Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Being lowest bidder and reasonbale | |
| 2 | L2₹28.6 L+₹2.5 L (9.51%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹28.4 L+₹2.3 L (8.65%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹29.1 L+₹3.0 L (11.5%)Rejected-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹30.7 L+₹4.6 L (17.5%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
20 Nov 2020, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
OUTSOURCING SERVICES FOR OPERATION AND MAINTENANCE OF CENTRAL TYPE AC PLANTS, COMPREHENSIVE MAINTENANCE OF DUCTABLE ACs , REPAIRS AND SERVICING OF SPLIT/WINDOW ACs AT MTRDC AREA, BANGALORE
2020_MES_384478_1
GE(I) R ND D (WEST)/BAN/42 OF 2020-21 8839E8
Open Tender
Manpower Supply
Item Rate
330 days
Bengaluru
Refer NIT for details
8 documents required · 8 mandatory
₹500
Yes
GE I R nd D West Bengaluru
₹56,000
Yes
22 Dec 2020
29 Oct 2020
26 Nov 2020
30 Oct 2020
20 Nov 2020
14 Nov 2020
30 Oct 2020 - 13 Nov 2020
Amount
SCHEDULE 'A' PART - I (OUTSOURCING SERVICES)
Providing services in Operation of centralised air conditioning plant 25 ton capacity of Make :- Voltas ( in 1 x 25 TR) installed at MTRDC main building, ductable type air conditioners 3 x 5 TR at HV lab, 2 x 8.3 TR and 6 x 5.5TR at JC bose building for smooth and efficient performance as required to achieve optimum/desired room temperature condition with following manpower from 8.30 to 16.30 hours per day excluding sundays and holidays (Plant Operator (Semi Skilled) - 1 No, Helper (Unskilled) - 1 No) all as specified and as directed.:-
Notes for Sl Item No 1.00 to 2.02 (including Sub Items) Contd., (i) Absent from duty of technician is not permissible as E&M services essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery from bill shall be done through recovery statement.The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding. (ii) Details of equipment/services to be maintained are indicated as appendices in PS. (iii) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, EDLI, ESIC, Bonus, GST, Cess & other levies payable shall be strictly adhered to by the contractor. The Contractor shall produce proof of wages, EPF, ESIC, Bonus paid against the respective workmen while claiming payments. (iv) The rates quoted by the Contractor / firm shall not be less than minimum wages as notified by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable. (v) Bidders are advised to follow the websites/ notifications of respective Department/ Organization regularly, and ensure that any changes in minimum fair wages/ contributions, Taxes are accounted by them and revise their quoted rates accordingly before end date of submission of Bid. No claim of not aware of new Notifications / Circulars will be entertained after bids are closed on account of revisions. vi) Tenderer shall work out and quote the rates under Col 5, Col 7, Col 9, Col 11 & Col 13 for each item / sub items. Rate quoted under Col 9 (overheads and Profits) shall also deemed to include for consumable items, uniforms, stationery charges, etc., required for proper operation and maintenance of equipments.
Notes for Sl Item No 1.00 to 2.02 (including Sub Items) Contd., vii) Bid submitted by Tenderer under following stipulations shall be treated as non - bonafide / invalid / disqualified and such bids will not be considered for acceptance and in such case the lowest bidder shall be determined from amongst the valid / bonafide bids only :- a) Quoting wages under Col 5 against any item / sub-items of BOQ shall not be less than the prevailing minimum rates of wages payable as notified by Govt. of India/ Concerned State Govt / Local body whichever is higher. b) Quoted rate under Col 7 i.e., Bonus, shall not be less than Minimum payable (8.33%) and shall be based on actual payment basis. c) Quoted % under col 9 i.e., for “OH&P, consumable items, uniforms, stationary, etc., should not be “Nil”/”Zero” consideration, d) ESIC % under Column 13 is @ 3.25% subject to Salary less than 21,000/- as per instructions in vogue vii) In case Contractor is liable to pay EPF, % quote under Column 11 shall not be less than % applicable as per EPF & MP Act and its latest notifications / amendments. viii) Quoted rates shall deemed to be inclusive of all taxes, cess, levies as applicable including GST. ix) Any Govt / statutory variations in minimum wages, liability of EPF, ESIC, EDLI, BONUS, LWC, GST shall be adjusted from re-imbursement / recovery as specified in Special Conditions here-in-after. The prevailing wages / Contribution prevailing on the bid submission end date shall be base for adjustment / re-imbursement as specified here-in-after. x) Exemptions / limiatations, if any shall not be considered while quoting rates, EPF, ESIC, BONUS, LWC as the same shall be calculated during actual contribution payable depending upon the salary of the individual based on the number of days engaged in the work.
Notes for Sl Item No 1.00 to 2.02 (including Sub Items) Contd., xi) Contractor’s attention is invited to Labour Wages Act with regards to payment of wages to the individuals engaged under this work. Contractor shall make the payments to their staff / employees by Cheque or through NEFT in their Bank Account, and the particulars of same shall be submitted to the department while claiming any payment. No payments will be made, unless proof of payment of wages through bank account is submitted by the Contractor/firm while claiming bills. xii) The wages paid, contribution towards EPF, EDLI, ESIC, Bonus, GST shall be paid by the GE in RAR / Final bill only after submission of valid and authentic document in support of proof of payment / contribution of requisite amount to the workmen by the Contractor. In case, the Contractor fails to submit proof of payment made to Workmen, no payment will be made by Department. xiii) Payment in respect of any item / sub-item of BoQ in RAR / Final bill towards the wages, EPF, EDLI, ESIC, Bonus shall be made on the actual amount paid to the Workmen by the Contractor, subject to maxium of the rate quoted under respective heads, plus his quoted OH&P & LWC and no extra claim by the Contractor shall be admissible in this account. In case, Contractor pays less than quoted rates, payments will be made on the actual amount paid by the Contractor plus his quoted OH&P & LWC and nothing extra over and above his quoted rates is payable by the Department except revisions by Govt. Any violation of Acts rests with Contractor and Contractor shall be solely responsible for same.
Rate for Plant Operator (Semi Skilled) per Shift (from 0830 Hours to 1630 Hours)
Rate for Helper (Unskilled) per Shift (from 0830 Hours to 1630 Hours)
All as per Serial item No 1.00 here-in-above, but for additional manning hours for operating beyond the period under Sl Item No 1.00 here - in - above, i.e., after 1630 hours, and for operating on Sundays / Holidays if required and specifically orders by Engineer-in-Charge / GE / Lab Director. (Plant Opeator (Semi Skilled) - 1 No, Helper - 1 No)
Rate for Plant Operator (Semi Skilled) per Hour
Rate for Helper (Unskilled) per Hour
Description of Work / Item(s)
Amount
SCHEDULE 'A' PART - II (COMPREHENSIVE MAINTENANCE AND SUPPLY OF MATERIALS)
Comprehensive maintenance of Central Airconditioning plant of 25 ton capacity 1 x 25 TR of make Voltas installed at MTRDC main building, Including replacement of worn out / defective parts and components, gas filling all as required for smooth and effecient functioning of AC plant to achieve desired cooling conditions and carrying out the complete checks as per manufacture's instructions comprising of motors, condensers, chilling unit, Air handling unit, supply and return through air ducts, control panels, safety devices etc., complete all as specified and as directed by the Engineer-in-charge.
Comprehensive maintenance of Package and ductable type Air Conditioning plants of the undermentioned capacites and locations, including replacement of worn out / defective parts and components, gas filling all as required for smooth and effecient functioning of AC plant to achieve desired cooling conditions and carrying out the complete checks as per manufacture's instructions comprising of motors, condensers, chilling unit, Air handling unit, supply and return through air ducts , control panels , safety devices etc , complete all as specified and as directed by the Engineer-in-charge. a) HV Lab - Ductable type Air Conditioner 3 x 5 TR (Make : Voltas), b) JC Bose Bldg - Ductable type Air Conditions 2 x 8.3 TR (Make Voltas) c) JC Bose Bldg - Ductable type Air Conditioner 6 x 5.5 TR (Make Voltas) Notes for Serial Item Nos 1.00 & 2.00 : (i) Details of equipment/services to be maintained are indicated as appendices in PS. (ii) Absent from duty of technician is not permissible as E&M services essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery from bill shall be done through recovery statement.The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding. (iii) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of all the labour regulations in force lies with the tenderer.The provision of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. (iv) Minimum interval of compressive maintenance shall be 01 month for each plant, (v) Minimum personnel required shall be Refrigeration Mechanic - 1 No & Helper - 1 No
Carrying out servicing of cassette/ split/ window type AC’s 1.5 Ton / 2 Ton / 3 Ton capacity of any type and make, in position, comprising of cleaning to free from dust, cleaning the evaporator, air filters, condenser coil with cleaning agent and water, tightening all electrical contacts, bolts, nuts etc., greasing / oiling blower motor, testing the serviceability, replacement of worn out rubber bushes, connector, clips, bolts, nuts, washers etc., including replacement of spares and attending to complaints on call in a day as and when required complete all as specified and as directed.. Note :- Supply of Spares / major repair jobs shall be measured and paid separately under relevant items of this schedule.
Removing the cassette/ split/ window type AC of 1.5 ton / 2 ton/ 3 ton capacity working on 230 Volts, single phase, / 440 Volts, 3 phase complete including indoor and out door unit and reinstall at any place (with in the same lab area) at height up to 10 mtr above from floor level, replacement of refrigerant tubing up to 7.5 mtrs length and provision of drain pipe and pipe insulation, connecting with existing power socket and testing the unit for smooth functioning including making good of all disturbed surfaces complete all as specified and as directed.
Taking down cassette/ split/ window type AC 1.5 / 2 / 3 ton capacity, flushing the refrigeration system with CO2, supply and charging refrigerant R-22, re-fixing in position, testing and commissioning complete all as specified and as directed.
Taking down cassette/ split/ window type AC of 1.5 / 2 and 3 Ton capacity for carrying out repairs, re-fixing in position, testing for efficient cooling temperature and satisfactory working conditions and commissioning after completion of repairs by replacing necessary spares complete all as specified and as directed.. NOTE:- Spares and major repair jobs shall be measured and paid separately under relevant items of this schedule.
Re-winding of fan motor with standard gauge super enameled copper wire including replacement of bushes, complete servicing and overhauling the motor and re-fixing for out door unit of split type AC’s 1.5 / 2 Ton capacity all as directed.
All as per Sl Item No. 7 above but for indoor unit of split type AC’s 1.5 / 2 ton capacity all as directed.
All as per Sl Item No. 7 above but for Window type AC’s 1.5 ton capacity all as directed.
All as per Sl Item No. 7 above but for split/cassette type AC’s 3 TR capacity out door unit all as directed.
All as per Sl Item No. 7 but for split/cassette type AC’s 3 TR capacity indoor unit all as directed.
Supply only condenser coil assembly complete suitable for 1.5 / 2 ton window/ split type AC complete all as specified and as directed..
Supply only evaporator coil assembly complete suitable for 1.5 / 2 ton window / split type AC complete all as specified and as directed..
Supply only condenser coil assembly complete suitable for 3 ton split / cassette type AC complete all as specified and as directed..
Supply only evaporator coil assembly complete suitable for 3 ton split / cassette type AC complete all as specified and as directed..
Supply, installation and testing factory repaired compressor including charging of refrigerant gas, leak testing etc., suitable for split type AC of 3 ton capacity of existing make including installation and testing complete all as specified and as directed.
All as per Sl Item No. 16 above but for Split / Window type AC of 1.5 ton capacity all as specified and as directed.
All as per Sl Item No. 16 above but for split/ cassette type AC of 3 ton capacity all as specified and as directed.
Supply only, Starting capacitor 80-120 Mfd, 230 Volts, AC, 50 Hz suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Running capacitor 36 Mfd, 440 Volts, AC, 50 Hz, suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Running capacitor 45 Mfd , 440 Volts, AC, 50 Hz suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Fan motor capacitor 4 / 6 Mfd, 440 Volts, AC, 50 Hz, suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Air filter suitable for 1.5 / 2 TR capacity split / window type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Air filter suitable for 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Single pole contactor up to 25 Amps suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, two pole contactor up to 40 Amps suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Auxiliary contactor single-phase 220 Volts 10 Amps current capacity suitable for 1.5 / 2 / 3 TR capacity cassette type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Start Relay, suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Thermostat, suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, PCB card, suitable for 1.5 / 2 / 3 TR capacity cassette/ split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Corded remote controller complete, suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners complete all as specified and as directed..
Supply only, Condenser fan motor for 1.5 TR/ 2 TR capacity suitable for split type outdoor unit including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Condenser fan motor for 3 TR capacity suitable for split /cassette type outdoor unit including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Copper pipe 5 /8" complete with insulation of thickness 10 mm and replacing with new items including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Copper pipe 3 /8" complete with insulation of thickness 10 mm and replacing with new items including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Copper pipe 1/4" complete with insulation of thickness 10 mm and replacing with new items including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, unserviceable PVC drain pipe 25 mm dia and replacing with new pipe including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and as directed.
Supply only, Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and as directed.
Servicing of water cooler 40 / 80 ltrs capacity of any type and make, by removing from position, cleaning of the tank, replacing unserviceable spare parts to make the incoming source of water leak proof, servicing of condensing unit, including electrical wiring to achieve proper cooling effect and reinstall in position including testing complete all as directed. NOTE: Supply only spares like compressor, spares, charging of gas, etc., shall be measured and paid separately under relevant items of this Schedule.
Disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 Ltrs and replacing the compressor and connecting the sealed unit both electrical and refrigerant connections including charging of refrigerant gas as required all as specified and as directed. Note :- Old compressor taken down/ removed shall be replaced with the same make.
Supply only Scroll type compressor including charging of refrigerant gas, leak testing etc., suitable for dutcable type AC of 5.5 ton capacity of existing make all as specified and as directed.
All as per Sl Item No. 42 above but ductable type AC of 8.5 ton capacity all as directed.
Supply only, Over load relay, suitable for Water Cooler of any make up to 40/80 litres capacity, all as specified and as directed.
Supply only, Thermostat, suitable for Water cooler of any make up to 40/80 litres capacity, all as specified and as directed.
Supply only, Package type relay, suitable for water cooler compressor of any model , after taking down old one all as specified and as directed.
Supply only, Starting capacitor, 60/ 80 mfd, suitable for water cooler of any make and capacity, after taking down old one all as specified and as directed.
Supply only, Fan motor, suitable for water cooler of any make 40/80 litres capacity, after taking down old one all as specified and as directed. Make of fan motor: AUE/ GEC.
Supply only, Push cock, brass chromium plated, self closing push button type, screwed for iron pipes of ferrules of 15 mm bore all as specified and as directed.
Supply only, PVC connection, 450 mm long, 15 mm bore with brass unions on both the ends all as specified and as directed.
Supply only, PVC ball valve set 15 mm dia of approved make for water cooler all as specified and as directed.
Supply only, Stainless steel tray suitable for water cooler of 40 / 80 Ltrs capacity all as specified and as directed.
Sub main wiring with 2 runs of cable 6 Sqmm PVC insulated unsheathed 1100 Volts grade with multi stranded FRLS copper conductor and one run of cable 4 Sqmm PVC insulated unsheathed 1100 Volts grade with multi stranded FRLS copper conductor as earth continuity conductor complete drawn in and including PVC casing and caping and its accessories complete all as specified and directed. NOTE:- Two runs of 6 sq mm cable, one run of earth contunity conductor and one run of casing and caping shall be measured as one unit length.
Supply only, PVC flexible cable PVC insulated and sheathed 2.5 sq mm 4 core with copper stranded conductor 1100 Volts grade 50 Hz.complete all as directed.
Supply and Fix MCB TP 32 Amps 'C' curve Type 415 Volts AC, 50 Hz all as specified and as directed.
Supply and Fix MCB SP 5 to 30 Amps 'B' curve Type 240 Volts AC, 50 Hz all as specified and as directed.
RAHUL ENTERPRISES
R Tech Mech
Glacier Cooling Solutions Private Limited
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
R Tech Mech
RAHUL ENTERPRISES
Glacier Cooling Solutions Private Limited
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
Bidder Name
UNIVERSAL ENGINEERING
Glacier Cooling Solutions Private Limited
RAHUL ENTERPRISES
R Tech Mech
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .