| 3 | L3₹47.0 L+₹1.0 L (2.26%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
7 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
SPL REPAIR TO BLDG NO P119 AND OHTER SANCTIONED WORKS IN THE AREA OF AGE B/R-I UNDER GE (A) NO 1 JODHPUR
2024_MES_683124_1
GE/JODH (A) NO 1- OF 2024-25 (9282/E8)
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE ARMY NO. 1
₹96,000
24 Jan 2025
8 Nov 2024
14 Dec 2024
8 Nov 2024
7 Dec 2024
23 Nov 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
M&L PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundation , filling, sub base and mass concerete complete all as specified and as directed.
M&L 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight in 2 mtr interval, complete all as specified and directed.
Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any description, ( colour, design & pattern, & size/ shape, as approved by GE) as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including M&L 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
Demolition of brick / block or stone / boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
M&L for squared rubble walling, Jodhpur type, regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed.
All as per item No. 8.00 here-in-above, but except stone.
M&L precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in solid block masonry, 10cm width and setting in cement mortar 1:4 including demolition complete all as specified and as directed .
Extra over stone walling for hammer dressing to face stone & dressing of face beds & joints as specified of squared rubble walling Jodhpur type brought upto courses with maximum depression of face from straight edge held against the dressed surface n exc 20mm and dressing face beds and joints, complete all as specified and directed.
Dismantling, stone slab, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as directed.
M&L for 25 mm thick cement concrete 1:2:4, type B-0 (using 12.50 mm graded crushed stone aggregate), as in base course, to receive floor finishes, complete all as specified & directed.
M&L for joint free non skid ceramic coloured tiles (premium quality) of size 6 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm (size & shape, shade and pattern as approved by GE), as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including M&L 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
All as per item No. 14.00 here-in-above, but as in skirting/dado with 10mm thick backing coat in CM 1:3
All as per item No. 14.00 here-in-above, but area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm
M&L for glazed colour ceramic tiles (premium quality) of size 300X450X6-7 mm, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including M&L 10mm thick backing coat in CM (1:3), (including Highlighter pattern), complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded, pointed in motar, complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid dry or laid dry and pointed complete all as specified and directed.
M&L Machine cut kota stone slab flooring using 20 to 25mm thick slabs,as in shevles (single piece), the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including rounding to edges of kota stone fixed with mortar complete all as specified and as directed.
M&L for 18 to 20 mm thick (telephone black shade) granite stone, as in cooking plateform, oval type WHB counter, sink & etc. machine cut, (table rubbed and polished) best quality as per sample, including & over 20 mm thick screeding in CM1:3 including rounding & double mouldlng with jointless finish of the edges, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.providing suitable dia hole in the slab for the gas pipe, complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed.
M&L Rendering 5 mm thick CM (1:3) on concrete surfaces on ceiling / facia /RCC Chhaja etc all as directed & finished even & smooth complete
M&L for 15mm thick rendering in CM 1:6 finished even and smooth without extra cement on stone wall surface complete all as specified & directed.
M&L for 10mm thick rendering in CM 1:6 finished even and smooth without extra cement on stone wall surface complete all as specified & directed.
Racking out joints/ pointing to random rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed
M&L keyed pointing in cement mortar (1:3) to squared rubble masonry coursed or un coursed complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces and applying 2 mm thick wall care putty on wall surfaces including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper paint on wall surfaces as per manufacturer’s instruction, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- Paint shall be in one or more colours/ shades all as approved by GE.
M&L for complete removal of existing treatment and applying 2 mm thick wall care putty on wall surfaces including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper paint on wall surfaces as per manufacturer’s instruction, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- Paint shall be in one or more colours/ shades all as approved by GE.
M&L for Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash on ceiling surfaces complete all as specified and as directed.
M&L for preparation of old decorated wall surfaces plastered or unplastered, by brooming down or steel wire brushing, scrapping down moulds, moss and efflorescent salts and trading oil & greasy spots, including cornices etc and applying one coat of white wash on wall, complete all as specified and directed.
All as per item No. 31.00 here-in-above, but as on ceiling
M&L preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint over a coat of white cement as primer, complete all as specified & directed
M&L for preparation of old decorated wall surfaces plastered or unplastered, by brooming down or steel wire brushing, scrapping down moulds, moss and efflorescent salts and trading oil & greasy spots, including cornices etc and applying one coat of cement base paint on wall, complete all as specified and directed.
M&L Preparation of new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over & including M&L single coat of pink primer complete all as specified and as directed .
M&L preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over & including M&L single coat of red- oxide, zinc chrome primer complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area not exc 1.5 Sqm each, complete all as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
M&L for rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars ,barred iron doors; ladders ;framed balusters walk ways railings framed work of water tanks and similar work confirming to Fe-290Gde E-165 complete all as specified and as directed.
M & L for mild steel framed work as in brackets etc., for cooler stands /steps/stairs etc., supporting frame work to sunshade, with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel'), complete all as specified and as directed.
S&F mild steel frame work as in stairs ,hand rails half round or other stock section or section or core for wooden hand rail straidgt portion drilled and countershunk for balusters running bars for doors balusters nosing to steps including embeded in concrete and screwing etc hid ties for roof including securing bolts, post and struts in fencing including securing bolts post and struts in fencing including cutting tops to shape as directed drilling holes nothing for wire etc flat iron fillet for necessary drilling boltinh or riveting etc and similar work confirming to Fe-290 Gde E-165, complete all as specified and as directed.
M & L 16-18 mm thick pvc sheet as in kitchen cabinet & wardrobe, 100 mm width frame including both side mica lamination with first quality branded hardware, complete all as specified and directed.
S & F (a) 35mm thick factory made second class hardwood glazed and Skelton door shutters, open rebated and prepared to receive glass/gauze etc(without sash bar) edges of framing plain chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-1991 section 8 clause 8.24 (b) supplied and fitted to chowkhats complete all as specified (b) ss wire cloth 0.36 mm nominal dia of wire , avrage width of aperture 1.40mm fixed with ss wire staple (c) aluminium grill medium grade mess size 50x500mm , fixed atouter edge at outer edge of door (d) primer-pink
M&L factory Made flush shutters, 35 mm thick solid core with block board core construction as per IS 2202(part-I, 1999), both side decorative type lamination. The stiles & rails shall be with out any joint and made with non- coniferous timber hard wood (Hillock/ Mirantee/ Bosum/ Benteak) with moisture content not less than 12% as per IS. The face panel comprising of ply wood or cross band and face veneers shall be glued by hot pressed process. The over all finished thickness of face panel shall not be less than 35mm while the thickness face veneer shall not be less than 0.6 mm complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
M/L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: (a)-For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. (b)- M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately.
Taking down steel windows and ventilators ( glazed / fly proof) of any description complete all as specified and as directed.
M&L for factory made box type steel window with pintle hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer,( (with or without cooler opening ) complete all as specified and directed. Note:- Glass panes & wire cloth shall be measured and paid seperately.
All as per item No. 48.00 here-in-above, but without glazing bar.
M&L for factory made box type steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified Note:- Glass panes & wire cloth shall be measured and paid seperately.
All as per item No. 50.00 here-in-above, but without glazing bar.
S&F of aluminium anodised, tower bolt 200 mm long complete all as specified and directed.
S&F aluminum anodised handle extruded section of size 150mm long, complete all as specified and directed.
S&F of aluminium alloy anodised sliding door bolt woth hasp and stalpe (bolt type and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long, complete all as specified and directed.
S &F of stainless steel butt hinges 100 mm size complete all as specified and directed.
S &F of mild steel, cold roll mild steel, butt hinges 100 mm size complete all as specified and directed.
S&F Double action spring hinges, mild steel with steel wire spring, stove enamelled, black , 100mm size spring hinge, complete all as specified and directed.
S&F 140 mm floor door stopper of aluminium alloy body and tongue , anodised ,with hard drawn steel spring ,fixed in floor, complete all as specified and directed.
M&L Figured glass 4.00 mm thick, pin head type and glazing with putty in square not exceeding 0.50 Sqm in each pane complete all as specified and as directed.
S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
S&F in repairs galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks or GI wire staples complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B-1 by using 20 mm graded stone aggregate as in bed block for fixing of hold fast complete all as specified and as directed.
S&F Mild steel work as in hold fasts, clamps, bands, straps or stays, wall ties, hooks etc confirming to Fe - 290, Grade E-165 including prepartion of surfaces and treated with coal tar and sanded with clean sharp sand complete all as specified and as directed.
S&F in replacement decorative type curtain rod stainless steel finish of pipe 22 to 25mm dia with best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end, complete all as specified and as directed.
S&F in repair shelf of PTMT fixed with and including chromium plated brass screws and wooden cleats (Min weight 300 gms), complete all as specified and directed.
S&F in repair soap dish of PTMT fixed with screws complete all as specified and directed.
S&F in repair PTMT towel rail 450mm long, fixed to wall with chromium plated brass screws and wooden cleats (Min weight 170gms), complete all as specified and directed.
S&F in repair MS chromium plated peg set of five fixing with wall complete all as specified and directed.
S & F in repairs white vitreous china squatting pan "Orissa pattern" of size 580 mm X 440 mm with integral foot rests and PVC 'P' or 'S' trap, connecting to drain pipe and flushing pipe etc., including provision of cement concrete bedding 1:5:10 type E2, complete all as specified and as directed.
S & F in repairs vitreous china ware wash hand basin, white, flat back of size 580 mm X 450 mm including 32 mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe, complete all as specified and as directed.
Dismantling of cast iron/PVC SWR pipes of 100/110mm bore, including fittings, jointed in cement mortar complete all as specified and as directed.
All as per item No. 72.00 here-in-above, but 75 mm bore pipe
S & F sand cast, cast iron, soil / waste / vent pipes, 100mm bore, in any length with or without ears, jointed with cement sand mortar, laid in trenches or in floors complete all as specified and as directed.
All as per item No. 74.00 here-in-above, but 75 mm bore pipe
All as per item No. 74.00 here-in-above, but fixed to wall with MS clamps
S& F 100 mm bore cast iron branch piece, single (single Y) equal or unequal with access door complete all as specified and as directed.
All as per item No. 83.00 here-in-above, but 75 mm bore pipe
S&F100mm CI bends any radius complete all as specified and directed
S&F 75 mm dia CI bend with oval acess door fixed to pipe complete all as specified and directed.
S&F 100mm dia CI vent cowl fixed to pipe complete all as specified and directed.
S & F in repairs 75mm bore cast iron nahani trap with grating including jointing to waste pipe, fixed in cement concrete type B1, 1:2:4 complete all as specified and as directed.
S&F in repairs Pillar taps, fancy type Cast copper alloy, with capstan heads chromium plated, screwed down high pressure, with or without lettered 'Hot" or Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed to 15mm bore pipe complete all as specified and as directed.
S&F in repair stop valves, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends suitable for 25 mm bore iron pipe or for unions complete all as specified and as directed.
S&F in replacement angular stop cock with wall flange, half turn, chromium plated brass, fancy type 15mm dia complete all as specified and as directed.
S&F in replacement two way angular stop cock with wall flange, chromium plated brass, fancy type 15mm dia complete all as specified and as directed.
S & F CP hand shower, (Health faucet) with 1m long flexible tube with wall hook with Non Return Valve [back flow preventer] complete all as specified and as directed.
S&F in replacement bib cock with wall flange, chromium plated brass, fancy type 15mm dia complete all as specified and as directed.
S&F in repairs 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia, complete all as specified and as directed.
Disconnecting existing tanks setting aside [or lowering if required] for repairs,cleaning etc., and hoisting if required reconnecting and refixing in position of water tanks of capacity 500 litres, complete all as specified and as directed.
S&F 500 ltrs capacity rotational moulded polythene water storage tanks white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms complete all as specified and as directed.
M&L 50mm thick PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate for plate form for water tank on roof complete all as specified & directed
Demolition of reinforced cement concrete any description such as roof, floor slab, beams, stair case, landing, chajjas, column and similar suspended work and removing rubbish to out side MD land complete all as specified and as directed.
M&L Precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in landings, cover slabs (for man holes etc) chullah hoods,chajjas,water troughs,shelves and similar articles with plain faces complete all as specified and as directed .
S&F 5 cm thick sand stone slabs Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar (1:4) complete all as specified & directed
Supply only integral water proofing compound ISI Marked all as specified.
Taking up or down 20mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and directed.
All as per item No 97.00 here-in-above, but size of pipe 15mm bore.
S&F GI water tubing medium grade, 20 mm bore size, galvanized, with all fittings fixed to wall, ceilings or laid in floors, complete all as specified and as directed.
All as per item No 99.00 here-in-above, but size of pipe 15 mm bore size, including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc., complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed.
From work to edge of concrete flats, treads, breaks in floors, window cills, concrete railing, opening in concrete walls, floor and roofs n exc 20 cm wide and side of RCC/PCC bands in walls horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide with fair finished surfaces complere all as specified and directed.
Use and waste of form work to sides and soffits of lintels, beams, brackets, shelves and similar works for rough finished surfaces of concrete complete all as specified and as directed.
M&L RCC M-25 design mix as in slabs supported on walls, beams and colunms in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L RCC M-25 design mix as in beams, cantilevers, bressummers, lintels over 1.5m span, plinth band, etc., complete all as specified and as directed.
S & F TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
S & F TMT bar 6 to 8 mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
S & F TMT bar 5 dia and over upto and including 10 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
M&L for neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions over the RCC roof slab for laying of water proofing treatment including providing the following as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 100mm micron HMHDPE, outer film 20 micron each, thickness 3.00mm having weight not less than 3.00 Kg/Sqm, mineral gravel finish on top, using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen conforming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FIFTH COURSE : 40 mm thick plain cement concrete 1:2:4 (using 20 mm stone crushed aggregate) as in roof padding, including WPC as per manufacturer instruction. NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item.
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil, complete all as specified and as directed .
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft disintrigated rock, complete all as specified and as directed .
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soils complete all as specified and directed.
Removal of excavated material soil to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L Hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, with 8-10 tonne power roller, complete all as specified and as directed.
M&L 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as DPC & finishing the surface even & smooth with using extra cement complete all as specified & directed
S&F 1mm thick lath Steel rolling shutters, gear operated typewith bevel gear box and crank handle, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and erected in position as indicated, gear operated type with bevel gear box and crank handle complete all as specified and as directed.
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
Taking down carefully UNSV submain wiring of any size and all as directed.
M & L for (concealed) point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLS cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC concealed (including Cutting Chases and make good the distrubed surfaces ) conduit of size 20 mm or med grade as required as site, totally concealed in walls / and surface on floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end suitable for One light/fan/bell point controlled by one, one way switch, complete all as specified and directed. The rates of chase cutting on wall done concealed conduit and steel terminal boxes are included in the unit rates all as specified and directed by Engr-in-Charge.
All as per item No. 121.00 here-in-above but suitable for one socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
All as per item No. 121.00 here-in-above but suitable for one socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
All as per item No. 121.00 here-in-above but with 4 sq mm FRLS copper wire with 4 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
S&F Switch piano type, single pole, one way, 6 amps, 230 volts, complete all as specified and directed.
S&F Socket,3 Pin, 5 Amp, universal type, 230 volts, complete all as specified and directed.
S&F Switch piano type, single pole, one way, 16 amps, 230 volts, complete all as specified and directed.
S&F Socket, 6 pin, 6/16 Amp, multipurpose , 230 volts, complete all as specified and directed.
S&F Lamp holder, metal cased, bakelite body, 230 volts, complete all as specified and directed.
S&F LED lamp 9W complete all as specified and directed by the Engineer-in-Charge.
S&F Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.
S&F resistance type regulator Socket type stepped type A/C 240 Volts.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including AC decorative box type with driver, holder including,copper conductor cable of suitable size from ceiling rose complete complete, 4 ft long all as specified and directed.
S&F bldg security LED Light Luminaire of 35 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 40 mm bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable complete all as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
M&L for taking down old serviceable fan and refixing in same position after painting including connectoin from celing rose to fan connector all as per directed by Engr-in-Charge
S&F Vertical Distribution Board, double Door, suitable for 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 6 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Note : MCCB & MCB will be measured and paid separately under respective items
S&F MCCB, A Frame, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 100 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as directed.
S&F MCB, B Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as directed
S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed.
Supply and fixing as MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall incl dismantling of old UNSV DB all as specified and directed by the Engr-in-Charge.
M&L for sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 15 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
Earthing complete with galvanised steel earth plate electrode 60 x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal ground level, nnected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate no. 5 connected to Earthing test point all as ecified or indicated including testing on completion( Rates are deemed to be included for necessry earth work ,PCC pit , RCC cover & GI 15 mm dia protection pipe upto 7.5 mtr. lead etc. complete )
Supply, laying testing in trenches LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 25 sqmm 3.5 core all as diredted by Engr - in - charge. Note : Earth work and brick work measured and paid separately
Supply and lay sand for sand cushioning for cable protection in trenches all as directed and specified in SSR Part - 1.Note:. for the purpose of payment punned thickness will be measured.
Supply and laying Un reinforced Precast concrete cable cover, flat size 300 mm x 180 mm x 40mm all as directed
Supply and fix in replacement of GI tubing of size 40mm bore, medium grade for protection of cables on poles / under road crossing complete all as specified and as directed.
M & L for road cutting(not more than 3.5 mtr in width of road) and excavation upto 60 cm below ground level and laying of 5 running mtr protection 40 mm dia GI pipe of medium grade and make good distrubuted suface by PCC 1:4:8 (nominal mix), type D-2, using 40mm graded crushed stone aggregate complete all as directed
M&L for geyser 50 Ltr horizontal type storage type ISI Marked , Energy efficient , 5 Star rated , including fixing arrangement by means of drilling hole in wall , grouting rack bolts fastner 100 mm long and Including connection pipe hot and cold water complete all accessories And making good to distrubed surface complete. Note : 50l Mounting Vertical Star Rating as per BEE Standard 5 star Warranty 7 year warranty on inner container ; 4 year warranty on heating element ; 2 year comprehensive Warranty .
M&L for power point wiring/ sub main wiring with PVC insulated and unsheathed 2.5 Sqmm single core multistrandred copper conductor cable passing through in and including PVC Concealed conduit MMS, fixed to walls, ceiling etc, making good the distrurbed surface, incl 2.5 Sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note : - Two runs of cable 2.5 Sqmm and one run of 2.5 Sqmm along with conduit shall be measured as one unit length.
M&L for metal clad enclosure three pin plug and scoket complete with MCB SPN 20 Amps Complete All as specified and directed by Engr-in-Charge.
Supply and fix MCB SP 20 Amps in Exiting DB as par location complete. All as specified & . Directed.
M&L for writing letters in black colour paint 40mm width :- (a) Manufacturer srl No. (b) Date set to work. (c) Initial cost. (d) PRB page No. (e) Location etc, complete.
S&F Chromium plated brass stop valve 15 mm ISI Marked , high pressure both end screwd .
S&F PVC connection 15mm dia, 450 mm long with brass alloy crome plated nuts , suitable for hot and cold water application ISI Marked .
M & L for cutting existing location and position galvanised pipe upto 50mm dia inserting tee of required size and connecting 15 mm dia pipe in each geaser, complete all as specified and directed.
Note:- Qty's have been clubbed from 3 Nos sanction Job's, whose details as per appx (ii)- Qty's of BOQ Item No. 118.00 to 148.00 are only consider in Job No. 11 / SR (BLDG) / JODH/ 2024-25 (iii)- Qty's of BOQ Item No. 149.00 to 156.00 are only consider in Job No. JODH/MW/10/2024-25 NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
SURESH TRADERS (BID ID -3177508)
M/S KAUTILYA GARG (BID ID -3183610)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .