Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-Finance 354 SIRAJ MONDAL ROAD KANCHRAPARA 24 PGS N | KANCHRAPARA | NORTH 24 PARGANAS | WEST BENGAL | L1 | Accepted-Finance Being L1 Bidder. | |
| 2 | L2₹14.1 L+₹35,092.62 (2.55%)Rejected-Finance | L2 | Rejected-Finance Being L2 Bidder. | |
| 3 | L3₹14.2 L+₹39,903.62 (2.89%)Rejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L3 | Rejected-Finance Being L3 Bidder. | |
| 4 | L4₹16.9 L+₹3.1 L (22.4%)Rejected-Finance 90 1 287 1 ADARSHA PARA PURBA BIDHYHARPUR SHYAMNAGAR 24 PGS N PIN 743127 | SHYAMNAGAR | NORTH 24 PARGANAS | WEST BENGAL | 743127 | L4 | Rejected-Finance Being L4 Bidder. | |
| 5 | L5₹17.4 L+₹3.6 L (26.1%)Rejected-Finance VILL ADHARMANIK P O BASUDEVKHALI P S BERHAMPORE DIST MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L5 | Rejected-Finance Being L5 Bidder. |
Tender Value
Refer Docs
EMD Value
₹35,469
Closing Date
2 Sept 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, North 24 Parganas Electrical Div.P.W.Dte.
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059
Additional Electrical Work for Development of drainage system for storm water discharge at UTSHADHARA Project, Gandhi Ghat , Barrackpore.
2025_WBPWD_890832_1
WBPWD/EE/N24/EL/e-NIQ-46/25-26
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
Gandhi Ghat, Barrackpore
Please refer Tender documents.
4 documents required · 4 mandatory
₹35,469
North 24 Parganas Electrical Division, P.W.Dte.
13 Oct 2025
13 Aug 2025
4 Sept 2025
13 Aug 2025
2 Sept 2025
19 Aug 2025
18 Aug 2025
Amount
Supplying and fixing 415V, 315A TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T/Siemens/ABB) (for changing of main Incomer from 250A to 315A)
Supplying and fixing 160A, 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T/Siemens/ABB) (for Pump control Panel End)
Supplying and fixing 320A, 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. (L&T/Siemens/ABB).
Supply & installation of feeder pillar box made from 3mm thick M.S sheet reinforced with 50X50X5mm angle iron frame work with both side indivisual hinged door with 2 nos Godrej make 7 lever padlock arrangement as per direction of EIC. a) 250A Open-execution TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T). b)4nos. 315A(4 x 40x5mm), 500V 4 Bar Cu Busbar(1.5mtr.) as per G.S. c) Outgoing: 160A Open-execution TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T). -2 Nos (each Motor control panel) d)Interconnection: All connection should done with Cu bar,standard rating Cu. Wire and neutral link & provision for earthing attachment as per GS. e) Instrument: S/F 30-600 V, 96x96 mm digital Voltmeter (AE make)- 1 set, S/F 0 – 500 Amp, 96x96mm digital AMP meter (AE make) 1 set, S/F 200/5A, ring type CT -3 sets, S/F pilot Lamp set (LED indicator type) consisting with 3 colour R.Y.B. with sliding fuse.-3 nos. f) Danger Plate - 2 Nos. g) Provision for earthing attachment - 2 nos. The pillar box has to be installed with brick foundation of size 1200x1250x600mm(HXLXB) with hard jhama cement mortar soaling at bottom,300mm below & 450mm above GL neatly plastered & cemented as directed by EIC. Including Painting with 1 coat RO Primer and Two coat aluminium paint.
Supply & installation of feeder pillar box made from 3mm thick M.S sheet reinforced with 50X50X5mm angle iron frame work with both side indivisual hinged door with 2 nos Godrej make 7 lever padlock arrangement as per direction of EIC. a) Incoming i) 315/320A Open-execution TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T). ii) 320A Open-execution on load front operated Changeover switch. (L&T) b)4nos. 415A(4 x 50x5mm), 500V 4 Bar Cu Busbar(1.5mtr.) as per G.S. c)Outgoing: i) 250A Open-execution TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T) ii) 160A Open-execution TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T) iii) 63A Open-execution TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T) d)Interconnection: All connection should done with cu bar,standard rating Cu. Wire and neutral link & provision for earthing attachment as per GS. e) Instrument: S/F 30-600 V, 96x96 mm digital Voltmeter (AE make)- 1 set, S/F 0 – 500 Amp, 96x96mm digital AMP meter (AE make) 1 set, S/F 200/5A, ring type CT -3 sets, S/F pilot Lamp set (LED indicator type) consisting with 3 colour R.Y.B. with sliding fuse.-3 nos. f) Danger Plate - 2 Nos. g) Provision for earthing attachment - 2 nos. The pillar box has to be installed with brick foundation of size 1200x1250x600mm(HXLXB) with hard jhama cement mortar soaling at bottom,300mm below & 450mm above GL neatly plastered & cemented as directed by EIC. Including Painting with 1 coat RO Primer and Two coat aluminium paint.
Supply & Delivery of 4 core 95sqmm 1.1kV grade XLPE A/Al armoured cable (From Cut Out to Main Panel) (Make- Polycab/Gloster/RR)
Laying of one No. 4C x95 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
S&F and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry. 4Cx95
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4Cx95
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: a) By ISI-Medium GI pipe.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages a) 8 SWG
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 32/25 mm dia, 3 mm thick Polythene pipe, without earth continuity wire, by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles, as per GS.
S&F sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works, incl. S&F bakelite / perspex top cover by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required, as per GS. (a) 100 mm x 100 mm x 65 mm
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required as per GS. a) 2x6sqmm + 1x4sqmm [HTPNDB to Indutrial Plug-3kW),1Ph] [Make-Finolex/RR/Polycab]
Do - Do - Do - 2x2.5sqmm + 1x1.5sqmm [for Power plug,]
Do - Do - Do - 2x4sqmm + 1x2.5sqmm [for AC]
Finising the end of above PVC insulated & unsheathed copper wire as per GS. 2x6sqmm + 1x4sqmm
Do - Do - Do - 2x2.5sqmm + 1x1.5sqmm
Do - Do - Do - 2x4sqmm + 1x2.5sqmm
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. (Legrand Myrius/Honeywell MK)
S&F 240 V, 16 A, 3 pin Modular type plug socket (Legrand Myrius/ Honeywell MK Wraparound/ Anchor Roma Urban) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc., as per GS. (Legrand Myrius/Honeywell MK)
Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity-6.5 kW (Minimum) Minimum ISEER 3.8, BEE level 3-Star(min)[1st July22 to 31st December 2025] IS Compliance-IS-1391(Part-1 & Part-11) with all amendment Refrigerant R410A/R32 Compressor-Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 48°C and above Air Flow: 800 CFM (Minimum) Power supply -230V, 50Hz (±tolerance asper applicable standard), as directed by EIC. The scope of work is also includes supply and fixing of the following: (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape-3 mtr (ii) Necessary 3/4 core copper cable (FRLS type make: Finolex/RR Kable/Polycab) 3mtr and 230V. 25A, 3pin plug top with indicator (North West). [O. General / Mitsubishi Electric /Daikin/Blue Star/Voltas/ Carrier].
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per Direction of EIC including Supply of required Refrigerant, S&F of necessary suitable fixing arrangement for indoor and outdoor unit as recomended by Manufacturer, laying and making connection of refrigeration pipe, power cable, drain pipe ete and mendingn good the damages as per direction of the EIC.
S & F of additional following items for length exceeding 3 mtr. For complete installation and commissioning of above AC machine. (i) Supply & Fixing of extra refrigerant pipe (as requisite dia) with nitrite rubber insulation and wrapping tape (each mtr Refrigerent pipe will include cost of 1 meter liquid pipe line and 1 mtr gas pipe line of required dia and other accessories as required).
S & F of additional following items for length exceeding 3 mtr. For complete installation and commissioning of above AC machine. (i) 2.5 sqmm, 3/4 core copper cable (FRLS type - Make: Polycab/Finolex/RR Kabel).
Supply and Laying Soft Drawn PVC Drain Pipe 19 mm dia with proper supports & brackets as per direction of EIC. (Make- Suprime/Oriplast)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand Myrius/ Honeywell MK Wraparound/ Anchor Roma Urban), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (North West) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & fixing of 240 V time sensor switch consisting of the following accessories: A) 240 V, 40 A, DP MCB isolator of breaking capacity 10 KA & C characteristics - 01 no. (Make: L & T), B) 24 hour digital timer switch (Make: L & T) - 01 no., C) 240 V 25A DP power contactor (Make: L & T) - 01 no., D) Auto manual toggle switch - 01 no., E) 240 V, 20 A, SP MCB of breaking capacity 10 KA & C characteristics (Make: L & T) - 01 no., F) LED indicator lamp - 01 no. red & 01 no. green in 2+10 way SPN MCB DB (Make: L & T) incl. lock & key arrangement concealed in wall after cutting the wall & mending good the damages to original finish incl. interconnection with suitable size of Cu wire & provision for earthing attachment.
DEBNATH ENGINEERING WORKS (BID ID -6855476)
M/S R. K. ENTERPRISE (BID ID -6854945)
MANTHU ELECTRICALS (BID ID -6894996)
SRIDAM MONDAL (BID ID -6893397)
KRISHNA MULTISTRUCTURE ENGINEERING PVT LTD (BID ID -6864224)
Bharat Construction (BID ID -6877271)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .