Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 34 SANJAY BUILDING NO 6 ANDHERI KURLA ROAD ANDHERI EAST MUMBAI MAHARASHTRA 400059 | MUMBAI SUBURBAN | MAHARASHTRA | 400059 | Admitted-Finance |
| 2 | Admitted-Finance T10 3RD FLOOR RAYHILSORT RESIDENCY DR PICKLE ROAD UTTARA KANNADA KARNATAKA 581301 UDYAM GA 02 0002041 27AAJCM4307Q1ZY B 29AAJCM4307Q1ZU R | UTTARA KANNADA | KARNATAKA | 581301 | Admitted-Finance |
| 3 | Admitted-Finance 31 NEELGIRI IND ESTATE T J ROAD SEWRI W MUMBAI MAHARASHTRA 400015 | MUMBAI | MAHARASHTRA | 400015 | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Technically Disqualified |
| 5 | Rejected-Technical | Rejected-Technical Technically Disqualified |
Tender Value
Refer Docs
Closing Date
3 Feb 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Admiral Superintendent
Naval Ship Repair Yard Naval Base Karwar 581308
UNDERTAKING DEEFCT RECTIFICATION ON STABILIZER ONBOARD NAVAL VESSEL
2022_NAVY_503128_1
REG/1051/STBL
Open Tender
Marine Services
Lump-sum
180 days
Naval Ship Repair Yard, Naval Base, Karwar
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
9 Mar 2022
22 Jan 2022
4 Feb 2022
22 Jan 2022
3 Feb 2022
22 Jan 2022
120 days
Amount
Services
Charging of hydraulic accumulator with nitrogen up to specified pressure (12.5 bar). In case the bladder of hydraulic accumulator is found defective the firm is required to renew the defective bladder (Mat:- Silicon Rubber)
Clean dirt/ oil from SV mounts on power pack assembly and recoating with Nicole lacquer. The material required is to be provisioned by the firm (Qty of Nicole Lacquer – 20 ltrs)
Undertake chemical cleaning of seawater side of oil coolers.
Renew all hydraulic filter elements. The filter elements are required to be provisioned by the firm.
Renew gland packing on fin stock. The gland packing material to be provisioned by the firm.
Carry out functional test of relief valve. Overhaul of the relief valve is required to be undertaken by the firm if the valve is found defective.
Check hand pumps (fin centring and filling) operation in dry dock. Overhaul of the pumps is required to be undertaken by the firm if the performance of the pump found faulty.
Examine actuator bearing for wear. The bearing to be replaced by the firm if found defective. Bearing type – Ball Bearing.
Clean hydraulic oil tank. Clean tank suction strainer and carry out renewal of all filter elements. The filter elements is required to be provisioned by the firm.
Uncontrolled roll indication observed while deploying stabilisers. Defect to be rectified.
Serviceability checks of all control supply cards, power supply cards relays and following PCB fitted at various control panels:- (a) Control Board card (b) Inverter timer PSU card (c) Interface PCB (d) Gyro Control card (e) Auto speed card All defective PCBs to be repaired by the firm/ replaced and full operationalization of various control components mentioned above to be ensured.
Serviceability checks of MCR control panel. Following to be undertaken:- (a) Insulation checks (b) Renewal of defective wiring (c) Checks of connectors. (d) Serviceability checks of elements inside control panels (e) Checks of fuses and relays (f) Continuity checks All defective components to be repaired by the firm/ replaced and full operationalization of MCR control Panel to be ensured.
Serviceability checks of Gyro control panel. Following to be undertaken:- (a) Insulation checks (b) Renewal of defective wiring (c) Checks of connectors. (d) Serviceability checks of elements inside control panels (e) Checks of fuses and relays (f) Continuity checks (g) Gyro unit All defective components to be repaired by the firm/ replaced and full operationalization of MCR control Panel to be ensured.
Proving of local, remote and auto operation of stabilisers at harbour and at Sea.
Serviceability check of servo control valves. Defective Servo control valves to be repaired/replaced. Additionally, firm to ensure replacement of all defective connectors.
Rectification of creep on stabilisers.
Serviceability checks of all potentiometers. Defective Potentiometers to be repaired/replaced.
Port and Stbd hydraulic rams to be fully overhauled. Material for Ram seal kit replacement to be provided by the firm and pressure testing of the hydraulic rams to be undertaken as per the manual.
Flushing through of the entire system using flushing kit to be undertaken.
Local control panel to be fully overhauled. Following to be undertaken:- (a) Insulation checks (b) Renewal of defective wiring (c) Checks of connectors. (d) Serviceability checks of elements inside control panels (e) Checks of fuses and relays (f) Continuity checks All defective components to be repaired by the firm/ replaced and full operationalization of MCR control Panel to be ensured.
3 way motorized lubricator assembly.
Fin assembly block nut bolt inspect/ fill tallow / grease replace.
Anodes to be checked and replaced. The material for anodes/bolt nuts required for the job to be provided by the firm.
Servicing of Fin locking mechanism for port and stbd fin to be serviced.
H and H Precision Private Limited
Mercury Ship Repairs Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .