13 Dec 2019, 6:00 pmClosed
GE I CG PORBANDAR
GE I CG PORBANDAR DHQ NO 1 CG PORBANDAR
IMPROVEMENT OF TEXI TRACK LIGHTS SECURITY LIGHTS AT ICGAE AND REPLACEMENT OF SECURITY LIGHT WITH LED LIGHTS AT DHQ NO 1 AND REPLACEMENT OF PUMP SETS WATER COOLERS ACS IN ICGAE UNDER GE I CG PORBANDAR
2019_MES_292272_2
8455/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PORBANDAR
PLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹94,000
Yes
17 Jan 2020
18 Nov 2019
14 Dec 2019
18 Nov 2019
13 Dec 2019
21 Nov 2019
Amount
SCHEDULE 'A'
S&F Octoganal Hot Dip galvanised steel light poles including juction box of height 5 mtrs with , top dia 70 mm, bottom dia 130 mm sheet thickness 3 mm, base plate 200 x 200 x 12 mm, foundation nuts '&' bolts including excavation and earth work, reinforced cement concreate foundation, as per manufacturers design and hot dipped galvanised bracket Double arm decorative type for fixing of street light and one number of MCB 6Amps including 25 Amp four way terminal block, complete all as specified and as directed Make: Bajaj/ Surya/ Utkarsh /CG/Wipro
S&F Octoganal Hot Dip galvanised steel light poles including juction box of height 7 mtrs with , top dia 70 mm, bottom dia 130 mm sheet thickness 3 mm, base plate 200 x 200 x 12 mm, foundation nuts '&' bolts including excavation and earth work, reinforced cement concreate foundation, as per manufacturers design and hot dipped galvanised bracket Double arm decorative type for fixing of street light and one number of MCB 6Amps including 25 Amp four way terminal block, complete all as specified and as directed Make: Bajaj/ Surya/ Utkarsh /CG/Wipro
M&L XLPE Cable insulated screened PVC bedded galvanised steel strip or wire armoured, elctric cable, heavy duty, 1100 volts grade with stranded aluminium conductors of size 16 Sqmm x 4 core, all as specified. Make :- Havells/RR Cable/Polycab/M/s Ravin
Taking up existing under ground cable of size 16 sqmm x 4 core from trenches and stacking neatly for further disposal all as directed by Engineer -in -Charge
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m in depth and getting out in soft soil, complete all as specified and as directed.
Returning filling in incl. spreading levelling watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified.
Supply and lay 63 mm outer dia double wall corrugated ( DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirmings to IS 14930 (PartI & II) including all accessories like coupler, bends tees etc., for protection of underground cables laid in trenches/ road/ nallah or fixed alongwith wall, poles or laid under floor all as specified. Make: REX/Poly/ Gemini.
Cutting existing bitumionous road/cencrete road/ Hard standing with paver blocks etc., to required width good and depth for laying underground cables and making good with back filling and concreting of thickness 150mm PCC type B, (1:2:4, using 20mm graded stone aggregate)/making good disturbed hard standing with paver blocks, all as directed by Engineer-in-Charge.
M & L Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level, connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 of SSR Part-I, including provision of earth pit all as specified to the earthing test point all as specified and indicated including testing on completion including provision of earth pit all as specified Note:- (i) Cost of earth strip and GI pipe for proteciton of earth strip deemed to be included in unit rate up to 7.5 meter. (ii) Earth resistance value should be less than 4 Ohms.
S & F LED Flood light, high pressure, dia cast aluminium housing, IP 66, Nominal Lumen output 12000lm PF>0.95 operating voltage 120-270AC 50 HZ inclduing connector to fitting with 3 core 2.5 Sqmm PVC insulated copper cable from junction box to fitting complete all as specified and as directed. Make:- Philips/ Wipro/ OSRAM/Orient.
S&F Automatic street light swith 415 Volts 3 phase 5 KW with contactor fitted in stainless steel enclosure inclduing incoming and outgoing MCBs, power contactor complete 3 phase circuit board along with nutral switch fixed in repaircomplete all as specified and as directed. Make:- Nature Switch :- Bajaj/Healer/Kakatiya. MCB/Contactor : - L&T/C&S/ABB
S&F LED street lights fitting, nominal watts 70 Watt, Lumen efficiency minimum 90 lumens/ watt, pressure die cast aluminium housing, 140 to 270 Volts, 50 HZ PF>0.95, mounted on octogonal hot dip galvanised street light poles including 3 core 1 Sqmm PVC insulated copper cable, from Junction box to fitting, complete in repair, all as specified and as directed. Make:- GE/OSRAM/ORIENT/WIPRO.
S&F LED street light fitting, nominal wattage 36 Watt Lumen efficiency minimum 70 lumens/ watt pressure die cast aluminium housing, 140 to 270 Volt, 50 HZ, PF>0.95, mounted on poles including 3 core 1 Sqmm PVC insulated copper cable from control box to fitting complete in repair all as specified and as directed. Make:- GE/OSRAM/ORIENT/WIPRO.
S&F Multiple outlet box with 4 pole Plug in box with 100 Amps MCCB rating with backup protection with MCCBs, modular and compact construction, loop in loop out facitlites, higher degree of ingress protection , 7 tank processed powder coated enclosure,PU gasketing for sealing against dust and water, complete with all fixing accessories such as washers fixed in repair , nuts, bolts, clamps etc required at site complete all as specifed and as directed. Make BCH Electric Ltd cat No PR 63 MCCB-2-LILD or equivalent from C&S/Adhunik. Note : Fixing directions as per manufacturers instructionsshall be followed.
Dismantling of old concreate poles and removing from site to out side defence land complete all as specified and as directed
S & F LED taxiway medium intensity Omni- directional,elevated light with one watt LED for operation at 6.6 amps, series circut with an integrated encapsulated electonic module , with Die-cast aluminium alloy frangible body finished with stove enamel aviation yellow with stainless steel hardware with lens of heat resistant and thermal shock presed glass provided with heat and weather resistant neoprene rubber gasket, equiped with a 14" long secondary lead as per FAA L-823, mounted on a breakable coupling, conforming IS 7785 Part I - V, including blue lens and CI base plate, fixed in repairs by replcing 45 watt halogen fixture. Make:- AMA or equivalent as approved by GE.
Supply and laying 50/38 mm double wall corrugated high density polyethylene pipe confirming to IS:-14930 Part II with amendments with accessories like coupler, bend, tee etc in the trench or fixed on wall as per site requirement in repair all as directed by Engineer-in-charge.
Supply and lay of 50/38 mm double wall corrugated high density polyethylene pipe confirming to IS:-14930 Part II with amendments, with accessories like coupler, bend, tee etc, in the shoulder/taxiway surface or GLF work including machine cutting to suitable width and upto 150mm deep,& making good the same by concreting wherever required as per site requirement all as directed by Engineer-in-charge.
Supply, lay and test XLPE insulated 1 x 6 sqmm (7 strand) 5KV grade copper conductor, PVC sheathed, single core, copper tape screened AFL cable in repair all as specified. Make :- Havells/KAPCAB/Polycab/or finolex/approved by GE. Note :- Cost of 6 sqmm plug and receptacle of type I , connector deemed to be included in unit rate.
Supply,testing and commissioning of centrifugal pump set of discharge capacity 900 LPM at 36 mtr head, coupled with electric motor of suitable capacity, 3 phase 415 volt 50 hz mounted on MS channel/common base plate and fixed with suitable bolts, grounded in PCC foundation , 30 cm above floor level including PVC conduit for connection from starter to motor terminal, including the following accessories. Make pump and motor Kirloskar/crompton. (i) foot valve (make Kirloskar/venus)- 01 nos of size suitable for suction of pump (ii) gun metal butterfly gate valve- 01 No, of size suitable for delievery of pump (iii) flanged GI medium grade suction pipe of dia as spd by manufacturer to a length not more than 9 m (iv) delievery pipes GI medium grade of dia as spd by manufacturer to a lenght not more than 6 m (v) burden type pressure gauge on delievery of pump set (vi) 20 mm GI pipe line for primming (vii) 20mm gunmetal gate valve (primming valve)- 01 Nos. Make:- Mather Platt/Jyoti/Kirloskar
Supply , installation , commissioning of water cooler fully stainless steel, electric driven single phase having nominal cooling and approx storage capacity 40/80 ltr complete all as spd and directed. Make:- Voltas/Carrirer/Bluestar/Usha
Supply install and testing split units indoor/outdoor complete with cordless remote control unit, Inverter type, copper condenser , minimum 4 star rating, EER not less than 4.5 capacity 1.5 ton, with wall mounted bracket, for installation of outdoor unit, including refrigerant tubing with insulating sleeves, drain pipe and accessories, including removal of existing BER AC window type from site and deposit to MES store and close the opening with 12mm thick prelaminated particle board complete all as spd and directed. Make:- Voltas/Carrier/Hitachi
S&F 20A power unit 4 module plate, 20A starter 20A socket, plug complete all as specified and directed by Engineer-in-charge. Make :- C&S/Legrand ABB
K K Construction Co
DARSHAN CONSTRUCTION Co.
Electricals India
M/s Matadeen Ramchandra Agarwal
VIJAY CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .