DEPUTY EXECUTIVE ENGINEER, MEHSANA ELECTRICAL (R&B) SUB DIVISION, MEHSANA
Repairs to Street lights On Visnagar Unjha Road, State Highway, Dist. Mehsana.
356678
13/12 OF 2026/2027
Open
Electrical
Works
Mehsana
7 documents required · 7 mandatory
₹900
Executive Engineer, Mehsana Electrical (R&B) Division, Mehsana
₹7,200
18 Oct 2026
18 Oct 2026
18 Oct 2026
3 Nov 2026
18 Oct 2026
120 days
Name of Work : Repairs to Street lights On Visnagar Unjha Road, State Highway, Dist.
Rate at which the materials will be
SR Quantity Perticulars Place of delivery
charged to the contractor
Dy. Executive Engineer, Executive Engineer,
Mahesna Electrical (R&B) Sub Division Mehsana Electrical (R&B) Division
Mahesana Mehsana
Name of Work : Repairs to Street lights On Visnagar Unjha Road, State Highway, Dist. Mehsana.
Description Qty. Unit Rate in words Amount
1 Replacing old & U/S by new Supplying and erecting LED street light / Flood
light fittings with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with company mark/name engraved
or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %,
CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-
80 certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must 115 Nos 5581.26 Rupees Five Thousand Five hundred
have 440VAC line supply with over-voltage protection. Eighty One Paise Twenty Six Only
(iv) 90 - 119 watts
2 Replacing old & U/S by new providing and erecting Miniature circuit 30 Nos 297.95 Rupees Two hundred Ninety Seven
breaker single pole 0.5A to 2A system and having breaking capacity 10 Paise Ninety Five Only
KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
3 Replacing old & U/S by New Supplying & erecting approved make SMC 5 Nos 476.72 Rupees Four hundred Seventy Six Paise
press moulded composite FRP. loop-in, loop-out approx. 2mm thick box Seventy Two Only
complete with Bakelite connector strip 5way(3P+N+E),DIN rail for
mounting mob & hinged doors as per requirement having locking
arrangements with mounting clamp with nuts, bolts & washers suitable for
erection on pole with cable clamps& earth bolt of following size of box.
(C)150mm x 125mm x 100mm [deep]
4 Replacing old & U/S by New Providing and erecting FRLS- 50 Mtr 846.38 Rupees Eight hundred Forty Six Paise
XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Thirty Eight Only
for 1.1 kV. to be laid on wall with necessary clamps or in existing trench
/ pipe at road crossing or floor of following size of cables.
(A) 4 core 10 Sq. mm
5 Replacing old & U/S by new Supplying and erecting Flexible PVC insulated 360 Mtr. 58.58 Rupees Fifty Eight Paise Fifty Eight
multi strand multi core 1.1 kv grade ISI marked copper wires of following Only
size to be erected as directed.
(e) 1.50 Sq.mm 3 core round PVC sheathed
Rupees Seven Lakh Sixteen thousand Five hundred Seventy Four Paise Eighty Only
I / We am / are willing to carry out the work at ___________________________
above / below _________________________ percent ( should be written in figures and words )
below / above the tendered rates mentioned above. below / above the tendered rates mentioned above.
Amount of my / our tender works out as under :-
Estimated amount Estimated amount
put to be tender Rs. _____________ put to be tender Rs. _____________
Deduct ______% below Rs. _____________ Add ______% above Rs. _____________
In words :- In words :-
* Please strike out whichever is not applicable.
1. I / We hereby declare that I / We have visited the site and fully acquited myself / ourselves
with the local situtaion regarding materials, labour and other factors pertaining the work
before submeeting this tender.
2. I / We hereby declare that I / We have carefully studied conditions of contractors,
specifications and other the tender documents of this work and agree to work execute that
same accordingly.
3. DM Must Be Deducted From The Bill.
Dy. Executive Engineer, Executive Engineer,
Mahesna Electrical (R&B) Sub Division Mehsana Electrical (R&B) Division
Mahesana Mehsana
Dismental Material List
Name of Work : Repairs to Street lights On Visnagar Unjha Road, State Highway, Dist. Mehsana.
ITEM DETAILS QTY Unit AMOUNT
NO. RATE AGE RATE
1 Cost of Old & U/S 1.5X3 Wire 340 Nos 55.00 11 6.05
2 Cost of Old & U/S Street light 90 Watt 110 Nos 5381.00 4 215.24
3 Cost of Old & U/S 4X10 Allu Armour Cable 50 Mtr 815.00 6 48.9
4 Cost of Old & U/S SMC Box 5 Nos 429.00 5 21.45
5 Cost of Old & U/S SP MCB 6-25 26 Nos 108.00 5 5.4
Dy. Executive Engineer, Executive Engineer,
Mehsana Electrical sub. Div. Mehsana Electrical( R & B ) Division
Mehsana Mehsana
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
12 visnagar make.pdf
G S T LTR.pdf
GR.pdf
NOTICE NO 13.pdf
PQ CRETERIA.pdf
schedule a b and dm.pdf
STANDARD BIDDING DOCUMENTS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .