Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 CrAccepted-AOC | ₹41.9 Cr Quoted ₹44.4 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹47.1 CrRejected-AOC | ₹47.1 Cr | L2 | Rejected-AOC Not L1 Bidder |
| 3 | L3₹56.1 CrRejected-AOC K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹56.1 Cr | L3 | Rejected-AOC Not L1 Bidder |
Tender Value
₹40 Cr
EMD Value
₹15 L
Closing Date
3 Feb 2025, 6:00 pmClosed
Chief Engineer Chennai
HQ Chief Engineer Chennai Zone, Island Grounds, Anna Salai, Chennai 600 009
ENGINEERING, PROCUREMENT AND CONSTRUCTION (EPC) FOR PROVISION OF OTM ACCN FOR 02 UNITS (PHASE-II) AT PANGODE MIL STN TRIVANDRUM
2024_MES_682872_1
85178/E8
Open Tender
Civil Works
850 days
Trivandrum
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (Army) Trivandrum
₹15 L
Yes
HQ Chief Engineer Chennai
1 Apr 2025
7 Nov 2024
8 Feb 2025
7 Nov 2024
3 Feb 2025
20 Jan 2025
18 Nov 2024
Amount
Schedule 'A' PART - I (BUILDINGS/ STRUCTURES) - EPC Mode Note : The schedule A Part IA & IB are not pre-priced by MES and the rate indicated as Rs. 0.00 under Column 5 signifies this fact only
Engineering, Procurement & Construction (EPC) of buildings/ structures for 1st Unit as listed in Sch 'A' Part - IA as per GRIHA norms including all internal services as defined in Annexure - I to III complete as detailed in scope of work and other documents of tender, complete all as specified and as directed.
Engineering, Procurement & Construction (EPC) of building/ structures for 2nd Unit as listed in Sch 'A' Part - IB as per GRIHA norms including all internal services as defined in Annexure - I to III complete as detailed in scope of work and other documents of tender, complete all as specified and as directed.
Note : Schedule 'A' Part - II to Part XVI are prepriced by MES, Bidders shall insert their lumpsum amount under column 6 only.
Lumpsum price worked out by the tenderer for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for SITE CLEARANCE AND DEVELOPMENT as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for PROTECTIVE WORKS AND RETAINING WALL as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for ROAD/ PATH/ HARDSTANDING/ CULVERT as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for SECURITY WALL/ COMPOUND WALL/ FENCING & GATE as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for COOLING APPLIANCES as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-XIII
Lumpsum price worked out by the tenderer for AIR CONDITIONER as listed in Schedule ‘A’ Part-XIV
Lumpsum price worked out by the tenderer for MACHANICAL LAUNDRY as listed in Schedule ‘A’ Part-XV
Lumpsum price worked out by the tenderer for DISMANTLING/ DEMOLITION as listed in Schedule ‘A’ Part-XVI
Schedule 'A' PART -XVII (MISCELLANEOUS ITEMS)
SITE CLEARANCE AND DEVELOPMENT
Felling of tree exc. 300cm and n.exc.1000cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50m and clearing site complete all as specified and directed.
Grubbing up tree trunks exc.300cm and n.exc. 1000cm girth including cutting of trunk portion protruding over ground digging out roots filling holes and levelling of ground, stacking of serviceable material and removing of unserviceable material to a distance not exceeding 50m and clearing site, complete all as specified and as directed.
ROAD/ PATH/ HARDSTANDING/ CULVERT
S&F convex mirror 100cm dia traffic mirror in orange colour, unbreakable with nut and bolt, diameter with adjustable fixing bracket including necessary foundation and supports, etc., complete all as specified and directed by Engineer in charge.
Manufacturing, supplying and fixing retro reflective overhead informatory road signage and boards rectangular type, made up of 2mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM D-4956-01 as approved by Engineer-in-charge, letters, borders etc., as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat complete all as specified and as directed.
Notes : The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specifications, and direction of the Engineer-in-Charge. Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment. The rate also shall be deemed to be inclusive of necessary foundation and frame work.
Manufacturing, supplying and fixing retro reflective cautionary/ warning sign boards of equilateral triangular shape having each side of 900mm with support length of 3650mm and made up of 2mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders, etc., as per IRC; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20cm c/c to back support frame of M.S. angle iron of size 25x25x3mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5mm to a vertical post made up to M.S.
Tee section ISMT 50x50x6mm welded with base plate of size 100x100x5mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge Note : Rate quoted shall be deemed to be inclusive of necessary foundation and frame work.
Manufacturing, supplying and fixing retro reflective Mandatory/ Regulatory sign boards of 900mm diametre with support length of 3750mm and made up of 2mm thick luminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type-IV of ASTM-D:4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc., as per IRC : 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20cm c/c to back support frame of MS angle iron of size 25x25x3mm along with theft resistant measures, mounted and fixed with 2 Nos MS angles of size 35x35x5mm to a vertical post made up to MS
Tee section ISMT 50x50x6mm welded with base plate of size 100x100x5mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS -Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc., complete as per drawing, specification and direction of Engineer-in-charge. Note : Rate quoted shall be deemed to be inclusive of necessary foundation and frame work.
SEWAGE DISPOSAL
Provision of coventional LLDPE Septic Tank for 25 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection, including necessary fittings & fixtures, etc., complete all as specified.
Construction of RCC Septic Tank for 100 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, Base slabs, Baffle walls and Roof Slab including beams, etc., with vent shaft, manhole openings with cover, connection including necessary fittings & fixtures, etc., complete with effective depth of 1.50m and overall depth of 3m Conventional type all as shown in drawing No. TD/ST/795 Sheet Nos. 1/2 to 2/2 complete all as specified.
Construction of RCC Septic Tank for 50 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, Base slabs, Baffle walls and Roof Slab including beams etc with vent shaft, manhole openings with cover, connection including necessary fittings & fixtures, etc., complete with effective depth of 1.50m and overall depth of 3m Conventional type all as shown in drawing No. TD/ST/796 Sheet No. 1/1 complete all as specified.
Construction of Soakage Wells of size 1.20m dia x 3.00m deep (effective depth), excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25, interconnecting pipes of RCC complete filled with brick bats all as shown in drawing No. TD-563 Sheet No. 1/1 complete all as specified.
Construction of Soakage Wells of size 1.20m dia x 1.50m deep (effective depth), excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25, interconnecting pipes of RCC complete filled with brick bats all as shown in drawing No. TD-563 Sheet No. 1/1 complete all as specified.
Construction of Soakage Wells of size 1.8m dia x 3.00m deep (effective depth) in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 concrete incl intercepting chamber made of brick masonry in CM RCC cover slab M-25 intercepting pipes of RCC complete filled with brick bats all as shown in drawing No. TD-563 Sheet No. 1/1 complete all as specified.
SECURITY WALL/ COMPOUND WALL/ FENCING & GATE
M&L for PVC chain link fencing using MS angle, 50x6mm FI fillets, 10mm dia straining rod, etc., complete all as specified.
S&F concentrina coil of 610mm diameter punched tape (supporting on MS Angle iron frame and barbed wire all as specified and shown on drg) manufactured using central core of high tensile GI spring steel core wire of 2.6mm dia around which a tape of razer sharp blades (Low carbon GI Stripes) of thickness 0.52mm is machine crimped with following specifications :- (a) Dia of coil (Unstretched) = 610mm (b) No of Circles = 51 turns per coil (c) Wt of each coil with hessian cloth = 8.50 kg +/- 0.5Kg (d) Coverage per coil = 8Rm (e) Dove tail clips shall be grade A as per IS:2062 & hot dip galvanised with 20microns or 290gms/sqm. 5 clips per 2 spiral turns approx 125 clips per coil. (f) The tensile strength of spring steel core wire shall be 1620 N/Sqmm (min) all as per IS:4454 (Part I) with zinc coating of 230gm/Sqm as per IS:2629 (g) Punched tape shall be matt finish with average coating of galvanisation of 18 microns.
Note : (i) MS angle iron frame and barbed wire shall be measured and paid separately. (ii) The concentrina coils shall be tied to barbed wire with 1.2mm GI wire. (iii) Concentrina coil shall be measured along the length of the wall.
EXTERNAL WATER SUPPLY
M&L for cutting the existing 150mm DI pipe and inserting the TEE (150X150X100mm) including necessary threading, union, fittings, joints, etc., complete all as specified and directed.
M&L for cutting the existing 150mm DI pipe and inserting the TEE (150X150X80mm) including necessary threading, union, fittings, joints, etc., complete all as specified and directed.
M&L for cutting the existing 150mm CI pipe and inserting the TEE (150X150X50mm) including necessary threading, union, fittings, etc., complete all as specified and directed.
M&L for centrifugally cast (Spun) Ductile Iron pipe of size 100mm dia bore with socket & spigot end centrifugally, class K-7 conforming to IS: 8329:2000 marked with and including Rubber Gaskets used with Push-on-jointing confirming to IS:5382 in any length laid in trenches with and including all fittings all as specified.
M&L for construction of Valve Chamber 600 x 600 x 600mm depth with PCC 1:4:8 foundation, brick work in cement mortar 1:4 using class B bricks, PCC 1:2:4 coping at the top, plastering 15mm thick in CM 1:4 including MS sheet cover 3mm thick with angle iron frame 50x50x6mm, locking arrengement, etc., complete with painting on steel surface with one coat of red oxide paint over two coats of synthetic enameeled paint, necessary excavation and earth work all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply, installing, testing and commissioning, of 160KVA Unipack Compact Sub-Station (CSS) with non extensible RMU 11kV, consisting of the following :
(A) HT SWITCHGEAR : 11kV 630Amps 21KA for 3 Sec SF6 insulated Non-Extensible Compact switchgear (Type CV) consisting of 1 No Fixed Motorized Loadbreak switch with associated earthswitch for incoming cable and 1 No Fixed Motorized Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMTL + Inst.) protection along with interconnection between HT switchgear and transformer shall be using 1Cx3x95 sqmm Alu unarmorured XLPE cable (Make: ABB) - 1 No Self powered non-communicable O/C & E/F Protection Relay of Ashida Make - ADR141A (50,50N,51,51N) - 1 No CT of Ratio - 40/1A, CL - 5P10, Burden - 2.5VA for Protection - 1Set Voltage Presence Indications for Incoming Healthy Indication - 2Set Fault Passage Indiactor with accessories in LBS - 1No Mechanical ON/OFF Indication - 1No Manometer - 1No Operating Handle - 1No Battery/Battery charger - 12 V DC, 12AH - 1No
(B) TRANSFORMER (IS:1180 (Level - iii) amended update) : 160KVA 11KV/433V DYn11 Cast Resin Copper Wound ONAN Type Transformer with Off load tap links of range +5% to - 5% @2.5% steps. Losses ( As per IS Tol ) NLL-950W and FLL - 3600W, Impedance : 4.5% (With IS Tol.), Class of Insulation - F. Temperature Rise in winding over ambient temp. of 50Deg C - shall be 90 Deg. C. ( Make- Ames Ipex/Eq) - 1No WTI Scanner with Alarm & Triping Contact - 1No Surge Arrestor - 1No (C) LVS PANEL 400AMPS Aluminium BUSBAR (100% FOR PHASE AND 50% FOR NEUTRAL), Current Density - 1 Amp/sqmm
INCOMER FROM TRANSFORMER : 360Amps 433Volts 36KA 4P Fixed Manual Type Molded Case (MCCB) Circuit Breaker with Mircoprocessor based released overcurrent, short circuit fault protection (Make: ABB) - 1No RYB, ON-OFF Indications - 1Set Digital Multifunction Meter of Class 1.0 accuracy with RS485 Port ( Make: Secure/ ABB/ Rishabh/Eq) - 1No Metering CT : 400/5A, 5VA, Class 1.0 Accuracy ( Make : G&M/Newtek/Eq) - 1Set 320A 433V 25KA 4P Fixed Manual Type Molded Case (MCCB) Circuit Breaker with Mircoprocessor based released overcurrent, short circuit fault protection (Make: ABB) -1Nos 160Amps 433Volts 25KA 4P Fixed Manual Type Molded Case (MCCB) Circuit Breaker with Mircoprocessor based released overcurrent, short circuit fault protection (Make: ABB) - 2Nos 100Amps 433Volts 25KA 4P Fixed Manual Type Molded Case (MCCB) Circuit Breaker with Mircoprocessor based released overcurrent, short circuit fault protection (Make: ABB) - 1No (D) APFC Panel with 50KVAR - 1Set (E) OUTDOOR ENCLOSURE : Outdoor type enclosure having construction of Galvanised Sheet Steel of thickness 1.5/2mm with 4mm Baseframe. The Enclosure shall have IP:54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder coated ( colour Light Gray & D.A.Gray ). Each compartment shall be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Seperate switch operated bulket lamp + Hooter shall be provided in Transformer - 1Set
Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 400Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangementS (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm complete all as specified and directed. Panel should be above ground level. The scope of work includes the following:-
Supply, installing, testing and commissioning, factory made and tested LT feeder pillar box (KIOSK), (CPRI type test certified), outdoor type, platform mounted, suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 200 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangements (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm complete all as specified and directed. Panel should be above ground level. The scope of work includes the following :-
Supply, installing, testing and commissioning, factory made and tested LT feeder pillar box (KIOSK) (CPRI type test certified), outdoor type, platform mounted, suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 200Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangements (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm complete all as specified and directed. Panel should be above ground level. The scope of work includes the following :-
Supply, installing, testing and commissioning, factory made and tested LT feeder pillar box (KIOSK), (CPRI type test certified), outdoor type, platform mounted, suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 400 Amps. The panel shall be dust and vermin proof, IP:65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangementS (including provn of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, copper conductor, FRLS cables, IS:694 marked of adequate size but not less than 4 sqmm complete all as specified and directed. Panel should be above ground level. The scope of work includes the following:-
S&F cable route indicator made of 15 x 15 x 6mm thick MS plate welded with 10mm x 30cm long MS rod grouted in PCC block of size 0.2 x 0.2 x 0.3m and writing LT cable complete all as specified and as directed.
S&F FRP pole box of size 168 x 253 x 115mm, thermoplastic, polycabonate, IP-66 complete with 4 pole 32 A connector, Double compression glands-2 Nos, MCB SP 6 Amps mounted with GI clamps of suitable size with nuts and bolts on street light pole all as specified and as directed.
Material and labour for street light bracket made of 40mm GI pipe light grade 1.5m length bent in shape for mounting street light on one end, fixing the bracket on pole with suitable GI clamps, Nus and bolts all as specified and as directed.
S&F SMC terminal box of size 230 x 170 x 105mm (internal diamensions) made of impact resistance plastic & heat resistant materials including MCB SP 6Amps with DIN bar and 4 way terminal block, and fixing the box to street light pole made of 25x 3mm flat iron with clamps, nuts and bolts complete all as specified and directed.
S&F MCCB 4 pole 63 Amps, 415 Volts, 50 Hz, with breaking capacity 25 KA incl addition/ alteration in existing panel to fix MCCB and making incliing and outgoing connections complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised Iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer, etc., of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr complete all as specified in electrical plate No 5 of SSR Part I and connection to earth test point including testing on completion all as specified and as directed.
Note : The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the main earth lead Galvanised Iron wire 4mm dia, by means of nuts, bolts, check nuts and washer, etc., of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr complete all as specified in electrical plate No 5 of SSR Part I and connection to earth test point including testing on completion all as specified and as directed.
Note : The cost of 7.5m long galvanised iron earth wire 4mm dia and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
M&L for filling with riddle earth in trenches including watering and consolidation, spreading, levelling, punning for laying/ cushioning of cable complete all as specified and as directed. Note: Punning thickness shall be measured and paid.
COOLING APPLAINCES
S&F refrigerator, electric driven (single phase) BEE 5 star rated of capacity 195 litres complete all as specified.
S&F refrigerator, electric driven (single phase) BEE rated double door of capacity 310 litres complete all as specified.
S&F Voltage stabilizer of capacity 1 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170Volts to 280Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and surge protection complete all as specified and directed.
S&F Voltage stabilizer of capacity 2 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170Volts to 280Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and surge protection complete all as soecified and as directed.
S&F Voltage stabilizer of capacity 4 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170Volts to 280Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and surge protection complete all as specified and directed .
S&F Voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170Volts to 280Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and surge protection complete all as specified and directed .
MACHANICAL LAUNDRY
Supply, Installation, Testing and Commissioning of the Mechanical Laundry equipments and associated sub-systems including piping work & necessory fabrication in dryning & ironing room, all as specifed, as per latest standard engineering practices and as directed. It shall be suitable for linen like uniform, room furnishing, personal garments, Bed sheets & Pillow Covers, etc,. complete all as specified here-under :-
(A) 02 Nos Heavy duty Washer Extractor with the following features :- (i) Capactiy : 45 Kg or next higher capacity commercially available; (ii) Inbuilt electrical heating coil capacity : not less than 22.5 KW; (iii) Motor capacity : not less than 7.5 HP; (iv) Drum Volume : not less than 450 Ltr; (v) Machine shall be heavy duty, front loading & unloading, High Spin 600RPM or more with Auto reverse & forward rotation; full programmable for washing cycles and shall have a feature of pause and continue the same balance cycle on power failure. (vi) Material of construction : The outer body - SS 304/ powder coated MS sheet; inner and outer Basket/drum : Stainless Steel 304. (vii) Display : Microprocessor/ PLC based front display complete with water level indicator, temperature, function & timer in digital format. (viii) Control : Microprocessor/ PLC based control, Variable frequency drive (ix) Door : Front door shall have toughened glass window; manual and auto door closing mechanism sothat It shall remain closed during operation; (x) Additional features : It shall take the solvent/chemical as and when required automatically from 4-5 dispensors, It shall be Self-lubricating, Soft Mount, Suspended, Self-aligned machine; Emergency stop button & Safety limit switches. (B) 02 Nos of Tumber Dryer with the following features :- (i) Capactiy : not less than 60 Kg; (ii) Inbuilt electrical heating coil capacity : not less than 27KW; (iii) Drive Motor/Exhaust motor capacity : not less than 2 HP Each; (iv) Basket Volume : not less than 1227 Ltr capacity; (v) Machine shall be heavy duty, front loading & unloading, full programmable for drying cycles and shall have a feature of pause and continue the same balance cyle on power failure.
The drier shall be Automatic-cooling, Auto-timed, Auto forward&reversible rotation, Auto digital temperature control. (vi) Material of construction : the outer body - SS 304/ powder coated MS sheet; inner and outer Basket/drum - Stainless Steel 304. (vii) Display : Microprocessor/ PLC based front display complete with water level indicator, temperature, function & timer in digital format. (viii) Control : Microprocessor/ PLC based control, Variable frequency drive for dual motors; (ix) Door : Front door shall have toughened glass window; manual and auto door closing mechanism sothat It shall remain closed during operation; (x) Suction Blower : Heavy duty Centrifugal Suction Blower and dynamically balanced; (xi) Insulation : Rockwool/Glass wool duly packed on all sides & front of the drier to minimize the heat loss & saves energy; (xii) Lint Screen : Self cleaning lint screen of SS-304. Facility of cleaning should be through front door. (xiii) Additional features : It shall be Self-lubricating, Soft Mount, Suspended, Self-aligned machine; Emergency stop button & Safety limit switches; Spray Nozzle to inject chemical/ softener. (C) 02 Nos vacuum ironing table with the following features :- (i) Table Top Size : 1300mm X 800mm with Adjustable height; (ii) Table top : SS/GI/MS powder coated sheet of suitable thickness padding with heat resistant material like Silicon foam and heat proof cloth etc.; Perforated flat top padded with high porosity; (iii) Main Body : Made of SS/GI/MS powder coated sheet/plates
(iv) Blower : Heavy duty Powerful suction through Centrifugal blower of minimum 0.5HP Motor activated by spring loaded full length foot pedal working in combination with heavy duty micro switch (v) Heater : In-built Thermostatically controlled stainless steel heater; (vi) Electric Steam : Die cast sole plate, Teflon shoe and thermostatically controlled; Iron heating element with moisture trap, Rubberized handle; (vii) Accessories like trays, side iron stand etc standand suction and chimney complete and connecting up to the steam pipe. (D) 02 Nos Flat bed press table with the following features:- (i) Steam heated, Auto-timed, Auto-temperature controlled, Double Switch operation, Built-in Suction Blower, Pneumatically controlled; (ii) Head & Bed : Polished Stainless steel/High quality steel with Teflon coated/Nickel plated; Head & Bed Size - Minimum 11380X700mm; (iii) Main Body : Made of Mild Steel sheets of 1.5 mm thickness, Welded structure and finished with powder coating (iv) Blower : Heavy duty Suction Blower with powerful suction (v) Safety : Emergency Stop of the machine with emergency switch. Automatic stopping of the machine for Finger guard for operator safety; (vi) Control : Push Button for raising and lowering of the head pneumatically; (vii) Temperature : Digital temperature controller (viii) Suction and chimney complete and connecting up to the steam pipe. (E) 01 No fully automatic Electrical Staem Generator for continous ironing with the following features :- (i) Automatic Electrical Staem Generator shall be compact & poratable in size; It shall produce almost 100% dry steam;
Suitable to with-stand at high operating pressure(3-4bar); with error detection, auto cut-off, Microprocessor/ PLC based with high temperature cut-off. One touch operational panel; (ii) Automatic safety feature in case of pressure exceeding the set pressure to cut off the steam generation; min 5-7 standard safety mechanisms with alarm system., (iii) Detachable SS Heating element : Capacity of heating coil 6 KW minimum, protected by thermostats and water level controller; (iv) Steam output : 10 Kg / hr minimum; (v) Operating Pressure : 3.5 Bar approx.; (vi) Suitable for No. of tables : 2 Nos (vii) Grade : Non-IBR Grade; (viii) The Steam Generator shall be provided with feed water tank of suitable capacity, high pressure pump and water softner plant.The softner plant shall have the capacity to bring down the hardness up to 5 ppm. (F) Air Compressor with the following features :- (i) The air compressor of Kirloskar/Elgi/Ingersolrand make shall be multistage stage, fully automatic suitable for delivering dry compressed air at pressure compatible to Ironer. (ii) Drive : Belt driven with pulleys, belts and belt guard. (iii) Motor : 2-3 HP capacity (Kirloskar/Siemens/NGEF/Crompton Greaves make) (G) Water, Steam and Air Piping work incuding all fittings including valves, tees, elbows, reducers, union, flanges, rubber gaskets, washer etc. as required for making all the laundary equipments fully functional is to be done as follows :- (i) Water pipes & fittings : GI Medium grade, sizes as required;
(M) One number of SHELF TROLLEY (for finished linen) : The linen trolley shall be of SS, with SS tubes, bars, and foldable front, fitted with at least 4 Nos. SS shelves (with 2-shelves removable), base frame shall be supported on swiveling wheels. Capacity 70 Kg (N) One number of MOBILE TABLE : Folding table designed for carrying rolling and folding of linen in the laundry with MS frame and 01 bottom shelf for storage, Complete with heavy-duty ball bearing for swiveling wheels, of polished Stainless steel. Table top size 1200mm x 750mm (O) One number of SHELF FOR FINISHED GOODS With 4 shelves; Made of Mild Steel, Finished with Stoving paints; Size : 1200mmx460mmx180mm Make of Laundry Equipments : IFB-Ramsons, STEFAB, Lucky Engineering, Bucato
S&F 5000 ltrs capacity PVC stoarge water tank, hoisted and fixed in position, double layered and making necessary inlet and outlet connections complete all as specified and as directed.
DISMANTLING/ DEMOLITION
Dismantling any type of Aluminium joinery works like doors, windows, ventilators, partitions etc including all accessories and fixtures complete all as specified and directed.
Dismantling sub main wiring 3 runs 4 sqmm copper conductor including PVC conduit/ Casing & Capping complete.
Dismantling and taking down unserviceable DBs, MCBs.
Dismantling unserviceable LT UG Cable of sizes upto 4 core x 16 Sq mm.
Dismantling unserviceable LT UG Cable of sizes upto 2 core x 16 Sq mm.
S.N. Constructions (BID ID -3220293)
SOOD ASSOCIATES PVT LTD (BID ID -3225055)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 0.32 MB
Tenderdocument.pdf
Tender Documents • 4.21 MB
Tenderdocument_2.pdf
Tender Documents • 16.70 MB
Download all tender documents and submit your bid