Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PANCHAYATI RAJ ROHTAK | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance INSIDE SIWANCHI GATE GORIYON KI GALI JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹6.5 L
EMD Value
₹13,000
Closing Date
8 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur- 342011
REPAIR TO ROOF FACIA, RCC PARAPETS, PLASTERING AND POINTING IN MD ACCN IN ZONE-A AT DEFENCE LAB JODHPUR
2022_MES_531091_1
8481/E8
Open Tender
Civil Works
Item Rate
120 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹13,000
Yes
28 Jul 2022
15 Jun 2022
11 Jul 2022
15 Jun 2022
8 Jul 2022
24 Jun 2022
16 Jun 2022 - 23 Jun 2022
60 days
Amount
Demolition of cement concrete in roofs, floors (other than ground floors), beams, staircases, landings, chajjas and similar suspended work
M&L for PCC 1:2:4 type B0 (using 12.50 mm graded aggregate) in roofs , kerbs or mud stops, rounded or chamfered on edges as directed including necessary form work and maintain the proper slope of roof surface etc complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick screed bed or bedding layer in CM 1:4 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etccomplete all as specified and directed by Engineer-in-Charge.
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following -
(a) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.25 kg/Sqm on top of dry surface of finished cement mortar plaster.
(b) One layer of APP based polymeric water proofing membrane of weight not less than 3.5 kg/Sqm consisting 3mm thick reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminious primer . Application of APP membrane over primer shall be done by torch application.The overlap shall be minimum 100 mm on the traverse direction and 75 mm on longitudinal direction and the over lap shall be sealed by flame.
M&L 20mm thick screed bed/bedding layer in CM 1:4 on concrete surface/top most surface layer of roof treatment , finished even and smooth without using extra cement mixed with water proofing compound as per manufacturer's instructions. (Note:- WPC shall measured and paid seperately)
Supply only Liquid water proofing compound.
M&L for laying Endura cool roof SRI tiles of size 300x300x10mm thick approved colour,joints grouted & flush pointed in cement mortar(1:3) complete all as specified & directed by Engineer-in-charge. (Make: Johnson or equivalent in Orient bell/Kajaria/sun heart.)
Taking down of cement or cement plaster work any description from brick or stone wall etc including roof facia, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work/stone or concrete surfaces including roof facia and finishing the surface even and smooth without using extra cement incl WPC complete all as specified and directed by Engineer-in-charge. (Note:-Water proofing compound should be measured and paid separately under item Sch'A')
M&L for preparing newly plastered/unplastered or previously untreated walls surfaces and applying two coats of cement base paint over one coat of primer on plastered surfaces, complete all as specified and directed by Engineer-in-charge.
M&L preparation of old plastered or unplastered surfaces of external wall including brooming down with steel wire brushing and applying two coat of cement base paint on external wall complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking out existing PVC water storage tanks of capacity not exceeding 500 liter and removal from existing platform to facilitate execution of roof treatment and re-fix the same in position after completion of treatment work complete, and reconnecting with existing GI pipe line complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking out existing PVC water storage tanks of capacity not exceeding 1000 liter and removal from existing platform to facilitate execution of roof treatment and re-fix the same in position after completion of treatment work complete, and reconnecting with existing GI pipe line complete all as specified and directed by Engineer-in-charge.
Dismantling of old unserviceable PVC water tank of exc 250 and not exc 500 Ltrs capacity and removing to store complete all as specified and directed by Engineer-in-charge.
S&F 500 ltrs capacity rotational moulded polythene water storage tank white colour tripple layered (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including 20mm PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms complete all as specified and directed by Engineer-in-charge.
Dismantling of old unserviceable PVC water tank of exc 500 and not exc 1000 Ltrs capacity and removing to store complete all as specified and directed by Engineer-in-charge.
S&F 1000 ltrs capacity rotational moulded polythene water storage tanks white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including 20mm PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms complete all as specified and directed by Engineer-in-charge.
S&F in repair 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc including taking down complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc including taking down complete all as specified and directed by Engineer-in-charge.
S&F in repair gun globe or gate valve for 20 mm bore pipe with iron wheel head,screwed both ends for iron pipe complete all as specified and directed by Engineer-in-charge.
Taking down eves gutter and rain water pipes (any size or pattern), including all fittings, head shoes, bends, swan-necks atc., incl cleaning or refixing or removal to store (mesured overall as fixed along the centre line over fittings the accessories) complete all as specified and directed by Engineer-in-charge.
S & F PVC (SWR) pipes of 110 mm dia standard quality, single socketed, in any length with rubber ring joints and all fittings clamps etc; fixed on walls complete all as specified and directed by Engineer-in-charge.
All as iten No-23 above but except pipes complete all as specified and directed by Engineer-in-charge.
S & F PVC (SWR) plain bends/ shoes of any radius 110 mm dia, including jointing with solvent cement and finished/ filling with PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) as required complete all as specified and directed by Engineer-in-charge.
Demolition of Re-inforced Cement Concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed by Engineer-in-charge.
M&L RCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in slab and shelves/staging of tank supported on walls complete all as specified and directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-charge.
M&L for mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips (for stirupps) complete all as specified and directed by Engineer-in-charge.
M&L for use and waste of formwork to soffits of RCC Shelves and similar works not exc. 200 mm thick horizontal or slopping in rough finished flat surface of concrete complete all as specified and directed by Engineer-in-charge.
M&L for use and waste of formwork to edges of RCC Shelves or similar work thickness exc. 05 cm and not exc. 10 cm in rough finished surfaces of concrete complete all as specified and directed by Engineer-in-charge.
vinayandsons
J AND T Enterprises
HOODA CONSTRUCTION COMPANY
O P Gehlot
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .