Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | ₹13.4 L Quoted ₹14.3 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹15.1 L+₹83,844 (5.88%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹15.1 L+₹83,844 (5.88%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹15.5 L+₹1.2 L (8.56%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | ₹15.5 L+₹1.2 L (8.56%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹16.3 L+₹2.1 L (14.6%)Rejected-Finance 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | ₹16.3 L+₹2.1 L (14.6%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹16.9 L+₹2.6 L (18.5%)Rejected-Finance | ₹16.9 L+₹2.6 L (18.5%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
15 Dec 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
REPAIR / MAINTENANCE OF TRANSFORMER, HT CABLE, GOD, TWO POLE STRUCTURE INCLUDING ALLIED E/M WORKS AT INS DWARKA AND 7M DET OKHA UNDER GE NAVY PORBANDAR
2022_MES_561829_1
8809/Okha/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹28,000
Yes
5 Jan 2023
22 Nov 2022
16 Dec 2022
22 Nov 2022
15 Dec 2022
9 Dec 2022
23 Nov 2022 - 6 Dec 2022
Amount
Taking out old cork sheet Top Cover gasket of transformer of 100 KVA to 250 KVA and Supply & fix new super quality gasket of 4mm thickness including making smooth finish of new gasket checking fo leakage complete all as specified and directed. Note :- Gasket shall be replaced at no extra cost if leakage found after replcement of gasket.
Diconnecting & taking out old unserviceable LV bushings complete from transformer of 100 KVA to 250 KVA/100 KVA servo stabilizer and Supply and fix new LV bushings set of three with brass metal part including brass nuts with washers of suitable size inside and outside of the bushings, insulator and reconnecting the LV lead and testing after completion complete upto the satisfaction of Engr-in-Charge.
Diconnecting & taking out old unserviceable HV bushings complete from transformer of 100 KVA to 250 KVA and Supply and fix new HV bushings set of three with brass metal part including brass nuts with washers of suitable size inside and outside of the bushings, insulator and reconnecting the HV lead and testing after completion complete upto the satisfaction of Engr--Charge.
Silica gel for existing transformer complete all as specified and directed.
Testing of dielectric strength of transformer oil of indoor/outdoor type transformer, 11KV/433Volt and indoor voltage stabilizer of capacity 10KVA to 250KVA 433Volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified and directed. (Note: Transformer oil will be measured & paid seperately.)
Supply and toping of transformer oil with 40KV di-electric strength Transformer and Servo voltage stabilizer Oil conforming to IS 335 of 1993 complete all as specified and directed.
Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade fixed in repair / replacement complete all as specified and directed.
Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable of 11000 Volts fixed in repair / replacement complete all as specified and directed.
M & L for scrapping out old painted surfaces of transformer of 100/160/250 KVA and 10 to 250 KVA servo stabilizer,APFC panel upto 160 KVAR and making smooth exposed surfaces and applying two coat of synthetic enamel paint (smoke gray shade) complete all as specified and directed.
DO fuse for 11 KV 200 Amps set of three Frequency 50 Hz rated breaking capacity as per IS 93853 insulator D type fixed in repair / replacement complete all as specified and directed.
Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts fixed in repair / replacement complete all as specified and directed.
Servo stabilizer circuit card (PCB) suitable for three phase stabilizer 10 KVA to 250 KVA (Volina) make as per existing fixed in repair / replacement complete all as specified and directed.
Servo stabilizer multi fuctional meter suitable for three phase stabilizer 10 KVA to 250 KVA (Volina) make as per existing fixed in repair / replacement complete all as specified and directed.
Servo stabilizer motor upto 10 KG with RC suitable for three phase stabilizer 10 KVA to 250 KVA (Volina) make as per existing fixed in repair / replacement complete all as specified and directed.
Servo stabilizer Dimmer per phase upto 28 AMP suitable for three phase stabilizer 10 KVA to 20 KVA (Volina) make as per existing fixed in repair / replacement complete all as specified and directed.
Servo stabilizer Dimmer per phase150 AMP suitable for three phase stabilizer 100 KVA volina make as per existing fixed in repair / replacement complete all as specified and directed.
Servo stabilizer transformer per phase upto 20 KVA as per existing fixed in repair / replacement complete all as specified and directed.
Servo stabilizer transformer per phase 100 KVA as per existing fixed in repair / replacement complete all as specified and directed.
Supply and fixing Lug aluminium suitable cable size of 95 to 300 sqmm complete all as specified and directed by Engineer-in-Charge.
Painting to RCC pole 11.0 meters (2 pole/4 pole structure) meters long with two coats of synthetic enamel paint complete all as directed and specified.
Material and labour for numbering of pole no. using radium sticker of superier quality with back of Black round and fonts with white in colour complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Glvanized earth plate connected with GI earth strip 25x4mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 40 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover, fixed in repairs, including testing on completion complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Galvanised earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for laying cable and getting out in hard dense soil complete as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and directed.
Removing of excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed.
Unreinforced precast concrete cable cover, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified and directed.
Galvanised tubing light grade 80 mm nominal bore for passing of cable, fixed to poles / walls / laying under floor/ roads complete with and including fittings, clamps nut bolts as required complete all as specified and as directed.
Supply ,install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 95 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply ,install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 120 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note for item No. 31.00 & 32.00 :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Supply and fixing switch air break gang operated out door type HT 11 KV triple poles 400 Amps air break fittings type with fixed contacts of phosphorus bronze and moving contacts of copper with mechanically operating from ground level vertical mounted completed with HT insulator on steel frame operating rod made out of 25mm GI pipe medium grade worked from ground level with handle and locking arrangement with 12 insulators with drop out fuses with test complete all as specified and directed.
Cross arms, bracing, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending, cold or hot, drilling holes for bolts in any shape or size as directed including two coats of aluminium paint (under and finishing coat) over a coat of red oxide primer complete all as specified and directed.
Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 95sqmm 3core suitable for working on 11000 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
400 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 35 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment (Ics=100% of Icu) of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
MCB TP 25 to 63 AMP 415V 10 KA 'B' curve miniature circuit breaker (MCB) of 25 to 63 AMP 415V 10 KA current carrying capacity in the DB complete with connection testing and commissioning fixed in repair / replacement complete all as specified and directed by Engineer - in - Charge.
Opening the bus bar and rear panel of LT Panel board (01 Nos incoming and upto 08 Nos outgoing), disconnecting the cables from the busbars, replacement of suitable size of aluminium lugs of various size (25 sq mm to 300 sq mm) through desired method, replacement of burnt out nuts/bolts, replacement of cable glands, replacement of internal wiring, replacement of partially burnt out bus bar (if required) taking down carefully the copper/aluminium bus bar as required at site, scrapping the bus bar by emery paper for removing the silt/carbon, replacement of PVC insulation tape (RYB) and assembling the bus bar, LT Panel board complete for testing complete all as specified and directed.
Power capacitor 20 KVAR complete all as specified and directed.
Power capacitor 15 KVAR complete all as specified and directed.
Power capacitor 10 KVAR complete all as specified and directed.
Power capacitor 5 KVAR complete all as specified and directed.
Power contactor for UA 50-30-00RA APFC panel capacitor 3 phase supply complete all as specified and directed.
Power contactor for UA 26-30-10RA APFC panel capacitor 3 phase supply complete all as specified and directed.
Power contactor for UA 09-30-10RA APFC panel capacitor 3 phase supply complete all as specified and directed.
Digital 3 phase Digital Panel Voltmeter suitable size as per existing complete al as specified and as directed.
Digital 3 phase Digital Panel Ammeter suitable size as per existing complete al as specified and as directed.
Phase Indicating LED light RYB and ON off light set suitable size of existing panel complete al as specified and as directed.
APFC Panel internal wiring with PVC insulated, solid copper conductor cables, 1100 V suitable of 16 Sqmm/10 sqmm/6 sqmm/2.5 smmm/1.5 sqmm size fixed in repair / replacement complete all as specified and directed.
Power factor controller relay 12 stage Microprocessor based, modular type, intelligent APFC relay capable of having self-adjustment to any capacitor value suitable to maintain power factor between 0.95 to 0.99 with digital indication of power factor. Auto power factor improvement capacitor panel having aggregate capacity of existing APFC panel in 12 stage with microprocessor based control, factory made indoor type, floor mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system IEC/EN 81010 fixed in repair / replacement complete all as specified and directed.
Cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination, heat shrinkable type complete with jointing material and accessories suitable for 3core XLPE armoured aluminium conductor cable of size 95 sqmm fixing complete all as specified and as directed.
Cable jointing kit for 1100 V (Earthed) grade cable for Straight through joint heat shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm complete all as specified and directed by Engr-in-Charge.
SURESH ELECTRICALS
K K Construction Co
Rameshwar Enterprise
SANVI ASSOCIATES
ABR Trading Co
M/s. Vimal Enterprise
Harsh Infrastructure
RAJ ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .