Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.2 LAccepted-AOC NORTH BEYPORE CALICUT 15 KERALA | KOZHIKODE | KERALA | 612906 | 1 | Accepted-AOC l1 | |
| 2 | 2₹12.5 L+₹20,262 (1.65%)Rejected-Finance | 2 | Rejected-Finance l2 | |
| 3 | 3₹12.7 L+₹38,963 (3.17%)Rejected-Finance | 3 | Rejected-Finance l3 | |
| 4 | 4₹13.3 L+₹1.0 L (8.29%)Rejected-Finance | 4 | Rejected-Finance l4 |
Tender Value
₹12.7 L
EMD Value
₹31,777
Closing Date
28 Apr 2025, 6:00 pmClosed
Assistant Executive Engineer KYIP O and M Sub Div
Assistant Executive Engineer KYIP O and M Sub Div peruvannamoozhi
GENERAL-Budget work 2022-23-KyIP - Renovation of Koottalida Town in Kottur Panchayath of Balussery Constituency in Kozhikode District- Phase II (Between Ch.2/700 Km and 2/880 Km of Poonath Distributory)-Electrical works-General Electrical Work
2025_Irrig_755897_2
PWD/BLDG/TR/5430/2025_6_1_1/1
Open Tender
Electrical Works
Item Rate
270 days
Koottalida
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
Yes
₹31,777
Yes
2 Jun 2025
21 Apr 2025
30 Apr 2025
21 Apr 2025
28 Apr 2025
21 Apr 2025
Amount
Providing Street Lights
OD299227/2024-2025:Supply, installation, testing and commissioning of decorative pole 3.0M height above the ground level made out of GI, tubular pole ‘T’ washed and primered. (ASTM A123, with minimum average GI coating of 65μm.), having two sections, bottom section of minimum 1000mm (L) x 114mm dia and the top section with minimum of 2000mm (L) x 76mm dia, in built junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out. Design comply EN40 standard and basic wind speed 169kmph. The Embellishments are cast in iron and fitted to the column by grubs screw fitting. The embellishments shall be sealed to the column.The Pole Base plate should be with 200x200x14 mm. The column shall also be provided with flush door at the bottom with proper strengthening to the cut-out of the door opening. The Pole Shaft/pipe should be fabricated out of Steel tube of grade YST 210/240.. The pole shaft and base plate shall be hot dip galvanized (7stage process) as per IS 2629 having minimum average DFT of 65 microns before the coating of epoxy primer. The pole shall have inbuilt junction box consist of connector for loop in loop out and provision for MCB. The pole shall be of composite’ construction designed to ‘wind load’ corresponding to a basic wind speed of 169kmph without any deformation or damage to the structure. Make: KESSSLEC 3.0M RILA POLE WITH BASE PLATE/ Equivalent approved in engineer in charge.
OD299224/2024-2025:Supply, installation, testing and commissioning of Decorative classic LED street lantern, BIS certified with aluminaire body made of spun aluminium, permanently sealed optical block (IP66) with heatsink and an anti UV PC protector (IK09) fitted with a VentPlug pressure equalisation unit, fixed onto a hinged spun aluminium frame, control gear compartment for tool free opening and closing. Highly efficient temperature resistant lenses for symmetric or asymmetric light distribution with several optical options providing excellent photometry to optimally cater to different applications.Suitable for a galvanised painted mounting bracket for Post Top version.Overall system efficiency of 120lm/W at correlated colour temperature (CCT) of 3000K, colour rendering index (CRI) >70 (optional 80 CRI) and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10//10 KV( in both Common & Differential Modes).Make: Kesslec Hanoi 40W WW LED PT Version/ Equivalent approved in engineer in charge.
OD299228/2024-2025:Supply, installation, testing and commissioning of 9W LED Step Light luminaire, with a grey painted body and cover made of die-cast aluminium, a PMMA protector sealed to the body and a silicone gasket to achieve IP66 tightness level and making the luminaire suitable for outdoor use. The luminaire shall have impact resistance of IK07. An installation kit, made of polypropylene facilitates its installation in wall or stairs and making it blend into the architecture. The optics of the luminaire shall be designed for efficient asymmetric light distribution. Design life L70 shall not be less than 50,000 burning hours. Overall luminous efficiency of luminaire shall be 50 lm/W ± 7% at correlated colour temperature (CCT) of 3000K with tolerance as per ANSI standard, colour rendering index (CRI) 80. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.90 and THD < 15%. The luminaire shall have dimensions of The product complies with the essential safety requirements of the applicable BIS standard. Make: KEW NX 9W WW LED/ Equivalent approved in engineer in charge.
OD299234/2024-2025:Supply, installation, testing and commissioning of 9W LED Spike Light, BIS certified with a grey painted die casted aluminium body and a glass protector tightened with the body to achieve IP66 protection and making the luminaire suitable for outdoor use. Available with a mounting bracket which makes it possible to adjust and incline precisely on-site. It can be mounted on a wall or on the ground with spike.The optics of the luminaire shall be designed forefficient symmetric light distribution. Design life shall not be less than 30,000 burning hours. The light engine shall incorporate COB in the Luminaires. Overall luminous efficiency of luminaire shall be 70 Lm/W ± 7% at correlated colour temperature (CCT) of 3000K with tolerance as per ANSI standard, colour rendering index (CRI) 80. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.90 and THD < 15%. Shall be supplied precabled for easy installation.The product complies with the essential safety requirements of the applicable BIS standard. Make: KESSLEC PENZA 9W WW LED/ Equivalent approved in engineer in charge.
OD299230/2024-2025:Supply, installation, testing and commissioning of Bollard 9W LED, BIS certified with a luminaire body made of aluminium, IP66 optical block with heat sink and a clear PMMA protector (optional PC protector(K10).Dimensions xH(mm)100x500 Highly efficient symmetric light distribution providing excellent photometry to maximise the spacing between the bollards. Suitable for on-ground mounting on 4xM10 bolts on 100mm PCD. Overall system efficiency of 120lm/W at correlated colour temperature (CCT) of 3000K, colour rendering index (CRI) >70and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, PowerFactor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV (in both Common & Differential Modes). Make: Kesslec ANNA BOLLARD 9W WW LED/ Equivalent approved in engineer in charge.
90.15.3.1:Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.6:Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD299225/2024-2025:Supply and fixing Syntex junction box GSJB 1616 (155mm X 155mm X 100mm) with provision for fixing SP/DP MCB for terminating street light cable.
OD299226/2024-2025:Supply and providing 16 A, 240 V 3 way open type bakelite connector strip in existing junction box and giving connections as required
90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
14.13.2:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required80 mm dia
14.13.3:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD299214/2024-2025:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 40/32 mm or nearest size
OD299221/2024-2025:Supply & laying of DWC pipe through the wall/ parapet using clamps noted along with the DWC pipe, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 40/32 mm or nearest size
OD299217/2024-2025:Supply & laying of DWC pipe through the wall/ parapet using clamps noted along with the DWC pipe, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 50/38 mm or nearest size
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD299229/2024-2025:Supply Conveyance, installation, testing and commissioning of 40A, double pole, single phase 240 volts, MCB type change over switch in the existing MCB DB complete with connections. Make L&T AU series Cat No. AUC00204000 or equivalent
OD299231/2024-2025:Supplying and fixing 32A 4pole AC1 Power contactor in the existing MCB DB/enclosure complete with connections,testing and commissioning etc. as required. Make L&T MCX 03 series Cat No. CS97011BOOO or equivalent
OD299233/2024-2025:Supplying and fixing 24 Hours Timer for operating ON-OFF fuction in the existing MCB DB/enclosure complete with connections,testing and commissioning etc. as required make L&T GIC Time Switch Crono 110-240VAC 1 C/O Base/DIN 25 ON/OFF Model no:67DDT0
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD299218/2024-2025:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
OD299213/2024-2025:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD299219/2024-2025:Supply and providing 25x3mm brass nut and bolt etc. as required
OD299222/2024-2025:Supply and providing 25x6mm brass nut and bolt etc. as required
OD299235/2024-2025:Supply and providing and fixing 32ASP&N disconnector fuse switch unit in sheet steel enclosure with ISI marked including HRC fuse link on wall/angle iron frame including drilling holes in frame, making connections, etc. as required (Front Handle type).
OD299232/2024-2025:Supply & installation of dust and vermin proof, 1 Phase Syntex Meter Board( GS-MB-4030) and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required.
OD299212/2024-2025:Supply and fixing 32A Fuse base with HRC fuse link in the existing meter board and giving connections etc.
OD299220/2024-2025:Supply and fixing 32A, 2 way neutral link mounted on DMC/ SMC base in the existing box and giving connections etc. as required
OD299216/2024-2025:Supply and fixing 4 pole porcelain terminal connector inside the pole for connecting the in coming and outgoing cable ends and light leads to the lamp in the pole.
OD299223/2024-2025:Supply and providing suitable Iron Hook grouted on wall for binding the service wire as required.
OD299215/2024-2025:Supply and fixing Danger notice board of size, 125 x 75 mm
OD299236/2024-2025:Dismantling the existing 8 metre mini mast light with octagonal pole including round arm bracket and luminaries from the existing position and re fixing the same to the new position including fixing foundation bolts 4 nos , without any damages of pole and luminaries including connection, testing complete etc. as required.
MUHAMMAD (BID ID -2201721)
SOUBHAGYA ENGINEERING COMPANY (BID ID -2200061)
POURNAMI (BID ID -2202463)
Bidder Name
SOUBHAGYA ENGINEERING COMPANY
gopakumar.kv
MUHAMMAD
POURNAMI
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1237598.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .