General Manager (Engg)-IV
HIDCO BHABAN
Upkeeping of building cooling and ventilation system of New Town Exhibition Centre in New Town, Kolkata.
2026_HIDCO_1045184_1
HIDCO/GM(E)IV/CS/NIT14/26-27
Open Tender
CIVIL WORKS
Item Rate
60 days
NEW TOWN
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹10,000
7 Oct 2026
7 Oct 2026
28 Oct 2026
7 Oct 2026
26 Oct 2026
7 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Correction and rectification of all fire damper actuator connections and their interfacing with the fire alarm panel, to make the fire damper system fully functional and responsive to fire signals, for approximately 28 fire dampers installed across the Exhibition Centre ductwork. The work comprises inspection of each fire damper's electro-thermal/electro-mechanical actuator, checking and rectification of loose, damaged or incorrectly wired connections between the actuator, the damper's fusible link/smoke detector, and the fire alarm control panel, taking the fire signal from the respective fire zone module, replacement of damaged wiring, terminals, relays or actuator components as found necessary, and verification of the damper's fail-safe closing action upon simulated fire/smoke signal from the fire panel. Each damper shall be tested for smooth manual reset after closure, correct blade seating for smoke/fire-tight closure, and correct signal feedback (open/close status) to the fire panel/BMS, where provided. A record of testing for each of the approximately 28 dampers shall be maintained and submitted to the Engineer-in-Charge. Rate shall be inclusive of wiring, connectors, minor spares, labour, testing instruments and coordination with the fire alarm system, treated as one lot covering all dampers, complete as required, all complete as directed by the Engineer-in-Charge. | 1 | Lot | 100 | ₹100 |
| 2 | Supplying, Installation, Testing and Commissioning (SITC) of Galvanised Iron (GI) volume control duct damper of the required size, for regulating and balancing airflow within the Exhibition Centre ductwork, complete with neoprene rubber gaskets at the flanged connection, nuts, bolts, screws, operating linkage/quadrant lever and locking arrangement, in conformity with SMACNA/IS standards and as per specifications. The work comprises fabrication or supply of the damper frame and blade/louvre assembly from GI sheet of adequate gauge, fitting of the damper within a cut-out section of the ductwork with a flanged and gasketed connection to ensure air-tight fixing, provision of an external operating quadrant/lever with a locking screw for setting and holding the desired blade angle, and sealing of the surrounding duct joint after fixing. After installation, the damper shall be tested through its full range of movement, fully open to fully closed, for smooth and stiction-free operation, and airflow through the branch shall be balanced and locked at the required setting using an anemometer or equivalent instrument. Rate shall be inclusive of damper, gaskets, hardware, fixing, labour, tools, testing and air balancing, measured per square metre of damper face area, complete as required, all complete as directed by the Engineer-in-Charge. | 16 | sqm | 100 | ₹1,600 |
| 3 | Repairing and/or calibration of pressure gauges, thermostats and temperature sensors installed on the AHU/chilled water system of the Exhibition Centre, to restore accurate monitoring and control of system operating parameters. The work comprises isolation of the instrument, removal from its tapping/mounting point, inspection for physical damage, dial/needle malfunction, bourdon tube leakage in the case of pressure gauges, or sensor drift/broken capillary in the case of thermostats and temperature sensors, repair using genuine or compatible spare parts including glass, needle, bourdon element, sensing bulb, capillary tubing and terminal connectors as applicable, followed by calibration against a certified reference standard across the full operating range. Where repair is found not feasible, the instrument shall be replaced with a new unit of identical range, accuracy class and connection size, subject to approval of the Engineer-in-Charge. After calibration or replacement, the instrument shall be refitted at its original location complete with isolation valve/pocket, leak-tested where applicable, and functionally verified against actual system readings. Rate shall be inclusive of spares, calibration charges, labour, testing instruments and making good, complete per instrument as required, all complete in all respects as directed by the Engineer-in-Charge. | 12 | Each | 100 | ₹1,200 |
| 4 | Supply, Installation, Testing and Commissioning (SITC) of Fibre Reinforced Plastic (FRP) protective coating over the condenser water pipe of various sizes running in the cooling tower area and plant room of the Exhibition Centre, for approximately 210 running metres of pipe of various diameters, to arrest external corrosion and extend the service life of the piping. The work comprises surface preparation of the existing pipe by wire brushing/grinding to remove rust, scale and loose paint down to a sound metal surface, application of a suitable anti-corrosive base coat and primer paint compatible with the FRP system, followed by application of FRP coating comprising resin-impregnated glass fibre mat/cloth wrapped and laminated over the pipe surface in the requisite number of layers to achieve adequate coating thickness and mechanical strength, with special attention to pipe joints, bends, supports and flange faces. The coating shall be cured as per the resin manufacturer's recommendation and finished with a smooth, pinhole-free, weather and chemical resistant surface. Rate shall be inclusive of all materials (resin, glass fibre mat, primer, base paint), consumables, scaffolding, labour and tools, treated as one lot for the approximate pipe length specified, complete as required, all complete as directed by the Engineer-in-Charge. | 1 | Lot | 100 | ₹100 |
| 5 | Repairing and restoring the existing old cooling tower(s) to proper serviceable condition, including sealing of leaks in the Fibre Reinforced Plastic (FRP) cold water basin, to eliminate water loss and restore efficient heat rejection performance. The work comprises draining down and thorough cleaning of the cooling tower basin, fill media, drift eliminators and casing to remove algae, scale and debris, detailed inspection to locate cracks, punctures, delamination or leakage points in the FRP basin and casing panels, surface preparation of the affected areas by grinding/roughening, and repair using compatible FRP resin, glass fibre mat/chopped strand and gel coat, laminated in layers to achieve a sound, leak-proof and structurally adequate patch, properly cured and finished flush with the surrounding surface. Damaged/corroded fasteners, gaskets and access door seals shall be replaced. Fan blades, motor, gearbox, fill media and the float valve shall be checked and serviced/adjusted for smooth operation. After repair, the basin shall be filled and checked for leak-tightness, and the tower run-tested for correct water flow, drift and fan operation. Rate shall be inclusive of materials, labour, tools and testing, complete per each cooling tower as required, all complete as directed by the Engineer-in-Charge. | 3 | Each | 100 | ₹300 |
| 6 | Supply and replacement of air filters for all Air Handling Units (AHU) and Cassette/Ceiling Handling Units (CHU) installed at the Convention Centre, comprising removal of existing choked/damaged filter media (pre-filters of washable/synthetic non-woven fabric, 10-micron average efficiency, and fine filters as applicable) from the filter section of each unit, and supply and fixing of new filters of matching size, micron rating and efficiency class (EU3/G3 for pre-filter and EU5/F5 for fine filter, or as existing), duly fitted in the filter frame/track with proper gasket sealing to prevent bypass air leakage. The work includes cleaning of filter housing, frame and mounting channel prior to fixing the new filter, checking of the filter clamping arrangement, and visual/manometric verification of pressure drop across the filter after installation. Old and discarded filters shall be removed from site and disposed of as per site instructions. The work shall be carried out AHU-wise and CHU-wise strictly as per the direction and schedule of the Engineer-in-Charge (EIC), without disrupting HVAC operation of unaffected areas. Rate shall be inclusive of all material, labour, tools, tackles, scaffolding/ladder, transportation, loading-unloading and disposal of waste, complete in all respects as directed. | 100 | Each | 100 | ₹10,000 |
| 7 | Chemical cleaning and washing of the Air Handling Unit (AHU) cooling coil (fins) using an approved alkaline foaming coil cleaner to remove accumulated dust, grease, biological growth and scaling from the fin surface and coil tubes, thereby restoring heat transfer efficiency and airflow. The work comprises isolation and safe shutdown of the AHU, removal of access panels, protection of the surrounding motor, VFD, electricals and insulation from the cleaning chemical using polythene sheeting, application of the foaming cleaner uniformly over both faces of the coil, allowing the prescribed dwell/reaction time, followed by thorough rinsing with clean water using a low-pressure jet/spray without damaging the fins, and combing/straightening of any bent fins to restore fin spacing. The drain pan shall be cleaned of sludge and biological deposits, the drain trap and drain line checked for free flow, and the casing interior wiped clean and disinfected. After cleaning, the AHU shall be run and checked for leak-free operation, correct condensate drainage and improved delta-T across the coil. Rate to include all chemicals, consumables, protective sheeting, labour, tools, testing and making good, complete per AHU as required, all complete as directed by the Engineer-in-Charge. | 14 | Each | 100 | ₹1,400 |
| 8 | Supply, repair and commissioning of existing HVAC MCC AHU control panel including: inspection and fault diagnosis of MCB/MCCB, contactors, relays, timers and control wiring; replacement of burnt/damaged contactors, overload relays, indicating lamps, selector switches and terminal blocks with ISI-marked components of matching rating; cleaning and tightening of all power/control terminations; checking and calibration of thermostat/sensor circuits; testing of interlocks, phase-failure relay and earth continuity; touch-up painting of panel enclosure; providing insulation/IR test report and functional trial run of connected AHU/chiller units. Rate to include labour, consumables, testing instruments, and 6-month warranty on replaced items , all complete as directed by the Engineer-in-Charge. | 14 | Nos | 100 | ₹1,400 |
| 9 | Comprehensive repair and servicing of existing chilled water cassette-type AC units comprising: dismantling of front grille, panel and filters for inspection; chemical/foam cleaning of evaporator coil, condensate drain pan and drain line including flushing to clear chokes; cleaning and balancing of blower wheel and washable filters; isolation and draining of local chilled water circuit; removal of faulty motorized chilled water control valve and installation of new valve of matching size, pressure rating and make (Honeywell/Belimo/Siemens or equivalent); supply and fixing of compatible electric/spring-return valve actuator with proper wiring, control interfacing and calibration to existing thermostat/BMS signal; refilling and venting of chilled water circuit with pressure/leak testing at all joints; insulation of exposed pipe and valve joints with nitrile rubber insulation; checking/repair of condensate pump and float switch; re-fixing of panel/grille; and final functional trial run verifying cooling, flow modulation and control response. Rate inclusive of labour, consumables, tools and 12-month warranty on replaced items, all complete as directed by the Engineer-in-Charge. | 15 | Nos | 100 | ₹1,500 |
| 10 | Add GST @18% of total amount of Sl No-1 to 9 | 1 | No | 10 | ₹10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
2911_FORM.pdf
Tender Documents • 0.16 MB
Specialtermsandcondition_GM4.pdf
Tender Documents • 0.68 MB
TENDERDOCUMENT.pdf
Tender Documents • 0.59 MB
BOQ_2562539.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .