Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC ASSAM AS | ₹3.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.6 Cr+₹6.7 L (1.91%)Rejected-AOC | ₹3.6 Cr+₹6.7 L (1.91%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.6 Cr+₹9.3 L (2.66%)Rejected-AOC WARD NO 5 TENGAPARA P O P S DIST KOKRAJHAR PIN 783370 | KOKRAJHAR | ASSAM | 783370 | ₹3.6 Cr+₹9.3 L (2.66%) | L3 | Rejected-AOC L3 |
Tender Value
₹3.5 Cr
EMD Value
₹6.9 L
Closing Date
14 Oct 2019, 4:30 pmClosed
Addl. Chief Engineer cum Director
Office of the Addl. Chief Engineer cum Director, PWD, BTC, Kkrajhar
Setting up of Old Age Home at Bedlangmari in Kokrajhar District for the financial year 2018-2019. Package No.TN No.45_01
2019_BTC_14249_1
144/ACE/PWD/BTC/2018-19/04
Open Tender
Civil Works - Building
Item Rate
730 days
Bedlangmari
Refer to SBD
6 documents required · 6 mandatory
₹10,400
Principal Secretary, BTC, Kokrajhar.
₹6.9 L
Yes
22 Jan 2020
26 Sept 2019
15 Oct 2019
26 Sept 2019
14 Oct 2019
26 Sept 2019
Amount
CIVIL WORKS: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.(a).Brick on flat soling.Footing,Below Floor
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement : 3 sand : 6 coarse aggregate by volume
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(b) In prop 1cement : 4 sand : 8 coarse aggregate by volume
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth level, Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticiser , c) M20 grade concrete
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth level, Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticiser, a) M15 grade concrete, c) M20 grade concrete
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine, (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine, (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser a) M15 grade concrete
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (i) Using 38mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200 mm in thickness.
MASONARY WORK , In superstructure above plinth level up to 1st floor level, (b) In proportion 1:4.(1 cement:4 sand)
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall, (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
CERAMIC TILES , A) ON WALLS, Providing polished ceramic wall tiles of approved quality ,size , shape and thickness not less than 8 mm on walls , skirtingsover cement mortar bed 10mm thl. In prop. 1:3 including cutting ..........as approved and directed by the department (wall means both interior and exterior ) , a) Normal Range (somany/orient/nitco/quotone make), i) of size 200 x 200 mm and above
(A) FLOOR TILES, Providing ceramic tiles of approved quality ,size , shape and thickness not less than 8 mm on floors , skirtings,trade and risers of steps over cement mortar bed 15mm thl. In prop. 1:3 including cutting ..........as approved and directed by the department, c) Delux Range (somany/orient/nitco/quotone make), i) size 300 x 300 mm and above
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) , a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make, ii) Of size 600mmx600mm and above
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side, b) In cement mortar 1:4 , i) For Building- Inside wall, i) For Ground Floor & 1st Floor, External wall UPTO PLINTH
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side, b) In cement mortar 1:4 , i) For Building- Inside wall, i) For Ground Floor & 1st Floor, External wall UPTO PLINTH, Extra over item no 6.2.1 to 6.2.3 for plastering on ceiling and soffit of stairs p to 1st floor level (instead of plastering on walls)including curing complete as directed
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) (iv) 0.50 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement, (iv) 0.50 mm thick
Providing wood work in frame (chowkaths) of doors,windows,clerestory windows and other similary works wrought,framed and fixed in position in contact with C.C or brick masonry wal including supplying fitting and fixing with M.S hold fast (40 mm x 3 mm x250mm)as per design embeded in cement concrete block in proportion 1:2:4 and and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With first class timber (bonsun/sundi)
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.) (ii) 35 mm thick.
Providing ,fitting ,fixing steel windows/ventilators (fixed) of standard rolled sections as per relevant I.S. Code ,joints mitred and welded with 15mmx13mmx1000mm lugs embeded in conc. Block of M10 grade including applying a coat of red leard paint .
Providing , fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal galzing bars , joints mitred and welded ……….as specified and directed for all levels, b) 3 track sliding window, (i) 6mm clear glass
Providing , fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal galzing bars , joints mitred and welded fitted with 6mm x 3.15mm lugs 100mm long embeded in cc blocks……….as specified and directed for all levels, a) side hung and top hung window and ventilators, (i) 6mm clear glass
Providing, fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats fixed to the columns/stiffeners/walls with necessary holdfast/ sleeves etc. as specified and directed at all levells.
Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately), b) 29mm thick
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint, wood primer (white)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) , a) Sliding door bolts, ii) 250mm x 16mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ), b) Tower bolts, iii) 200mm x 12mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ), c) Door handles, ii) 100mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ), t) Door stopper with rubber stopper
Providing and fixing in position collapsible M.S shutter with vertical channels 20 mm x10mm x 2 mm braced with flat iron diagonals 20 mm x 5 mm x size with top and bottom rails of T- iron 40mm x40mm x 6 mm with 38 mm dia steel pulleys complete with bolts and nuts, locking arrangements ,stooppers ,handles including applying a priming coat of red lead paint.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) , a) From Primary Producer : TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel/ RINL, (i) TMT Corrosion resistant steel (CRS) reiforcement bar
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. b) Using other ISI marked approved brand tube
65mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 and 15mm thk. Wearing layer in cement concrete in prop. 1:1:2 laid in panels and finished with a floating coat of bond @ 2.75 kg per sq.m of floor area incl. curing etc. complete as directed
Proving plinth protection 50mm thick to cement concrete 1:3:6 with course agg. Of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floating coat of neat cement finished.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
SANITARY: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement : 3 sand : 6 coarse aggregate by volume
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary, (d) In proportion 1:6.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in sub-structure upto plinth level. (A) 112mm thick brick wall, (c) In cement mortar in proportion 1:6. (1 cement:4 sand)
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side, b) In cement mortar 1:4
Neat Cement Punning
Providing fitting and fixing PVC cowel of ISI make complete as directed and specefied , (II) 110 mm dia PVC cowel ISI make
Construction of filter bed in soak pit including earth eork of soil and filing earth..................as mention in the table .
Construction of inspection pit.......... As directed
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110 mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (iv) 75 mm dia.
DEEP TUBE WELL: Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department., ii) Bore hole of 100 mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. a) TATA / SAIL (Medium)socket should be welded to the pipes. vi) 75 mm diameter
Supplying fitting and fixing brass Tez filter 2.00 metre long.
Supplying fitting and fixing check valve (non return valve) including thread to pipes. iv) 50mm diameter
Flushing, clearing, washing and watering of the tube well
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt., Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 2 HP STAGE 6 to 30 with MCB controlled Submersible motor pump set control panel.
PAVEMENT WORKS: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Plain/Reinforcement cement concerte,in open foundation complete as per drawing and technical specification including steel shuttering formwork , i) PCC Grade M15
FIRE FIGHTING: Supply , Installatiuon, Fixing of ABC Stored Pressure Fire Extingusher with built- In pressure Gauge to know the ready ness of the Extinguisher Squeeze Grip Handle As per IS: 13849 with ISI mark (05 kg capacity.) Brand: FIRESTOP / FIREND / FIRESHIELD
Supply , Installatiuon, Fixing of CARBON DIOXIDE Fire Extinguisher conforming to IS: 2878 with ISI Mark (4.5 lt.) Brand: FIRESTOP / FIREND / FIRESHIELD
PLUMBING WORKS: Supplying and placing plastic cylinder vertical claused top (PCVC) tank Sintex / Polycon / Patton make over the staging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes . 2000 lts capacity SINTEX MAKE
Supplying and placing plastic cylinder vertical claused top (PCVC) tank Sintex / Polycon / Patton make over the staging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes . 1500 Lts capacity Sintex Make
Supplying and placing plastic cylinder vertical claused top (PCVC) tank Sintex / Polycon / Patton make over the staging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes . 1000 Lts capacity SINTEX MAKE
Providing fitting and fixing viterous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors wherever required .(flushing cistern to be paid separately ), Indian type W.C Orissa pattern of size 580x440 mm, (a) white, i) Parryware make
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately), i.) Parryware make, a) white, (i) Universal Closet S trap (Cat NO. CO271) (Anglo Indian ) inclusive of seat cover
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make/a) White/(i)Economy Single Flush (Cat No.C8090/C8055)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately), 1.13.2. Basin (with out pedestal) (A).(a) (i) Star Basin 550x400 (cat. No. C0450)
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified. (iv) SONA make
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately), II) Jaquare make/ (a)Continental /Clarion, (i)Standard
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately), (I) Jaquar/(a) Continental / Clarion/(ii)15mm dia( Angular stop cock )
Supplying, fitting and fixing Ajoy flowguard CPVC pipes............testing of joints complete at all levels as directed and specified. i. Internal wall- exposed on wall. a. 15mm OD
Supplying, fitting and fixing Ajoy flowguard CPVC pipes............testing of joints complete at all levels as directed and specified. i. Internal wall- exposed on wall . b. 20mm OD
Supplying, fitting and fixing Ajoy flowguard CPVC pipes............testing of joints complete at all levels as directed and specified. i. Internal wall- exposed on wall. c.25mm OD
Providing , fitting , fixing stainless steel kitchen sink of parryware ................ As required, A/(iii) Single Bowl with Drain Board(360x180) flat edge-glossy.
Socket, Reducing Socket, Renewing G.I. Socket Zololot -m brand ,heavy, a. 15mm OD
Socket, Reducing Socket, Renewing G.I. Socket Zololot -m brand ,heavy,b. 20mm OD
Socket, Reducing Socket, Renewing G.I. Socket Zololot -m brand ,heavy, c.25mm OD
BEND, Renewing G.I. BEND ,heavy quality as specified and directed, a. 15mm OD
BEND, Renewing G.I. BEND ,heavy quality as specified and directed, b. 20mm OD
BEND, Renewing G.I. BEND ,heavy quality as specified and directed, c.25mm OD
TEE, REDUCING TEE, REDUCER, Renewing G.I. TEE ,heavy quality as specified and directed, a. 15mm OD
TEE, REDUCING TEE, REDUCER, Renewing G.I. TEE ,heavy quality as specified and directed, b. 20mm OD
TEE, REDUCING TEE, REDUCER, Renewing G.I. TEE ,heavy quality as specified and directed, c.25mm OD
RCC STAGING: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering , complete. (a).Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX), (For Assam Type Bldg., drain works, retaining wall & boundary wall etc.)
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face, i) For R.C.C. in Ground Floor upto 1st floor level
Side and soffits of beam, beam haunching , cantilever girders , bressumers , lontels and horizontal ties, for depth not exceeding 1.00 m
Flat Surfaces such as soffits of suspended floors, roofs , landings cantilever slabs , chajjas, balconies and the like , (c) Floors etc. Upto 200 mm in thickness
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine, (A) In substructure up to plinth level, Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser, a) M15grade concrete or Prop. 1:2:4
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine, (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser, a) M15 grade concrete or Prop. 1:2:4
Brick work in cement mortar with 1 st class brick including racking out joints and curing complete as directed, (III) In Sub-structure upto plinth level including dewatering if necessary , (C) In prop. 1:5
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level. (A) 112mm thick brick wall, (a) In cement mortar in proportion 1:5.
65mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 and 15mm thk. Wearing layer in cement concrete in prop. 1:1:2 laid in panels and finished with a floating coat of bond @ 2.75 kg per sq.m of floor area incl. curing etc. complete as directed
Providing fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats to the column / stiffeners / walls with necessary holdfats / sleeves etc. As specified and directed at all levels .
Providing fitting and fixing 24mm / 29mm thick polymer reinforced mounded PVC door shutters fixed to the chowkhat with necessary hinges, screws , bolts etc. As specified and directed at all levels ( Door fixtures and fittings to be measured and paid separately ) . (a) 24mm thick
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side, b) In cement mortar 1:5
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
Supplying fitting and fixing M.S angles M.S. Flat M.S. Bolts and nuts including painting with red lead paint one coat complete as directed (a) M.S Angles ....(40 x 40 x 6 ) mm @ 3.5 kg / Rm.
Supplying fitting and fixing M.S angles M.S. Flat M.S. Bolts and nuts including painting with red lead paint one coat complete as directed (a) M.S Angles ....(40 x6 ) mm @ 1.89 kg / Rm.
LANDSCAPING: Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (A) With Aeirides, (I) Using earthen pot of 30 cm dia.
Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (A) With Aeirides, (II) Using earthen pot of 60 cm dia.
Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (A) With Aeirides, (III) Using concrete pot of 60 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (A) With Bottle palm, (I) Using earthen pot of 30 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (A) With Bottle palm, (II) Using earthen pot of 60 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (A) With Bottle palm, (III) Using concrete pot of 60 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (D) With Fan Palm /Finger palm, (I) Using earthen pot of 30 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (D) With Fan Palm /Finger palm, (II) Using earthen pot of 60 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (D) With Fan Palm /Finger palm, (III) Using concrete pot of 60 cm dia.
Supplying and planting of seasonal flower in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (I) Using earthen pot of 30 cm dia.
Supplying and planting of seasonal flower in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (II) Using earthen pot of 60 cm dia.
Supplying and planting of seasonal flower in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned), (III) Using concrete pot of 60 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)(A) With Peanut Cactus / Rat tail Cactus, (I) Using earthen pot of 30 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)(A) With Peanut Cactus / Rat tail Cactus, (II) Using earthen pot of 60 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)(A) With Peanut Cactus / Rat tail Cactus, (III) Using concrete pot of 60 cm dia
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (B) With Prickly pear ,(I) Using earthen pot of 30 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (B) With Prickly pear , (II) Using earthen pot of 60 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (B) With Prickly pear , (III) Using concrete pot of 60 cm dia
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (C) With Parodia globular, (I) Using earthen pot of 30 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (C) With Parodia globular, (II) Using earthen pot of 60 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (C) With Parodia globular, (III) Using concrete pot of 60 cm dia
Supplying and planting of Dahlia / Chrysanthemum / Gladiolus on the ground ( bed planting, bed size 45 cm x 45 cm x 45 cm) including the preparation of the soil, providing organic manure and fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed .
Supplying and planting of suitable plant materials for preparation protective / external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD, (i) With Duranta
Supplying and planting of suitable plant materials for preparation protective / external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD, (ii) With Kamini
Supplying and planting of suitable plant materials for preparation protective / external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD, (iii) With Chinese Bamboo
Supplying and planting of suitable plant materials for preparation protective / external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD, (iv) With Thuja / Ixora
Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD, (i) With Duranta
Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD, (ii) With Coleus
Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD, (iii) With Brindavan / Latifolius
Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD, (iv) With Acalypha wilkesiana
Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD, (v) With Acer palmatum
FOUNTAIN: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) Brick on flat soling.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.(a) Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.(I) In Sub-structure upto plinth level including dewatering if necessary, (d) In proportion 1:6.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (II) In superstructure above plinth level up to 1st floor level.(b) In proportion 1:4.(1 cement:4 sand)
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side, b)In cement Morter 1:4
Neat Cement Punning, FOR FLOOR
BOUNDARY WALL: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.a) In ordinary Soil
Providng soling in foundation and under floor with stone / best quality picked jhama brick ,sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materils and if necessary , Column Base
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.100mm thick, (b) In prop 1:4:8 ,Column Base
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (A) In sub structure upto plinth level ,b) M 15 grade (1:1.5:3)
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super Structure from plinth level upto 1st Floor level, (i) Column pillar post struts, b) M15 or Prop 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:Foundation ,Footing ,bases of column, (b) Using 25 mm thick plank , Column, COLUMN Upto GL.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:Sides of Tie Beam, (ii) Using 25 mm thick Plank
squre, Rectangular,ploygonal,in plan or any shape loke Tee/L etc. having plane vertical face.Column
squre, Rectangular,ploygonal,in plan or any shape loke Tee/L etc. having plane vertical face.Tie Beam
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer : TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel/ RINL, (II) Super Ductile (SD) TMT reinforcement, 8 mm Tor Rod @ 0.39 / Kg/R.M, 12 mm Tor Rod For column @ 0.89 kg/RM, 16 mm Tor Rod for Tie Beam @ 1.58 kg/RM
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer : TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel/ RINL, ISI approved M.S bars 6 mm dia M.S Rod, Post stirrups, Above GL.Tie Beam,P/Rod @ 0.22 Kg/Rm
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed in sub- Structure of the plinth level, C) In proportion 1:5, Partition wall
112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth upto 1st floor level, b) In proportion 1;4
15 mm thick cement plastering in single coat on fair side of brick / concrete works etc, (b) In proportion 1:4
Finishing wall with water proofing cement post of approved brand to give an even , Quantity same as plaster
Supply fitting fixing M.S angles,M.S. flat ,M.S bolt and nuts including painting with red lead paint one coat complete as directed,(a) M.S angle (40mm x 40 mm x 2mm)
providing barbed wire
EARTH FILLING: Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods,dressing etc. complete including paying nessary forest royelty,sales tax,land compensation,municipal gate fees,if any monopoly duty etc.(profile measurement to be taken and 12.5%deduction for shinkage to be made from total quantity)etc.conplete as directed and specified.( b.) other than guwahati city. Shrinkage 12%
ELECTRICAL-1: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.1 Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.2 Medium point up to 6.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.3 Long point up to 10.00 metre. length.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 X 2.5 sq. mm + earth continuity with 1 X 1.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 X 4 sq. mm + earth continuity with 1 X 2.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.3 With 2 X 6 sq. mm + earth continuity with 1 X 4 sq. mm in flat 25 mm ISI marked casing 'n' capping system.
1.10 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.10.4 With 4 X 10 sq. mm + earth continuity with 2 X 6 sq. mm in flat 32 mm ISI marked casing 'n' capping system.
1.11 Wiring to 5 a pin 6 Amps plug point with 1.50 sq. mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 volts with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR cable or equivalent make as approved by the Deptt.)including providing and fixing 5 pin 6 Amp socket outlet (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) earthing the 3rd pin of the socket as requiredc on the switch board in ISI marked casing and capping system, when fitted on same board of light and fan.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G. 25 cm long cast plate and brass lamp holder complete including connection as approved by the deptt. As required (without Lamp).
11.16 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the department as required (without lamp).
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
15.4 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust vermin proof Double door (ID-43) surface mounting SPN MCB DB incorporated with bas-bar, N- link, Earth wire able etc. fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved and specified as directed by the deptt. 15.4.1 (Schneider neo break, C & S, Havells, Standard, or equivalent as aopproved by the deptt.) 15.4.1.1 4 way SPN double door.
15.8 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1 (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 15.8.1.1 4way TPN (4+12) double door.
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B Series (Schneider MG, legrand, Hager, Crabtree Xpro make make) 16.1.1.1 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1 B series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.3.1.2 40A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.6.1 B series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.6.1.3 63A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt 5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper, earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the department [Without regulator] 27.1.3 Premium model 1400 mm sweep. (ORIENT PSPO make) /Premium model 1400 mm sweep ss-390 Deco. (Havells make).
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1 Domestic. 27.2.1.2 Power flux 225 mm sweep (Orient make)
27.6 Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic type
32.1 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV grade solid standed conductor XLPE insulated, cores laid up, PVC tape inner sheathed, Armour(Aluminium for single core upto 70sq. mm balance Allminium strip, Galvanised for cables up to 2 X 10 sq.mm, 3 X 10 sq. mm, 4 x 6 sq.mm balance all galvanized steel strip) , extruded PVC type ST2 sheathed, 650/1100 V Graded as per IS 7908(Part - I) 1988 armoured U.G. cable U.G cable laid in ground/partically in air (as required for termination over ground including excavation of cable trench up to depth of 75 cm, refilling, protective brick covering, sand cushioning etc. complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (NICCO/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivalent) 32.1.1 2 core A2XWaY A2XFaY. 32.1.1.1 4.00 sq.mm 2core armoured U.G. cable.
32.1 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV grade solid standed conductor XLPE insulated, cores laid up, PVC tape inner sheathed, Armour(Aluminium for single core upto 70sq. mm balance Allminium strip, Galvanised for cables up to 2 X 10 sq.mm, 3 X 10 sq. mm, 4 x 6 sq.mm balance all galvanized steel strip) , extruded PVC type ST2 sheathed, 650/1100 V Graded as per IS 7908(Part - I) 1988 armoured U.G. cable U.G cable laid in ground/partically in air (as required for termination over ground including excavation of cable trench up to depth of 75 cm, refilling, protective brick covering, sand cushioning etc. complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (NICCO/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivalent) 32.1.1 2 core A2XWaY A2XFaY. 32.1.1.2 6.00 sq.mm 2core armoured U.G. cable.
39.3 Supplying including installation, connection as approved by the deptt. Testing and commissioning of CENTRIFUNGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. Testing and commissioning of CENTRIFUNGAL VERTICAL PUMP SET complete as directed as directed and specified by the deptt. 39.3.4 2HP Single phase centrifugal mono block pump set (Crompton Greaves/Aquatic/CRI/V Gourd/Calma make) 2900 rpm with DOL Starter (Crompton Greaves/Control & Switch Gear/BCH/L&T/Siemens make).
ECBC 3.25 Supplying and fixing of jaquar or equivalent Philips/ Wipro LED outdoor light fittings complete with all accessories including connection cable as approved by the deptt. Etc. as required. ECBC 3.25.3 LED Garden Light 12W/16W.
ECBC 3.28 Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ceiling including connection with 1.5 sq.mm PVC insulated S.C. copper conductor as required and as directed by the department. ECBC.3.28.1. LED Lamp indoor application, operating voltage 90V-250V 12V DC 1. Model GN111-2 or equivalent, LED Lamp with Main input (Make Philips/Bajaj/Schneider/Havells)
Annexure-1 Supplying with fitting and fixing of three phase Digital type Energy Metre with ASEB Tested service connection including load security, metre security connection charge etc. complete with all necessary materials and accessories as required and specified by the department.
ELECTRICAL-2: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.1 Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.2 Medium point up to 6.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.3 Long point up to 10.00 metre. length.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 X 2.5 sq. mm + earth continuity with 1 X 1.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 X 4 sq. mm + earth continuity with 1 X 2.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.3 With 2 X 6 sq. mm + earth continuity with 1 X 4 sq. mm in flat 25 mm ISI marked casing 'n' capping system.
1.11 Wiring to 5 a pin 6 Amps plug point with 1.50 sq. mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 volts with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR cable or equivalent make as approved by the Deptt.)including providing and fixing 5 pin 6 Amp socket outlet (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) earthing the 3rd pin of the socket as requiredc on the switch board in ISI marked casing and capping system, when fitted on same board of light and fan.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G. 25 cm long cast plate and brass lamp holder complete including connection as approved by the deptt. As required (without Lamp).
11.16 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the department as required (without lamp).
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
15.4 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust vermin proof Double door (ID-43) surface mounting SPN MCB DB incorporated with bas-bar, N- link, Earth wire able etc. fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved and specified as directed by the deptt. 15.4.1 (Schneider neo break, C & S, Havells, Standard, or equivalent as aopproved by the deptt.) 15.4.1.1 4 way SPN double door.
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B Series (Schneider MG, legrand, Hager, Crabtree Xpro make make) 16.1.1.1 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1 B series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.3.1.2 40A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt 5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper, earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the department [Without regulator] 27.1.3 Premium model 1400 mm sweep. (ORIENT PSPO make) /Premium model 1400 mm sweep ss-390 Deco. (Havells make).
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1 Domestic. 27.2.1.2 Power flux 225 mm sweep (Orient make)
27.6 Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic type
39.3 Supplying including installation, connection as approved by the deptt. Testing and commissioning of CENTRIFUNGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. Testing and commissioning of CENTRIFUNGAL VERTICAL PUMP SET complete as directed as directed and specified by the deptt. 39.3.2 1HP Single phase centrifugal mono block pump set (Crompton Greaves/CRI/V Gourd/Calma make) With DOL Starter (Crompton Greaves/Control & Switch Gear/BCH/L&T/Siemens make).
ECBC 3.28 Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ceiling including connection with 1.5 sq.mm PVC insulated S.C. copper conductor as required and as directed by the department. ECBC.3.28.1. LED Lamp indoor application, operating voltage 90V-250V 12V DC 1. Model GN111-2 or equivalent, LED Lamp with Main input (Make Philips/Bajaj/Schneider/Havells)
ELECTRICAL-3: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.1 Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.2 Medium point up to 6.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.3 Long point up to 10.00 metre. length.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 X 2.5 sq. mm + earth continuity with 1 X 1.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 X 4 sq. mm + earth continuity with 1 X 2.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.3 With 2 X 6 sq. mm + earth continuity with 1 X 4 sq. mm in flat 25 mm ISI marked casing 'n' capping system.
1.11 Wiring to 5 a pin 6 Amps plug point with 1.50 sq. mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 volts with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR cable or equivalent make as approved by the Deptt.)including providing and fixing 5 pin 6 Amp socket outlet (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) earthing the 3rd pin of the socket as requiredc on the switch board in ISI marked casing and capping system, when fitted on same board of light and fan.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G. 25 cm long cast plate and brass lamp holder complete including connection as approved by the deptt. As required (without Lamp).
11.16 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the department as required (without lamp).
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
15.4 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust vermin proof Double door (ID-43) surface mounting SPN MCB DB incorporated with bas-bar, N- link, Earth wire able etc. fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved and specified as directed by the deptt. 15.4.1 (Schneider neo break, C & S, Havells, Standard, or equivalent as aopproved by the deptt.) 15.4.1.1 4 way SPN double door.
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B Series (Schneider MG, legrand, Hager, Crabtree Xpro make make) 16.1.1.1 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1 B series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.3.1.2 40A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt 5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper, earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the department [Without regulator] 27.1.3 Premium model 1400 mm sweep. (ORIENT PSPO make) /Premium model 1400 mm sweep ss-390 Deco. (Havells make).
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1 Domestic. 27.2.1.2 Power flux 225 mm sweep (Orient make)
27.6 Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic type
39.3 Supplying including installation, connection as approved by the deptt. Testing and commissioning of CENTRIFUNGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. Testing and commissioning of CENTRIFUNGAL VERTICAL PUMP SET complete as directed as directed and specified by the deptt. 39.3.2 1HP Single phase centrifugal mono block pump set (Crompton Greaves/CRI/V Gourd/Calma make) With DOL Starter (Crompton Greaves/Control & Switch Gear/BCH/L&T/Siemens make).
ECBC 3.28 Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ceiling including connection with 1.5 sq.mm PVC insulated S.C. copper conductor as required and as directed by the department. ECBC.3.28.1. LED Lamp indoor application, operating voltage 90V-250V 12V DC 1. Model GN111-2 or equivalent, LED Lamp with Main input (Make Philips/Bajaj/Schneider/Havells)
ELECTRICAL-4: 2.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2 mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/AKG/Precision/Presto Plast/polycab/MW or equivalent makes as approved by the Deptt.) including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked)with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete. 2.1.1 Short point up to 3.00 metre. length.
2.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2 mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/AKG/Precision/Presto Plast/polycab/MW or equivalent makes as approved by the Deptt.) including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked)with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete. 2.1.2 Medium point up to 6.00 metre. length.
2.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2 mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/AKG/Precision/Presto Plast/polycab/MW or equivalent makes as approved by the Deptt.) including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked)with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete . 2.1.3 Long point up to 10.00 metre. length.
2.2 Wiring to 5 a pin 6 Amps plug point with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed 2 mm thick/heavy rigid ISI marked IS: 9537 Part - III rigid PVC conduit (Berlia/AKG/Precision/Presto Plast/polycab/MW or equivalent makes as approved by the Deptt.) wiring system including 5 pin 6 Amp flush type plug socket and 6 Amps F/T switch (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 2.2.2 Medium point up to 6.00 metre length.
2.3 Wiring for 5/6 pin 16 Amp power plug point with 4 mm. P.V.C. insulated S.C. unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR kable or equivalent make) in surface/recessed conduit wiring system including and fixing 5/6 pin 15 Amp flush type socket out let and 16Amps flush type switch (Anchor penta/gold medal/kolor kany.kom or equivalent make) G.I/ M.S. switch board (ISI) marked with phenolic laminated switch cover including earth continuity with 2.5 mm2 cable to the 3rd pin of the socket as required complete with 20mm dia. 2 mm thick/heavy ISI marked IS : 9537 part-II PVC conduit (Berlia/AKW/ Presto plast or equivalent make as approved by the dept. 2.2.2 Medium point up to 6.00 metre length.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.1 With 2 X 2.5sq.mm + earth continuity with 1 X 1.5 sq.mm in 20mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.2 With 2 X 4sq.mm + earth continuity with 1 X 2.5 sq.mm in 20mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.3 With 2 X 6sq.mm + earth continuity with 1 X 4 sq.mm in 25mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.9 Wiring for drawing sub-main line with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed PVC 20mm dia. 2mm thick/heavy ISI marked IS:9537PART- III rigid PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/M.W or equivalent make as approved by the deptt.) Wiring system. 2.9.4 With 4 X 10 sq.mm + earth continuity with 2 X 6 sq.mm cable in 40 mm dia 2mm thick/heavy rigid PVC IS: 9537 Part-III conduit.
2.10 Wiring for 5 pin 6 Amp plug with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable or equivalent make as approved by the deptt.) including 5 pin 6 Amp socket outlet (Anchor Penta/Gold medal/ Kolors kany.kom/havells or equivalent make as approved by the deptt.) and 6 amp flush type switch (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) make earthing the 3rd pin of the socket as required on the switch boared in surface/recessed PVC conduit wiring system. When fitted on same boared of light and fan.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G. 25 cm long cast plate and brass lamp holder complete including connection as approved by the deptt. As required (without Lamp).
11.16 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the department as required (without lamp).
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
11.32 Supplying and fixing of Cell bell (Buzzer) including 5/6 amp capacity button piano type bell push switch including connection as approved by the Deptt. as required.
15.4 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust vermin proof Double door (ID-43) surface mounting SPN MCB DB incorporated with bas-bar, N- link, Earth wire able etc. fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved and specified as directed by the deptt. 15.4.1 (Schneider neo break, C & S, Havells, Standard, or equivalent as aopproved by the deptt.) 15.4.1.1 4 way SPN double door.
15.8 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1 (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 15.8.1.1 4way TPN (4+12) double door.
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B Series (Schneider MG, legrand, Hager, Crabtree Xpro make make) 16.1.1.1 6 to 32A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt 5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper, earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
ECBC 3.28 Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ceiling including connection with 1.5 sq.mm PVC insulated S.C. copper conductor as required and as directed by the department. ECBC.3.28.1. LED Lamp indoor application, operating voltage 90V-250V 12V DC 1. Model GN111-2 or equivalent, LED Lamp with Main input (Make Philips/Bajaj/Schneider/Havells)
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the department [Without regulator]. 27.1.3 Premium model 1400 mm sweep. (ORIENT PSPO make) /Premium model 1400 mm sweep ss-390 Deco. (Havells make).
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1 Domestic. 27.2.1.2 Power flux 225 mm sweep (Orient make).
27.6 Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic type.
30.11 Supplying with fitting and fixing single phase D.O. starter of the following specification complete including making necessary connection as approved, specified and directed by the deptt. 30.11.1 Overload Realy Range 6.0-9.3 Amps for 3.7 KW.
31.1 Supplying with fitting and fixing Voltage stabilizerof the following specification complete including making necessary connection as approved, specified and directed by the (SKYLAND/Vee-Dee/V GUARD/VERTEX/INDO/VENUS make. 31..1.6 3.0 KVA Automatic input 90-280 V out put 200-240V.
ECBC 7.3 Supplying with installation, testing and commissioning of HI-wall 5STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable as approved by the department up to 5 m between the room unit and out door unit as directed by the department. ECBC 7.3.1.3 Dalkin make/ Carriec Aircon make estrella/ Mitsubhishi make Starmax Series Model MS-18 + MU-18, Rotary type compressor/ Blue Star make Model 5HW 18 DBF1/ Model 5HW18ZBW/Model 5HW18ZBS.
ELECTRICAL-5: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.1 Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.2 Medium point up to 6.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.3 Long point up to 10.00 metre. length.
1.3 Wiring for 5/6 pin 16 Amps power plug point with 4 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 Volts with flexible bright annealed to electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6Amps F/T switch (Anchor Penta/Gold medal/ kolor kany.com/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, earth continuity with 2.5 sq mm cable to 3rd pin of the socket as required complete. 1.3.2. Medium point up to 6.00 metre length.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 X 2.5 sq. mm + earth continuity with 1 X 1.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 X 4 sq. mm + earth continuity with 1 X 2.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.3 With 2 X 6 sq. mm + earth continuity with 1 X 4 sq. mm in flat 25 mm ISI marked casing 'n' capping system.
1.11 Wiring to 5 a pin 6 Amps plug point with 1.50 sq. mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 volts with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR cable or equivalent make as approved by the Deptt.)including providing and fixing 5 pin 6 Amp socket outlet (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) earthing the 3rd pin of the socket as requiredc on the switch board in ISI marked casing and capping system, when fitted on same board of light and fan.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G. 25 cm long cast plate and brass lamp holder complete including connection as approved by the deptt. As required (without Lamp).
11.16 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the department as required (without lamp).
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
11.32 Supplying and fixing of Cell bell (Buzzer) including 5/6 amp capacity button piano type bell push switch including connection as approved by the Deptt. as required.
15.4 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust vermin proof Double door (ID-43) surface mounting SPN MCB DB incorporated with bas-bar, N- link, Earth wire able etc. fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved and specified as directed by the deptt. 15.4.1 (Schneider neo break, C & S, Havells, Standard, or equivalent as aopproved by the deptt.) 15.4.1.1 4 way SPN double door.
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B Series (Schneider MG, legrand, Hager, Crabtree Xpro make make) 16.1.1.1 6 to 32A
16.3 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1 B series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.3.1.2 40A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt 5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper, earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the department [Without regulator] 27.1.3 Premium model 1400 mm sweep. (ORIENT PSPO make) /Premium model 1400 mm sweep ss-390 Deco. (Havells make).
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1 Domestic. 27.2.1.2 Power flux 225 mm sweep (Orient make)
27.6 Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic type
39.3 Supplying including installation, connection as approved by the deptt. Testing and commissioning of CENTRIFUNGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. Testing and commissioning of CENTRIFUNGAL VERTICAL PUMP SET complete as directed as directed and specified by the deptt. 39.3.2 1HP Single phase centrifugal mono block pump set (Crompton Greaves/CRI/V Gourd/Calma make) With DOL Starter (Crompton Greaves/Control & Switch Gear/BCH/L&T/Siemens make).
ECBC 3.28 Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ceiling including connection with 1.5 sq.mm PVC insulated S.C. copper conductor as required and as directed by the department. ECBC.3.28.1. LED Lamp indoor application, operating voltage 90V-250V 12V DC 1. Model GN111-2 or equivalent, LED Lamp with Main input (Make Philips/Bajaj/Schneider/Havells)
ELECTRICAL-6: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.1 Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.2 Medium point up to 6.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.3 Long point up to 10.00 metre. length.
1.3 Wiring for 5/6 pin 16 Amps power plug point with 4 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 Volts with flexible bright annealed to electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6Amps F/T switch (Anchor Penta/Gold medal/ kolor kany.com/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, earth continuity with 2.5 sq mm cable to 3rd pin of the socket as required complete. 1.3.2. Medium point up to 6.00 metre length.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 X 2.5 sq. mm + earth continuity with 1 X 1.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 X 4 sq. mm + earth continuity with 1 X 2.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.3 With 2 X 6 sq. mm + earth continuity with 1 X 4 sq. mm in flat 25 mm ISI marked casing 'n' capping system.
1.11 Wiring to 5 a pin 6 Amps plug point with 1.50 sq. mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 volts with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR cable or equivalent make as approved by the Deptt.)including providing and fixing 5 pin 6 Amp socket outlet (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) earthing the 3rd pin of the socket as requiredc on the switch board in ISI marked casing and capping system, when fitted on same board of light and fan.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G. 25 cm long cast plate and brass lamp holder complete including connection as approved by the deptt. As required (without Lamp).
11.16 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the department as required (without lamp).
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
11.32 Supplying and fixing of Cell bell (Buzzer) including 5/6 amp capacity button piano type bell push switch including connection as approved by the Deptt. as required.
15.2 Supplying with fitting and fixing sheet steel, phosphatised powder painted dust & vermin proof double door (IP-43) surface mounting SPN MCB DB incorporated with bus bar Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts and bolts as required complete with making necessary connection as approved, specified as directed by the department. 15.2.1 (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make make) 15.2.1.1 4 way SPN Double Door.
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B Series (Schneider MG, legrand, Hager, Crabtree Xpro make make) 16.1.1.1 6 to 32A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt 5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper, earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the department [Without regulator] 27.1.7 Standard model 1400 mm sweep (Orient PSPO make) Usha make/ Crompton make/ Havells make/ ATC/ V guard make.
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1 Domestic. 27.2.1.2 Power flux 225 mm sweep (Orient make)
27.6 Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic type
39.3 Supplying including installation, connection as approved by the deptt. Testing and commissioning of CENTRIFUNGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. Testing and commissioning of CENTRIFUNGAL VERTICAL PUMP SET complete as directed as directed and specified by the deptt. 39.3.2 1HP Single phase centrifugal mono block pump set (Crompton Greaves/CRI/V Gourd/Calma make) With DOL Starter (Crompton Greaves/Control & Switch Gear/BCH/L&T/Siemens make).
ECBC 3.28 Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ceiling including connection with 1.5 sq.mm PVC insulated S.C. copper conductor as required and as directed by the department. ECBC.3.28.1. LED Lamp indoor application, operating voltage 90V-250V 12V DC 1. Model GN111-2 or equivalent, LED Lamp with Main input (Make Philips/Bajaj/Schneider/Havells)
ELECTRICAL-7: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.1 Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.2 Medium point up to 6.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.3 Long point up to 10.00 metre. length.
1.3 Wiring for 5/6 pin 16 Amps power plug point with 4 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 Volts with flexible bright annealed to electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6Amps F/T switch (Anchor Penta/Gold medal/ kolor kany.com/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, earth continuity with 2.5 sq mm cable to 3rd pin of the socket as required complete. 1.3.2. Medium point up to 6.00 metre length.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 X 2.5 sq. mm + earth continuity with 1 X 1.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 X 4 sq. mm + earth continuity with 1 X 2.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.3 With 2 X 6 sq. mm + earth continuity with 1 X 4 sq. mm in flat 25 mm ISI marked casing 'n' capping system.
1.11 Wiring to 5 a pin 6 Amps plug point with 1.50 sq. mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 volts with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR cable or equivalent make as approved by the Deptt.)including providing and fixing 5 pin 6 Amp socket outlet (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) earthing the 3rd pin of the socket as requiredc on the switch board in ISI marked casing and capping system, when fitted on same board of light and fan.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G. 25 cm long cast plate and brass lamp holder complete including connection as approved by the deptt. As required (without Lamp).
11.16 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the department as required (without lamp).
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
11.32 Supplying and fixing of Cell bell (Buzzer) including 5/6 amp capacity button piano type bell push switch including connection as approved by the Deptt. as required.
15.2 Supplying with fitting and fixing sheet steel, phosphatised powder painted dust & vermin proof double door (IP-43) surface mounting SPN MCB DB incorporated with bus bar Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts and bolts as required complete with making necessary connection as approved, specified as directed by the department. 15.2.1 (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make make) 15.2.1.1 4 way SPN Double Door.
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B Series (Schneider MG, legrand, Hager, Crabtree Xpro make make) 16.1.1.1 6 to 32A
16.3 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1 B series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.3.1.2 40A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt 5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper, earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the department [Without regulator] 27.1.3 Premium model 1400 mm sweep. (ORIENT PSPO make) /Premium model 1400 mm sweep ss-390 Deco. (Havells make).
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1 Domestic. 27.2.1.2 Power flux 225 mm sweep (Orient make)
27.6 Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic type
ECBC 3.28 Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ceiling including connection with 1.5 sq.mm PVC insulated S.C. copper conductor as required and as directed by the department. ECBC.3.28.1. LED Lamp indoor application, operating voltage 90V-250V 12V DC 1. Model GN111-2 or equivalent, LED Lamp with Main input (Make Philips/Bajaj/Schneider/Havells)
ELECTRICAL-8: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.1 Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.2 Medium point up to 6.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.3 Long point up to 10.00 metre. length.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 X 2.5 sq. mm + earth continuity with 1 X 1.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.8 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deppt.) in surface flat ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 X 4 sq. mm + earth continuity with 1 X 2.5 sq. mm in flat 19mm ISI marked casing 'n' capping system.
1.11 Wiring to 5 a pin 6 Amps plug point with 1.50 sq. mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 volts with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR cable or equivalent make as approved by the Deptt.)including providing and fixing 5 pin 6 Amp socket outlet (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) earthing the 3rd pin of the socket as requiredc on the switch board in ISI marked casing and capping system, when fitted on same board of light and fan.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G. 25 cm long cast plate and brass lamp holder complete including connection as approved by the deptt. As required (without Lamp).
11.16 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the department as required (without lamp).
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
15.4 Supplying with fitting fixing sheet steel, phosphatised powder painted dust vermin proof double door (ID-43) surface mounting SPN MCB DB incorporated with bus bar N- link earth wire able etc. fitted on wall with grounting nuts and bolts as required complete with making necessary connection as approved and specified as directed by the department. 15.4.1 (Schneider neo break, C & S, Havells, Standard, or equivalent as approved by the deptt.) 15.4.1.1 4way SPN double door.
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B Series (Schneider MG, legrand, Hager, Crabtree Xpro make make) 16.1.1.1 6 to 32A
16.3 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1 B series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.3.1.1 6 A to 32A.
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt 5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper, earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the as required complete and as directed by the department [Without regulator] 27.1.7 Standard model 1400 mm sweep (Orient PSPO make) Usha make/ Crompton make/ Havells make/ ATC/ V guard make.
ECBC 3.28 Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ceiling including connection with 1.5 sq.mm PVC insulated S.C. copper conductor as required and as directed by the department. ECBC.3.28.1. LED Lamp indoor application, operating voltage 90V-250V 12V DC 1. Model GN111-2 or equivalent, LED Lamp with Main input (Make Philips/Bajaj/Schneider/Havells)
27.6 Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic type
Maniraj Brahma
GAUTAM BRAHMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .