Executive Engineer,Streetlight department,VMC,Vadodara
DESIGN, ENGINEERING, SUPPLY AND PROCUREMENT, ERECTION, TESTING, COMMISSIONING AND COMPREHENSIVE OPERATION AND MAINTENANCE FOR A PERIOD OF TEN YEARS FOR SOLAR ROOF TOP POWER PLANT AT CITY CONTROL and COMMAND CENTRE BADAMDIBAUG.
300723
VMC/SL/SETC/SOLAR/2026-27
Open
Electrical
Vadodara
3 documents required · 3 mandatory
₹4,000
Municipal Commissioner, Vadodara Municipal Corporation, Vadodara
₹60,000
3 May 2026
3 May 2026
3 May 2026
20 May 2026
3 May 2026
NAME OF WORK : Providing and Erecting of Solar Roof Top Power Plant at City Control & Command Centre Badamdibaug with comprehensive
O&M Work for 10 years.
CAPEX WORK (WITHOUT GST RATES)
ITEM DESCRIPTION RATE (Rs.) PER TOTAL AMOUNT
ITEM DESCRIPTION RATE (Rs.) PER TOTAL AMOUNT
Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar
Power Plant with Solar Panels (ALMM approved): Frame Material :
Anodized Aluminum alloy Frame With Twin Wall Profile, Front Cover : High
Transmission Low-Iron Tempered Glass (AR Coated), High efficency and
positive power tolerance Pmax: 0/+5, Module Efficiency should be
approx. 19.5%-22%, Normal operating temperature 45'C, Junction Box with
Waterproof IP67 & MC4 Compatible and Enclosed with Bypass
diodes, 100% Electroluminescence test to ensure error free Modules, Thep.
temp. co-efficient of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill factor 75% to be
used. Unit Production:- More than 4.5 Unit /kw /day (Actual)(1Year Avg)
With 10 year Product warranty and 25 year Linear Power Warranty includes
all mechanical and electrical parameters of the Solar panel. Modules
must be complied to the DCR(Domestic content requirements). The Ration
of AC to DC is 5:6 for the Installation capacity which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency: 97.5% -
98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤ 4000, O/p Power
Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -25~60°C,
Integrated protection of Inverter are Anti- islanding Protection, Input
Reverse Polarity Protection, Insulation Resistor Detection, Ground fault
protection, Residual Current Monitoring Unit, Output Over Current
Protection, Output Short Circuit Protection, Output Over Voltage Protection,
PV array string fault Protection. Protection Degree: IP65, User Interface LCD &
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor
Detection Integrated, Residual Current Monitoring Unit Integrated, Output
Over Current Protection Integrated, Output Short Circuit Protection
Integrated, Output Over Voltage Protection Integrated, Protection Degree:
IP65, User Interface LCD & APP,Datalogger & Communication: GPRS /
Wi-Fi, Module Mounting Structure: The mounting (Rectangular pipe /
square pipe / circular pipe) with requisite cross bars, nuts and bolts, etc. shall
be Hot deep galvanized with minimum 80micron coating. The Rectangular /
square /circular hollow pipe section used for the structure should have a
minimum thickness of 2.0 mm. other than above, the material thickness
should be minimum 2.5 mm. A certificate of a structural engineer certifying
the strength and stability of the mounting structure to withstand the weight and
wind speed of 150 km/hour throughout the life span of 25 years of the system,
shall be submitted by the vendors. Hot Dipped Galvanized steel coils.
suitable arrangement for base plate for foundation , solar panel
mounting, the structure should be suitable for carry the load of solar
panel,wiring, sprinkler system etc. with necessary foundation work/wall
mount, j bolt, anchor fastner etc. the nut bolt used for installtion of
stucture should be (SS 304) quality.The ground clearance of the bottom
most edge of solar panel shall not be less than 300 mm to 1200 mm or as
per site’s technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM
Balane of System with necessary Swichgears (Suitabel size and protection of
ACDB & DCDB), inter connecting wiring, earthing system as per the CEIG
drawing approval, lightining arrester system as per the CEIG drawing approval,
all liasoning work with various gov. dipartment like state nodal agency, DISCOM
& CEIG is included in
(Excluding All charges namely GEDA Application fees, Solar connectivity
Charges, Meter connectivity Charges, Meter testing Charges and system
stability/strenthning
50 1 Grid Tied Solar Power System: 26 - 50 kW (3 - phase) 41739 per KW
2 2 Providing & Erecting HT Bidirectional meter as per MGVCL Norms. 15750 Each
1 3 Providing & Erecting LT Solar meter as per MGVCL Norms. 5040 Each
3 4 Providing & Erecting GPRS MODEM as per MGVCL Norms. 9450 Each
9 5 Providing & Erecting LT CT of 100/5 A as per MGVCL Norms. 1155 Each
Providing & Erecting Prewired with 3 TTB SMC (Sintex ) Enclosure with Fabricated
Metal Stand For HT BD Meter & Modem
OPEX WORK (WITHOUT GST RATES)
50 4 Operation and Maintanace work of Solar Roof Top Power Plant for 1st year 1356 per KW
50 5 Operation and Maintanace work of Solar Roof Top Power Plant for 2nd year 1397 per KW
50 6 Operation and Maintanace work of Solar Roof Top Power Plant for 3rd year 1438 per KW
50 7 Operation and Maintanace work of Solar Roof Top Power Plant for 4th year 1481 per KW
50 8 Operation and Maintanace work of Solar Roof Top Power Plant for 5th year 1526 per KW
50 9 Operation and Maintanace work of Solar Roof Top Power Plant for 6th year 1572 per KW
50 10 Operation and Maintanace work of Solar Roof Top Power Plant for 7th year 1619 per KW
50 11 Operation and Maintanace work of Solar Roof Top Power Plant for 8th year 1668 per KW
50 12 Operation and Maintanace work of Solar Roof Top Power Plant for 9th year 1718 per KW
50 13 Operation and Maintanace work of Solar Roof Top Power Plant for 10th year 1769 per KW