Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 CrAccepted-AOC | ₹8.5 Cr Quoted ₹8.6 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹8.6 Cr+₹4.9 L (0.57%)Rejected-Finance 583 URBAN ESTATE II HISAR 125005 | HISAR | HISAR | HARYANA | 125005 | ₹8.6 Cr+₹4.9 L (0.57%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹9.3 Cr+₹68.4 L (7.98%)Rejected-Finance | ₹9.3 Cr+₹68.4 L (7.98%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹9.4 Cr+₹83.7 L (9.77%)Rejected-Finance MIG 76 DR NO 39 33 146 2 3 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530018 | ₹9.4 Cr+₹83.7 L (9.77%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹9.5 Cr+₹91.2 L (10.6%)Rejected-Finance | ₹9.5 Cr+₹91.2 L (10.6%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹8.7 Cr
EMD Value
₹7.6 L
Closing Date
31 Aug 2022, 6:00 pmClosed
CHIEF ENGINEER NAVY VISAKHAPATNAM
CHIEF ENGINEER NAVY STATION ROAD VISAKHAPATNAM
DEMOLITION RECONSTRUCTION OF STORAGE ACCOMMODATION FOR FURNITURE UNDER GE ND VISAKHAPATNAM
2022_MES_521842_1
85404
Open Tender
Civil Works
Lump-sum
365 days
GARRISON ENGINEER ND VISAKHAPATNAM
As per NIT
8 documents required · 8 mandatory
₹3,000
GARRISON ENGINEER ND VISAKHAPATNAM
₹7.6 L
Yes
22 Oct 2022
5 May 2022
2 Sept 2022
5 May 2022
31 Aug 2022
25 Aug 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XIII: NOTE: Schedule "A" Part – I to Part – XIV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE /EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "ROADS /PATH/CULVERT", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "CHAINLINK FENCING", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM & FIRE ALARM", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "DEMOLITION", as listed in Schedule "A" Part – XIII
Schedule "A" Part - XIV: [Miscellaneous Items] [Internal Electrification, Sewage Disposal, External Water Supply, External Electrification, Road/Path/ Hard standing/culvert, Fire fighting & Fire alarm, Lightening conductors,Demolition and Lift]
M & L point wiring complete with 1100 Volts, FRLS grade, 1.5 Sq.mm, Single core, PVC Insulated, unsheathed, multistranded copper conductor cable, confirming to IS - 694 drawn through and including medium grade PVC conduit, 20 mm dia including all accessories concealed in walls / roofs / floors / ceiling etc. and pressed GI modular box as per OEM for switch/ sockets and suitable size as required at site and suitable for modular brackets for fixing modular switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, single sore, PVC insulated, unsheathed, multistranded copper conductor cable as earth continuity conductor with colour coding and connecting to earth dolly for one light / fan point / exhaust fan / ceiling rose point controlled by one modular switch complete all as specified. for the following Note:Cost of modular GI box and modular outer cover plate shall be included in the quoted rate.
All as per Serial Item No. 14 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per Serial Item No. 14 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
All as per item No.14 here-in-before but controlled by two two way switch complete all as specefied and directed.
M & L point wiring complete with 1100 Volts, FRLS grade, 4.0 Sq.mm, Single core, PVC Insulated, unsheathed, multistranded copper conductor cable, confirming to IS - 694 drawn through and including medium grade PVC conduit, 20 mm dia including all accessories concealed in walls / roofs / floors / ceiling etc. and pressed GI modular box as per OEM for switch/ sockets and suitable size as required at site and suitable for modular brackets for fixing modular switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLS Grade, 4.0 Sq.mm, single sore, PVC insulated, unsheathed, multistranded copper conductor cable as earth continuity conductor with colour coding and connecting to earth dolly for 3/5 pin 15 Amp socket outlet point controlled by one modular switch of 15/16 Amp complete all as specified. for the following Note:Cost of modular GI box and modular outer cover plate shall be included in the quoted rate.
S&F 2 feet x 2 feet recess mounted LED light flat panel [2x2] 36 watt of 3000 to 3600 lumens with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S&F surface or wall mounted LED tube light fitting with polycarbonate housing and integrated electronic driver professional WH 5700K to 6000K and 2000 lumens of cool white complete with mounting bracket etc., including connecting upto suitable size copper cable complete all as specified as directed
Supply and fix LED Tube light fitting 2 feet long of 10W of 900-1000 Lumens, 6000K with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
Supply and fix LED midbay light of 50W minimum 5000 lumen with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing of ceiling fan complete with blades, down rod, electronic regulator and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed.
Supply and fixing exhaust fan, 300mm sweep, 900 RPM heavy duty with louvers, AC single phase, 230 volts including connection with 0.5 sqmm copper conductor flexible wire from ceiling rose complete all as specified and as directed.
Supply and fixing exhaust fan, 450mm sweep, 900 RPM heavy duty with louvers, AC single phase, 230 volts including connection with 0.5 sqmm copper conductor flexible wire from ceiling rose complete all as specified and as directed.
M & L for sub-main wiring with 6.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 25 mm dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 6.0 Sqmm + one run of 6.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 25 mm dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
Supply and fixing of Factory made sheet metal enclosure VTPN DBs double door (Fixed flush to the wall) with a provision for fixing of TPN MCCB as incommer 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 4.0 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified. Note :-MCCB and MCB should be measured and paid separately.
Supply and fix MCCB 125 Amps, 4 pole, 25 KA complete all as specified.
S & F MCB TPN 63 Amps, 415 Volts, 10 KA, 'C' Curve complete all as specified and as directed.
S& F LED Security light 30 watt with 3000 Lumens, 5700K Pressure die cast aluminium housing, IP-65 protection with all acessories internally prewiried and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made up of 25 mm dia GI pipe medium grade or suitable size as per site requirement 1.5 Mtr length fixing for building security light fittings with clamp, bolt, nut and washers compelte all as specified and as directed.
M & L earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to GI earth lead wire 4.0 mm dia [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth wire upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.
Cutting existing CI water mains of dia 300 mm and inserting 150 mm dia for alterations or additions suitable sizeand connecting line from existing 300 mm dia line to 150 mm dia complete all as specified and directed by Engr-in-Charge.
M & L for masonry valve chamber of size 750 X 750 X 750 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
Supply, Installation,Testing and Commissioning of submersible pump, electrical driven, 415 Volts, TP suitable for 65x 50 mm dia bore pipe, 3 WHP/ 5HP, with discharge capacity 850 LPM, 33 Mtrs headincluding all acessories as per site /technical requirement complete all as specified and as directed.
Supply and lay flat submersible cable of size 10 Sqmm 4 core suitable for submrsible pump complete all as specified and as directed.
Supply and fix 3 Phase, 415 Volts, 50 Hz, DOL starter along with contactor of suitable capacity with enclosure for openwell submerisible pump of capacity 5HP complete all as specified and directed
M & L for cutting existing road/PCC/drain of size 150 mm wide 230 mm deep for laying under ground cable making good to match with the existing surface with PCC 1:3:6 type C1 [using 20 mm graded stone aggregate] including necessary earth work complete all as specified and as directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth strip upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.
Supply, install, testing and commissioning of LT panel of suitable size, made out of 3.15 mm thick CRCA sheet including framing with angle iron of size 50 x 50 x 6 mm, outdoor compartmental type totally enclosed, factory made powder coated dust and vermin proof with front and rear opening, double door with locking arrangement, 415 Volts, 3 Phase, 4 wire, AC 50 Hz, having Aluminium bus bar of 200 Amps for phases and 200 Amps for neutral, RYB insulated with PVC sleeves insulation mounted on porcelain insulator, Panel foundation with PCC pillars 02 Nos with PCC 1:3:6 type C2, minimum 300mm below ground and 450 mm above the normal ground level including MC 75 MS Channel frame medium grade at bottom of panel with 4 Nos bolts 200mm long of 16mm dia grouted in PCC pillar to tighten the panel, internal wiring, inter connections of all accessories and all cables with adequate size aluminium lead / strip and wire, lugs & glands complete as per CPRI Norms with and including the following accessories :-
Supply and fix MCCB 63 Amps, 4 pole, 16 KA, 415 Volts, 50 Hz complete all as specified.
Supply and fix LED street light 70 W, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP:66 protection and impact resistance of IK07 IP 65 including 1.5 M long 20 mm dia GI pipe bent to shape, MS flat bracket mounting clamps, bolt, nuts and washers complete all as specified.
S & F loop in loop out box of size 250x250x100 mm FRP made with IP 65 protection of thermoplatic circuit breaker boxes with metric knockouts for cable entry and exit, combiclimate Cable Glands of IP66/IP67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, 'C' Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands etc all as specified and directed.
S&F PVC flexible copper Conductor sheathed cable of size 2.5 Sqmm 3 core complete all as specified and directed.
M & L for 200 mm compacted thick granular sub base [GSB] grade V laid in two layers (each layer shall be rolled separately) confirming to grading as specified, spread, rolled and consolidated to required gradient and camber using mechanical paver/ grader & vibratory soil compactor of capacity 8 to 10 tonne complete all as specified and directed. Note: (a) Pavement shall be made for solid quantity arrived after consolidation [b] Compaction of granular sub base shall be carried out under optimum conditons to achieve 98.5 modified density. [c] Curing shall be done as per IRC recommendations. [d] Before execution the material obtained from source shall be tested. [e] Contractor shall use vibratory earth compacter to achieve 98% MDD at OMC and method of compaction to be adopted as per recommendations of testing agency reporting MDD at OMC. [f] GSB shall be executed as per MORTH specifications.
Supply, Install, testing and Commissioning of National Fire Protection Association Standard 72 (NFPA 72), Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules manufacturer's recommendations, with 32 bit processor Arm Cortex M3, 160 (40X4) character LCD display, RS 485 Communication for Network/Repeater, based Intelligent Addressable Fire Alarm Control Panel, including supervised electronic provision to store site-related back-up, inbuilt battery charger, Configuration Software Back-Up, Reports, Logs, etc., with all accessories, complete all as specified and directed. (01 as repeater panel)
Supply and Lay [black coloured] 2 core 1.5 sqmm flexible power cable, PVC insulated and round sheathed wire features a bright annealed bare copper conductor, voltage grade up to 1100 Volts,including all accessries complete all as specified and directed.
M & L for 150 mm dia ductile iron pipe spigot and socket type centrifugally cast (spun) all as per IS:8329-2000, class K9 with flexible rubber gasket push on type joint having cement mortar lining with portland slag cement as per IS 455 : 1989 bituminous coating as per Annex 'C' of IS 8329, including provision of specials, such as tee's, elbows, bends, reducers, taper pieces complete all as specified and directed.
S & F 150 mm dia foot valve flanged ends with brass stainer, suitable flanges, nuts, bolts, gaskets confirming to IS:4038 complete all as specified and directed.
S & F 100 mm dia foot valve flanged ends with brass stainer, suitable flanges, nuts, bolts, gaskets confirming to IS:4038 complete all as specified and directed.
Supply and fix hose reel of 20 mm dia and 30 meter length conforming to IS 884 for first-aid system connected to the wet riser complete all as specified and directed.
Supply and fix Cast Iron air release valve with two air outlets of 150 mm dia bore complete all as specified and directed.
supply and install of Fire extingushier stored pressure water type of 9 Litre capacity conforming to IS 15683 complete all as specified.
supply and install of Fire extingushier CO2 [light weight squeeze grip type of 3Kg capacity] conforming to IS 15683 complete all as specified.
Supply, install, testing & commissioning of Goods Lift, speed 0.5 metre/sec, with single speed motor 415 Volts, 3 Phase, AC Supply, 50 Hz confirming to IS - 14665, suitable to serve 2 Ton (2000Kgs), 2 Floors [G + 1] , full collective operation [Minimum travel around upto 6 mtr] Upper Floors with AC VVVF Drive [Variable Voltage & Variable Frequency Drive] complete with all accessories, regenerative type [Closed Loop], Automatic & Manual dual controlled operation with/without attendant, centre opening doors with door drive [electric motor driven mechanism], sliding stainless steel doors, with moon rock finish of MS collapsible gate MS spray painted , with/without vision panel as landing door with ARD with automatic rescue device [ARD] system, 3D infra red sensor in full height of door & built in announcing system without hand set [03 Nos., one each in Car, Machine room & near Ground floor landing door] complete all as specified and directed , Inclusive Equipment / Machinery Earthing of GI Plate 600x600x6mm by using aluminium strip 32x6 of size as per SSR specifications up to Earth pit & Equipment, dimension of lift well and distance between floor to floor shall be all as shown on drawings. Note: The lift shall be provided with and including the following: [a] Fireman Switch [b] Automatic Rescue Device during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. [c] Battery operated Emergency Light [LED Ceiling Fitting] alarm [speaker for emergency alarm system to be fixed] and stop button in car with reachable arrangement for battery. (d) Type of machine-Geared, full collective operation, with ACVVVF Drive.
[e] Wire rope of adequate size as per relevant IS and as per manufacturers specification. [f] Nonstop button/independent operation. [g] Over load warning indicator visual type [h] Front landing door of stainless steel moon rock finish, operations with a minimum time of 10 sec. [i] Car size shall be in conformity with IS 14665 and body to be stainless steel of 16 gauge moon rock finish with stainless steel hand rail. [j] Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. [k] Stainless steel hand rail 38mm hairline finish. [l] Specification plate [m] Continuous earthing for machine and equipment [n] Other standard fixtures and fittings like rails, sheaves, counter weights with guards, buffers, gear unit, brackets, control panel, power control and trailing cables complete all as per latest IS specifications. [o] Lift design, specifications, drawings, manufacturers instructions shall be got approval from Accepting Officer before placing order for procurement.
[p] Car Door & Landing Door opening in Moon rock finish [16 Gauge thick] with/without vision panel of (i) car inner dimension -1700x2500mm How ever dimension vary as per site requirement (ii) Clear entrance-1700x2000mm How ever dimension vary as per site requirement (iii)Hoist way required -2600x2800mm How ever dimension vary as per site requirement (iv) Elevator pit required-Depth-1600mm or vary as per site requirement (v) Over Head -4200mm or vary as per site requirement . [q] The rate quoted by the contractor is deemed to be including the cost of necessary civil works as required at site including demolition of dummy walls etc. and making good the surface to match with the adjacent finishes. Nothing shall be paid extra on this account.
Schedule "A" Part - XV: [Miscellaneous Items] [comprehensive Maintenance of Lifts]
Comprehensive maintenance of Electrically Operated Goods lift (2000 Kgs) to serve G+1 upper floors all as mentioned vide SI No. 56 of Sch "A" Part - XIV [BOQ] during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated Goods lift (2000 Kgs) to serve G+1 upper floors all as mentioned vide SI No. 56 of Sch "A" Part - XIV [BOQ] during 2 nd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated Goods lift (2000 Kgs) to serve G+1 upper floors all as mentioned vide SI No. 56 of Sch "A" Part - XIV [BOQ] during 3 rd year after expiry of defects liability period all as specified and directed
Note for comprehensive maintenance:- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts & consumables like topping of gear oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personal as specified in particular specification and as recommended by Engineer-in-charge and lubrication to all moving parts, topping up of oils as per lubrication chart including materials and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical and control circuits and mechanical components of the lift that may occur during the operation.
(iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by site engineer and contractor. (v) Load testing shall be arranged by the contractor to the lift for whose repairs were carried out as when directed by Engr-in-charge. (vi) All maintenance works shall carried out by well qualified tradesmen and supervisor of OEM. (vii) The quoted rate shall be deemed to be included the above aspects and for consumables such as timely topping up/replacement of gear oils, acrylic covers, fuses, copper cables, hardware like bolts, nuts, emery papers, grease, waste cotton, stationary and other miscellaneous items and all minor & major parts. (viii) The contractor shall submit the MOU with the OEM for carrying out comprehensive maintenance of lift at least 6 months prior to the date of completion of work.
anjaliinfratech
SVS PROJECTS
jd constructions
VENKATA SAI SRINIVASA CONSTRUCTIONS PRIVATE LIMITED
S V S ENTERPRISES
BALAJI MATRIX HOLDINGS
Bidder Name
BALAJI MATRIX HOLDINGS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .