Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER, HENCE ACCEPTED | |
| 2 | L2₹45.4 L+₹3.1 L (7.32%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 3 | L3₹46.1 L+₹3.8 L (8.93%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 4 | L4₹46.5 L+₹4.2 L (9.96%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 5 | L5₹47.1 L+₹4.8 L (11.4%)Rejected-Finance H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | L5 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
25 Feb 2025, 6:00 pmClosed
GARRISON ENGINEER
DADWARA KOTA RAJASTHAN 324002
COMPREHENSIVE MAINTENANCE OF STAND BY DG SETS AND SUMMER APPLIANCES UNDER GE KOTA AT MIL STN KOTA
2025_MES_696796_1
8914E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
MIL STN KOTA
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
Yes
GE Kota
₹84,000
Yes
12 Mar 2025
6 Feb 2025
3 Mar 2025
6 Feb 2025
25 Feb 2025
20 Feb 2025
Amount
REPAIR/ MAINTENANCE TO SUMMER APPLIANCES
M & L for taking down & refixing including transportation of window type AC upto 2 Ton capacity from site to civil workshop for repair to corroded body by replacing with 22 SWG MS sheet for side/top and 3mm thick MS plate in bottom of AC & including renewal of unserviceable spares and painting with anti corrosive paint of existing colour over and including a coat of suitable primer and return to MES store yard complete all as specified and directed.
M & L for taking down & refixing including transportation of split type AC indoor/outdoor unit upto 2 Ton capacity from site to civil/local workshop for repair to corroded body by replacing with 22 SWG MS sheet for side/top and bottom of AC & including renewal of unserviceable spares and painting with anti corrosive paint of existing colour over and including a coat of suitable primer and return to MES store yard complete all as specified and directed.
Attending complaints as on required of any nature for defective A/C of various capacity and make split /window type and rectification of defects & including necessary dismantling, taking down if required and taking out for repairing and refixing at site, replacing spares as required (spares parts shall be measured and paid separately), however small pieces of wire terminals, soldering/crimping required at site for proper functioning of the equipment shall deemed to be included in the quoted rate under this item complete all as specified and directed. Note : All spare parts for renewal/ fixing shall be measured and paid separately as supply only or supply & fixing under appropriate items of BOQ.
Supply only in renewal of starting capacitor 100/120 MFD suitable for window/split type AC complete all as specified and directed.
Supply only in renewal of running capacitor MFD/45+2.5 MFD/ 50+4.5 MFD / 60+6 MFD suitable for window/split type AC complete all as specified and directed.
Supply only in renewal of running capacitor 2.5/3/4/6 MFD for fan motor of window type/Split AC complete all as specified and directed.
Supply only in renewal of fan motor 1/5 HP long shaft suitable for window type AC of any capacity, as per sample complete all as specified and directed. MAKE: Universal / Sarada / Tibcon /Keltron
Supply only in renewal of fan motor 1/5 HP suitable for out door unit of split type AC 1.5 / 2.0 Ton capacity as per sample complete all as specified and directed. Make: Universal/Sarada/Tibcon/Keltron /American Universal/GE Motors.
Supply only in renewal of fan blade suitable for out door unit of split type AC 1.5/2.0 Ton capacity complete all as specified and directed. Make: Universal/Sarada/Tibcon/Keltron /American Universal/GE Motors.
Supply only in renewal of starting relay pin type for window / split type ACs as per existing specification complete all as specified and directed. Make - Renutral/ Indfos/ Annapurna or equivalent as approved by GE.
Supply only in renewal of printed circuit board (PCB) suitable for split type AC 1.5/2.0 Ton capacity of existing specification and make complete all as specified and directed. Make : Carrier/Amtrex/Fedder Lloyed/LG/Voltas/Bluestar or as per sample.
Supply only in renewal of temperature digital display sensor suitable for split type AC 1.5/2.0 Ton capacity of existing specification and make complete all as specified and directed. Make : Carrier/Amtrex/Fedder Lloyed/LG/Voltas/Bluestar or as per sample.
Supply and fixing in renewal of remote for A/C split type 1.5/2.0 Ton capacity of existing specification and make complete all as specified and directed. Make : Carrier/Amtrex/Fedder Lloyed/LG/Voltas/Bluestar or as per sample.
Dismantling the unserviceable/damaged insulation and supply and fix nitrile rubber insulation of size 7/8" for suction and liquid refrigerant line for split type AC complete all as directed. Make-A-flex,Totaline.
Supply and fixing in renewal of copper tube 1/4" for window ACs of any capacity complete all as specified and directed. Make - Totaline/Carrier.
Supply and fixing in renewal of copper tube 1/2" complete all as specified and directed. Make - Totaline/Carrier.
Supply only in renewal of condensing coil with copper tube and aluminium fins of capacity 1.5/2.00 TR suitable for split AC complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE.
Supply only in renewal of cooling coil with copper tube for indoor unit of split AC capacity 1.5/2.00 TR complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE.
Supply and fixing in renewal of fiber body suitable for indoor unit of split AC 1.5/2.0 TR complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE.
Supply and fixing in renewal of factory made stand for outer unit of split AC as per existing specification and make complete all as directed.
M&L for electrically disconnecting of outdoor unit of split AC & including taking out from wall / stand after pumping down gas, cleaning/washing of chocked condensing fins and tubes with water and solvent materials by using mechinical pressure after cleaning and servicing refixing of unit, mechanically leak testing including filling of nitrogen gas for pressure testing, finding leak, vacuumising the gas and bracing of leaked copper pipes and filling the suitable refrigerant gas after complete testing, connecting the cables and testing for functioning complete all as specified and directed.
M&L for electrically disconnecting of window type AC and taking out from wall, cleaning /washing of choked condensing fins, evaporator coil and tubes with water and solvent materials by using mechinical pressure, renewal of unserviceable air filter after cleaning and servicing refixing the window AC, mechanically leak testing, including filling of nitrogen gas for pressure testing, finding leak, vacuumising the gas and bracing of leaked copper pipes and filling the suitable refrigerant gas after complete testing, connecting the cables and testing for functioning complete all as specified and directed.
Taking down unserviceable hermatically sealed compressor unit of window/split type ACs of 1.5/2.0 TR capacity and replace with new sealed compressor unit in exchange of the existing unserviceable sealed compressor unit with and including initial charging of gas and oil complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas.
Taking down the existing split type AC of any size & including all accessories and closing the opening of wall with brick/stone masonary work in cement mortar 1:4 and plastering with cement 1:4 including white wash /distempering to match with surrounding & making good the disturbed surfaces to match with existing surface complete all as specified and directed.
Fixing only already removed window/split type AC & including all accessories, making suitable size opening in existing wall as suitable for fixing of AC, including making good the disturbed surfaces to match with existing surface complete all as specified and directed.
Supply and filling refrigerant gas R-22/R- 32/R-410/R-134/R-600 for charging of gas in compressors of existing AC's/Refrigerator/water cooler/Deep freezer complete all as directed. Note ;- (i) Empty /filled cylinder shall be responsability of contractor and he shall be liable for all risk against same deemed to be included in the quoted rate. (ii) Empty gas Cylinders shall be returned to contractor after use.
M & L for repairs to voltage stabilizer of any make/model & including rewinding of main transformer, renewal of sensing transformer, connector, up to 30 Amps power relay and 3 core multistranded PVC insulated flexible copper conductor cable, voltage stabilizer of capacity upto 5 KVA complete all as specified and directed.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 4 Sqmm LT, 1100 volts grade, drawn through and including 20 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor and including taking down old unserviceable wiring complete all as specified & as directed. Note :- Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit.
S&F in renewal of single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, complete with & including one SP, MCB of 32 Amps, 'C' curve complete all as specified and directed.
Notes applicable for all above items :- The contractor is required to carry out onsite (at the place of installation itself) repair of the summer appliances based on day to day requirement of MES during the currency of this contract. Therefore, while quoting the rates contractors should keep this factor in mind as the quoted rates shall deemed to be inclusive of the factor of onsite repair of various summer appliances.
COMPREHENSIVE MAINTENANCE OF STAND BY DG SETS UNDER GE KOTA
Material and labour for servicing/overhauling and 'B' checks comprising of the following for generator lubrication system of under mentioned DG set engine and alternator & AC Generator: - (i) M&L for replacement of engine oil of 15W 40 conforming to CK 4 APL Category. (ii) M&L for replacement of lubricating oil filter elements (iii) M&L for renewal of super lub oil by pass filter elements (iv) M&L for cleaning/change crank case breather (v) M&L for checking of aneroid oil & cooling system. (b) Fuel System : M&L for renewal of fuel filter elements, oil change breather, throttle linkage, Air piping (c) Cooling System : M&L for renewal of coolant in radiator, check heat exchanger, nuts/bolts, adjust injectors and valves, M&L for renewal of tappet cover gasket. (d) AC Generator : Check of winding condition, oiling and greasing of bearings, tuning of exciters, rotating AVR function. Renewal of unserviceable bushes & including assembling and testing complete all as directed. Note : (i) The servicing/overhauling & 'B' checks of DG Set shall be carried out through the original equipment manufacturer's authorised dealers or their Auth service centers only. (ii) Cost of Engine oil, all type of filters i.e. fuel filter, bypass filter, oil filter, coolant, breather, air pipe, tappet cover gasket to be included in the quoted rate.
500 KVA Capacity Make : Engine : CROMPTON GREAVES Alternator : CROMPTON GREAVES
250 KVA Capacity Make : Engine : CROMPTON GREAVES Alternator : CROMPTON GREAVES
180 KVA Capacity Make : Engine : KIRLOSKAR Alternator : Jyothi
160 KVA Capacity Make : Engine : Ashok Layland/Kirloskar Alternator : Kirloskar/Jyothi
125 KVA Capacity Make : Engine : Kirloskar Alternator : Jyothi
40 KVA to 82.5 KVA Capacity Make : Engine : Kirloskar Alternator : Jyothi
5 KVA to 25 KVA Capacity Make : Engine : Ashok Leyland/Kirloskar Alternator : Kirloskar/Jyothi
M & L for replacement of coolant additive concentrator confirming to CK 4 API category complete all as specified and directed.
Supply & fixing in renewal of water hose pipe of DG sets of capacities 500/ 250/ 180/ 160/ 125 KVA, complete all as specified and directed.
~ditto~ all as per item No 33.00 (here-in-before) but for DG sets of capacity up to 75 KVA.
Supply & fixing in renewal of flexible fuel pipe of DG sets of 75 to 500 KVA capacity, complete all as specified and directed.
Supply & fixing in renewal of flexible fuel pipe of DG sets upto 75 KVA capacity, complete all as specified and directed.
M&L for painting the DG Set and DG Set panel by thoroughly cleaning with CTC etc & including preparing the surface and applying one coat of synthetic enamel paint of approved shade by spray painting for DG Sets and DG Set Panels & including writing the capacity & make of DG Set, with white paint complete all as specified and directed for the following capacities of DG sets: -
5 KVA to 20 KVA DG Sets
25 KVA to 50 KVA DG Sets
75 KVA to 180 KVA DG Sets
Supply & fixing in renewal of battery charging alternator belt complete all as specified and directed and suitable for followling capacities of DG sets: -
DG Set 125 KVA to 500 KVA
DG Set 25 KVA to 50 KVA
DG Set 5 KVA to 20 KVA
Supply & fixing in renewal of battery lead set, PVC insulated multisranded copper conductor of size 70sqmm and 1.25 mtr long each duly fixed with brass clamps, copper lugs complete all as specified and directed and suitable for followling capacities of DG sets: -
DG Set 125 KVA to 500 KVA
DG Set 25 KVA to 50 KVA
DG Set 5 KVA to 20 KVA
S&F in renewal of water temperature gauge including sensor and cable complete all as specified and directed.
Dismantling of radiator, taking it to work shop for overhauling & cleaning, descaling with acid, removal of leakage, welding brazing & refixing it duly repaired etc complete all as specified and directed for followling capacities of DG sets: -
DG Set 160 KVA to 500 KVA
DG Set 45 KVA to 125 KVA
DG Set upto 45 KVA
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including writing of tank capacity, Date of cleaning and next due date for tank cleaning for the following capacities of DG Sets: -
DG Set 125 KVA to 500 KVA
DG Set 40 KVA to 75 KVA
DG Set 5 KVA to 25 KVA
S&F in renewal of water pump assembly of suitable capacity complete all as specified and directed for the following DG sets: -
125 KVA to 500 KVA
upto 75 KVA
M &L for repair / overhauling of self starter & including renewal of carbon brushes, bearing, bushes, rewinding of armature and field etc. and warnishing, complete all as specified and directed for the following capacity: -
DG Set 250 KVA to 500 KVA
DG Set 125 KVA to 180 KVA
DG Set 40 KVA to 75 KVA
DG Set 5 KVA to 25 KVA
M & L for repair the fuel injection pump (FIP) & injectors from DG set cap 7.5 KVA to 62.5 KVA and carry out servicing and calibration including renewal of injectors nozzles etc., and refitting the same for smooth and efficient functioning complete all as directed.
M & L for repair the fuel injection pump (FIP) & injectors from DG set cap 75 KVA to 250 KVA and carry out servicing and calibration including renewal of injectors nozzles etc., and refitting the same for smooth and efficient functioning complete all as directed.
M&L for tappet setting, including renewal of gaskets, springs etc complete all as specified and directed.
DG Set 125 KVA to 500 KVA
DG Set 5 KVA to 75 KVA
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth strip of 25x4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 50 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI earth strip of 25x4 mm size for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old unserviceable earthing complete all as specified and directed. (Earth lead strip and GI protection pipe beyond 7.50 m shall be measured and paid separately).
Supply & fixed in renewal of four pole MCCB, 63 Amp, 16 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
Supply & fixed in renewal of four pole MCCB, 100 Amp, 16 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
Supply & fixed in renewal of four pole MCCB, 160 Amp, 36 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
Supply & fixed in renewal of four pole MCCB, 200 Amp, 36 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
Supply & fixed in renewal of four pole MCCB, 250 Amp, 36 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
S & F and connecting in renewal of 180 AH sealed lead acid battery 12 Volt into DG set with all necessary connections, complete all as specified and directed.
S & F and connecting in renewal of 150 AH sealed lead acid battery 12 Volt into DG set with all necessary connections, complete all as specified and directed.
S & F and connecting in renewal of 100/110 AH sealed lead acid battery 12 Volt into DG set with all necessary connections, complete all as specified and directed.
S & F and connecting in renewal of 80 AH sealed lead acid battery 12 Volt into DG set with all necessary connections, complete all as specified and directed.
S&F four pole onload change over switch, 415 V, 200 amp including disconnecting and taking out unserviceable one, complete all as specified and directed.
S&F four pole onload change over switch, 415 V, 100/125 amp including disconnecting and taking out unserviceable one, complete all as specified and directed.
S&F four pole onload change over switch, 415 V, 63 amp including disconnecting and taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 63 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 100/125 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 150 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 200/250 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 400 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
Material and labour for renewal of defective DG set digital controller of DG set capacity 15 KVA to 500 KVA as per manufacturer, complete all as specified and directed.
Supply, Installation, testing and commissioning in renewal of retrofit emission control device for 180 KVA diesel generator of existing Make/vintage complete all as specified and directed.
Supply, Installation, testing and commissioning in renewal of retrofit emission control device for 125 KVA diesel generator of existing Make/vintage complete all as specified and directed.
Supply, Installation, testing and commissioning in renewal of retrofit emission control device for 50 KVA diesel generator of existing Make/vintage complete all as specified and directed.
Supply, Installation, testing and commissioning in renewal of retrofit emission control device for 45 KVA diesel generator of existing Make/vintage complete all as specified and directed.
Supply, Installation, testing and commissioning in renewal of retrofit emission control device for 40 KVA diesel generator of existing Make/vintage complete all as specified and directed. Note :- Technical specification and term & conditions as applicable for item Nos. 67 to 71 of this BOQ here-in-after. Application :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine (a) Min Particular Matter Reduction 85% (b) Min Carbon Monoxide Reduction 90% (c) Min Hydrocarbon Reduction 90%
Technical specification and term & conditions for Srl Item No 71 (here-in-before) :- Technology/ Type :- ESP (Electrostatic Precipitator) Wet Scrubbing, Deisel Oxides Catalyst (a) Guaranteed specified Particulate matter (PM2.5) (b) Carbon Monoxide, Hydroxide, reduction efficiency. (c) Retrofit device is to be installed in the retrofit device. (d) No soot is to be collected in the retrofit device. (e) The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap. (f) Maximum back prescribed load by DG OEMN (as per the capacity of the DG set) should be under limit and display panel to be provided for back pressure and exhaust temperature limit. TEST REPORT Certification:- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit, Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide pollution Control Series PCLS/12/2021-22. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt of India, recognized/ approved test agencies/laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar). Note : It is mandatory to upload the type approval certificate for suitable KVA RATING (ENGINE FAMILY) with registration number & date (from one of the CPCB recognized approved labs) in Cover-1 bid alongwith the tender documents. If the contractor fails to upload the same in cover-1, the bid will be rejected at the Cover-1 stage, and the financial bid will not be opened. The type approval certificate must be applicable as per the DG set manufacturing year, whether CPCB 1 or CPCB 2.
M & L for maintenance servicing and complete checking of automatic main failure (AMF) panel of any capacity & including replacement of worn out parts, copper cables, relay of suitable range, toggle switches, indicator & repair of Ammeter, Voltmeter & including testing complete all as specified and directed by OEM & Engineer-in-Charge. Note :- Cost of spare parts shall be measured and paid separately under relevant item of this BOQ here-in-after.
Supply only in renewal of following spare parts of existing make for automatic main failure (AMF) panel of any capacity : - CT's of range 62.5 KVA to 400 KVA
Relay of range 62.5 KVA to 400 KVA
Digital Voltmeter/Ammeter
Voltage monitoring relay (digital type)
Delay timer
LED indicator (R Y B)
Toggle switch
Dismantling of unserviceable self starter of capacity 24 volts from engine and S&F new one in existing position complete all as specified and directed.
Dismantling of unserviceable self starter of capacity 12 volts from engine and S&F new one in existing position complete all as specified and directed.
Dismantling of unserviceable Dynamo of capacity 12 volts from engine Supply and fix new one in existing position complete all as specified and directed.
Dismantling of unserviceable Dynamo of capacity 24 volts from engine Supply and fix new one in existing position complete all as specified and directed.
S&F in renewal of automatic voltage regulator (AVR) for DG set of capacity 180 to 500 KVA, complete all as specified and directed.
S&F in renewal of automatic voltage regulator (AVR) for DG set of capacity 62.5 to 160 KVA, complete all as specified and directed.
Supply only distilled water in and including PVC containers/bottles of 5 litre each, complete all as specified and directed.
S & F in renewal of fuel indication transparent plastic tube of any size as per existing complete all as directed.
M & L in renewal of broken acoustic enclosure door hinges with stainless steel hinges complete with nut, bolts etc as per site requirement of any type, cap & make as per existing complete all as directed.
M & L in renewal of brass battery terminal suitable for lead acid battery 12 Volt 40 AH to 12 Volt 180 AH complete all as directed.
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 2.0 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 200 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x250 mm, including connection with LT cable with appropriate lugs, complete all as specified and directed.
Labour only for attending day to day break down of DG Set of any size and capacity including complete inspection of DG set, first hand repairs such as tightening of nut bolts, greasing, checking/replacing of battery terminals, levelling of distilled water, cleaning of DG set with vacuum cleaner complete all as directed. Notes :- (i) The maintenance cost of DG set shall be deemed to comprises of cost of labour employed for the purpose, T & P used and other petty items such as cotton waste, kerosene oil, grease, nut, bolts etc. (ii) Non attending the complaint within 8 Hrs @ Rs. 2000/- per day shall be recovered from the contractor. (iii) Keep the complaints pending after one day @ Rs. 4000/- per day shall be recovered from the contractor. (iv) The complaint shall be generated by telephonically/Verbally by concern JE E/M or Engineer-in-Charge. (v) Spares shall be measured and paid separately. (vi) Servicing shall be carried out by the authorised dealer of Manufacturer's i.e. OEM.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removing excavated material (soil) n exc. 50m distance and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
M&L dry clean river sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. (Depth of sand shall be measured after punning).
M&L for pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), class 10, laid dry and flat adjoining each other over sand cushion in trenches as protection to UG cable, complete all as specified and directed.
Supplying, laying, jointing, testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade (ISI marked), laid in trenches / ducts / encased in GI pipe / fixed to pole/wall with necessary angle iron support, clamp, nut , bolts etc and including taking down of old unserviceable existing UG cables complete all as specified and directed for following cross sectional areas of cables :- Notes for Srl item Nos. 91 & 91.10 :- (i) Excavation, earth work, sand cushioning, cable protection cover & GI pipes shall be measured and paid for separately under respective items of BOQ. (ii) Rate deemed to be inclusive of connecting up with control gear including cable glands and cable lugs. Cross Sectional area of cable 50 Sqmm 3.5 core
Cross Sectional area of cable 25 Sqmm 4 core
S&F in renewal of automatic battery charger 12 Volt, DC, 10 Amps suitable for 5 KVA to 160 KVA DG set batteries with complete wiring connection & including suitable size of 2 core service cable for supply complete all as specified and dircted.
S&F in renewal of automatic battery charger 24 Volt, DC, 10 Amps suitable for 180 KVA to 500 KVA DG set batteries with complete wiring connection & including suitable size of 2 core service cable for supply complete all as specified and dircted.
Ganesh Contruction (BID ID -3248970)
L P Singh and Co. (BID ID -3248911)
TARKESHWAR DASS CONSTRUCTION COMPANY (BID ID -3247119)
Aditya Enterprises (BID ID -3248852)
K B Enterprises (BID ID -3247811)
M/s Prem Associates (BID ID -3244661)
SINGH ENTERPRISES (BID ID -3247939)
Pioneer Enterprises (BID ID -3248483)
B B BUILDERS (BID ID -3248075)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .