Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹24.1 L+₹14,700.80 (0.61%)Rejected-Finance 589 BC BAZAR AMBALA CANTT AMBALA | L2 | Rejected-Finance not lowest bidder | |
| 3 | L3₹28.2 L+₹4.2 L (17.4%)Rejected-Finance | L3 | Rejected-Finance not lowest bidder | |
| 4 | L4₹30.9 L+₹6.9 L (28.6%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-Finance not lowest bidder | |
| 5 | L5₹33.8 L+₹9.8 L (40.8%)Rejected-Finance 12 53 CHOPASNI HOUSING BOARD JODHPUR 342008 | JODHPUR | RAJASTHAN | 342008 | L5 | Rejected-Finance not lowest bidder |
| Sl No | Description | Qty | Unit | Surendra Singh L1 | VARDHMAN SALES CORPORATION L2 | Shri Electrical Enterprises L4 | BHAKAR RAM AND SONS L3 | PANKAJ ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Taking out window/Split type AC of capacity up to 2 Ton from the site for servicing, cleaning with air blower of fins, cleaning of condensing unit, cooling coil and evaporative coil with caustic soda mix water,taking out all dirt/sludge etc. by using pressure pump ,cleaning of air filter incl. Oiling and greasing of condensing fan motor, Replacement of remote cell/battery replacing worn out rubber,bushes/rubber packing rectification of unusual noise. Replacement of minor parts such as nut/bolts,washers etc and reassembly of complete AC unit and testing complete for smooth functioning to entire satisfaction complete all as specified. | 80 | Each | 600 ₹48,000 | 187 ₹14,960 Lowest | 800 ₹64,000 | 500 ₹40,000 | 600 ₹48,000 |
| 2.00 | M&L for complete Gas charging as per the existing refrigerant up to the required level and replace NRV for window/Split type AC of capacity 1.5/2 Ton complete all as specified. | 80 | Each | 1,200 ₹96,000 | 375 ₹30,000 Lowest | 1,500 ₹1,20,000 | 1,200 ₹96,000 | 2,000 ₹1,60,000 |
| 3.00 | M&L for Taking out defective compressor Sealed Rotary / Reciprocating unit of window AC of cap 1.5 Ton incl.cutting of copper tubing without any damage to existing other parts and Material and labour for replacement of compressor/ sealed unit complete with erection of compressor in same location with suitable base,jointing of copper refrigerant pipe line,charging of gas to required level,leakage testing,NRV etc. including testing for smooth functioning. NOTE : (i)The rate quoted by the contractor shall be inclusive of all charges like transportation,fittings,etc. complete with necessary guarantee period including oiling and environment friendly gas charging , testing etc complete all as specified. | 2 | Each | 5,500 ₹11,000 Lowest | 11,060 ₹22,120 | 9,000 ₹18,000 | 9,000 ₹18,000 | 8,000 ₹16,000 |
| 4.00 | All as per ser No 3.00 above but split type AC of cap 1.5 Ton complete all as specified. | 20 | Each | 7,000 ₹1,40,000 | 11,060 ₹2,21,200 | 8,300 ₹1,66,000 | 7,500 ₹1,50,000 | 6,500 ₹1,30,000 Lowest |
| 5.00 | All as per ser No 3.00 above but split type AC of cap 2 Ton complete all as specified. | 10 | Each | 9,000 ₹90,000 | 11,435 ₹1,14,350 | 10,000 ₹1,00,000 | 9,000 ₹90,000 | 8,000 ₹80,000 Lowest |
| 6.00 | M&L for replacement of blower bush of split type AC having capacities of 1.5/2 Ton complete all as per the sample existing at the ground complete all as specified. | 50 | Each | 50 ₹2,500 Lowest | 94 ₹4,700 | 200 ₹10,000 | 95 ₹4,750 | 50 ₹2,500 Lowest |
| 7.00 | Supply and fix in repair blower fan motor of suitable size for indoor type split AC of cap 1.5/2 Ton complete all as specified. | 25 | Each | 550 ₹13,750 | 281 ₹7,025 Lowest | 1,300 ₹32,500 | 700 ₹17,500 | 1,500 ₹37,500 |
| 8.00 | Supply and fix in repair condensor fan motor suitable for split AC of capacity 1.5/2 Ton complete all as specified. | 30 | Each | 450 ₹13,500 | 281 ₹8,430 Lowest | 1,200 ₹36,000 | 600 ₹18,000 | 2,200 ₹66,000 |
| 9.00 | M&L for taking out u/s blower of window type AC of cap 1.5/2.00 ton and supply and fix blower of approved make suitable for existing window type AC of cap 1.5/2.00 Ton complete all as specified. | 2 | Each | 1,000 ₹2,000 | 421.5 ₹843 Lowest | 500 ₹1,000 | 900 ₹1,800 | 2,500 ₹5,000 |
| 10.00 | S & F in replacement wiring kit complete suitable for split type AC 1.5/2 Ton capacity complete with lugs, thimbles and selector switch complete all as specified. | 30 | Each | 150 ₹4,500 Lowest | 750 ₹22,500 | 900 ₹27,000 | 1,700 ₹51,000 | 500 ₹15,000 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
19 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR AND REPLACEMENT OF DIFFERENT TYPES OF SUMMER WINTER APPLICANCES IN OTM AND MD ACCN AT A A BANAR UNDER GE BANAR
2025_MES_713034_3
8825/21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BANAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Banar
₹70,000
Yes
17 Oct 2025
29 Aug 2025
26 Sept 2025
29 Aug 2025
19 Sept 2025
5 Sept 2025
Amount
M&L for Taking out window/Split type AC of capacity up to 2 Ton from the site for servicing, cleaning with air blower of fins, cleaning of condensing unit, cooling coil and evaporative coil with caustic soda mix water,taking out all dirt/sludge etc. by using pressure pump ,cleaning of air filter incl. Oiling and greasing of condensing fan motor, Replacement of remote cell/battery replacing worn out rubber,bushes/rubber packing rectification of unusual noise. Replacement of minor parts such as nut/bolts,washers etc and reassembly of complete AC unit and testing complete for smooth functioning to entire satisfaction complete all as specified.
M&L for complete Gas charging as per the existing refrigerant up to the required level and replace NRV for window/Split type AC of capacity 1.5/2 Ton complete all as specified.
M&L for Taking out defective compressor Sealed Rotary / Reciprocating unit of window AC of cap 1.5 Ton incl.cutting of copper tubing without any damage to existing other parts and Material and labour for replacement of compressor/ sealed unit complete with erection of compressor in same location with suitable base,jointing of copper refrigerant pipe line,charging of gas to required level,leakage testing,NRV etc. including testing for smooth functioning. NOTE : (i)The rate quoted by the contractor shall be inclusive of all charges like transportation,fittings,etc. complete with necessary guarantee period including oiling and environment friendly gas charging , testing etc complete all as specified.
All as per ser No 3.00 above but split type AC of cap 1.5 Ton complete all as specified.
All as per ser No 3.00 above but split type AC of cap 2 Ton complete all as specified.
M&L for replacement of blower bush of split type AC having capacities of 1.5/2 Ton complete all as per the sample existing at the ground complete all as specified.
Supply and fix in repair blower fan motor of suitable size for indoor type split AC of cap 1.5/2 Ton complete all as specified.
Supply and fix in repair condensor fan motor suitable for split AC of capacity 1.5/2 Ton complete all as specified.
M&L for taking out u/s blower of window type AC of cap 1.5/2.00 ton and supply and fix blower of approved make suitable for existing window type AC of cap 1.5/2.00 Ton complete all as specified.
S&F in replacement of running capacitor, 45/60 mfd suitable for 1.5 /2 Ton capacity window/split type AC of approved make complete all as specified.
S & F capacitor 6/10 mfd suitable for split / window type AC.
M & L for replacement of PCB control kit suitable for window/split type AC of capacity 1.5/ 2 Ton complete all as specified.
Takingdown indoor & outdoor unit of 1.5/2TR split Ac and refix again existing/another place complete all as specified.
S&F in replacement of Thermostat (Thermal sensing bulb) suitable for split/window type AC 1.5 /2 Ton capacity of approved make complete all as specified.
S&F in replacement of contactor relay suitable for window/ split type AC 1.5/2 Ton capacity of approved make complete all as specified.
S&F in replacement of over load protection relay suitable for window/ split type AC 1.5 /2 Ton capacity of approved make complete all as specified.
Supply and fix in replacement of condensing coil of window type AC of capacity 1.5 Ton complete all as specified.
Supply and fix in replacement evaporating coil of window type AC of capacity 1.5/2 Ton complete all as specified.
Supply and fix in replacement of evaporating coil of split type AC of capacity 1.5 /2 Ton complete all as specified.
Supply and fix in replacement of condensing coil unit complete of out door unit of split type AC of capacity 1.5/2 Ton with approved make complete all as specified.
M & L for replacement of chocked copper tube of size 1/4" of split type AC 1.5/2 ton cap complete all as specified.
M & L for replacement of chocked copper tube of size 1/2" of split type AC of 1.5 /2 ton cap complete all as specified.
M & L for insulation coating made of foam rubber circular dia to copper tube to upkeep the required temperture and over all protection to copper tubing of size 1/4" or 1/2" complete all as specified.
M & L for taking out water Cooler from site of any capacity and make for servicing incl. cleaning of cooling tank and condensing coil with C sine chemical mixed water, taking out all dirt , sludge deposited, incl. oiling / greasing of condensing fan motor rectification of unusual noise, replacement of minor parts such as nut/bolt washers etc as directed with writing of serial No SM/MES No. and re installed the water cooler in position complete all as specified.
M&L for complete Gas charging as per the existing refrigerant up to the required level and replace NRV for water cooler 40/80 ltr complete all as specified.
M&L for Taking out defective sealed compressor unit of 40/80 Ltr/hr cap of water cooler and M & L for replacement for sealed compressor unit of suitable for water cooler of 40/80 lit/hr cap , reassembly and testing complete as to the entire satisfaction complete all as specified.
M&L for Taking out defective sealed compressor unit of 60/120 Ltr/hr cap of water cooler and M & L for replacement for sealed compressor unit of suitable for water cooler of 60/120 lit/hr cap , reassembly and testing complete as to the entire satisfaction complete all as specified.
M & L for finding out leakage of condensor/ cooling unit of water cooler of 40/80 Ltr cap including dismantling the same for recharging and stop leakage by brazing/soldering including charging with existing gas up to required level and testing complete as to the entire satisfaction complete all as specified.
Material and Labour for replacement of capacitor 10 mfd oil filled for water cooler complete all as specified.
Supply and fixing OLP rellay suitable for water cooler,Refrigerator and deep freezer of any capacity complete all as specified.
M & L for replacement of fan blade ( set of three) of water cooler/blower as per existing sample at the ground complete all as specified.
M & L for replacement of condenser fan motor of water cooler 40/80 ltr/hr capacity as per existing sample or approved make and testing complete all as to the entire satisfaction complete all as specified.
M & L for replacement of condenser fan motor of water cooler 60/120 ltr/hr capacity as per existing sample or approved make and testing complete all as to the entire satisfaction complete all as specified.
S & F in repairs of Thermostat suitable for water cooler 40/60 Ltr/hr capacity of approved make complete all as specified.
Supply and fix Ball brass valves size 15mm, high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule complete all as specified.
M&L for replacement of defective sealed compressor unit upto 320 Ltr cap refrigerator. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make it functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete all as specified.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of refrigerator upto 320 Ltr cap, stop leakage by brizing/soldering including charging the environment friendly refrigerant up to the required level and testing the refrigerator for the entire satisfaction complete all as specified.
M&L for replacement of defective sealed compressor unit upto 320 ltr cap deep freezer. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make in functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete all as specified.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of deep freezer 320 Ltr cap, stop leakage by brazing/soldering including charging with existing refrigerant to required level and testing the refrigerator for the entire satisfaction complete all as specified.
S & F replacement of defective swing motor with new motor suitable for 1.5/2 ton window/split type AC complete all as specified.
Supply and fix in repair front grill for window type AC 1.5 /2.0 TR as per exisiting make complete all as specified.
Replacement of unserviceable remote with new suitable for machine of 1.5/2.0 TR split type AC complete all as specified.
M & L for replacement of voltage stablizer upto 4 KVA ( working voltage 170 -270 V , 15 A Rating) including assembling , testing complete all as specified.
S&F replacement of outer cover of indoor cabinet of split AC 1.5Ton with stand including fashner,nut,bolts etc complete all accessories as per exisiting make complete all as specified.
S&F in repair 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded complete all as specified.
Material and labour for painting to old steel surfaces of Desert cooler of air flow capacity up to 5000 Cum/hr with two coats of synthetic enamel spray paint hammer tone paint of approved colour over one coat of red oxide on external surface and two coats of anti corrosive black paint inside the Body tank and side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler complete all as specified.
M&L for replacement of copper conductor cable 40/0.75 Sqmm 3 core 5 m long with plug top 5 Amp complete all as specified.
M&L for Replacement of PVC water distributor with PVC pipe and PVC pipe elbow complete for desert cooler upto 5000 CFM complete all as specified.
M&L for replacement of Fan blade (set of three) of desert cooler heavy duty HDPE/Metal suitable for 4000/5000 CFM cap complete all as specified.
M&L for replacement of Water lifting submersible pump of head 1.2 m approx suitable for desert cooler as per existing capacity complete all as specified.
M&L for replacement of Water lifting submersible pump of head upto 2.5 m approx suitable for desert cooler/ Duct cooler as per existing capacity complete all as specified.
M&L for Taking down u/s desert cooler motor, cutting of burnt out winding and rewinding super enamelled copper conductor fixing of desert cooler motor to existing location complete all as specified. Note:- Contractor will produce Guarantee letter for the rewinding of the motor minimum 1 year from the date of installarion and testing.
M&L for Taking down desert cooler fan motor and supply and fixing new desert cooler fan motor copper wounded with outer ring, motor supporting legs and nut-bolts for desert cooler upto 5000 CFM copper wounded, three speed approved make complete all as specified.
Supply & Fix in repairs wood wool Pad (set of three), minimum weight 0.80 kg, inside panels of desert coolers with wire mesh complete all as specified.
Collect Ceiling fans/Exhaust fans from E&M yard, removing to workshop for servicing, cleaning, lubricating, spray painting one coat with synthetic enamel paint, writing MES No. replacement of split pin, fan cut block,rubber bush and other spare required if any including fixing PVC cable with stranded copper conductor of size 0.75 Sqmm complete for the following sizes. (Note:- Spares like bearing, terminal connector, gun metal bush shall be measured and paid seperately as supply only) under Ser item No 58.00 to 61.00 herein below. (a) Ceiling fans of 1200/1400 mm size/Exhaust fans of 350 to 450 mm size
Supply only Bearings of suitable size
Supply of Terminal connector 3 way Bakelite
Supply of Capacitor 2.5mfd 230 volts complete all as specified.
Supply of Capacitor 4mfd 230 volts complete all as specified.
Supply and Fix in replacement canopy for ceiling fans (Set of two) complete all as specified.
Supply and Fix in replacement MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm sweep ceiling fan complete all as specified.
M& L transporting the ceiling fans/ exhaust fans to local workshop, rewinding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, capacitors, varnishing,capacitor clip, heating up and testing complete including Refixing the fans at the same locations complete all as specified. (a) Ceiling fan 1200/1400mm sweep working on 230 volts AC supply
All item as per Ser No 64.00 above but exhaust fan upto 350mm sweep working on 230 volts AC supply
All item as per Ser No 64.00 above but exhaust fan 380/450mm sweep working on 230 volts AC supply
S&F in replacement down rod made out of GI pipe medium grade 15mm dia 1.5/2 ft long with fan clamps incl drilling cutting threading etc all as directed for ceiling fan 1200/1400 sweep of following sizes:-
All item as per Ser No 67.00 above but 3 ft long
Supply and fix plug top 15 amps, 230 V complete all as specified.
M&L for Replacement of damaged/defective MS fan blades (MS sheet) assembling for 300/380/450 mm sweep exhaust fan complete all as specified.
S&F, Push type Bib Tap for water cooler made of brass cromium plated for water cooler upto 120 Ltr capacity. Make : Voltas/Blue Star complete all as specified.
S&F water tray suitable upto 120 Ltr capacity water cooler made of SS complete all as specified.
Supply & fix in replacement thermostat ISI marked required at site suitable for the Geysers 25 ltrs. to 50 ltrs capacity complete all as specified.
Supply & fix in replacement safety valve ISI marked suitable for 25 and 50 ltrs. capacity Geysers complete all as specified.
Supply & fix in replacement heating element for 1.5/2KW rating as required at site (any type) including rubber washers (ISI marked) complete all as specified.
Supply & fix in replacement storage inner tank made out of steel sheet 2mm thick suitable for 25 ltr capacity geysers complete all as specified.
All item as per Ser No 76.00 above but 50 ltrs.
Supply & fix in replacement apparatus end plate including rubber washrs for Geyser of 25 to 50 ltrs. Capacity complete all as specified.
Material and labour for PVC connection 15mm dia of 600 length with brass nuts for hot/cold side complete all as specified.
Supply & fix in replacement non-return valve 15mm / 20mm dia of brass ISI marked complete all as specified.
Supply & fix in replacement indicators of Geysers 25 to 50 ltrs. Capacity (Red/ Green/ Yellow) complete all as specified.
Supply & fix in replacement gasket rubber ring for Heater plate of any size Geysers complete all as specified.
Supply only down rod suitable for existing 1200 mm sweep ceiling fan including fan hook ('U' clamp nuts ,split bolts) made out of MS flat iron and made to shape, nut bolt,hanger clamp rubber, shackle top & canopy set etc complete all as specified.
Supply only fan blade iron made suitable for existing 1200 mm sweep ceiling fan including necessary accessories etc complete all as specified.
Supply only BLDC fan motor, single phase,230 V, suitable for existing 1200 mm sweep ceiling fan including capacitor,ball bearing,motor stator,housing etc complete all as specified.
VARDHMAN SALES CORPORATION (BID ID -3428303)
BHAKAR RAM AND SONS (BID ID -3429838)
Shri Electrical Enterprises (BID ID -3429809)
PANKAJ ENTERPRISES (BID ID -3429553)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .