Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.8 L+₹6,192.53 (0.30%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.2 L+₹1.4 L (6.76%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹22.0 L+₹1.3 L (6.07%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹20.9 L
EMD Value
₹50,000
Closing Date
8 Sept 2025, 6:00 pmClosed
Executive Engineer
PWD ELECTRICAL DIVISION KOZHIKODE
DEPOSIT Government Medical College Manathavady Conversion of Multipurpose block , Old Block and Nursing college Buildings in to Class room Lab and Library Installation of Air conditioner in Lecturer Halls General Electrical Work
2025_PWD_791616_1
PWD/BLDG/7586/2025-2026
Open Tender
Electrical Works
Item Rate
Manathavady
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
8 Oct 2025
27 Aug 2025
11 Sept 2025
27 Aug 2025
8 Sept 2025
27 Aug 2025
Amount
Installation of Air conditioner
OD38393/2025-2026:Supply Installation, Testing and Commissioning of cassette type ceiling suspended type split air conditioner unit of the following ratings conforming to relevant IS suitable for operating on 415V, 50Hz three phase AC supply, filled with R-410 A refrigerant gas, high energy efficient, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity including refrigerant, copper piping 3m with insulation, control cable up to 5m, 3 m drain pipe, microprocessor control with cordless remote control etc. with one year 4 Nos free service. 4 TR 3 phase cassette typer type split A.C unit, ( LG/ Carrier / equivallent reputed make having similar properties)
OD115914/2025-2026:Supply Installation, Testing and Commissioning of cassette type ceiling suspended type split air conditioner unit of the following ratings conforming to relevant IS suitable for operating on 415V, 50Hz three phase AC supply, filled with R-410 A refrigerant gas, high energy efficient, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity including refrigerant, copper piping 3m with insulation, control cable up to 5m, 3 m drain pipe, microprocessor control with cordless remote control etc. with one year 4 Nos free service. 3 TR 3 phase cassette typer type split A.C unit, ( LG/ Carrier / equivallent reputed make having similar properties)
OD42143/2025-2026:Supply and fixing of Factory made Heavy Duty Bracket for fixing Outdoor unit stand for 4.0 TR AC.
4.1.2:Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
OD42185/2025-2026:Supply & laying of Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ19.1 Copper piping(16G/19G) between Indoor & Outdoor units covered with suitable Class O Nitrile Rubber Insulation 13/19 mm thick and Supported with suitable clamps and fittings..
OD44605/2025-2026:Supply and fixing of 25mm 10Kg/cm2 PVC drain water pipe line with necessary, supports, saddles, clamps -and fittings such as bends, tees etc. are required.
2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.23:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
OD44736/2025-2026:Supply and fixing 4P sheet enclossure on surface / recess along with 40 to 63A , 415V 'C' curve TPN.
OD44891/2025-2026:Supply, Conveyance and fixing charges of 2400 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, in the existing opening of false ceiling, giving connections with the existing wire etc., as required. )
OD48307/2025-2026:conveyance, installation, testing and commissioning of Existing recess mounting indoor LED down lighter 24 W, (100lm/W) recess mounting square/round down light fittings of approved make ,which provides soft-light and glare free symmetrical illumination and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
1.1.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
OD120954/2025-2026:Supply, conveyance, installation, testing and commissioning of inverter type wall mounting split AC unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz, single phase AC supply filled with R - 410A refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc. of following capacity including refrigerant copper piping 3mtr with insulation, control cable up to 5mtr, 3m drain pipe, microprocessor control with cordless remote control etc. - 2 TR 1 phase 5 star rated inverter type split AC unit with three year free service etc. as required ( Blue star /LG/Daikin/Mitsubishi/ Carrier )
OD120959/2025-2026:Supply and providing 5KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and output range of 210-240V
SOUBHAGYA ENGINEERING COMPANY (BID ID -2319688)
All Star Electricals (BID ID -2326611)
POURNAMI (BID ID -2322182)
Bidder Name
SOUBHAGYA ENGINEERING COMPANY
seasoncontrol
All Star Electricals
POURNAMI
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1305735.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .