific clamp of 200mm diameter for PVC hose pipe of process inlet air/process outlet air or reactivation inlet air/reactivation outlet air to the given room/lab complete all as specified and directed.
Sch of credit Rs 5,11,050.00
Jeet Construction
FRIZO INDIA PVT LTD
MADAN MOHAN JAIN sons
JASRAJ AND COMPANY
Jagdish Prashad and Company
Brahma Infra
Bidder Name
JASRAJ AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .