Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-Finance 1 MARTIN BURN COMPOUND SATYA DOCTOR ROAD KHIDDERPORE KOLKATA WEST BENGAL 700023 | MURSHIDABAD | WEST BENGAL | 700023 | L1 | Accepted-Finance Bid satisfies all tender qualification criteria. | |
| 2 | L2₹18.8 L+₹2.9 L (18.0%)Accepted-Finance | L2 | Accepted-Finance Bid satisfies all tender qualification criteria. | |
| 3 | L3₹25.1 L+₹9.1 L (57.0%)Accepted-Finance | L3 | Accepted-Finance Bid satisfies all tender qualification criteria. | |
| 4 | L4₹30.6 L+₹14.6 L (91.5%)Accepted-Finance | L4 | Accepted-Finance Bid satisfies all tender qualification criteria. | |
| 5 | L5₹32.2 L+₹16.2 L (101.8%)Accepted-Finance 16 A PRESS BUILDING MAGAZINE STREET DARUKHAN MAZAGAON MUMBAI MAHARASHTRA 400010 | MUMBAI SUBURBAN | MAHARASHTRA | 400010 | L5 | Accepted-Finance Bid satisfies all tender qualification criteria. |
Tender Value
Refer Docs
Closing Date
8 Aug 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM (SRM)
P O PERUMANOOR CSL COCHIN ERNAKULAM KERALA
Pipeline Renewal job for the vessel MV SWARAJ DWEEP at CKSRU Kolkata
2024_CSL_202628_1
KP1/PIPELINE RENEWAL/ MV Swaraj Dweep/CKSRU
Open Tender
Marine Services
Turn-key
120 days
CKSRU KOLKATA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
10 Oct 2024
29 Jul 2024
9 Aug 2024
29 Jul 2024
8 Aug 2024
29 Jul 2024
29 Jul 2024 - 7 Aug 2024
PIPELINE RENEWAL ** All Material, Pipes, Gaskets, Nuts, and Bolts Under contractor scope. ** All Pipes Galvanizing on schedule pipes under contractor scope. ** All old flanges should be Re-Use
CABIN-413 -- SPRINKLER LINE IS CORRODED AND WASTED FROM BOTTOM.
Renewal of 1" inch Dia Pipe Sch 80 GI
Bulkhead panel Removal and Refit
105 BAGGAGE ROOM 'S TOILET CHAMBER DRAIN LINE CHOKE, SAME TO BE CLEARED. Sch 40 GI Pipe Dia 2"
INSIDE FFA STORE 124 FIRE LINE IS CORRODED AND HOLED. The same is to be renewed with Galvanized Pipe Sch 80 Dia 2.5"
125 G - FRESH WATER SUPPLY LINE CORRODED AND WASTED FROM DECK LEVEL. The same is to be renewed with penetration Galvanized Pipe Sch 80 Dia 0.5".
125- SEWAGE DRAIN LINE FROM DECK LEVEL TO BE RENEWED. The same is to be renewed Galvanized Pipe Sch 40 Dia 5".
126 (A) - FRESH WATER SUPPLY LINE is to be renewed with penetration Galvanized Pipe Sch 80 Dia 0.5".
IN CREW LAUNDARY, WASHBASIN DRAIN LINE CORRODE & HOLED, SAME TO BE RENEWED APPROX. 2" X 1.5 METERS.
21 STBD GAUGE GLASS CORRODED & WASTED; SAME TO BE RENEWED FOR THE HEIGHT OF 3 METERS. GAUGE GLASS TO BE PROVIDED BY CONTRACTOR.
FWD PUMP ROOM HATCH BILGES LINE CORRODED & WASTED.
Renewal of 4" inch Dia Pipe Sch 80 GI
Renewal of 5" inch Dia Pipe Sch 80 GI
SANITARY SEA WATER LINE CORRODED AND WASTED ABOVE FUEL OIL TANK NO. 23. The same is to be renewed with Galvanized Pipe Sch 80 Dia 1". NOTE: CUTTING AND WELDING TO BE CARRIED OUT IN CONFINED SPACE.
Engine room and fwd p/p room sea chest filters damaged, same to be renew. ***Filters Ship Supply
Sea chest covers for all four sea chest filters to fabricate and renew. **All material contractor Supply
DEFECTIVE PIPE LINE IN ENGINE ROOM
Main seawater pump-1 suction pipeline to crop and renew. Old flanges to use.
Renewal of GI Pipe dia=220mm, Sch-40.
Renewal of GI bend
SME L.O.Cooler fresh water inlet pipe to crop and renew. Old flanges to use.
Renewal of GI Pipe dia=140mm, Sch-40.
Renewal of Bend
The seawater line to the domestic fridge compressor corroded. Same to be crop and renew. Old flanges to use.
Renewal of GI Pipe dia=42mm, Sch-40.
Renewal of Bend
STBD Boiler feed pump discharge line corroded. Same to crop and renew. Old flanges to use.
Renewal of GI Pipe dia=42mm, Sch-40.
Renewal of Bend
Fridge condenser seawater inlet pipe to crop and renew.
Renewal of GI Pipe dia=60mm, Sch-40.
Renewal of Bend
Renewal of flanges
Ram door hydraulic pipe to crop and renew. Material : SS, OD=16MM,
Ram door hydraulic pipe to crop and renew. Material : SS, OD=16MM,
Ram door hydraulic pipe to crop and renew. Material : SS, OD=16MM,
Sea water inlet to ECR A/C condenser corroded. Same to crop and renew. Old flanges to use. GI Pipe dia=60mm, Sch-40
Renewal of Bend
The vent pipe of the jacket cooling aux engine corroded. The same is to be cropped and renewed. Old flanges to use. GI Pipe dia=90mm, Sch-40
Renewal of Bend
HT Cooler seawater inlet pipe corroded. The same are to be cropped and renewed. Old flanges to use. GI Pipe dia=170mm, Sch-40
Reducer for above corroded. Same to renew. Old flanges to use. GI Pipe dia=115mm, Sch-40
Renewal of Bend
Sea water inlet to the outboard cooler corroded. Same to crop and renew. Old flanges to use. GI Pipe dia=170mm, Sch-40
Aft pump room tank 43 dirty water pump discharge line corroded. Same to crop and renew. Old flanges to use. GI Pipe dia=65mm, Sch-40
PME intermediate shaft bearing cooling line corroded. Same to crop and renew. Old flanges to use. GI Pipe dia=20mm, Sch-40
Renewal of Bend
Renewal of Inlet pipe, GI Pipe dia=25mm, Sch-40
Renewal of Out let pipe, GI Pipe dia=25mm, Sch-40
Renewal of Out let pipe, GI Pipe dia=25mm, Sch-40
Renewal of Outlet pipe, GI Pipe dia=25mm, Sch-40
The following SME intermediate shaft bearing cooling lines to renew.
Renewal of Inlet pipe, GI Pipe dia=32mm, Sch-40
Renewal of Bend
Renewal of Inlet pipe, GI Pipe dia=32mm, Sch-40
Renewal of Inlet pipe, GI Pipe dia=32mm, Sch-40
Renewal of Out let Pipe,GI Pipe dia=32mm, Sch-40
Renewal of Bend
Ford pump room FW Hydrophore Airline to renew. GI Pipe dia=15mm, Sch-40
Renewal of Bend
Ford pump room FW Hydrophore drain line to renew. GI Pipe dia=50mm, Sch-40
Renewal of Bend
Ford pump room FW Hydrophore inlet line to renew. GI Pipe dia=80mm, Sch-40
Renewal of Bend
Ford pump room FW Hydrophore suction line to renew. GI Pipe dia=65mm, Sch-40
Renewal of Bend
Ford pump room FW Hydrophore suction line to renew. GI Pipe dia=150NB, Sch-40
Renewal of Bend
Ford pump room FW Hydrophore suction line to renew. GI Pipe dia=65NB, Sch-40
Renewal of Bend
HT pump outlet line forward of SME corroded . Same to renew. GI Pipe dia=125NB, Sch-40
Renewal of Bend
HT pump outlet line forward of SME corroded . Same to renew. GI Pipe dia=150NB, Sch-40
Renewal of Bend
Reducer for above corroded. Same to renew. Old flanges to use. GI Pipe dia=100NB, Sch-40
Renewal of Reducer
ECR A/C Cooling sea water line corroded. Same length of to crop and renew. GI Pipe dia=100NB, Sch-40
Renewal of Bend
The forward pump room ballast line corroded . Same to renew. GI Pipe dia=180 OD, Sch-40
Renewal of Bend
Forward pump room ballast line corroded . Same to renew. GI Pipe dia=170mm OD, Sch-40
Forward pump room ballast line corroded . Same to renew. GI Pipe dia=125NB, Sch-40
Hyper mist pipe line to Purifier room(aft of A/E-2) corroded. Same to renew. GI Pipe dia=20NB, Sch-40
Renewal of Bend
Hyper mist pipe line to A/E-5 (Aft of A/E-5) corroded. Same to renew. GI Pipe dia=20NB, Sch-40
Renewal of Bend
Hyper mist pipe line suction from Tank-40C corroded. Same to renew along with pentration GI Pipe dia=65mm OD, Sch-40
Renewal of Bend
Stbd High sea suction line corroded . Same to renew. GI Pipe dia=50NB, Sch-40
Renewal of Bend
Tech pump discharge line corroded. Same to renew. GI Pipe dia=32NB, Sch-40
Renewal of Bend
ECR A/C Cooling sea water above tank 108 line corroded. Same length of to crop and renew. GI Pipe dia=75mm OD, Sch-40
Renewal of Bend
Soil tank inlet line for tank-1 corroded . Same to renew. GI Pipe dia=50NB, Sch-40
Renewal of Bend
Renewal of Tank Penetration
Renewal of ECR AC Pipeline
GI Pipe dia=50NB, Sch-40
GI Pipe dia=75mm OD, Sch-40
Renewal of 50NB Bend (90 Deg)
Renewal of 75mm Bend(90 Deg)
Renewal of Air line for hydrophore pipe GI Pipe dia=20NB, Sch-40
Renewal of Bend
Renewal of Non-veg condenser in and out GI Pipe dia=75mm OD, Sch-40
Renewal of 09deg Bend
Renewal of Main Bilge pump (Flywheel to pump intermediate valve) pipeline GI Pipe dia=40NB, Sch-40
Renewal of HT cooler distance piece pipeline GI Pipe dia=100NB, Sch-40
Renewal of Topping up compressor LT line inlet pipe GI Pipe dia=25NB, Sch-40
Renewal of Sewage line Pipe GI Pipe dia=50NB, Sch-40
Renewal of Forward pump room sea chest vent line corroded. Same to renew. GI Pipe dia=50mm OD, Sch-40
Renewal of Intermediate Shaft cooling water line pipe.
Renewal of GI Pipe dia=40NB, Sch-40
Renewal of GI Pipe dia=20NB, Sch-40
Renewal of Laundry tank pipe dia-70mm, GI Pipe dia=65NB, Sch-40
Renewal of Bend
Renewal of LT cooler inboard sea water outlet pipe GI Pipe dia=220mm, Sch-40
Fridge compressor pipe corroded same to renew, GI Pipe dia=80NB, Sch-40
Renewal of bend
Boiler circulating pump lines corroded same to renew, pipe dia 80mm, Sch-40 GI Pipe dia=80NB, Sch-40
Renewal of Lagging
Renewal of Bilge pump pipeline GI Pipe dia=100NB, Sch-40
Renewal of Hypermist tank suction line pipeline GI Pipe dia=50NB, Sch-40
Renewal of A/C #1 S/W suction pipeline GI Pipe dia=200NB, Sch-40
HT cooler Inboard and outboard sea water inlet & outlet distance piece pipe to be renewed GI Pipe dia=100NB, Sch-40
Renewal of flanges
ECR A/C Cooling sea water line corroded. Same length of to crop and renew. GI Pipe dia=62mm, Sch-40
Renewal of flanges
The laundry pump suction and discharge pipe corroded and wasted same to renew, GI Pipe dia=75mm OD, Sch-40
Renewal of T-Joint
Renewal of flanges
Renewal of H.T cooling line to SME, GI Pipe dia=50NB, Sch-40
KOLKATA ENGINEERING
OM ENGINEERING WORKS
Marinecraft Engineers Pvt. Ltd.
SHM Shipcare
Island Ship Repairers
VOYAGER MARINE SERVICES INDIA PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .