| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹8.5 L+₹28,939 (3.51%)Rejected-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L2 | Rejected-AOC being L2 | |
| 3 | L3₹8.5 L+₹29,687.45 (3.60%)Rejected-AOC JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | L3 | Rejected-AOC being L3 | |
| 4 | L4₹8.7 L+₹49,010 (5.95%)Rejected-AOC | L4 | Rejected-AOC being L4 | |
| 5 | L5₹10.0 L+₹1.8 L (22.0%)Rejected-AOC BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L5 | Rejected-AOC being L5 |
Tender Value
₹9.7 L
EMD Value
₹19,400
Closing Date
6 Feb 2023, 6:00 pmClosed
AGE I Cannanore
AGE I Cannanore HQ Hospital Kannur PO 670017
Special repair to bldg No WL-31/4 to 7, 9 and WL-31/10 (OR md accn) at DSC Centre under AGE (I) Cannanore.
2023_MES_574186_1
8247
Open Tender
Civil Works
Item Rate
150 days
Cannanore
Category E a (i)
8 documents required · 8 mandatory
₹500
Yes
AGE I Cannanore
₹19,400
Yes
3 Mar 2023
10 Jan 2023
10 Feb 2023
11 Jan 2023
6 Feb 2023
24 Jan 2023
11 Jan 2023 - 17 Jan 2023
Amount
Demolition of cement concrete (reinforced) other than ground floors not exceeding 15cm thickness and removing debris outside MD land all as directed.
M&L Reinforced cement concrete (1:1.5:3), type A1, (using 20mm graded stone aggregate) as in roof slabs supported on walls, beam etc all as specified and directed. Note : Reinforcement and form work shall be measured and paid separately.
S&F TMT bars 10 mm dia and over as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removing debris outside MD land all as directed.
Taking down cement or cement lime plaster on brick/stone walls or in ceiling surfaces incl racking out joints hacking for key scrubbing down with water etc and removing rubbish outside MD land all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on stone masonry surfaces, finished even and smooth without using extra cement all as specified and directed .
M&L 25mm thick PCC 1:2:4, Type B0 (using 12.5mm graded stone aggregate) as in flooring and finished fair and even all as specified and directed.
M&L for coloured non-skid ceramic tiles, 7mm to 8mm thick, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured / white cement to match laid over and including 20mm thick screed bed or bedding layer in cement mortar (1:6) all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles and rubbish off the premises all as directed.
M&L for white glazed ceramic tiles 300x200x7mm thick, as in skirting / dado, set and jointed in neat cement slurry and pointed in coloured / white cement to match laid over and including 10 mm thick backing on stone/brick masonry surfaces in cement mortar (1:4) all as specified and directed.
S&F Stainless steel sinks 1mm thick with plugs, washers and waste; including bedding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe, overall size 495mm x 420mm, bowl size 410 x 330 x 160mm etc complete all as specified and directed.
Taking down chowkats with shutters any description n exc. 1.5 Sqm each (without taking off shutters from the frame) all as directed.
Taking down chowkats with shutters any description exc. 1.5 Sqm but n.exc 4 Sqm each (without taking off shutters from the frame) all as directed.
Taking down wooden door shutters of any description n exc 1 Sqm each all as directed.
Taking down wooden door shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each all as directed.
Taking down door shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each and refixing the other opening after easing and adjusting and refixing/renewal of builders hardware with screws all as directed.
M&L for mild steel flat iron of size 25 x 3mm for holdfasts for securing new wooden frames and similar articles conforming to Fe-290 Gde-E-165 all as specified and directed.
M&L for PCC 1:2:4, type B1 using 20mm graded stone aggregate for fixing hold fast including necessary form works all as specified and directed.
M&L for second class hardwood, plain, solid straight chowkats & frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified and directed.
S&F 35mm thick second class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc; (with out sash bars), edges of framing, fitted with cut and mitered beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section 8, Clause 8.24 (a) all as specified and directed.
M&L for second class hardwood, panelled shutter 35mm thick (any number of panel) with lock rail and panel of 9mm BWP, 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and directed.
Material & Labour for 2nd class hardwood glazed and skeleton shutters, 30 mm thick open rebated and prepared to receive glass, gauze, etc., but divided into squares, with plain, chamfered or rounded,mitred and rebated sash bars,any numbers fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); and fitted to chowkats complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings, etc, with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290 Gde E-165 all as specified and directed.
S&F 3mm thick plane sheet glass, ordinary quality and glazing with oil putty in squares not exc 0.50 Sqm in each pane with putty or fixed with beads all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
S&F 200mm long aluminum anodized barrel tower bolts of extruded section fixed with stainless steel screws all as specified.
S&F aluminium anodised sliding door bolts 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed
S&F stainless steel butt hinges medium weight; 100mm size as per IS 21817 fixed with stainless steel screws all as specified.
S&F stainless steel butt hinges medium weight; 75mm size as per IS 21817 fixed with stainless steel screws all as specified.
S&F extruded aluminum alloy anodized handle fabricated type 150mm size fixed with stainless steel screws all as specified.
S&F extruded aluminum alloy anodized handle fabricated type 100mm size fixed with stainless steel screws all as specified.
M&L preparing old treated wooden surfaces of any description over 10 cm width or girth and applying a coat of synthetic enamel painting all as specified and directed.
M&L preparing new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer all as specified and directed.
M&L for preparation of new untreated steel surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M & L for preparation of newly plastered surfaces of wall and applying one coat of wall primer and two coats of oil emulsion distemper and all as specified and as directed.
M&L for complete removal of existing treatment on surfaces of wall by scrapping down and applying two coats of oil emulsion distemper over a coat of wall primer (water or solvent thinnable) and all as specified and as directed.
M&L for GI 600 x 600 mm snap grid frame, powder coated sections comprising of undermentioned sections etc for grid frame including 4 mm thick non asbestos plain ceiling board of M/s Everest or equivalent ceiling grid system as per regular T-2430 or equivalant in Ramco/Charminar/Amstrong placed on GI grid including applying two coats of oil bound distemper over a coat of primer all as specified and directed :- (a) Suspended GI main runner 38 x 24 mm bulb Tee sections fixed with 4 mm dia GI bar @ 1200 mm c/c, level shall be adjusted with fly/bionet screws. (b) Placed in position cross Tee 1200 mm long and 28.8 x 24 mm bulb Tee section @ 605 mm c/c using snap grid and bionet fixing arrangement to secure main runners. (c) Ceiling GI 28.8 x 24 mm fixed with PVC Rawl plugs and GI screws tie secure with walls and all as per manufacturers instructions complete all as specified and directed.
Dismantling wall and ceiling boards or insulation boards/slabs/blankets any thickness, including cover fillets all as specified and directed.
Supply and fix mild steel chromium plated curtain rod 20mm dia fixed to wall including suitable bracket complete all as specified and directed.
JEETH CONSTRUCTION
T.P.SUNIL KUMAR
Sujith T
RS ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .