Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.3 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹45.4 L+₹6.4 L (16.3%)Rejected-AOC | 2 | Rejected-AOC L2 BIDDER | |
| 3 | 3₹46.9 L+₹7.9 L (20.2%)Rejected-AOC 15 JOGENDRA NATH GHOSAL ROAD P S BELGARIA KOLKATA 700 057 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700057 | 3 | Rejected-AOC L3 BIDDER | |
| 4 | 4₹47.0 L+₹8.0 L (20.5%)Rejected-AOC | 4 | Rejected-AOC L4 BIDDER | |
| 5 | 5₹48.7 L+₹9.7 L (24.9%)Rejected-AOC | 5 | Rejected-AOC L5 BIDDER |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
30 Sept 2023, 5:00 pmClosed
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
COMPREHENSIVE MAINT OF FLOOR ROOF CEILING COLUMNS JOINERY CHAJJA FAINS FACIAS LEAKAGE SEEPAGE PLASTERING DOOR WINDOW VENTILATORS GRILLS GUARDS BARS PLUMBING STRUCTURAL REPAIRS SMART PERIODICAL SERVICES SEWAGE LINE SEPTIC TANK AND INTERNAL ELECTRIFICA
2023_MES_616614_1
8297/23-24/GE(N)/KOL/E8 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
210 days
ATCQA(SA)
AS PER TENDERDOCUMENT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹73,000
Yes
20 Oct 2023
31 Aug 2023
2 Oct 2023
1 Sept 2023
30 Sept 2023
14 Sept 2023
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off premises complete all as specified and directed.
M & L for Non-skid ceramic colour tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc over and including 15 mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade / colour / matrix of the tiles complete all as specified and directed.
All as per Item No 2 above but as in skirting/dado but over 10 mm thick bedding layer of mortar in CM 1:4 complete all as specified and directed.
M&L for vitrified ceramic tile 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors laid over & including 15 mm thick screed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of floorcomplete all as specified and directed.
All as per Item No. 5 above but in skirting/dado but over 10 mm thick bedding layer of mortar in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic colour tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in colour cement to matc over and including 10mm thick bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade / colour / matrix of the tiles complete all as specified and directed.
Dismantling of stone slabs and tiles, laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed.
M&L for 25mm thick pre-polish coloured chequered smooth finish exterior grade precast heavy duty shine finish paver tiles as approved, set, jointed and pointed with grey cement and pigment over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and directed.
M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing etc. over and including 20mm thick screed bed in CM (1:4) complete all as specified and directed.
M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete etc. over 10 mm thick bedding layer in CM (1:4) complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, with grey cement and no pigment complete all as specified and directed.
M&L for 50mm thick sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. Note: Punned down thickness shall be measured and paid.
Dismantling wall and ceiling boards (fibre pulp or insulation etc) any thickness including cover fillet complete all as specified and directed.
S&F Non-asbestos ceiling board 0.60 X 0.60 mtr X 6 mm thick Ocenic brand of averest or equvalent fixed with powder coated GI framing including drilling hole for fixing GI frame including Gi wire suspender complete all as specified and directed.
S&F GI powder coated snap grid frame work of size 600x600 mm comprising with GI powder coated Angle & Tee including the above grid suspended at every 1200mm c/c in both directions using 2.5 to 3 mm dia pre straightened adjustable G.I Wire or G.I Rod fixed to Roof using 6mm Nylon Rawal Plug and Eye Hook or L Cleat or as per direction by maufacturer complete all as specified and directed.
S&F venetian blinds, made of 100% polyester woven fabric, assembled on powder coated top channel with high quality darting runners, nylon spacers with filter mechanism, nylon headed filter chain, nylon cord etc. the bottom of the fabric has a weight made of MS and are connected with nylon beaded link complete all as specified and directed.
M&L for removing of plants & shrubs girth not less than 3 cm including roots by dismentaling of brick work, PCC/RCC work including necessary scaffolding any type in any location/position i.e. roof, parapet wall, near pipes etc after removal of roots trees,scrubs etc from any location of wall and making good to the disturbed portion using PCC (1:2:4) type B-0 and 10mm thick plaster in CM (1:3) including applying acid after removing roots for preventing the regrowth complete all as specified and directed.
Dismantling/ Taking down of existing roof treatment including layer of bitumen felt, concrete padding and benching including hacking for key, scrubbing down with water complete to receive new roof treatment including rubbish off the factory premises and removing to distance 0.5 km to 1.5 km complete all as specified and directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand 1:1 (by weight) complete all as specified and directed.
M&L for cement concrete 50mm thick, (1:2:4) type B-0 (using 12.50 mm graded aggregate) for padding complete all as specified and directed.
M&L for applying water proofing treatment as follows:- (a) 15mm cement plaster with cement mortar (1:4) on roof surfaces using liquid integral WPC @ 3% total weight of the cement complete all as specified and directed. (Note: WPC paid Separately) (b) Applying a coat of bitumen primer @ 0.40 Kg/Sqm on prepared surface of plaster and applying a coat of bitumen 85/25 grade @1.2kg/Sqm complete all as specified and directed. (c) Applying APP based polymeric membrane minimum weight 3.50 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric/wt not less than 150 gm/Sqm and sealing joints by torched application bitumen complete all as specified and directed.
M&L for 40mm thick brick tiles terracing over and including bedding layer of cement mortar (1:6), 15mm thick, including jointed and grouted in cement mortar (1:6), flush pointing in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in benching on chajja, parapet wall and sides of wall etc. including necessary formwork complete all as specified and directed.
Demolition of concrete in ground floor & paving not exc 15 cm thick (above or below GL) complete all as specified and directed.
M&L for 100mm thick cement concrete (1:4:8) type- D2 (using 40 mm graded stone aggregate) as in sub base of floor.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) finished even & smooth without using extra cement as in plinth protection including bitumen/mast filling in the joint complete all as specified and directed.
Demolition of brick work built in cement mortar including all quions arches, pillars etc but excluding ashalar facing dressed stone and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for reinforced cement concrete (1:1.5:3), type A1, (using 20 mm graded stone aggregate) as in copings rounded or chamfered on edges etc complete all as specified and directed. Note : Reinforcement and formwork shall be measured and paid separately.
Taking down cement plaster, any description from brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, including taking down roots of trees complete all as specified and directed.
M&L for rendering 10 mm thick on brick or concrete wall surfaces in CM (1:6), finished even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying with three coat of white wash on wall surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of OBD over a coat of alkali resistant primer complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work on concrete surfaces, 5mm thick cement plaster using water proofing compound @ 3% by weight of cement over 10mm cement plaster finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
M&L for applying two coats of 100% premium acrylic emulsion paint over new surfaces having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.
M&L for rendering 5 mm thick in CM (1:3) on ceilling finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for applying one coat of white wash on old decorated ceiling surface including preparation of old surfaces & filling cracks and holes with white cement based putty or cement mortar (1:2) complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of walls etc by complete removal of existing treatment including washing, rubbing down and stopping of surface and applying two coats of oil emulsion distemper on wall surfaces complete all as specified and directed.
M&L applying wall care putty 1mm thick on wall / ceiling finished even and smooth complete all as specified and directed.
M&L for applying one coat of distemper oil emulsion on old decorated wall surfaces including preparation of old surfaces over 1 mm thick wall care putty complete all as specified and directed.
M&L for applying one coat of distemper oil emulsion on old decorated ceiling surfaces including preparation of old surfaces of ceiling & filling cracks and holes with white cement based putty complete all as specified and directed.
M&L for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint (1st grade quality) complete all as specified and as directed.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint (1st grade quality) complete all as specified and directed.
Taking down door /window frame with shutter (without taking off shutter from the frame) area not exc 1.5 sqm complete all as specified and directed.
Taking down door / window frame with shutter (without taking off shutter from the frame) area exc 1.5 but n exc 4sqm complete all as specified and directed.
Taking down shutters area exc 1.00 sqm but not exc 2.00 sqm complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed.
Taking down and refixing shutters of any description exc 1 sq. m each n exc 2 sqm each in the same opening complete all as specified and directed.
S&F pressed steel frames, size 105 x 60mm, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
M&L for 2nd class hard wood for plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints fixing of hold fast size 25 x 5 mm of flat iron etc supplied and fixed complete all as specified and directed.
M&L for 35mm glazed and skelton shutters open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24(a) supplied and fitted to chowkats in second class hard wood complete all as specified and directed.
S&F 35 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both side including both faces covered with decorative face veneer with lipping/frame to match complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid PVC moulded Door Shutter, with wood free EPS 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 95mm made out of 5mm wood grain printed colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F factory made solid panel Prelaminated PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both face prelaminated PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of prelaminated PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S & F solid PVC wall lining consisting of 5mm thick coloured PVC sheet inclusive of solvent cement and preparing existing surface and fixing at site on as cupboard etc complete all as specified and directed.
S & F for 18 mm thick coloured solid PVC sheet suitably fixed as per direction and specifications complete all as specified and directed.
S & F for 12 mm thick coloured solid PVC sheet suitably fixed as per direction and specifications complete all as specified and directed.
S&F 125 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 125 mm long aluminium anodised handle cast type complete all as specified and directed.
S&F 150 mm long aluminium anodised handle cast type complete all as specified and directed.
S&F butt hinges of size 100 mm, medium weight, stainless steel min 3 mm thick for doors complete all as specified and directed.
All as per Item No. 67 above but of size 75 mm L-type complete all as specified and directed
S&F stainless steel pressed handles, oval type, designer of 150 mm size for doors complete all as specified and directed.
S&F 300mm aluminium anodised sliding door bolts with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast alumnium alloy complete all as specified and directed.
S&F 100mm size designer stainless steel handles, fixing with screw complete all as specified and directed.
S&F Hasp and staple safety type stainless steel with steel hinge pin including bolt to hinge plate of 100mm size and fixed with screws complete all as specified and directed.
Taking down existing aluminium door and carrying out all necessary repair work including tightening, adjusting and replacement of hinges, screw, aluminium tower bolt and refixing in the same opening complete all as specified and directed.
Hacking out old broken glass any thickness size and quality from wooden/ steel frames etc complete all as specified and directed.
S & F 3.0 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 sqm in each pane etc complete all as specified and directed.
S & F 3.0mm thick figured glass pin headed type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and directed.
S&F 150mm overall length cover plate for floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in floor complete all as specified and directed.
S&F in repairs door closer, aluminium (extruded section body), hydraulically regulated, designation No, 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying 2 coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges peg stay to receive glazing or gauzing and including handle, both side one coat of primer including fixing of hold fast size 25 x 5 mm of flat iron etc complete all as specified and directed.
S&F steel window with side hung shutters including projecting or box type hinges with steel handle peg stay and divided into square with glazing bars dovetailed or welded, to receive glazing, or gauzing including one coat of primer complete all as specified and directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe. 290 Gde-E-165 complete all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over red oxide zinc chrome primer complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
S&F 18/19 mm thick prelaminated particle board, interior grade prelaminated one side decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
S&F 6mm plywood grade BWR type BB, fixed with screws to timber frame in wall complete all as specified and directed.
S&F 12 mm perforated particle board for insulation and acoustic purpose, 600x600mm in size, fixed with nails to timber frame work or with staples on snap grid in wall etc. complete all as specified and directed.
S&F 6mm plywood grade BWR type BB, fixed with screws to timber frame in ceiling complete all as specified and directed.
S&F 12mm perforated particle board for insulation and acoustic purpose, 600x600mm in size, fixed with nails to timber frame work or with staples on snap grid etc in ceiling complete all as specified and directed.
S&F compacted grass board of 18mm thick of size 600mmx1200mm fixing with nails to wall and ceiling etc complete all as specified and directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and including removal of rubbish off premises complete all as specified and directed.
M&L for RCC nominal mix (1:1.5:3) type A1 (using 20mm graded stone aggregates) as in chajja complete all as specified and directed. (Note:- Formwork and reinforcement shall be measured and paid separately)
M&L for precast RCC (1:1.5:3) Type A1 (using 20 mm graded stone aggregate) as in perforated drain covers and manholes covers including formwork etc. including setting in CM (1:4) complete all as specified and directed.
M&L for use & waste of formwork to chajja's, flat and other for rough finished surfaces complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) and benching for manhole including necessary formwork complete all as specified and directed.
M&L for TMT bars 10mm dia and over upto and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Dismanting wrought iron for or mild steel work of any description not otherwise provided for etc complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 0.50mm thick GI coloured coated sheet as valley gutter made to shape as required complete all as specified and directed.
S&F hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F MS angle in roof trusses Fe 410 W in ( grade Fe 410 W Grade E-250 quality B) complete using ERW or induction purlins etc welded conforming to IS 1161-1979 complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in back filling in pressed steel door frame, holdfasts etc. complete all as specified and directed.
Taking up or down 15mm bore steel water tubing and connections including cleaning for refixing or removal to stores complete all as specified and directed.
Refixing old GI tubing 15 mm bore obtained from Item No. 106 above with all fittings and fixed to wall complete all as specified and directed.
S&F 15mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Taking up or down 20mm bore steel water tubing and connections including cleaning for refixing or removal to stores complete all as specified and directed.
Refixing old GI tubing 20 mm bore obtained from Item No. 109 above with all fittings and fixed to wall complete all as specified and directed.
S&F 20mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair bib tap 15 mm bore cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore chromium plated fancy type stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fix vitreous china squatting pan ' Orissa pattern ' size 580 x 440 mm white with 'P' or 'S' trap , front or back inlet with integral foot rests excluding flushing cistern and flush pipe and making good to floor complete all as specified and directed.
S&F in repair toilet paper holder of brass, chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F vitreous china wash down water closet pan of padestal pattern, white, with P or S trap including connecting to trap and to flushing pipe etc and (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S&F in repairs plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair PVC valveless syphonic action type low level flushing cistern 10 ltr, white with inlet ball valve float and handle including bracket with flush pipe of polythene of low or high density 32 mm bore complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B0 (using 12.50 mm graded stone aggregate) as in sunken floor using liquid integral WPC @ 3% total weight of the cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for two coats of brush bond liquid compound of fosroc or its equivalent water proofing coating over plastered surfaces of sunken portion Make- Fosroc chemical Ltd complete all as per manufacturer instructions.
S&F in repair 40 mm dia GI pipe medium garde spout to WC & Bath including cutting/ making holes through wall complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F PVC (SWR) 110 mm bore pipes single socket, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) 110 mm bore Pipes single socket ,in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) 110mm bends any radius complete all as specified and directed.
S&F PVC (SWR)110 mm bore branch piece ,single socketed (Single Y) equal or unequal complete all as specified and directed.
S&F in repair PVC Shoe of 75mm dia complete all as specified and directed.
S&F in repair vitreous China Urinal, Half stall type, white type complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed.
S&F in repair 15mm dia fancy type pillar tap, cast copper alloy, with capstan heads, chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shank and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair Viterous china wash hand basin, white, flat back, size (630x450mm) excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.
S&F in repair towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleats. (Minimum weight 190gms) complete all as specified and directed.
S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen with waste fitting plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size (915mm x 460mm) bowl size (410mm x 330mm x160mm) complete all as specified and directed.
S&F in repair 40mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F in repair low density PVC pipe 40 mm dia as in waste pipe to sink and wash basin complete all as specified and directed.
S&F in repair 32/ 40mm PVC (flexible) waste pipe, 1200mm long complete all as specified and directed.
S&F in repair 75mm Nahani trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregates) including jointing only cast iron pipes and fittings or AC pipes and fittings, in repairs, with cement joints complete all as specified and directed.
S&F in repair PVC (SWR) gully trap 125/110mm, setting and jointed with solvent cement complete all as specified and directed.
S&F in repair PVC connection 15 mm dia, 450 mm long including brass flynuts at both ends etc. complete all as specified and directed.
S&F in repair 125mm size brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair swivel shower of PTMT any colour for fixing with 15mm pipe (Min weight 40 gms) complete all as specified and directed.
S&F in repair shower arm 15mm size, 195 mm long, with bend of 45 degree with flange of PTMT any colour (Min wt 40 Gms) complete all as specified and directed.
Dismantling of water tank n. exc 500 ltr of any description and removing to store complete all as specified and directed.
Dismantling of water tank exc 500 ltr and n. exc 1000 ltr of any description and removing to store of any description complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 ltr (multi-layered) hoisted and fixed in position including brass ball valve 20mm complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 ltr (multi-layered) hoisted and fixed in position incl brass ball valve 20mm complete all as specified and directed.
Disconnecting existing tanks (exc 250 ltr n exc 500 ltr), setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position and cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes,etc. complete all as specified and directed.
Disconnecting existing tanks (exc 500 ltr n exc 1000 ltr), setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position and cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes,etc. complete all as specified and directed.
S&F in repair 15mm bore gun metal gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 40mm bore gun metal gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 25mm bore gun metal gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair Ball brass valves 20mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repairs grating doom 100mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed.
S&F in repair chromium plated gratings size 75/100 mm with waste hole complete all as specified & directed.
S&F in repair chromium plated Gratings size 100/125 mm complete all as specified & directed.
S&F in repair cover suitable for 500ltr capacity water storage tank complete all as specified and directed.
Excavation of mud/ soft/ loose soils in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, drain, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and directed. Note :- 1. During excavation if any damage occurs to the water supply pipe etc., the contractor will have to get it repaired/ replaced at his own cost and and nothing extra shall be payble on this account.
M&L for concrete bed to drain pipe including packing under haunching against the sides of pipe after they are laid and tested for 150mm bore pipe using cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) complete all as specified and directed.
M&L for concrete bed to drain pipe including packing under haunching against the sides of pipe after they are laid and tested for 100mm bore pipe using cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) complete all as specified and directed.
M&L for 150mm dia (internal dia) salt glazed stone ware drain pipes grade A laid in trenches jointed in CM (1:1) and tested complete all as specified and directed.
M&L for 100mm dia (internal dia) salt glazed stone ware drain pipes grade A laid in trenches jointed in CM (1:1) and tested complete all as specified and directed.
Returning, filling in including spreading leveling, watering and well ramming in layers n.exc 25 cm of soil complete all as specified & directed.
Removing surplus soil to a distance exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius and built in CM (1:6) complete all as specified and directed.
All as per Item No. 166 above but except brick. Note: Serviceable bricks obtained from Item No. 165 above shall be reused.
Material and labour for 15 mm thick rendering in CM (1:4) in two layers, i.e 10mm thick in bottom layer, and 05 mm thick top layer mixed with integral water proofing liquid admixture as per manufacturers instruction on brick or concrete surfaces of wall finished the surface fair and even complete all as specified and as directed. Note :- WPC shall be measured and paid separately.
M&L for 15mm thick rendering on concrete surface/ brick surface in cement mortar (1:4) surface finished even and fair mixed with liquid WPC as per manufacturer's instructions including taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc all as directed, rubbish of the premises complete all as specified and directed. (Note : Rate of WPC deemed to be included in quoted rate).
M&L for cleaning and removing of sludge, soil, mud etc from sewage pipe lines upto 600mm bore pipe by pumping method including manholes by rodding using MS rod tied with jute/ gunny bags between manholes to manholes and flushing down with water complete all as specified and directed. (Note : Sludge / night soil may be taken out by mechenical means and remove outside of defence land )
Taking out manhole cover slab, cleaning of manholes depth upto 1.5 metre by removing all silt, mud, sludge, any other materials, flushing with water to ensure clean, reset the manhole cover in same position after cleaning and testing, removal of spoils/ sludge outside MD land complete all as specified and directed.
M&L for taking out sludge from septic tank of any size and depth complete all as specified and directed. (Note : Sludge / night soil may be taken out by mechenical means and removed outside of defence land)
M&L for cleaning of drain having inner width upto 0.6m and depth upto 1.2 metre by removing mud, garbage, debries, sludge, vegetation etc. having average depth 0.45 m through manually or machnically rubbish off the premises beyond MOD land complete all as specified and directed.
Demolition of reinforced cement concrete as in manhole cover and similar work n.exc 15cm thick and removal of rubbish beyond MOD land complete all as specified and directed.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for providing precast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in manhole cover slabs and similar work round square or rectangular in shape and set in CM (1:4) complete all as specified and directed. Note : All manhole covers to be embossed with Month & year of casting.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including rubbish off the premises complete all as specified and directed.
M&L for salt glazed stone ware gully trap, square or round mouthed, (150 x 150) mm size, shape as required, including taking out of old Gully Trap and jointed with old connections and pipes complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping/ bed block including weathering slightly rounded or chamfered angles and throating as directed and including necessary formwork complete all as specified and directed.
Material and labour for taking down window type Air Conditioner of upto 2 TR, cleaning by water , thoroughly, cleaning by caustic and re-washing with plain water, Servicing. greasing,replacing of spares required, and refixing at same location with proper rectification of leakage and commissioning , etc. complete all as specified and directed. Existing makes of AC:- LG / Samsung / Voltas / Videocon/As per existing. Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the quoted rate.
Dismantling covers of outdoor and indoor units of split type Air Conditioner of capacity upto 2.0TR, cleaning completely the condenser coil and cooling coil initially with hand blower, spraying with soap water solution and finally cleaning with clear water, servicing, greasing, replacing of spares required, refixing the covers with proper rectification, in same position complete all as specified and directed. Existing makes:- LG / Samsung / Voltas / Videocon/As per existing Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately, under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted.
Material and labour for taking down water cooler of upto 150 ltr, cleaning by water , thoroughly, cleaning by caustic and re-washing with plain water, servicing, greasing, replacing of spares required, and refixing at same location with proper rectification of leakage and commissioning etc. complete all as specified and directed. Existing makes of AC:- LG / Samsung / Voltas / Videocon/As per existing. Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately, under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted.
S&F in repair jointing capillary tubes filter strainer by brazing, cleaning / flushing whole the system, checking any leakage and making good including testing at 350 PSI complete for Window type AC of capacity upto 2.0 TR complete all as specified and directed.
All as per item No. 183 above but, Split type AC of capacity upto 2.0 TR complete all as specified and directed.
All as per item No. 183 above but, Water cooler of capacity upto 150 ltrs complete all as specified and directed.
Dismantling of blower fan motor cutting burnt coils and taking out from the stator, cleaning the stator using petrol, rewinding using super enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as specified and directed. Window type AC of capacity upto 2 TR. Notes:- (i) The unit rate quoted shall be deemed to include for rewinding also.
Dismantling of blower fan motor cutting burnt coils and taking out from the stator, cleaning the stator using petrol, rewinding using super enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as directed for Split type AC of capacity upto 2.0 TR complete all as specified and directed. Notes:- (i) The unit rate quoted shall be deemed to including for rewinding also.
Dismantling of blower fan motor cutting burnt coils and taking out from the stator, cleaning the stator using petrol, rewinding using super enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as directed for Water Coolers of capacity upto150 litres complete all as specified and directed. Notes:-(i) The unit rate quoted shall be deemed to including for rewinding.
Repair body and base of water cooler including providing plain MS Sheet of existing gauge / thickness and angle iron of existing thickness and size including necessary welding / brazing repair of leakage in water tank of water cooler, by arc welding after necessary leak testing,, including preparing the steel and iron surface and spray painting with synthetic enamel paint, glossy finish / shop finish, as directed by the Engineer- In- Charge,etc complete, of capacity upto150 litre complete all as specified and directed.
S&F Running capacitor 10-40 mfd for 1.5/1.0/2.0 TR capacity window type/split type Air Conditioner complete all as specified and directed.
All as per item No. 190 above but Running Capacitor 4 mfd complete all as specified and directed.
All as per item No. 190 above but Capillary Tube (copper) as per existing size complete all as specified and directed.
All as per item No. 190 above but Filter strainer complete all as specified and directed.
All as per item No. 190 above but Starting relay complete all as specified and directed.
All as per item No. 190 above but Air filter made of plastic frame and nylon net complete all as specified and directed.
All as per item No. 190 above but Thermostat switch make complete all as specified and directed.
All as per item No. 190 above but Contactor relay for split type AC complete all as specified and directed.
Supply and fix starting capacitor 45/ 50 Mfd upto 2 ton split type AC complete all as specified and directed. (Make : SARADA / UNIVERSAL / Usha / Copco / HPL / L&T / Existing make)
Supply and fix Blower motor for window type AC 1.5 Ton capacity complete all as specified and directed.(Make : as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
All as per item No. 200 above but Blower motor for window type AC 2 Ton capacity complete all as specified and directed. (Make : as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
All as per item No. 200 above but Blower motor for Split type AC upto 2 Ton capacity complete all as specified and directed. (Make : as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc).
Supply and fix in repair Front grill for Window type AC of capacity 1.5 TR complete all as specified and directed.(Make: as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair Front grill for Window type AC of capacity 2 TR complete all as specified and directed. (Make: as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair PCB Board for split type of capacity 1.5 TR AC complete all as specified and directed.(Make: as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair PCB Board for split type of capacity 2.0 TR AC complete all as specified and directed.(Make: as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply only Rubber bushing for blower motor of suitable and existing capacity AC complete all as specified and directed.
Supply and fix in repair swing motor for split type AC of capacity upto 2.0 TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair Swing motor for window type AC of capacity 2.0 TR complete all as specified and directed. Make:-(as per existing make).
Supply and fix in repair Display assembly for spilit type AC of capacity 2.0 TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair Display assembly for WINDOW type AC of capacity 2TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair Sensor for Indoor unit of Split type AC, of capacity Upto 2.0 TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair Service line charging valve 5/8'' (Brass)complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair Liquid line valve 1/4'' (Brass) complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair PCB Board for window type AC upto 2 .0 TR complete all as specified and directed. Make:- (as per existing make of Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair condenser coil of copper for split type AC, of capacity 1.5 TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair condenser coil of copper for split type AC, of capacity 2.0 TR complete all as specified and directed. Make:-(as per existing make)
Supply and fix in repair condenser fan for AC of 1.0 TR/1.5 TR / 2.0 TR complete all as specified and directed. Make:- (as per existing make)
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through PVC casing-caping surface type complete all as specified and directed. Note:- 3 runs of cable, 1 run of casing-caping shall be measured and paid as one unit i.e Rm.
Supply and fixing in repair rotary sealed unit Compressor for window/ split AC of 1.5 Ton capacity complete all as specified and directed.
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6 sqmm as earth continuity conductor drawn through PVC casing-caping surface type complete all as specified and directed. Note:- 3 runs of cable, 1 run of casing-caping shall be measured and paid as one unit i.e Rm. Make of cable:- MESCAB / POLYCAB / HAVELLS / KEI / FINOLEX. Make for casing Caping:- Plaza / Presto Plast / Precision/ M/S AGK Industries
Supply and fixing in repair rotary sealed unit Compressor for window/split AC of 2 Ton capacity complete all as specified and directed.
Supply and fixing in repair Water cooler compressor capacity above 40 ltrs and upto 150ltrs complete all as specified and directed.
Supply and laying in repair refrigerant line copper tubing of size 3/8 " with clamping on wall surface or concealed with both the ends connection complete all as specified and directed.
All as per item Ser No 224 above but of size 1/4 " complete all as specified and directed.
All as per item Ser No 224 above but of size 1/2 " complete all as specified and directed.
S & F in repair foam insulation/ keniform for copper tubing of size 1/2" and 1/4'' dia complete all as specified and directed.
S&F in repair flexible drain pipe for split type AC of existing size complete all as specified and directed.
Supply and fixing in repair, push type tap copper alloy chromium plated 15 mm bore suitable for upto150 ltrs capacity water cooler complete all as specified and directed.
All as per item No. 229 but Rubber lining for top cover gasket of capacity upto 150 litre Water Cooler complete all as specified and directed.
Supply only Starting relay suitable for 5/8 HP motor of water cooler complete all as specified and directed.
Supply only Starting capacitor 80/100 Mfd for water cooler complete all as specified and directed.
Supply only Thermostat complete all as specified and directed.
Supply and fix in repair Float valve Brass with fly nut, of dia / bore 15 mm , etc complete screwed as per existing complete all as specified and directed.
Supply only Over load protector complete all as specified and directed.
Supply only Capilary tube as per existing size (Copper) complete all as specified and directed.
Supply only Blower motor as per existing complete all as specified and directed.
Supply only CP Basin tray complete all as specified and directed.
Supply only Running capacitor 15 mfd complete all as specified and directed.
Supply and charging refrigeration gas R-22 for Split/window AC conforming with N2 pressure testing and flushing the system with liquid nitrozen, dehydration and evacuation of the system complete all as specified and directed. Make: Mafron or equivalent .
Dismantling, shifting and refixing of split type AC of capacity 1.5 to 2.0 TR including proper arrangement to keep outer unit (Angle iron with nut bolt) safely without gas leakage, in the unit complete all as specified and directed.
S & F in repair for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt complete all as specified and directed. Make: Havells/Legrand/L&T / Indoasian / HPL / Standard).
Material and labour for cutting holes in brick wall for fixing of window type Air Conditioner including removal of rubbish from the site of work within 50 m distance including necessary, second class hard wood, wooden frame work not less than 2" by 2" thick and size as per AC model including plastering 10 mm thick in CM 1:6, side walls in cement mortar 1:6 and white wash / distemper complete, to match the existing surface, including preparation of new wooden surfaces and applying 2 coats of synthetic enamel paint, first quality, over a coat of pink primer, etc complete all as specified and directed. Make of paint:- Asian / Berger / Jenson & Nicholson / Berger.
Taking down outdoor unit of 1.5TR/ 2.0 TR capacity removing unserviceable AC stand/ angle iron bracket fixing new AC stand/ angle iron bracket in repair (including two coats of sunthetic enamel paint over a red oxide primer) fixing to the wall by foundation bolts refixing the out door unit connection the suction and discharge line complete testing and running all as directed.
Dismantling and taking out voltage stabllizer transformer unit, auto transformer varier, electric circult board, all cable connections, including repairing/ replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, voltmeter, PVC connector, indicator lamp, cutout, MCB complete parts along with testing commissioning and transportation charges from site to workshop all as directed of capacity Upto 2 KVA complete all as specified and directed.
All as per item No. 245 but 3 KVA to 5 KVA capacity complete all as specified and directed.
Supply and fix modular plate with starter plug and socket AC single phase, 240 Volts, 25 Amps capacity, including metallic mounting box including taking down the old unserviceable modular plate with starter plug and socket complete all as specified and as directed. Make :Crabtree /Havells/C&S/Standard or equivalent)
S&F in repair 20 Amp plug top complete with all connection, complete all as specified and as directed. MAKE:- Anchor / Cona / Bajaj / Crabtree / Havells / HPL / C&S / Standard
M&L for painting with DUCO paint, first quality, (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed for Window type AC's upto 2.00TR- Make:- Asian / Berger / Jenson & Nicholson / Shalimar.
M&L for painting with DUCO paint, first quality, (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed by Engineer-in-Charge for Split type AC's upto 2.00TR capacity :- Make:- Asian / Berger / Jenson & Nicholson / Shalimar.
M&L for painting with DUCO paint, first quality, (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed by Engineer-in-Charge for water coolers upto 150 capacity Make:- Asian / Berger / Jenson & Nicholson / Shalimar.
Supply and fix automatic voltage stablizer single phase 240 volt 50 hz of capacity 5 KVA complete all as specified and directed.
Supply and charging refrigeration gas R-134 for refrigerator/ water cooler/ deep freezer conforming with N2 pressure testing and flushing the system with liquid nitrozen, dehydration and evacuation of the system complete all as specified and directed.
Excavating in trenches n.exc 1.5 m wide or n exc 10 sq m on plan and n exc 1.5 m in depth for foundation etc and getting out in soft / loose soil for taking out pipe line complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and directed.
Removing excavated materials not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cutting hard standing / road for laying of pipe, not exc 30 cms wide and not exc 30 cms deep, and getting out in soft/ loose soil, etc complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) not exc 30 cms wide and not exc 30 cms for filling and making good to disturbed surfaces of road /hard standing etc complete all as specified and as directed.
Taking out from trenches or taking down from wall GI steel tubing and connections, 20 mm bore, setting aside and cleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as specified and directed.
All as per item No 259 here in before but for 25 mm bore of pipe complete all as specified and directed.
All as per item No 259 here in before but for 40 mm bore of pipe complete all as specified and directed.
All as per item No 259 here in before but for 50 mm bore of pipe complete all as specified and directed.
Relaying of old serviceable GI pipe 20mm bore obtained from serial no 259 here in before with spigot and socket ends in new or old position in any length, laid in trenches after cleaning of inner surface and applying with two coats of black bituminous paint (sutiable for drinking water purpose) including testing complete all as specified and directed.
All as per item no 263 here in before but for 25 mm bore obtained from serial no 260 here in before complete all as specified and directed.
All as per item no 263 here in before but for 40 mm bore obtained from serial no 261 here in before complete all as specified and directed.
All as per item no 263 here in before but for 50 mm bore obtained from serial no 262 here in before complete all as specified and directed.
Supply and fixing of 20 mm bore GI tubing, medium grade with all new fittings as required complete fixed to walls and ceilings or laid in floors including testing complete all as specified and directed.
All as per item No 267 here in before but for 25 mm bore of pipe complete all as specified and directed.
All as per item No 267 here in before but for 40 mm bore of pipe complete all as specified and directed.
All as per item No 267 here in before but for 50 mm bore of pipe complete all as specified and directed.
M&L for Minor leakage rectification work of water supply line for GI pipe of size ranging from 15 to 25mm complete within 4-6 Hrs. of raised complaint complete all as specified and directed.
All as per item No.271 above but for 40/ 50mm bore GI pipe complete all as specified and directed.
Supply and fix 20mm bore gun-metal, gate valves, with iron wheel head, screwed both ends for iron pipe and fixed after taking down old unserviceable one complete all as specified and directed. Make : Audco/Laxmi/ Uphadhyay.
All as per item No. 273 above but 25 mm bore complete all as specified and directed.
All as per item No. 273 above but 40 mm bore complete all as specified and directed.
All as per item No. 273 above but 50 mm bore complete all as specified and directed.
Material and labour for taking out motor set of capacity 3/5 HP from position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections complete all as specified and directed.
Material and labour for repair and replacement of spare parts of 3/5 HP induction motor 3 phase 415 volt, transportation of same from site to workshop and back dismantling existing winding and rewinding of motor with insulated copper wire of existing gauge varnished, reassembling and refixing complete all as specified and directed.
Material and labour for taking up / lowering of submersible pump of 5/ 7.5 HP from bore well including dismantling the pump from delivery line and refixing the same pump after repairing complete all as specified and directed. Note; Tools, Plants, Lifty arrangements and transportation are deemed to be included in the quoted unit rate.
Material and labour for taking out sewage pump set of capacity 3/5 HP , transportation of same from site to workshop & back , dismantling of cable/ pipe connnection and reinstallation of pump set after repair on the existing foundation and making electric connection complete all as specified and directed.
Material and labour for repair and replacement of spare parts of sewage pump capacity 3/5 HP for bushings of pump set including turning , grinding etc complete all as specified and directed. Note: Taking out and refixing the sewage pump set will be measured separately under Item No. 27 here-in-before.
M&L for cleaning of existing underground water reservior of storage capacity approx 25000 ltrs complete inside wall , base and ceiling including brooming and brushing with steel wire brush and brushing with bleaching powder, scrapping down mud, moulds, moss, peat or any other foreign materials, removing the rubbish to a distance not exceeding 50 m complete and cleaning with fresh water comlete all as specified and as directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully and keeping aside serviceable materials for reuse including making good of the disturbed surfaces complete all as specified and directed.
Material and labour for point wiring (surface type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC casing-N- caping (medium duty) double lock type,size of casing caping as required at site but not less than 20mm with fittings and accessories pressed steel sunken terminal box in concealed made out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick bakelite sheet cover for fixing switches, sockets, regulator etc and earth continuty conductor shall be connected to common earth and earth dolly for one light point controled by one, one way 5 Amp switch complete all as specified and directed.
All as per Item No. 284 above but for one fan point controlled by one, one way 5 Amp switch complete all as specified and directed.
All as per Item No. 284 above but for one 5 pin socket outlet 05 Amp on independent board complete all as specified and directed.
All as per Item No. 284 above but for one 5 pin socket outlet 05 Amp on same board complete all as specified and directed.
All as per Item No. 284 above but for one bell/buzzer point controlled by one push button complete all as specified and directed.
All as per Item No. 284 above but for one light point controlled by two 2 way switch complete all as specified and as directed.
All as per Item No. 284 above but for one 15 Amps socket outlet but using 2.5 sq mm, copper conductor with 2.5 sq mm, PVC insulated single core cable for earth continuity conductor complete all as specified and directed.
M & L for concealed point wiring complete with 1.5 sq mm FRLS, PVC insulated multi standard copper conductor single core cable 1100 volts grade,drawn into non metalic PVC rigid conduit medium grade of size not less than 20mm bore and conduit accessories fixed on wall roof etc, and including provn of PVC insulated 1.5 sq mm copper conductor cable for each continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6 mm thick MS sheet concealed in wall and laminated sheet cover of 3 mm thick on top for housing the switches socket,outlet etc., for one light point controled by one, one way 5 Amp switch complete all as specified and directed. Note :- PVC conduit , making good disturbed wall surfaces including finishing with cement mortor 1:4 matching with existing shade of the painted surface are deemed to be included in the quoted rate.
All as per Item No. 291 above but for one fan point controlled by one, one way 5 Amp switch complete all as specified and directed.
All as per Item No. 291 above but for one 5 pin socket outlet 05 Amp on independent board complete all as specified and directed.
All as per Item No. 291 above but for one 5 pin socket outlet 05 Amp on same board complete all as specified and directed.
All as per Item No. 291 above but for one bell/buzzer point controlled by one push button complete all as specified and directed.
All as per Item No. 291 above but for one light point controlled by two 2 way switch complete all as specified and as directed.
All as per Item No. 291 above but for one 15 Amps socket outlet but using 2.5 sq mm, copper conductor with 2.5 sq mm,PVC insulated single core cable for earth continuity conductor complete all as specified and directed.
M&L for cutting chases, pinning in making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landing, steps, cills, sunshades sheleves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good to disturbed surfaces, cutting not exc 10 cm grith complete all as specified and directed.
Supply and fix switch piano flush button 6 Amp single pole, one way complete all as specified and as directed.
Supply and fix socket outlet 5 Pin, 6 Amps flush type complete all as specified and as directed.
Supply and fix Switch socket combination 5 Pin, 6 Amp flush type complete all as specified and as directed.
Supply and fix switch socket combination 5 Pin 15/16 Amp flush type with complete all as specified and as directed.
Supply and fix switch flush type, 6 Amps, single pole, two way complete all as specified as directed.
Supply and fix lamp holder insulated body with back plate for angle/batten fittings complete all as specified and as directed.
Supply and fix ceiling rose surface bakelite, 65 x 50mm, three terminals complete all as specified and directed.
Supply and fix bell push, flush type 6 Amps complete all as specified and as directed.
Supply and fix electronic fan regulator stepped type flush type AC 240 volt complete all as specified and as directed.
Supply and fix in replacement call bell Ding Dong, AC, 240V single pole complete all as specified and directed.
Supply and fix lamp holder PVC polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed.
Supply & fix Modular switch, one way, 6 Amp, 1 module complete all as specified and directed.
Supply & fix Modular switch, one way, 16 Amp, 1 module complete all as specified and directed.
Supply & fix Modular switch 2 way, 6A, 1 Module complete all as specified and directed.
Supply & fix Modular Bell push 6A,1 Module complete all as specified and directed.
Supply & fix Modular socket, 6A-2/3 pin combined 2 Module complete all as specified and directed.
Supply & fix Modular socket, 15A/16A-2/3 pin combined 2 Module complete all as specified and directed.
Supply & fix Modular fan step regulator, 120 watt, 2 module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 1 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 2 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 3 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 4 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 6 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 8 Module complete all as specified and directed.
Material and labour for sub-main wiring (Concealed type) with two run of PVC insulated, unsheathed, FRLS single core, multistranded copper conductors of size 4.0 Sq mm and one run of 4.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site and taking down old sub main wiring with conduit complete all as specified and as directed. Note:- (i):Two run of 4.0sqmm and one run of 4.0 sqmm copper conductor ( for Phase,Neutral and Earth)+One run PVC conduit shall measured as one unit).
Material and labour for sub-main wiring (Concealed type) with two run of PVC insulated, unsheathed, FRLS single core, multistranded copper conductors of size 6.0 Sq mm and one run of 6.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site and taking down old sub main wiring with conduit complete all as specified and as directed. Note:- (i):Two run of 6.0sqmm and one run of 6.0 sqmm copper conductor ( for Phase,Neutral and Earth)+One run PVC conduit shall measured as one unit).
Supply and fix in replacement powder coated sheet metal enclosure (in concealed) single pole & neutral for DBs (Double door) 4 way, 240 V with 200 amps rated busbar DIN channel, neutral link & earth link superline complete all as specified and directed. (Chase cutting & make good to disturbed surfaces shall be deemed to be included in quoted rate)
All as per item No 325 here in above but for 8 way SPN DB complete all as specified and directed.
All as per item No 325 here in above but for 12 way SPN DB complete all as specified and directed.
Supply and fix in repair vertical TPN DB with MCCB incomer of 4 way in double door suitable for four pole MCCB (63A/100 A)as incomer including MCCB+12 modules incoming and outgoing make good of damaged surface/wall including re-connection with existing earth wire to DB complete all as specified and directed. Note:- MCCB shall be measured and paid seperately.
Supply and fix in repair MCCB triple pole & neutral 40-100 amps,,16 KA, with all incoming / outgoing connections suitable for fix 4 way vertical type TPN DB in double door twith proper size of aluminium lugs complete all as specified and directed.
Supply and fix in repair MCB single pole & neutral / Double Pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified and directed.
Supply and fix in repair MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified and directed.
Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) with Funnel for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 150mm C/C both way and two Nos lifting handle made of 8mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete and as specified in electrical plate No. 3 of SSR Pt I including taking down old earthing complete all as specified and directed
Supply and fix in repair GI wire 4.0 mm as earth continuity complete all as specified and directed.
Supply and fix in repair GI pipe 15 mm bore (dia), light-grade for protection of earth electrode complete all as specified and directed. Make:- Prakash / Utkarsh Tubes Ltd / Jindal / Zenith / Bansal / Nezone / M/S BST Infratech Ltd.
Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) with Funnel for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 150mm C/C both way and two Nos lifting handle made of 8mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete and as specified in electrical plate No 3 of SSR Pt I including taking down old earthing complete all as specified and directed.
Supply & fix LED tube light fitting, 1 x 18 watt bipin holders, connector block etc. complete and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible twisted twin core cable ,and fixing the light fitting to walls / roof complete all as specified and directed.
Supply and fix LED light fitting mirror type high output diffuser 2 ft ,10 watt, 240 volt AC decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of sutiable size all as specified and as directed.
Supply and fix round shape 6 watt, 240 volt , AC recessed type with high efficiency PMMA diffuser soft glare free light complete with diffuser, holder, led lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fix round shape 12 watt, 220 volt , AC recessed type with high efficiency PMMA diffuser soft glare free light complete with diffuser, holder, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm 40 watt, 240 V AC recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fix In replacement LED light fitting, 1x10/1x9 W bulk head luminaries, with LED lamp, etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fix in replacement LED lamp (B22 Base type) of 1x7 W complete all as specified and as directed.
Supply and fix in replacement LED light fitting 25/35 watt energy saving versatile pressure die-cast aluminium building security luminaire with suitable GI bracket complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 240V, 50 HZ complete all as specified and as directed.
Supply and fix LED flood light 70 watt 240 V AC outdoor/indoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
All as per item no 344 here above but for 60 Watt complete all as specified and as directed.
Taking down carefully Ceiling Fans of any make, model and capacity from their existing places for replacement of bush, bearing, Capacitor, servicing i. e. lubricating / Greasing and for rewinding/ painting by dismantling the same and keep the blades, canopy, splitpin and other parts and components in safe custody and hanging / fitting on its previous position after repair/ rewinding/ painting/ replacement of spares etc complete all as directed. Note:- i) The unit rate quoted is deemed to include for the labour element involved in replacing the spares as mentioned herein below. (ii) The spares replaced shall be measured and paid as supply only items herein below. (iii) The spares shall suit the exisiting makes of fans or as per existing make of spares, as approved by the GE. (iv) Rewinding and painting shall be measured and paid separately. Existing makes :- Bajaj, Khaitan, Usha, Himadri
All as per item No. 346 above but Exhaust Fans complete all as specified and directed.
All as per item No. 346 above but Air Circulators wall mounted fan complete all as specified and directed.
All as per item No. 346 above but floor mounted pedestal fan complete all as specified and directed.
Supply only GM Bush for ceiling fan 1200/1400 mm sweep/ Exhaust Fan 230/300/350/450 mm sweep/or any type fan complete all as specified and directed.
Supply only Ball bearing (cat No. 6201) for ceiling Fan/Exhaust Fan / or any type fan complete all as specified and directed.
All as per item No. 351 here-in-before but cat No. 6202 complete all as specified and directed.
All as per item No. 351 here-in-before but cat No. 6203 complete all as specified and directed.
Supply only capacitor 2.5 mfd, 220 volts complete all as specified and directed. Make:Tipcon / Universal / Sarda / Usha. / C&S).
All as per item No. 354 here-in-before but 3.0/4.0 mfd complete all as specified and directed.
Supply and fix in replacement of louver shutter for 300 mm sweep exhaust fan, of existing make, made of MS sheet folded type complete all as specified and directed.
All as per item No 356 here-in-before but for 450 mm sweep exhaust fan complete all as specified and directed.
Material and labour for painting by spraying with synthetic enamel paint to Ceiling Fans / Exhaust Fans/ Air Circulators wall mounted Fans/Floor mounted pedestal Fans including Blades/Down rods/ Canopy/Stand, Casing/ Cage and all accessories after preparation of surface including thoroughly rubbing /cleaning old rusted spot complete all as specified and directed. Make of paint:- Asian / Berger / Jenson & Nicholson / Shalimar.
Material and labour for Rewinding of ceiling fans armature of 1200 mm /1400 mm sweep of any make & Model with replacing the burnt out winding by new super enameled high grade copper wire of existing gauge and number of turns and all insulating materials including heat vernishing and testing complete all as specified and directed.
All as per item No. 359 here-in-before but for exhaust fan 230mm/ 300mm sweep, single phase, 230 volts complete all as specified and directed.
All as per item No. 359 here-in-before but for exhaust fan 450 mm sweep, three phase, 230 volts complete all as specified and directed.
Supply and fix in replacement fan blades for exhaust fan of 300 mm sweep as per existing make and type complete all as specified and directed.
All as per item No. 362 here-in-before but for exhaust fan of 450 mm sweep complete all as specified and directed.
Material and labour for lathe work for worn out spindle of ceilling fan /Exhaust Fan/Air Circulators/Wall mounting Fan of any sweep , make & Model with replacing the worn out spindle by new one of existing size and materials including testing for free motion of fans complete all as specified and directed.
Material and labour in replacement of incoming twin core copper flexible wire ( not more than 45cm) of size 14/0.0076 from ceiling rose to ceiling fan / exhaust fans complete all as specified and directed.
Supply and fix in replacement 3 pin plug top 6 Amps for air circulator wall mounted fan/ floor mounted pedestal fans complete all as specified and directed.
Supply and fix in replacement 5 pin plug top 16 Amps for air circulator wall mounted fan/ floor mounted pedestal fans complete all as specified and directed.
Supply and fix in repair 2.5 Mfd fan capacitor, 220V complete all as specified and directed.
Taking down carefully storage type water heater (Geyser ) of any make of capacity 25/35/50 Ltrs after removing all electrical and water connection from installed position at different locations,dismantling the geyser into parts for inspection, checking/ testing of all parts/ accessories like appratus plate, heating element, thermostat switch, neon lamp, water tank, safety valve, spacer ring, rubber gasket, nut-bolts, inspection plate, bottom & top cover etc and complete de-scaling of water tank and brazing the same to make it leak proof complete inclduing replacement of unserviceable spare parts and re-installation, making electric and water connections and testing complete all as specified and directed. Note : - (a) Old unserviceable parts required for replacement shall be measured & paid separately. (b) Painting if required shall be measured and paid separately all as specified and directed.
Supply and fixing Apparatus assembly plate (8/9 hole) for Geyser of 25 /35 /50 Ltrs capacity, as per existing type and model complete all as specified and directed.
Supply and fixing thermostat straight stem type as per existing model complete all as specified and directed.
Supply and fixing heating element 1500 watt suitable for Geyser of 25 Litres capacity as per existing type and model complete all as specified and directed.
Supply and fixing heating element 2000 watt Geyser of 25/35/50 Ltrs capacity as per existing type and model complete all as specified and directed.
Supply and fixing Indicating lamp LED type, as per existing model (Red/ Green) (square/ round) batten type for Geyser of 25/50 Litres capacity complete all as specified and directed.
Supply and fixing 15 mm dia 450 mm long PVC flexible cold water inlet pipe nut type complete all as directed. Make: Prayag /Suprimo or equivalent as approved GE.
Supply and fixing 15 mm dia 450 mm long hot water pipe (inlet wire mess and nut type) water inlet pipe complete all as specified and directed.
Supply & fixing 15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated after taking down old one complete all as specified & directed.
Supply & connecting PVC insulated and overall PVC sheathed and flexible multistranded copper conductor cable 3 core of size 2.5 sqmm for 25/35/50 Ltrs capacity Geyser after taking down old one complete all as specified and directed.
Supplying, laying, commissioning and testing XLPE insulated PVC sheathed armoured heavy duty electric cable of size 10 Sqmm 4 core with aluminium conductor for working voltage upto and including 1100 volts, ISI marked to be laid on wall/ground, fixed to pole, wall/roof complete with cable end, lugs including required size of aluminium thimble for making connection including taking down old unserviceable cable of any type and size completed all as specified and directed.
Supplying, laying, commissioning and testing XLPE insulated PVC sheathed armoured heavy duty electric cable of size 6 Sqmm 2 core with aluminium conductor for working voltage upto and including 1100 volts, ISI marked to be laid on wall/ground, fixed to pole, wall/roof complete with cable end, lugs including required size of aluminium thimble for making connection including taking down old unserviceable cable of any type and size completed all as specified and directed.
Supply and fixing LED street light fitting 35 watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed.
Material and labour for street light fitting bracket, made out of 40 mm bore GI pipe, light grade of length not less than 1.20 mtr, 45 degree bend to shape and fixed on pole with 2nos FI clamps of 40x5mm of suitable length made shape of pole , bolts, nuts & washers including taking out old unsv bracket complete all as specified & directed.
Material and labour for sand cushioning with clean dry sand laid in trenches for cable protection complete all as specified and directed. Note: Punned down thickness shall be measured and paid.
Supply and lay sub class 'B' bricks, laid dry in trenches for cable protection laid with its longitudinal axis perpendicular to the cable axis complete all as specified and directed
RUNJEN CONSTRUCTION
RBS Builders
ChakrabortyTraders
DK DAS AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .