Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical MEETING QR |
| 2 | Accepted-Technical NTPC LIMITED EPROCUREMENT PORTAL | Accepted-Technical MEETING QR |
| 3 | Rejected-Technical | Rejected-Technical NOT MEETING QR |
| 4 | Not Admitted-Fee | Not Admitted-Fee Fee not received |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
23 Apr 2026, 2:00 pmClosed
M D CHOUDHURYSR MANAGER
NTPC Green Energy Limited E-3, Main Market Rd,Ecotech-II Greater Noida 201306
CONSTRUCTION OF BOUNDARY WALL AT NGEL BILHAUR SOLAR PV PROJECT IN UTTARPRADESH.
2026_NGEL_106637_1
NTPC/NGEL/9900323021
Open Tender
Serv - Others
Service
90 days
NTPC Green Energy Limited E-3, Main Market Rd, Ecot
As per tender documents
10 documents required · 10 mandatory
₹0
₹1 L
Yes
12 Jun 2026
2 Apr 2026
24 Apr 2026
2 Apr 2026
23 Apr 2026
2 Apr 2026
2 Apr 2026 - 9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 10Pre-case Boundary Wall | |||||
| 10.0001 | Pre-case Boundary wall with the total height of minimum 2850 mm above formation level (Finished ground level in case formation level is less than natural ground level). Upto height of 2000mm, it shall be constructed with pre-stressed precast reinforced cement concrete panels fixed to groves made in pre-stressed precast reinforced cement concrete column and over that for 600mm concertina coil with maximum loop spacing of 125mm. It shall be provided with Y-shaped MS angle. The pre-stressed precast reinforced cement concrete columns shall be provided at spacing not more than 2200mm c/c. The pre-stressed precast reinforced cement concrete
columns foundation shall be minimum 1000mm below finished formation level. The boundary wall panels shall be at least 100m below formation level. The boundary wall columns of minimum
size 200mmX150mm shall be provided with two grooves of minimum size 55mmX50mm, so as to receive boundary wall panels spanning from column to column with minimum width of 300mm and minimum thickness of 50mm as filler wall.
The grade of concrete for all pre-stressed precast panels and column,etc shall be of minimum M30 grade and Grade of foundation block shall be min M25 grade conforming to IS 456. The size of the foundation shall be decided based on the site conditions however the minimum diameter of the foundation shall not be less than 350mm and depth less than1000mm.
Total length of construction of boundary wall is lump sum 1.7 Kms | - | AU | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Policy_for_Debarment_from_Business_DealingsRev4.pdf
Tender Documents • 0.26 MB
SectionVI_TS_Bilhaur_BoundaryWall.pdf
Tender Documents • 1.12 MB
SectionVII_Bilhaur_BoundaryWall.pdf
Tender Documents • 1.49 MB
SectionItoV_Bilhaur_BoundaryWall.pdf
Tender Documents • 12.02 MB
BOQ_109875.xls
BOQ • 0.31 MB
CorrigendumNo1toIFB.pdf
PDF • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .