EX. ENGINEER (ELECT)-IV/KBZ
OFFICE OF THE EXECUTIVE ENGINEER (ELECT)/ KBZ TOURIST CAMP SITE J.L. NEHRU MARG, NEW DELHI 110002.
Development work at Panchkuian Crematorium Sub head Provision of EI, Fans and other allied electrical works at Panchkuian Crematorium under Karol Bagh Zone
2023_MCD_160573_1
MCD/TR/1950/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
Karol Bagh, PAHAR GANJ
4 documents required · 4 mandatory
₹590
₹15,103
21 Aug 2023
10 Jul 2023
18 Jul 2023
10 Jul 2023
17 Jul 2023
11 Jul 2023
Amount
SR & AR items
OD6618/2022-2023:Supply of 18" (450mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter,blades etc as required
OD6625/2022-2023:P/F ABC(Alluminium phosphate) Power type fire extinguisher 6 Kg capacity complete in all respect with ISI mark i/c fixing arrangement etc complete as reqd.
OD6631/2022-2023:S&F of 32mm dia GI pipe (medium class) 1Mtr long bracket i/c clamp with nut bolt and wiring with 2x2.5sqmm copper conductor single core wire etc as required
121.1:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD3705/2023-2024:DSR 2022 7.7.1 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
OD3706/2023-2024:DSR 2022 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
OD3707/2023-2024:DSR 2022 2.18 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
OD3708/2023-2024:DSR 2022 2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD3709/2023-2024:DSR 2022 2.10.2 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural
OD3710/2023-2024:DSR 2022 2.10.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD3711/2023-2024:DSR 2022 2.3.1 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 6 way, Double door
OD3712/2023-2024:DSR 2022 2.2.13 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp, 30 KA, FPMCCB
OD3713/2023-2024:DSR 2022 1.50.1 Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. Upto 450 mm sweep
OD3715/2023-2024:DSR 2022 1.20.1 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm
OD3718/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
OD3719/2023-2024:DSR 2022 1.7.9 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
OD3720/2023-2024:DSR 2022 1.7.4 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
OD3722/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
OD3723/2023-2024:DSR 2022 5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD3724/2023-2024:DSR 2022 14.16.1.a Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
OD3725/2023-2024:DSR 2022 7.6.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
OD3726/2023-2024:DSR 2022 7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
OD3727/2023-2024:DSR 2022 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
OD3732/2023-2024:DSR 2022 1.7.3 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2x4 sq.mm + 1x4 sq.mm earth wire
OD3746/2023-2024:SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/outgoing cables/bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N).
Civil item
10.18:Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing .
app items
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.1.30:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm
122.2.37:S/I/T/C of Recess mounting CRCA housing 36W LED luminaire with acrylic cover diffuser with following specifications including fixing on existing wall/surface with connections as reqd.(a)Total system wattage = 36 watt +/- 5% (b)Luminus efficacy >=95 lumens /watt. (c)Power factor >=0.95
122.2.111:supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged)
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.34:SITC of 70/72W LED Street Light luminaire fitted with lens, top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =70/72 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
G D Electricals
CANTILEVER ENGINEERS
Bidder Name
G D Electricals
CANTILEVER ENGINEERS
KAFIL ELCTRICAL WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .