| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC | ₹5.4 L Quoted ₹5.8 L | L1 | Accepted-AOC DUE TO L1 |
| 2 | surinder kumar jindal bros L2₹9.4 L+₹3.6 L (62.0%)Rejected-AOC | ₹9.4 L+₹3.6 L (62.0%) | L2 | Rejected-AOC DUE TO L2 |
Tender Value
₹9.9 L
EMD Value
₹20,000
Closing Date
18 Jan 2020, 6:00 pmClosed
CWE YOL CANTT
HQ CWE YOL CANTT
REPAIR/ REPLACEMENT OF EXISTING UNSERVICABLE SECURITY/ STREET LIGHTS, POST TOP LANTERN, LT UNDER GROUND CABLES OH LINES, LT PANELS AND OTHER ALLIED WORKS AT MIL STN DHARAMSALA
2019_MES_243249_1
CWE/Y-80/2018-19
Open Tender
Civil Works
Works
180 days
DHARAMSALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) DHARAMSALA
₹20,000
Yes
2 Mar 2020
26 Dec 2019
20 Jan 2020
26 Dec 2019
18 Jan 2020
7 Jan 2020
Amount
Dismantling LT poles (wood, steel or R.C.C.) any section, embeded in plain cement concrete including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling ACSR or AAC conductor complete of any type and size, complete all as specified.
Excavation in trenches n exc 1.5 metre wide & n exc 1.5 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes, for laying of cables etc n. exc 10 Sqm on plan n exc 1.5 metre in depth and getting out in any type of soil, complete all as specified.
Excavation in trenches for foundations of poles/ laying/ taking out of cables, pipes not exceeding 1.5 metres wide and exceeding 1.5 metres but not exc. 3 metres in depth and getting out in any type of soil, complete all as specified.
Returning filling in including spreading leveling, watering and well ramming in layers n. exc 25cm, all as specified.
Removal of excavated material to be distance n.exc 50 metres and depositing where directed at a level n.exc 1.5 metres high from the starting point, all as specified.
Plain cement concrete M-10 (Nominal mix) type C-2 (using 40mm graded brick aggregate) as in foundations/ sub base or in mass filling, holding of rising mains of GI pipe lines, foundations of stay etc all as specified and directed.
Plain cement concrete M-7.5 (Nominal mix) type D-2 (using 40mm graded brick aggregate) as in foundations/ sub base or in mass filling, holding of rising mains of GI pipe lines, foundations of poles, stay etc all as specified and directed.
Plain cement concrete M-15, nominal mix, B-0 using 12.5 mm graded mechanically crushed stone aggregate as, in lintels upto 1.50 metres clear span, steps, seismic and other similar bends, coping, bands plates for serving hold fasts, filling in mild steel frames etc. and the like including weathering slighting rounded or chamfered angles and throating complete all as specified and directed. Note:- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately.
Shackle type insulator porcelain vitreous white, brown or green 75mm high and 90mm dia for conductor of working pressure 1100 volts including galvanised mild steel straps of 31x3mm size, 12mm dia insulator bolts, washers and nuts , complete all as specified including taking down old insulators of any type, shape and size, all as specified and directed.
Galvanized steel wire 4mm dia for earth wire on LT poles stretched without kinks, bends and binding with wire, fabrication of cradles, spacers, road crossing, for guarding of wires etc. including taking down old wire of any type, shape and size, complete all as specified.
Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer including preparation of surfaces and dismantling old structural steel work in cross arms and stacking at site, complete all as specified & directed.
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
Sand cushioning to Underground Cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cablesall as specified and directed. (Note:-Punned thickness of sand shall be measured for payment).
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors drain of 40mm size complete all as specified and directed. Make of GI tubing:- Makes as mentioned in Appendix 'C'.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 2 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 150 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified. Note for Serial Item No 16 to 20:- Excavation & Earth work, cable cover, GI pipe and sand cushioning shall be measured and paid separetly under respective Items of BOQ.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 16 sqmm, complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 sqmm, complete all as specified.
Cable terminal box, outdoor type (heat shrinkable) complete with jointing material and accessories suitable for 1100 volts, XLPE aluminium conductor cable of size 16 to 25 sqmm, 2 core complete all as specified.
Cable terminal box, outdoor type (heat shrinkable) complete with jointing material and accessories suitable for 1100 volts, XLPE aluminium conductor cable of size 50 to 95 sqmm, 3.5 core complete all as specified.
Cable terminal box, outdoor type (heat shrinkable) complete with jointing material and accessories suitable for 1100 volts, XLPE aluminium conductor cable of size 120 to 185 sqmm, 3.5 core complete all as specified.
Cable route indicator made out of 2 mm thick mild steel sheet of size 20 cms X 15 cms duly coated with two coats of black paint over a coat of red oxide primer duly written the size of LT/ HT cable in white paint and welded to equal angle of size 30X30X3mm, 45 cms long and errected in ground in such a way that it is 15 cms above ground level and 30 cms below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-I, using 20 mm graded crushed stone aggregate of size 15 cms X 20 cms X 45 cms all as specified & directed. Note:- Cost of PCC and earth work & excavation shall be deemed to be included in unit rate quoted by contractor.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9 metres long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30 cms wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed.
Re-installing uprooted LT/ HT steel tubular swaged poles including reconnecting over head conductor complete (9/ 11 metres long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30 cms wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note for Serial Item No 27 & 28:- Excavation & EarthWork, PCC in foundations, coping etc shall be measured and paid under respective Items of BOQ.
Painting to existing steel tubular HT poles, 11.00 metres long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30 cms wide strips (Total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
Stay Assembly using stay rod of 20mm dia complete with accessories as shown in Electrical Plate No. 1 of SSR 2009 Part-I including galvanized steel stranded wire of size 7/4mm and taking out/ dismantling old stay assembly, complete all as specified (Loop type insulator, earth work and PCC shall be measured and paid for separately under respective items of Schedule 'A')
Renewal of loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 90 mm x 140 mm clearance of hole 25.5 mm, complete all as specified and directed.
Numbering of poles with synthetic enamel paint, all as specified and directed. Note:- Numbering shall be hand written only. Stencils emborsing shall not be allowed and size of letters shall be 50 mm X 10 mm (width and height of each letter).
Cutting/ trimming of trees branches from LT/ HT lines upto 2 metre horizontal & 2 metre vertical distance from both sides of electric line including shifting of cut trees branches away from site complete all as directed. Note:- (i) Clearing branches from both sides of conductor in between two consequtive poles shall be considered as one span irrespective of distance between poles. (ii) Cost of T&P required for cutting and removing branches shall be deemed to be included in rate quoted by bidder.
Replacement of existing unservicable Meter Box (For 4 No's single phase meter) with incoming 63 Amps MCB, TPN-01 No and Outgoing MCB SP 40 Amps-4 No's, thermoplastic Polycarbonate having IP-65 protection in accordance with EN 60 529, dust proof, water proof, acid and chemical resistant, fire retardant and self extinguishing, UV resistant, silica and halogen free recycable material, glow wire tested at 960°C in accordance with EIC 60 695-2-11 type tested as per IEC 60 439-1 totally insulated with system. The manufacturer of box/ panel shall submit a copy of CPRI test report of degree of ingress protection IP-65 in accordance with IEC 60529. The gasket material shall be polyurethane. The gasket shall be internally embeded. The manufacturer of board/ panel shall submit a copy of test report of board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The report shall have mention of following tests performed and passed out satisfactorily:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric properties. (d) Short circuit withstand current- Rated peak & short time withstand current and rated conditional short circuit current. (e) Effectiveness of protective circuits. (f) Clearance and creepage distance. (g) Mechanical operation. (h) The lid closing and opening shall be done by quick fastening spring mechanism latches. Suitable accessories for armored cable should be supplied with the panel. These accessories shall auto fit to avoid loss of IP.
Replacement of existing unservicable Meter Box (For 6 No's single phase meter) with incoming 63 Amps MCB, TPN-01 No and Outgoing MCB SP 40 Amps-6 No's, thermoplastic Polycarbonate having IP-65 protection in accordance with EN 60 529, dust proof, water proof, acid and chemical resistant, fire retardant and self extinguishing, UV resistant, silica and halogen free recycable material, glow wire tested at 960°C in accordance with EIC 60 695-2-11 type tested as per IEC 60 439-1 totally insulated with system. The manufacturer of box/ panel shall submit a copy of CPRI test report of degree of ingress protection IP-65 in accordance with IEC 60529. The gasket material shall be polyurethane. The gasket shall be internally embeded. The manufacturer of board/ panel shall submit a copy of test report of board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The report shall have mention of following tests performed and passed out satisfactorily:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric properties. (d) Short circuit withstand current- rated peak & short time withstand current and rated conditional short circuit current. (e) Effectiveness of protective circuits. (f) Clearance and creepage distance. (g) Mechanical operation. (h) The lid closing and opening shall be done by quick fastening spring mechanism latches. Suitable accessories for armored cable should be supplied with the panel. These accessories shall auto fit to avoid loss of IP. Note for Serial Item No 34 & 35:- Fixing of Meter Box on walls with suitable size of anchor bolts, making holes in walls, grouting in PCC M-15, type B-0 and making good disturbed surfaces to match with existing shall be deemed to be included in unit rate quoted by bidder.
Earthing complete with galvanised steel earth plate electrode 60 cms x 60 cms x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0 mm dia (as earth lead wire) by means of bolt, nuts, check nuts and washers of galvanised steel and earth wire protected by provision of galvanised iron pipe, light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-15, type B-1, using 20mm graded crushed stone aggregates with 40 mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25mm x 25 mm x 3 mm with lugs 2 No's with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom, 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32 X 6 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. Note for Serial Item No 36 & 37:- Item of earthing includes the cost of 7.50 metres long galvanised iron 32mm X 6mm strip/ 4mm GI wire along with GI protection pipe.
Supply, installation, commissioning and testing LT bus bar box (LT KIOSK), outdoor, cubical type, pedestal type factory made, CPRI approved, fabricated out of 3.15 mm thick mild steel sheet mounted on frame of mild steel angle iron 50 mm X 50 mm X 5 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm X 50 mm X 5 mm thick fixed on plain cement concrete foundation (As per manufacturer's instructions) having height 60 cms from ground level & 30 cms below ground level, built in plain cement concrete M-15, type B-0, using 12.5 mm graded crushed stone aggregate. Bus bar box shall be totally enclosed weather proof and vermin proof, self ventilated with front and rear opening (double door with neosprene gasket and locking arrangement) with IP-54 protection as per IS-8623 duly powder coated internally and externally with provision of two No's earth terminals on sides for 433 volts, 3 phase, 4 wire having TPN copper bus bars of 200 Amps rating, full for phase and half for neutral, duly drilled holes for connections mounted on epoxy/ porcelain insulators in totally enclosed chamber with three phase and neutral 415 volts, AC, RYB insulated with different color code and sleeved insulators complete prewired with PVC insulated, unsheathed, 1100 volt grade multistrand copper conductor cable upto bus bars, meters, MCCB's etc including all incoming and outgoing cable connection with suitable size of copper lugs/ gland including providing aprons at the bottom to avoid entry of vermins, reptiles and taking down/ dismantling old unservicable LT bus bar box complete all as specified and directed and also comprissing of following:-
(a) INCOMING (i) MCCB 160 Amps, 4 pole, 25KA breaking capacity, 415 volts with adjustable microprocessor release as incoming - 01 No (CAT Part No HHA161Z of "Hager" or equivalent in makes mentioned in Appendix 'C').
surinder kumar jindal bros
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .