Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹7.7 L+₹28,200 (3.79%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹9.7 L
EMD Value
₹19,426
Closing Date
25 Mar 2020, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-64/2019-20 SPECIAL REPAIR TO STN ARMOURY AT AFS STN AMBALA
2020_MES_328617_1
GE AF/AMB-64/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE AF AMBALA
₹19,426
Yes
15 Jul 2020
26 Feb 2020
27 Mar 2020
26 Feb 2020
25 Mar 2020
12 Mar 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame) and disposing off
Demolition of plain cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part thereof) complete all as specified and as directed
Dismantling brick tiles or terracing tiles, single layer on roofs, sorting and stacking serviceable tiles and disposing off unserviceable tiles complete all as specified and as directed
Taking down cement or cement lime plaster, any description on brick / concrete / stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed
Taking down cement or cement lime plaster, any description on concrete slabs, soffits of chajjas, etc. including hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed
Taking up or down 15mm bore steel water tubing and connections including cleaning and setting aside for refixing or disposing off, etc. complete all as specified and as directed
Taking up or down 20mm bore steel water tubing and connections including cleaning and setting aside for refixing or disposing off, etc. complete all as specified and as directed
M&L for 75mm thick plain cement concrete 1:3:6 (type C-2) using 20mm graded stone aggregate as in floors, plinth protection, etc. including making spike rolling to surfaces or making impressions of expanded metal whilst the concrete is green laid in alternate bays of 3m length and joints between bays filled with 85/25 grade bitumen and sand mix @ 1:2 complete all as specified and as directed
M&L for plain cement concrete 1:2:4 (type B-0) using 12.5mm graded stone aggregate as in roof kerbs, gola, padding, etc. complete all as specified and as directed
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in bed blocks, etc. including finishing the surface smooth complete all as specified and as directed
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate for bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm dia drain pipes complete all as specified and as directed
M&L for 40mm thick brick tiles laid over and including 15mm thick cement mortar screed in 1:6, jointed and grouted flush in cement mortar 1:3 in roofs complete all as specified and as directed
--ditto-- all as per serial item No. 18 hereinabove but except tiles complete all as specified and as directed Note: Serviceable brick /terracing tiles obtained under serial item No. 9 hereinabove shall be reused in this item
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0kg of cement per square metre complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed
--ditto-- all as per serial item No. 21 but except bricks
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan as in half brick thick walls built in CM (1:4) complete all as specified and as directed
S&F aluminium anodized window shutters and frame with aluminium guard bars, made out of hollow extruded aluminium sections (as detailed below), each shutter having 2Nos. aluminium hinges 100mm long, 1No. lock type aluminium handle 100mm, 2Nos. 150mm long aluminium tower bolts and including 5mm thick tinted glass fixed with glazing clips, rubber beading, gaskets, aluminium beading screws, etc. as required complete all as shown on drawing, as specified and as directed Details: Shutter size - 100x44mm x1.6mm thick Chowkhat size - 100x44mm x1.6mm thick Notes: (i) Drawings shall be referred at GE (AF) Ambala (ii) Minimum thickness of anodisation shall be 15microns
S&F steel window (box type) factory fabricated, double shutter (glazed and wire gauzed) with side hung shutters including pintle type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02Nos for each leaf) duly welded, with glazing bars dovetailed or welded including MS fillets, welding of guard bars with one shop coat of red oxide zinc chrome primer overall complete all as specified and as directed Notes: (i) Windows shall be fabricated as per CE Palam drawing No. TD-219 Sh 1/3 to 3/3 dated 02 Jan 2007 (updated up to date) and these drawings shall be referred at the O/o the GE (AF) Ambala (ii) Glazing, wire gauge, guard bars will be measured and paid separately under respective items herein (iii) Any other sundries, etc. as required at site shall be deemed to be included in the quoted rate
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain / printed coloured PVC sheet (as approved) reinforced with MS square tube all as per specifications and drawing given in SSR Part-I 2009 all as per manufacturer's instructions and making good the disturbed surfaces complete all as specified and as directed
S&F factory made solid panel PVC door shutter, 30mm thick, consisiting of MS frame made out of MS tubes for top and bottom rails, MS frame shall be moulded with plain coloured PVC 'C' channel and having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain coloured PVC sheet top rail, lock rail and bottom rails, paneling of plain coloured PVC sheet to be fitted in MS frame welded / sealed to stiles and rails with suitable PVC sheet beading and jointed together using solvent and fixed in position in frame as per site requirement and specified in MES Schedule 2010 complete all as specified and as directed Door Width Size of style Size of rails exceeding 1.5' but not exceeding 2' 50mm 50mm exceeding 2' but not exceeding 2.5' 50mm 75mm exceeding 2.5' but not exceeding 3' 75mm 100mm exceeding 3' 100mm 125mm
M&L for aluminium anodised (minimum thickness of anodising shall be 15microns), white or tint as approved, grill of design DG-104 pattern (10X5.2mm), fixed with anodised aluminium 'F' sections (20.6x15.2x1mm) to aluminium window / ventilators, etc all as per manufacturer's instructions complete all as specified and as directed
S&F 100mm butt hinges, stainless steel, medium weight with stainless steel hinge pin and fixed complete all as specified and as directed
S&F in repairs 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed
S&F150mm long, aluminium door handles, fabricated type with back plate 3mm thick, complete all as specified and as direct
S&F 250mm aluminium anodised hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F 4mm thick sheet glass, ordinary quality, area not exceeding 0.5sqm in each pane, cut to required size and shape to existing wooden shutters / MS windows / shutters, etc. with glazing clips, glass oil putty, etc including hacking out old broken glass (any thickness), cleaning hacked grooves, removing damaged putty, beads, etc complete all as specified and as directed
M&L for rendering 15mm thick plaster, in cement mortar (1:6) on fair faces of brick masonry / concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed
M&L for rendering 15mm thick in cement mortar 1:4 on brick / concrete surfaces / on masonry walls, mixed with integral water proofing compound @3% by weight of cement content finished even and smooth without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein
M&L for rendering 5mm thick plaster, in cement mortar (1:3) on fair faces of concrete surfaces of soffits of slabs, ceilings, etc. finished even and smooth without using extra cement complete all as specified and as directed
Supply only integral water proofing compound as specified
M&L for rough cast plaster including 15mm thick rendering in CM 1:3 on brickwall or concrete surfaces complete all as specified in SSR Part-I clause 14.22 complete all as specified and as directed Note: Rough cast finish shall be made as under: (i) After applying the under coat of cement mortar 1:3 and while it is still in plasic state the rough cast mixture consisting of crushed stone or fine gravel / aggegates (of size between 6 to 12mm depending on the texture required) mixed with course sand and cement in the ratio of 1:1:1 shall be applied and finished even (ii) The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered
M&L for preparing of new / old wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, tint as approved complete all as specified and as directed
M&L for preparation of new masonry / concrete wall surfaces and applying two coats of oil emulsion distemper over a coat of wall primer including a coat of wall care putty 1mm thick including all necessary staging, scaffolding, safety precautions, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for preparation of old masonry / concrete wall surfaces and applying one coat of oil emulsion distemper including filling up all holes, cracks, etc. dubbing, with putty and all necessary staging, scaffolding, safety precautions, etc. as required to work at heights, etc. complete all as specified and as directed
M&L preparation of newly plastered / unplastered surfaces and applying three coats of white wash on walls complete all as specified and as directed
M&L preparation of newly plastered / unplastered surfaces and applying three coats of white wash on ceilings complete all as specified and as directed
M&L preparation of old plastered / unplastered surfaces and applying one coat of white wash on walls complete all as specified and as directed
M&L preparation of old plastered / unplastered surfaces and applying one coat of white wash on ceilings complete all as specified and as directed
M&L preparation of new / old plastered wall surfaces of and applying two coats of acrylic anti-fungal paint in camouflage pattern (as approved by the GE) over a coat of alkali resistant wall primer as per manufacturer's instructions complete all as specified and as directed
M&L preparation of old plastered wall surfaces of and applying one coat of acrylic anti-fungal paint in camouflage pattern (as approved by the GE) as per manufacturer's instructions complete all as specified and as directed
M&L for framed works such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, drain covers, FOD traps and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.06sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality in floors etc laid over 15mm thick screed bed in CM (1:4) (rate shall be included) set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
M&L for coloured glazed designer ceramic tiles, of size 300x450mm x 6 to 7mm thick of superior quality fixed on vertical surfaces such as skirting / dado / risers of step, etc., fixed over backing coat of 10mm thick plaster in CM (1:4) (rate shall be included) set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles all as specified and as directed
S&F vitreous China bowl urinal flat back half stall of size 465x355x265mm (minimum), white, with grating and union for discharge pipe, including providing fixing plugs, brackets, grating, union and connections to flushing pipe, bedding urinal against wall in CM 1:2, securing bowl with plugs and 60mm long brass screws, pointing around urinal bowl in white cement (excluding flushing cistern, flush pipe and waste pipe), taking down and disposing off old urinal bowl complete all as specified and as directed
S&F in repairs vitreous China wash down water closet pan (Pedestal pattern), 400x550x200mm dimensions, white colour, with 'P' or 'S' trap, including flush pipe, trap, connection to drain or outgoing pipe, anti-syphonic pipe, white seat cover as approved, closed pattern with flat bottom & cover and chromium plated mild steel or aluminum anodized hinge device and jointing and connecting up complete all as specified and as directed
S&F in repairs vitreous China partition, 20mm thick, white, of size 310x700mm fixed with and including suitable stainless steel chromium plated bullet hinges 200mm long, etc. duly gouted in walls complete all as specified and as directed
S&F 10litres capacity PVC flushing tank, syphonic action type, low level, valveless, with PVC inlet ball valve, PVC flush pipe, float, chain and pull and suitable sized brackets including cutting of floor / wall and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing and taking down of old PVC flush tank and disposing off complete all as specified and as directed
S&F wash hand basin, vitreous China, white, flat back type, of size 550x490mm, including CI brackets, cutting for and pinning in ends of brackets with coupling and including PVC connection 60cm key with brass union, fixed as in repairs complete all as specified and as directed
S&F in repairs chromium plated grating of size 125mm including jointing with solvent cement complete all as specified and as directed
S&F in repairs UPVC floor trap with PVC grating suitable for 75mm external dia, type B pipes, including jointing with solvent cement complete all as specified and as directed
S&F in repairs PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement for 110mm external dia type-B pipes complete all as specified and as directed
S&F in repairs 15mm dia bib taps, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered 'HOT'/'COLD', with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed
S&F in repairs 15mm dia stop / anlgle valves, concealed type, chromium plated stainless steel, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm dia stop / anlgle valves, flush type, chromium plated stainless steel, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm PVC connections, 600mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed
S&F in repairs 15mm dia brass chromium plated fancy type, central hole basin mixer without pop-up waste system with 450mm long braided hose complete all as specified and as directed
S&F in repairs stainless steel chromium plated tubular towel rail 'D' type 20mm dia and 600mm long between flanges, minimum weight 190gms, fixed with suitable brackets complete all as specified and as directed
S&F in repairs sheet glass corner shelf assembly consisting of 5.5mm thick sheet glass shelf of size 300x300mm with chromium plated bracket guard and railing 60cm long complete all as specified and as directed
S&F soap dish, cast copper alloy, chromium plated, approximate size 160x160x90mm duly fixed on walls with cadmium plated screws complete all as specified and as directed
S&F in repairs toilet paper holder cast copper alloy chromium plated fixed to walls with cadmium plated brass screws complete all as specified and as directed
S&F in repairs 75mm dia, ivory gold overhead shower with revolving joints and 150mm long swivel shower arm suitable for 15mm bore pipe complete all as specified and as directed
S&F 20mm dia ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F health faucet, telephone type, with CP arms, flexible pipe (ABS body) with 1.0m long PVC tube and wall hook of approved finish complete all as specified and as directed
S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed for the following bores:
Fixing only steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed for the following bores: Note: Serviceable tubings obtained from serial item Nos. 12 & 13 will be reused under this item
M&L for cleaning of internal surfaces of PVC overhead water storage tanks of capacity exceeding 250litres but not exceeding 500litres, including staging (if required), at any position / location, by scrubing the surfaces with the help of coir brush, jute cloth and flushing out all the accumulated mud / silt inside the tank, then applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. and writing tank number, capacity of tank, date of cleaning with white synthetic enamel paint over a black synthetic enemal paint base (of suitable dimensions) with size of letter 4" height complete all as specified and as directed
Supplying, hoisting, fixing and connecting up rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) of capacity 1000litres, hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. and taking down of old tank from any location complete all as specified and as directed
S&F PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints laid in trenches / floors or fixed to walls with suitable clamps, etc. with PVC cowl including necessary staging / scaffolding, etc. as required and taking up/down old pipes and disposing off complete all as specified and as directed
M&L for Atactic Poly Propaneylene (APP) modified bituminous membrane, weight not less than 4.0kg/sqm, reinforced with non-woven polyester fibre @160gm/sqm by torch method as per manufacturer's instructions complete all as specified and as directed Specifications for membrane: (i) Softening point 150oC minimum (ii) Cold flexibility (-)2oC minimum (iii) Single centre core non-woven polyester reinforcement of not less than 160gm/sqm (iv) Tensile strength of 650N/sqcm and 450N/sqcm in longitudinal and transverse directions respectively (v) Minimum elongation of >20% in both directions (vi) Dimensional stability of 1% maximum (vii) Water tightness / impermiable at 2kgf/sqcm (viii) Water absorption of not more than 1% on mass within 24hrs (ix) Overlaps of minimum 100mm on longitudinal direction and 150mm along transverse direction shall be maintained while laying
M&L for earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth strip of size 32x6mm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, dismantling old unserviceable earthing and disposing off complete all as specified and as directed
Notes: (i) The cost of GI earth continuity conductor/wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item
S&F steel water tubing, 40mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed
S&F in repairs air termination, single pointed aluminium rod 12mm dia and 300mm long including suitable insulated base plate and connecting up complete all as specified and as directed
S&F in repairs GI strip of size 25x4mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. complete all as specified and as directed
S&F in repairs aluminium strip of size 25x3mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. complete all as specified and as directed
M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws and taking down and disposing off old terminal block complete all as specified and as directed
Anil jindal and sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .