CWE Dehradun
HQ CWE Dehradun The Mall Road Dehradun Cantt
MANNING OPERATION AND MAINTENANCEOF 11 KV INSTALLATION HT LT OH LINE UG CABLE LT PANEL AND CONNECTED WORKS IN BIRPUR AND 116 MTN BDE AREA UNDER GE DEHRADUN
2021_MES_420806_2
9598/DDN/31/E8
Open Tender
Civil Works
Item Rate
334 days
Dehradun
As per NIT
8 documents required · 8 mandatory
₹500
GE Dehradun
₹99,600
Yes
16 Apr 2021
17 Mar 2021
3 Apr 2021
17 Mar 2021
1 Apr 2021
18 Mar 2021
Amount
Sch 'A' Part -I for Item No. 1.00 to 3.00
Providing services for daily running maintenance and operation of Main Sub Station Birpur round the clock for VCB's, and other equipment installed at sub station switch yard including keeping the electrical installations operational and healthy condition and carrying out all daily, weekly and monthly preventive maintenance as per Indian electricity rules/Engineering practices and as per manufacturer's instruction, or as stated in particular specification incl attend fault/ breakdown in HT/LT Over Head line/ under ground cable due to any reason like falling of tree branches, Bird hits, Cracking of Pin/ Disc insulator, breaking Over Head conductor complete including patrolling of LT line, Meggering, removing of fault, replacement of insulator any type, replacement of fuses and restoring the feeder complete including keeping proper day to day records of maintenance activities (to be maintained in printed log sheets) etc complete with qualified technical staff along with proper safety devices, gloves, discharge rod, search light and T&P etc complete. Operational and manning staff as below shall be employed for 11 KV Sub Station Birpur cantt and its all incoming from MRS Garhi cantt to Birpur/ Ghunghora cantt and further outgoing feeder in Birpur/ Ghunghora cantt :-
The Sub station Birpur comprising of the following major equipment such as :- (i) 11 KV Feeder from MRS Garhi catt33/11 KV to Sub Station Birpur/ Ghunghora. (ii) HT 11 KV indoor type VCB Panels of capacity 200/400 amp -5 Nos (iii) Battery charging system including Invertor. (a) Day Shift from 0600 Hours to 1400 Hours (b) Evening shift from 1400 Hrs to 2200 Hrs (c) Night shift from 2200 Hrs to 0600 Hrs
Notes for item No 1.01:-
The Mate Electrician employed shall be ITI qualification having experience to deal with 33/11 KV category of installations. Penalty for absence from installation shall be at double rate quoted per person per day as calculated from the rate quoted.
Duty staff employed by the contractor will attend the faults within duty premises in 33KV/11KV Substation of Garhi Cantt including all outgoing feeders
Minor repair and preventive maintenance required to ensure the serviceability and efficiency of complete Sub Station complex its outgoing feeders including supply of minor spares. Minor spares will be classified as those spares which are costing less than Rs. 1000/- per item/occasion.
In case of major breakdown all T&P and additional manpower required for restoring the power supply within 24 Hrs shall be arranged by the contractor without any extra additional cost. Unit rates also included the conveyance & communication facilities required to complete the job. Material such as insulator, cable, end joints, ACSR shall be measured and paid for separately.
Earthing test register, record of commercial supply breakdown and A printed log sheet shall be maintained for both incoming/outgoing feeders to record voltage / current /PF /Energy consumed/ Temperature of transformers, breakdowns etc. stationary required for the same shall be provided by contractor without any extra cost throughout contract period.
The item rate includes reliever for Sunday holiday and leave as per labour law, EPF,ESI, Bonus, water charges, service tax , insurance, CP & Tools as stated above and no extra payment shall be made on account of above.
The Contractor shall ensure that all Safety Precautions are strictly exercised by the staff employed by him. Adherence to IE Rules and other statuary rules in vogue must also be ensured. The contractor shall be solely responsible for any mis happenings that occurs due to any fault of the employee or due to non-adherence to the electrical safety norms.
The installation shall be always kept clean and no inflammable/corrosive/toxic material shall be stored inside the sub station
The Contractor shall provide the following items to their workman. (a) Uniform in blue colour i.e. trouser and shirt of same cloth i.e. polyester duly stitched with front two pockets written "MES" and GE DEHRADUN" complete as per the size of the staff employed. (b) Industrial leather shoes with shock proof soul, nylon laces complete per the size of the staff employed. (c) Socks cotton blue colour per the size of the staff employed. (d) Shock treatment chart as per IS on min A1 sheet or nearest higher size
M&L attending fault/ breakdown round the clock in HT Over Head line /Breaking UG Cable due to any reason like falling of tree branches, Bird hits, Cracking of Pin/ Disc insulator, breaking Over Head conductor complete including patrolling of LT line, Meggering, removing of fault, replacement of insulator any type, replacement of fuses and restoring the feeder complete all as specified and directed for following areas :-
Ghanghora area feeder from 33/11KV MRS to complete area of Ghanghora (Approximate 17 KM go and back )
Birpur Area feeder from 33/11KV MRS to complete area of Birpur (Approximate 18 KM go and back )
Notes for item NO. 2.00 :-
All T&P required to complete job is included in unit rate.
Unit rates also included the conveyance & communication facilities required to complete the job.
Unit rates also include the mobile phone required for taking shut down etc
The Electrician employed shall be ITI qualification having experience to deal with11 KV category of installations. Penalty for absence from installation shall be at double rate quoted per person per day as calculated from the rate quoted.
The Electrician employed shall be ITI qualification having experience to deal with11 KV category of installations. Penalty for absence from installation shall be at double rate quoted per person per day as calculated from the rate quoted.
M&L for attending fault/ breakdown round the clock in LT Over Head line/under ground cable/ LT Panel due to any reason like falling of tree branches, Bird hits, Cracking of Pin/ Disc insulator, breaking Over Head conductor complete including patrolling of feeder, Meggering, removing of fault, replacement of insulator any type, replacement of LT/ HT fuses and restoring the feeder, complete all as specified and directed.
Birpur Offr colony, 116 Bde, 5/9GR, 4 Kumaoun Chaudhry line 41 MVH, Tigris Line (Birpur feeder)
Milan Chowk Area, Sulva line, Robert Line, 6/8GR, 11 SikhLi, Ghangora Offr Colony, 244 Fd Wksp (Ganghora feeder)
Note for item No 3.00 :- (i) All T&P required to complete job is included in unit rate, all as specified and directed. (ii) Unit rates also include the veh-4 wheel/Two-wheel required to complete the job. (iii) Unit rates also include the mobile phone required for taking shut down etc to complete the job. (iv) The Electrician employed shall be ITI qualification having experience to deal with11 KV category of installations. Penalty for absence from installation shall be at double rate quoted per person per day as calculated from the rate quoted. (v) Duty staff employed by the contractor will attend the faults within duty premises in LT feeder in Ghanghora/ Birpur Area at Dehradun.
Sch 'A' Part -II for Item No. 4.00 to 84
Material and labour for servicing of DG set of 62.5 KVA to 75 KVA 3 phase 50 HZ, Make : Cuminns/ Kirloskar/ Greaves. by cleaning, servicing, oiling and greasing of moving parts, checking the serviceability of self starter, alternator, AVR for proper voltage out put, Batteries voltage & electrolyte be checked & added up to top level, function ability of safety devices, all nut - bolts of Engine and alternator, proper tension of fan belts, check coolant level and if necessary top up.. Ensuring leak proof of all type hose for water , pipe line of fuel and lub oil. Checking of air cleaner element & clean it with dry compressed air (60 psi pressure.). Material and labour for replacement of Air filter elements set, cleaning of oil bath type filters and replacement of oil of oil bath filter, lubricating oil filters element complete set , Fuel filters element, By pass filter, Corrosion resistor plate, fan belts and labour for replacement of lubricating oil , complete as specified and directed.
Notes for item No. 4:
The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The cost of servicing of DG set are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, studs etc and parts mentioned in the item above..
Make of DG set be one of the make mentioned in the item.
Spare parts to be replaced shall be suitable for the same make and model of engine as installed at site and serviced.
Cost of lubricating oil shall be measured and paid separately.
Cost Spare parts to be replaced shall be measured and paid separately under item No. 5 here in after.
Supply only of the following new parts suitable for fuel injection pump assembly repaired under Schedule `A' item No 4 above :- Note :- Rate for fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 4.
Water hose pipe set with clamp for 62.5 KVA of DG set.
Lubricating oil pipe set with coupling for 62.5 KVA capacity of DG set.
Fuel oil pipe set with coupling for 62.5 KVA capacity of DG set.
Oil temperature gauge
Water temperature gauge
Oil pressure gauge 0 to 7 kg/cm2
Hours meter
Ampere meter.0-300A
Shut down valve suitable for 62. 5KVA of DG sets as per existing shape and size.
Disconnecting, and taking out carefully old unserviceable AVR unit and supply, fixing, connecting and testing AVR unit suitable for DG set of 62.5 KVA capacity and testing for regulated voltage of 415 volts complete all as specified and directed.
Supply only lubrication oil SAE-40 ( 20 W- 40 grade) of Make SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL/ CASTROL) as approved by GE.
Disconnecting and taking out the radiator of 63.5 KVA 3 phase capacity of DG set 50 HZ, Make ; Kirloskar and carrying out to work shop, strip opening completer radiator assembly, cleaning of tubes with using de-scaling solution, including soldering / gas welding of leakage of tubes. Cutting the rusted portion of in let or out let tubes including gas welding of new MS water tubes assembling the complete radiator including replacement of gasket, nut bolts, and testing for making it leak proof including oiling/servicing of water cooling assembly, replacing unserviceable parts, re-assembling and fixing the same in position and testing the system complete all as specified and directed.
Note for item No 8:- (i) Repairs/servicing/reassembling and testing of water cooling assembly shall be carried out on actual load.
(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, screws/gaskets/ packing etc.
(iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro up to Work shop/service centre.)
Disconnecting and taking down old unserviceable self starter, 12 Volt DC and dismantling complete for repair, servicing, cleaning, varnishing, oiling, reassembling & testing including replacement of the following parts complete all as specified and directed. :-
(a) Armature – 01 No
(b) Solenoid switch – 01 No.
(c) Field coils – 01 No.
(d) Commutator – 01 No.
(e) Carbon brush – 02 Nos.
(f) Bendex assembly – 01 No
(g)Tension sleeve=01no
(h) gear assembly-01 no
M & L for Cleaning of MS fuel tank of DG sets of various capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 meter and cleaning the tank with kerosene oil , replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 liter by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed.
Dismantling and taking out old unserviceable Dynamo assembly of 62.5 KVA capacity of DG set for repair and replacement of defective parts like as Carbon brush, Bearing No. 6302 and rewinding to armature with suitable gauge of copper wire, sleeve, glass paper and Varnish, soldering to commutator assembly, reassembling & fixing the same in position and testing the dynamo assembly complete all as specified and directed.
Supply & fixing of lead acid battery 12 Volts, 180 AH including 02 duly initial charging of the battery and fixing to its position complete all as specified and directed .
Disconnecting and taking out defective battery lead and supplying, fixing, connecting and testing battery lead (Heavy duty) PVC insulated with multi strand copper conductor single core of size 25 Sqmm for 2 metre length including one side fixed with brass/ copper eye hole lugs clamp and other side fixed with brass battery terminal of heavy duty complete all as specified and directed.
M&L in replacement for cross arms, bracing, supports clamps back plates fabricated from structural steel section such as suitable channel ISMC angle iron and flat iron GI nut, bolt & Washers with welding, cutting, drilling hole etc for insulator bolts clamps in any shape and size including one coat of red oxide and two coats of synthetic enameled paint all complete all as specified and directed.
M&L fixing in replacement and stringing continuous GI wire of 4mm dia on poles/cross arm with GI hooks, bolts, nuts washer etc including stringing and connecting complete all as specified and directed.
M&L in replacement ACSR conductor stringing and fixing on insulator existing sagged ASCR conductor including 22 Guage binding wire line connector, jumper etc of size complete all as specified and directed.
S & F in replacement stay assembly for LT steel tubular poles comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/Sq mm (grade-2 quality) fixed to pole with and including GI clamps bolts, nuts, washers, galvanized steel stay rod 16mm dia 180 cm long bow 400x14mm nuts/bolts, washers all galvanized and two Nos thimble, loop insulator of size 65x90mm vitreous, clearance dia of hole 16mm, stay plate of size 230x230x6mm including necessary excavation and earth work any type strata PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus soil, up to 50 M all as specified and shown in plate No 1 of MES SSR Pt -I, and as directed.
Supplying, transporting, erecting and fixing in replacement Steel tubular swaged poles type 410 SP-31, 9.00 meter long , complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified including painting with two coats of synthetic enameled paint over one coat of red oxide primer and 06 Nos bands/ straps with yellow and black colour ( 30 cm wide each)epoxy heat resistant paint at a distance 30 cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including tarring/Bituminous paint one coat on steel surface embedded in concrete foundation complete all as specified and shown on drawings and directed.
Supplying, transporting , erecting and fixing in replacement steel tubular swaged poles type 410-SP-55 , 11.00 metre long, complete with cast iron base plate , heat resistance finial taper plug, bolts, nuts and screws as specified including painting with two coats of synthetic enameled paint over one coat of red oxide primer and 06 Nos bands/straps with white and red post office colour (30cm wide each) epoxy heat resistant paint at a distance 30cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including tarring/Bituminous paint one coat on steel surface embedded in concrete foundation complete all as specified and directed.
Supply and fixing in replacement insulator pin type porcelain vitreous white, brown or green HT 11000 Volt including 01 galvanized M.S. spindle, two galvanised iron washers and one galvanised. iron nut of size 150mmx150mm complete all as specified and directed.
Supply and fixing in replacement Disc type insulator porcelain vitreous HT 11000 Volt 145mm highx255mm dia ball including G.I. mild steel strip at 38 x 5mm 20mm dia insulator bolts, washers, nuts suitable for working pressure 1.1KV complete all as specified and directed.
Supply and fixing in replacement insulator pin type porcelain vitreous white, brown or green LT 1100 Volt including 01 galvanized M.S. spindle, two galvanised iron washers and one galvanised. iron nut of size 100mmx65mm complete all as specified and directed.
Supply and fixing in replacement shackle type insulator porcelain vitreous LT 11000 Volt 150x150mm including G.I. mild steel strip at 38x5mm 20mm dia insulator bolts, washers, nuts suitable for working pressure 1.1KV complete all as specified and directed.
Dismantling, re-stretching, restringing tensioning and repair to overhead line ACSR conductor any size as required on LT/HT Pole for ACSR conductor with GI guard wire including fixing on insulators and jointing with ACSR conductor with GI line connector, PG clamps suitable for jumper connection etc complete of the following OH line all as specified and directed.
(a) For HT over head line with GI Guard wire
(b) For LT over head line with GI Guard wire from LT pole to pole five line LT over conductor and one guard wire conductor of each span shall be measure as one unit.
(c) For LT over head line with GI Guard wire from LT pole to pole two line LT over conductor and one guard wire conductor of each span shall be measure as one unit.
M&L for Trimming/ prunning of tree branches up to 3 meters below & both sides to obtain clearance all around the LT over head lines / HT over head lines conductor up to 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr in wide and exceeding 1.5 but not exceeding 3.0 mtr depth for foundation of pole and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete all as specified and directed by the Engineer in Charge. Note :- Only punned down sand thickness 18CM shall be measured and paid
Supplying and laying old size bricks, laid flat ie length of brick shall be laid across the cable, common burnt clay building bricks sub class `B' designation 75 complete all as specified and directed and testing on completion complete all as specified and as directed by Engineer in charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV type-1,flat size 300x180x40mm complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) for coping pole including necessary Steel form work and finishing exposed faces of concrete smooth and even with using extra cement complete all as specified and directed.
Disconnecting and taking out unserviceable damaged of any size cable and supplying, laying in replacement, jointing and testing LT underground cable, heavy duty, 1100 Volts, PVC insulated and sheathed, armoured with multi-stranded aluminium conductor cable conforming to latest IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable duly insulated 1.1 KV grade heat shrinkable sleeve including cable gland and lugging etc at both ends all complete all as specified and directed of following sizes. Note : Excavation, earth work, cable sand cushioning & cable protection shall be measured separately under relevant items of this schedule complete all as specified and directed.
(a) 185 Sqmm 3.5 Core
(b) 120 Sqmm 3.5 Core
(c) 95 Sqmm 3.5 Core
(d)70 Sq mm. 3.5 core
(e)50 Sq mm, 3.5core
(f)35 Sq mm, 3.5core
Disconnecting and taking out unserviceable damaged of any size of HT cable and Supplying, laying or fixing, jointing and testing HT underground electric power cable , XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, (conforming to IS-7098 Part-I) , ISI Marked, with aluminium conductor multi stranded , heavy duty ,11000 Volts grade ( earthed ) , laid in trenches/ laid under floor, roads, paths or fixed on walls / on poles/ in ducts etc. complete including cable gland and lugging etc all as specified and directed of following sizes. Note: Excavation and GI Tubing shall be measured and paid separately under respective item of Sch 'A'.
(a) 95 Sqmm 3 core
(b)120 Sqmm 3 core
Supply and fix HT heat shrinkable out door type cable jointing kit for 11 KV grade, XLPE cable of size 95 sqmm 3 core complete all as specified and directed.
All as per srl item No 37 above but of size 180 sqmm 3 core.
All as per srl item No 37 above but of size 240 sqmm 3 core.
M&L for heat shrinkable straight through joints for HT U/G cables11000 volts grade and testing after jointing of the following sizes :-
(a) 95 Sqmm 3 core
(a) 95 Sqmm 3 core
(b)120 Sqmm 3 core
M&L for heat shrinkable straight through joints for LT U/G cables 1100 volts and testing after jointing of the following sizes :-
(a) 35 Sqmm 3 ½ core
(b) 70 Sqmm 3 ½ core
(c) 95 Sqmm 3 ½ core
(d) 185 sq mm 3.5 core
(e) 300 sqmm 3 ½ core
(f) 400 sqmm 3 ½ core
Supply and laying in trenches fixed to poles wall laid in floor GI steel tubing medium grade with fitting GI clamps made out of 50 x6mm flat iron 02 Nos, bolt, nut & washers etc or wooden rubber bushing at the ends of complete all as specified and directed.
(a)100mm bore
(b)80mm bore
(c)50mm bore
(d)40mm bore
Disconnecting and taking down unserviceable GOD & supplying, installing, testing and commissioning of air break switch (GOD)(12 insulator type) HT 11 KV, AC 50C/S, TP Horizontal mounting type, mechanically operated from ground, mounted on 12 insulators 11 KV grade and steel frame, current rating upto 200 Amps complete with fuse mounting, fuse carriers and fuse elements of required capacity fixed the pole structure on channel angle iron cross arm with suitable GI nut bolt & washers etc with suitable size including testing complete and one pad lock 65 mm (Godrej/navtal) including dropant expulsion type fuses with barrels of required capacity to suit load at site complete all as specified and directed.
Disconnecting and taking down unserviceable lightning arrestor supplying, fixing and testing Expulsion type lightning arrestor having rated voltage 11 KV and discharge current 65 KA suitable for 11000 Volt with mounted on MS plate 8 mm thick duly painted with aluminum paint bottom of size of lightning arrester including connection with earth strip connecting device complete all as specified and directed.
M&L servicing of two & four pole, structure complete including replacement of unserviceable jumper, sleeve vice type connector GI PG clamps 'T' connector run through clamps, bolts nuts, washer connecting lugs/thimbles knife contacts applying petroleum jelly to the moving contact as well fixed contacts, tightening all the connection for its smooth functioning complete all as specified and directed. Note :- No extra payment will be made for the spares required to keep the two & four pole structure in satisfactory functioning throughout contract period other than given in schedule.
M&L for preparing old painted surface of the HT four pole structure such as poles, cross arm bracing and supports clamps complete painting of two coats of synthetic enameled paint over a coat of red oxide zinc chrome primer provisioning of marking with alternative white and Red paint strip 30 cm wide including writing pole no with white paint size of letter note less than 100mm from the ground level complete all as specified and directed.
M&L for preparing old painted surface of the two pole structure such as poles, cross arm , bracing and supports clamps complete painting of two coats of synthetic enameled paint over a coat of red oxide zinc chrome primer provisioning of marking with alternative white and Red paint strip 30 cm wide including writing pole no with white paint size of letter note less than 100mm from the ground level complete all as specified and directed.
M&L for preparing old painted surface of the HT single pole structure such as poles, cross arm , bracing and supports clamps complete painting of two coats of synthetic enameled paint over a coat of red oxide zinc chrome primer provisioning of marking with alternative white and Red paint strip 30 cm wide including writing pole no with white paint size of letter note less than 100mm from the ground level complete all as specified and directed.
M&L for preparing old painted surface of the LT single pole structure such as poles, cross arm , bracing and supports clamps complete painting of two coats of synthetic enameled paint over a coat of red oxide zinc chrome primer provisioning of marking with alternative yellow and black paint strip 30 cm wide including writing pole no with white paint size of letter note less than 100mm from the ground level complete all as specified and directed.
Repair to Electrical panel by opening of all burnt unserviceable cable leads any size and taking out of LT XLPE cable from loop by excavation as required including reconnecting of cable leads with bus bar/ MCCBs with proper lugs and nut/bolts etc and panel to be re fix properly on PCC foundation with repair to door hinge / locking arrangement and testing complete all as specified and directed. NOTE: Copper lugs and PCC shall be measured and paid separately.
S&F in replacement of u/s MCCB 500 Amps 50 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
S&F in replacement of u/s MCCB 400 Amps 35 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
S&F in replacement of u/s MCCB 250 Amps 35 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
S&F in replacement of u/s MCCB 200 Amps 35 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
S&F in replacement of u/s MCCB 160 Amps 25 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu complete all as specified and directed.
Supply and fixing in replacement copper crimping lug thimble type of size 400 sqmm.
S&F in replacement copper crimping lug thimble type of size 240 sqmm.
S &F in replacement copper crimping lug thimble type of size 120 sqmm.
S &F in replacement copper crimping lug thimble type of size 70 sqmm.
Dehydration including filtration and cleaning of transformer oil at different locations by stream line method dehydration plant including testing of samples before and after dehydration and filtration. Dielectric strength should not be less than 45 KV at 2.5 mm gap after dehydration all as directed.
Note: (i) Test result before and after filtration to be recorded as per the sample provided by Engr-in-charge.
(ii) The rate quoted is deemed to be inclusive of making necessary connection and the connection to filtration plant from transformer and switch gear oil duly removing the inlet and outlet connections.
(iii) For topping up transformer oil will be measured and paid separately under relevant item of schedule.
M&L for preventive maintenance/repairs to transformer step down 11 KV/0.43 KV out door type of any make and capacity including cleaning the transformers externally thoroughly with lint free cloth, tightening the HT/LT terminal nuts, opening the top cover and replacing the perished gasket of top cover, replacing sight glass, replacing silica gel, replacing the worn out copper alloy nuts and tightening the earth terminals and conducting various tests as stipulated in the particular specification and maintaining relevant documents/records duly signed by JE E/M and Engr-in-charge separately to each book let for equipments/machine on the prescribed printed forms complete all as specified and directed.
Supply and filling for top up of transformer oil in sealed steel container 200 Ltrs capacity conforming to relevant IS 335/1993 as amended having dielectric strength not less than 45 KV for topping in 33/11 KV transformer all as directed. Note: (i) Filling of insulating oil shall be done by on line filtration plant. (ii) Manufacturers test certificate to be produced for claiming payment complete all as specified and directed.
M &L in replacement of defective worn out HT bushing rod (stud) complete set of three made of copper /brass with nuts and washers including threading at both ends for HT bushing of transformer outdoor of various sizes as per site requirement complete all as specified and directed.
Transformer 63KVA to 160 KVA
Transformer 200KVA to 315 KVA
Transformer 400KVA to 500 KVA
S&F in replacement of defective worn out LT bushing rod (stud) complete set of three made of copper /brass with nuts and washers including threading at both ends for LT bushing of transformer outdoor of various sizes as per site requirement complete all as specified and directed.
Transformer 63KVA to 160 KVA
Transformer 200KVA to 315 KVA
Transformer 400KVA to 500 KVA
S&F in replacement of silica gel breather assembly complete with silica gel complete up to 500 KVA transformer all as the sample approval/site requirement complete all as specified and directed.
M&L for preparation of old painted surfaces of transformer by scrubbing out cleaning and painting with one coat of spray paint and one coat primer heat resistant metallic smoke grey paint complete metallic painting including writing MES No/SM No/Srl No on transformer body with black paint for the following capacity transformer complete all as specified and directed.
Transformer 63KVA to 160 KVA
Transformer 200KVA to 315 KVA
Transformer 400KVA to 500 KVA
Disconnecting defective out door/in door transformers of various capacity upto 500 KVA from HT/LT side, taking out complete transformer oil, storing the same in suitable container (to be arranged by the contractor) opening the top cover and lifting the cover.
Transformer 63KVA to 160 KVA
Transformer 200 KVA to 315 KVA
Transformer 400 KVA to 500 KVA
Dismantling and taking down out door transformer from two pole /four pole structure lowering the same carefully by means of chain pulley block /Hydra / mobile crane as per site requirement and all other required T&P and re-installation after repairs complete all as specified and directed.
S & F in replacement of burnt defective HT copper coil with new made of proper size copper wire (super enameled of high quality) matching with existing insulation etc for Transformer 100KVA to 500 KVA.
All as per item No 69 above but LT coil made of cooper wire (Super quality) matching with existing insulation etc for transformer 100KVA to 500 KVA.
M & L in replacement of unserviceable cracked/worn out synthetic rubberized cork gasket sheet 6mm thick for top cover of transformer of following capacity including nut bolt washers etc all as specified and directed.
Transformer 63KVA to 160 KVA
Transformer 200 KVA to 315 KVA
Transformer 400 KVA to 500 KVA
Transportation of each transformer at civil workshop if required for repairs and retransformation of the same back for installation after repairs including loading /unloading complete all as specified & directed.
Supply & fixing in replacement drop out fuse unit insulator within Barrel type fuse suitable for HT 11 KV outdoor installation mounted on steel frame rating up to 200 Amp including taking
M&L for repair to Air break gang operated switch segregation of serviceable and unserviceable spares/parts/components viz post insulator, fixed contact assembly moving contact assembly, flexible metallic strips etc and replacement of unserviceable spares/components assembly and assembling the complete air break switch unit carrying out fresh lubrication using lithium base grease/petroleum jelly, complete all as specified and directed. Note:- New spares/components shall be measured and paid separately as catered here in after.
Supply only in replacement of metallic (brass, alloy) moving contact set single pole including fixing screwed nuts, and washers suitable for air break gang operated switch up to cap.400 Amp 3 pole 11000 volts grade complete all as specified and directed.
Supply only in replacement of metallic (brass, alloy) fixed contact set single pole including fixing screwed nuts, and washers suitable for air break gang operated switch up to cap.400 Amp 3 pole 11000 volts grade complete all as specified and directed.
Supply only in replacement of metallic (brass, alloy) MS jumper set single pole including fixing screwed nuts, and washers suitable for air break gang operated switch up to cap.400 Amp 3 pole 11000 volts grade complete all as specified and directed.
Supply only in replacement post insulator with GI post for holding fixed/moving contact assembly including fixing arrangement suitable for Air break gang operated switch up to400 Amps 11000 volts complete all as specified and directed.
Supply only tinned copper(as in replacement) of flexible metal straps including fixing screws, nuts and washers all as directed suitable for Air break gang operated switch up to 400 Amps 11000 volts complete all as specified and directed.
Supply only (as in replacement) of back connecter plate including fixing screws, nuts and washers all as directed suitable for Air break gang operated switch up to 400 Amps 11000 volts complete all as specified and directed.
Supply only in replacement burnt jumpers with new PVC insulated 11000 volt single core alum conductor cable of suitable PGI clamps nuts and bolts complete after taking down existing jumpers complete all as specified and directed.
S&F in replacement ACB 4 Pole,415 volt, with microprocessor release, adjustable release manual draw type of capacity 630 Amps,65 KA including testing & commissioning complete all as specified and directed.
Supply and fixing bus bar chamber out door pedestal type size 750x 500x 400mm deep factory made front and back open able made of 2.0mm thick CRCA sheet powder coated including 200amp aluminium bus bar , TPN, fixed on insulators and provision of fixing of MCCB 160amps to 250 amps capacity and locking arrangement complete all as specified and directed.
S&F in replacement pole mounted Junction Box of size 250X200X100mm for fixing cable GS-JB-2520 with provision of four Nos aluminium bus bar with hole for incoming and outgoing cable, bus bar of capacity 40 Amp mounted on epoxy insulator with provision of MCB SP 6 Amp 'B' series including all bare conductor of cable duly insulated PVC heat shrinkable sleeve 1.1 KV heavy duty grade cp brass cable glands & lugs for incoming & outgoing connection complete all as specified and directed.
Relaying/Rerouting of old serviceable HT cable obtain from under Sch 'A' items. Note :- Execution, returning filling, removing, snad and bricks works measured and paid separately.
Supra Electrical
M/s SCHOLASTIC ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .