Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹16.7 Cr
EMD Value
₹19.7 L
Closing Date
9 Jun 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NBCC Bhawan
NBCC Bhawan
Construction of Sabarimala Edathavalam Projects such as Midway Shelters, Vehicle Parking Sheds at various locations and Master plan development works of base camp for annual pilgrimage at Nilakkal, Kerala Construction of Edathavalams at Maniyankode and Sukhapuram (PACKAGE-II)
NBCC/SBGSouth/Sabarimala/PACKAGEII/2022/10~EW54fcc869b648dfcba744779d
NBCC/SBGSouth/Sabarimala/PACKAGEII/2022/10
Open Tender-Domestic
Civil Works General
NBCC Bhawan
₹11,800
₹19.7 L
9 Jun 2022
25 May 2022
9 Jun 2022
25 May 2022
9 Jun 2022
BILL OF QUANTITY
LOCATION NO. 1 - MIDWAY SHELTER AT SUKHAPURAM
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
1 2.6.1 disposal of excavated earth, lead up to 50 m and lift up to 1.5 Cum 1056.36 165.07 174373.02
m, disposed earth to be levelled and neatly dressed.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundation etc. in layers not exceeding 20 cm
2 2.25 in depth, consolidating each deposited layer by ramming and Cum 642.67 164.81 105918.44
watering, lead up to 50 m and lift up to 1.5 m.
Extra for every additional lift 1.5 m or part there of in
3 2.26.1 excavation / banking excavated or stacked materials. Cum 293.18 67.82 19883.20
All kinds of soil
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
4 4.1.8 work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 Cum 69.093 5869.06 405510.96
graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
5 5.33.1 recommended proportions as per IS: 9103 to accelerate, retard Cum 389.47 8448.78 3290571.69
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
Note: - Cement content considered in this item is @
330kg/cum. Excess/less cement used as per design mix is
payable or recoverable separately. All work upto Plinth level
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
6 5.33.2 recommended proportions as per IS: 9103 to accelerate, retard Cum 576.73 9501.92 5480023.32
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
Note: - Cement content considered in this item is @
330kg/cum. Excess/less cement used as per design mix is
payable or recoverable separately All works above plinth
level upto floor V level
Digitally signed by
DEEPAK DEEPAK KUMAR MEHRA
KUMAR MEHRA Date: 2022.05.25 19:59:54
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Solid block masonry using pre cast solid blocks (Factory
made) of size 30x20x20cm or nearest available size
7 50.6.1.4 confirming to IS 2185 part I of 1979 for foundation and plinth Cum 157.74 5116.15 807041.97
with thickness 20cm and above in: CM 1:6 ( 1 cement : 6
coarse sand ) etc complete
Solid block masonry using precast solid blocks (Factory
made) od size 30X20X20 cm or nearest available size
confirming to IS 2185 Part I of 1979 for super structure up to
floor two level thickness 20 cm and above in CM 1:6 (1
cement : 6 coarse sand) etc complete
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
9 5.22.6 upto plinth level.Thermo-Mechanically Treated bars of grade Kg 118196.80 74.18 8767838.70
Fe-500D or more.
Centering and Shuttering
Centering and shuttering including strutting, propping etc. and
removal of form for :
5.9.1 Foundations, footings, bases of columns, etc. for mass Sqm 119.01 254.19 30250.14
Walls (any thickness) including attached pilasters, butteresses,
11 5.9.2 plinth and string courses etc. Sqm 85.10 496.19 42225.77
Suspended floors, roofs, landings, balconies and access
11 5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 2429.14 449.40 1091656.41
12 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 838.13 613.16 513910.24
13 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 150.00 549.60 82440.00
Solid block masonry using precast solid blocks (Factory
made) od size 40X20X10 cm or nearest available size
14 50.6.3.2 confirming to IS 2185 Part I of 1979 for super structure up to Cum 24.79 6404.83 158775.74
floor two level thickness 10 cm and above in CM 1:6 (1
cement : 6 coarse sand) including cost of scaffolding complete
16 13.1.1 12mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) Sqm 6875.04 226.67 1558365.32
18 mm thick plain cement mortar band in cement mortar 1:4
(1 cement : 4 fine sand):
Providing and laying water proofing treatment in sunken
portion of WCs, bathroom etc., by applying cement slurry
mixed with water proofing cement compound consisting of
applying : a) First layer of slurry of cement @ 0.488 kg/sqm
mixed with water proofing cement compound @ 0.253 kg/
sqm. This layer will be allowed to air cure for 4 hours. b)
Second layer of slurry of cement @ 0.242 kg/sqm mixed with
water proofing cement compound @ 0.126 kg/sqm. This layer
will be allowed to air cure for 4 hours followed with water
curing for 48 hours. The rate includes preparation of surface,
treatment and sealing of all joints, corners, junctions of pipes
and masonry with polymer mixed slurry.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and laying Ceramic glazed floor tiles of size
300x300 mm (thickness to be specified by the manufacturer),
of 1st quality conforming to IS : 15622, of approved make, in
all colours, shades, except White, Ivory, Grey, Fume Red
Brown, laid on 20 mm thick bed of cement mortar 1:4 (1
Cement : 4 Coarse sand), jointing with grey cement slurry @
3.3 kg/ sq.m including pointing the joints with white cement
and matching pigments etc., complete.
Providing and fixing 1st quality Ceramic glazed wall tiles
conforming to IS : 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades,
except burgundy, bottle green, black of any size as approved
by Engineer In-charge, in skirting, risers of steps and
21 11.36 dados,over 12 mm thick bed of cement mortar 1:3 (1 Cement : Sqm 528.73 976.13 516111.17
3 Coarse sand), jointing with grey cement slurry @ 3.3 kg/
sq.m including pointing the joints with white cement mixed
with pigment of matching shade etc., complete.
Providing and laying vitrified floor tiles in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS : 15622, of
approved make, in all colours and shades, laid on 20 mm thick
cement mortar 1:4(1cement : 4 coarse sand), including
grouting the joints with white cement and matching pigments
etc., complete. Size of Tile 600 x 600 mm.
Providing and laying flamed finish Granite stone flooring in
required design and patterns, in linear as well as curvilinear
portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm
(average) thick base of cement mortar 1:4 (1 cement : 4 coarse
sand) laid and jointed with cement slurry and pointing with
23 8.12 white cement slurry admixed with pigment of matching shade Sqm 412.75 3784.88 1562216.79
including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge : Flamed
finish granite stone slab Jet Black, Cherry Red, Elite Brown,
Cat Eye or equivalent.
Applying one coat of water thinnable cement primer of
24 13.43.1 approved brand and manufacture on wall surface : Water Sqm 2002.50 48.43 96981.08
thinnable cement primer
PAINTING Wall painting with premium acrylic emulsion
paint of interior grade, having VOC (Volatile Organic
25 13.83.2 Compound ) content less than 50 grams/ litre of approved Sq.m 1502.50 93.05 139807.63
brand and manufacture, including applying additional coats
wherever required to achieve even shade and colour. Two
Finishing walls with textured exterior paint of required shade
:New work (Two or more coats applied @ 3.28 ltr/10 sqm)
over and including priming coat of exterior primer applied @
Finishing walls with Acrylic Smooth exterior paint of required
shade : New work (Two or more coat applied @ 1.67 ltr/10
sqm over and including priming coat of exterior primer
applied @ 2.20 kg/10 sqm)
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and fixing panelling or panelling and glazing in
panelled or panelled and glazed shutters for doors, windows
and clerestory windows (Area of opening for panel inserts
28 9.7.1 excluding portion inside grooves or rebates to be measured), Sqm 66.00 2669.76 176204.16
Panelling for panelled or panelled and glazed shutters 25mm
to 40mm thick: Second class teak wood.
Providing wood work in frames of doors, windows, clerestory
windows and other frames, wrought framed and fixed in
position with hold fast lugs or with dash fasteners of required
dia & length (hold fast lugs or dash fastener shall be paid for
separately). Second class teak wood
Providing and fixing panelled or panelled and glazed shutters
for shutters for doors, windows and clerestory windows,
including ISI marked M.S. pressed butt hinges bright finished
of required size with necessery screws, excluding panelling
30 9.5.1.1 which will be paid for separately, all complete as per direction Sqm 66.00 3339.61 220414.26
of Engineer - in-charge.
Second class teak wood
35 mm thick shutters
Providing and fixing ISI marked flush door shutters
conforming to IS : 2202 (Part I) decorative type, core of block
board construction with frame of 1st class hard wood and well
31 9.20.1 matched teak 3 ply veneering with vertical grains or cross Sqm 128.40 3262.02 418849.89
bands and faceveneers on both faces of shutters. 35 mm thick
including ISI marked Stainless Steel butt hinges with
necessary screws.
Extra for providing lipping with 2nd class teak wood battens
32 9.23 25 mm minimum depth on all edges of flush door shutters Sqm 138.24 479.48 66283.32
(over all area of door shutter to be measured).
Providing and fixing M.S. grills of required pattern in frames
33 9.48 of windows etc. with M.S. flats, square or round bars etc.
including priming coat with approved steel primer all
9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. Kg 1885.15 147.38 277833.70
Providing 40x5 mm flat iron hold fast 40 cm long including
fixing to frame with 10 mm diameter bolts, nuts and wooden
plugs and embedding in cement concrete block 30x10x15cm
1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate
20mm nominal size)
Providing and fixing aluminium sliding door bolts, ISI marked
anodised (anodic coating not less than grade AC 10 as per IS :
9.96 1868), transparent or dyed to required colour or shade, with
nuts and screws etc. complete :
Providing and fixing aluminium extruded section body tubular
type universal hydraulic door closer (having brand logo with
ISI, IS : 3564, embossed on the body, door weight upto 36 kg
37 9.84 to 80 kg and door width from 701 mm to 1000 mm), with each 67.00 509.04 34105.68
double speed adjustment with necessary accessories and
screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS :
9.97 1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and fixing aluminium handles, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper,
ISI marked, anodised (anodic coating not less than grade AC
9.101 10 as per IS : 1868) transparent or dyed to required colour and
shade, with necessary screws etc. complete.
42 9.101.2 Twin rubber stopper each 134.00 49.80 6673.20
Providing and fixing aluminium work for doors, windows,
ventilator shutters and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other
sections of approved make confirming to IS: 733 and IS:1285
fixing with dash fastner of required dia and size, including
necessary filling up the gaps at junctions, i.e. at top, bottom
and side s with required EPDM rubber / neoprene gasket etc.
Aluminium section shall be smooth, rust free, straight, mitred
43 21.1.1.1 and jointed mechanically wherever required including cleat Kg 252.18 465.59 117412.95
angle, Aluminium snap beading for glazing / panelling, C.P.
brass/ stainless steel screws, all completeas per the
architectural drawings and the direction of Engineer-in-
charge.(Glazing, Panelling and fastners to be paid separately):
For fixed portion Anodised aluminium (Anodised transperant
or dyed to required shade according to IS: 1868, Minimum
anodic coating of grade AC 15)
For shutters of doors, windows, ventilator including providing
and fixing hinges /pivot and making provision for fixing of
fittings wherever required including the cost of EPDM eubber
/ neoprene gasket required (Fitting shall be paid for separately
) Anodised aluminium (Anodised transperant or dyed to
required shade according to IS: 1868, Minimum anodic
coating of grade AC 15)
Providing and fixing glazing in Aluminium door, window,
ventilator, shutters and partitions etc. With EPDM rubber /
neoprene gasket etc complete as per the architectural drawings
and the direction of Engineer-in-charge. (Cost of aluminium
snap beading shall be paid in basic item). : With float glass
panes of 4.0mm Thickness
EXTERIOR WALL CLADDING: Providing and fixing
laterite exterior cladding including the cost of all materials
46 NS and labour charges, scaffolding etc. complete as per drawing Sq.m 460.13 2692.36 1238838.30
and instruction of engineer in charge.
Providing and fixing stainless steel ( Grade 304) railing made
of Hollow tubes, channels, plates etc., including welding,
grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel
nuts and bolts complete, i/c fixing the railing with necessary
47 10.28 accessories & stainless steel dash fasteners , stainless steel Kg 1500.00 619.13 928695.00
bolts etc., of required size, on the top of the floor or the side
of waist slab with suitable arrangement as per approval of
Engineer-in-charge, (for payment purpose only weight of
stainless steel members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc.).
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Steel work in built up tubular (round, square or rectangular
hollow tubes etc.)trusses etc., including cutting, hoisting,
fixing in position and applying a priming coat of approved
steel primer, including welding and bolted with special shaped
washers etc. complete. Hot finished welded type tubes.
loading and unloading, transportation, all lead and lift, etc.,
Supply and installation of GI puff sheet of thickness 100
mm for annadhanamandapam main roof including
49 MR fasterning screw cost of materials and labours, transportation, Sqm 1530.09 2834.06 4336361.20
loading unloading, all lead and lift, etc., complete as per
design and instruction of engineer in charge.
Providing & fixing on roof pressed clay tile (Mangalore tile)
of 20 mm nominal thickness and of approved size and as per
approved pattern on steel frame work complete., loading and
50 12.48 unloading, transportation, all lead and lift, etc., complete. Sqm 1786.86 311.92 557358.31
(steel frame work to be paid separately)
Providing & laying on roof pressed clay tile ridge (Mangalore
tile) of 20 mm thickness and of approved pattern on steel
frame work complete (steel frame work to be paid separately
Fixing of Ceiling kerala tiles below for car porch roof and
sunshades including labour, installation, transportation,
52 MR loading unloading, all lead and lift, scaffolding, etc., complete Sqm 200.00 773.56 154712.00
as per drawing and instruction of engineer in charge.
Supply and fixing of eave board of 12mm thickness
including the cost of all material and labour, installation,
53 MR transportation, etc., complete ass per drawing and instruction Rm 250.00 183.52 45880.00
of engineer in charge.
Providing and fixing factory made P.V.C. door frame of size
50x47 mm with a wall thickness of 5 mm, made out of
extruded 5 mm rigid PVC foam sheet, mitred at corners and
joined with 2 Nos. of 150 mm long brackets of 15x15 mm
M.S. square tube, the vertical door frame profiles to be
54 9.119 reinforced with 19x19 mm M.S. square tube of 19 gauge, Rm 136.80 575.03 78664.10
EPDM rubber gasket weather seal to be provided through out
the frame. The door fame to be fixed to the wall using M.S.
screws of 65/100 mm size, complete as per manufacturer's
specification and direction of Engineer-in Charge.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and fixing factory made panel PVC door shutter
consisting of frame made out of M.S. tubes of 19 gauge
thickness and size of 19 mm x 19 mm for styles and 15x15
mm for top & bottom rails. M.S. frame shall have a coat of
steel primers of approved make and manufacture. M.S. frame
covered with 5 mm thick heat moulded PVC 'C' channel of
size 30 mm thickness, 70 mm width out of which 50 mm shall
be flat and 20 mm shall be tapered in 45 degree angle on both
side forming styles and 5 mm thick, 95 mm wide PVC sheet
out of which 75mm shall be flat and 20 mm shall be tapered in
45 degree on the inner side to form top and bottom rail and
115 mm wide PVC sheet out of which 75 mm shall be flat and
20 mm shall be tapered on both sides to form lock rail. Top,
55 9.120 bottom and lock rails shall be provided both side of the panel.
10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be
provided as gap insert for top rail & bottom rail, paneling of 5
mm thick both side PVC sheet to be fitted in the M.S. frame
welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm)
thick x 15 mm wide PVC sheet beading on inner side, and
joined together with solvent cement adhesive. An additional 5
mm thick PVC strip of 20 mm width is to be stuck on the
interior side of the 'C' Channel using PVC solvent adhesive
etc.complete as per direction of Engineer-in-charge,
manufacturer's specification & drawing.
9.120.1 30 mm thick plain PVC door shutters Sqm 37.80 3627.87 137140.74
Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade : Two or more coats on
ROLLING SHUTTER
Supplying and fixing rolling shutters of approved make, made
of required size M.S. laths, interlocked together through their
entire length and jointed together at the end by end locks,
mounted on specially designed pipe shaft with brackets, side
guides and arrangements for inside and outside locking with
57 10.6.1 push and pull operation complete, including the cost of Sqm 9.00 3035.48 27319.32
providing and fixing necessary 27.5 cm long wire springs
manufactured from high tensile steel wire of adequate strength
conforming to IS: 4454 - part 1 and M.S. top cover of required
thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
LOCATION 1 - COMPOUND WALL
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
1 2.6.1 disposal of excavated earth, lead up to 50 m and lift up to 1.5 Cum 430.80 165.07 71112.16
m, disposed earth to be levelled and neatly dressed.
All kinds of soil
Extra for every additional lift 1.5 m or part there of in
2 2.26.1 excavation / banking excavated or stacked materials. Cum 107.70 67.82 7304.21
All kinds of soil
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm
3 2.25 in depth, consolidating each deposited layer by ramming and Cum 239.72 164.81 39508.25
watering, lead up to 50 m and lift upto 1.5m.
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
4 4.1.8 work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 Cum 21.54 5869.06 126425.42
graded stone aggregate 40 mm nominal size)
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
5 5.33.1 recommended proportions as per IS: 9103 to accelerate, retard Cum 178.32 8448.78 1506544.21
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
Note: - Cement content considered in this item is @
330kg/cum. Excess/ less cement used as per design mix is
payable or recoverable separately. All work upto Plinth level
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level.Thermo-Mechanically Treated bars of grade
Fe-500D or more.
7 Centering and Shuttering
Centering and shuttering including strutting, propping etc. and
removal of form for :
Foundations, footings, bases of columns, etc. for mass
Centering and shuttering including strutting, etc. and removal
Lintels, beams, plinth beams, girders bressumers and
Centering and shuttering including strutting, etc. and removal
Columns, Pillars, Piers, Abutments, Posts and Struts
8 13.1.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Sqm 1471.321 226.67 333504.33
Finishing with Deluxe Multi surface paint system for interiors
and exteriors using Primer as per manufacturers
9 13.48.1 specifications. Two or more coats applied on walls @ 1.25 Sqm 1471.321 129.68 190800.91
ltr/10 sqm over and including one coat of Special primer
applied @ 0.75 ltr /10 sqm
18 mm thick plain cement mortar band in cement mortar 1:4
(1 cement : 4 fine sand):
Finishing walls with Acrylic Smooth exterior paint of required
New work (Two or more coat applied @ 1.67 ltr/10 sqm over
and including priming coat of exterior primer applied @ 2.20
Steel work in built up tubular (round, square or rectangular
hollow tubes etc.) trusses etc., including cutting, hoisting,
fixing position and applying a priming coat of approved steel
primer, including welding and bolted with special shaped
washers etc. complete.
Hot finished welded type tubes
Providing & fixing on roof pressed clay tile (Mangalore tile)
of 20 mm nominal thickness and of approved size and as per
approved pattern on steel frame work complete (steel frame
work to be paid separately)
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Structural steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting, hoisting,
17 10.2 fixing in position and applying a priming coat of approved Kg 1000 88.66 88660.00
steel primer all complete.
Solid block masonry using pre cast solid blocks (Factory
made) of size 30x20x20cm or nearest available size
18 50.6.1.4 confirming to IS 2185 part I of 1979 for foundation and plinth Cum 24.12 5116.15 123401.54
with thickness 20cm and above in: CM 1:6 ( 1 cement : 6
coarse sand ) etc complete
Solid block masonry using pre cast solid blocks ( Factory
made) of size 30x20x20cm or nearest available size
19 50.6.1.5 confirming to IS 2185 Part I of 1979 for super structure up to Cum 147.132 5572.50 819893.07
floor two level thickness 20cm and above in: CM 1:6 ( 1
cement : 6 coarse sand) etc complete
Banking excavated earth in layers not exceeding 20 cm in
depth, breaking clods, watering, rolling each layer with ½
tonne roller, or wooden of steel rammers, and rolling every
3rd and top-most layer with power roller of minimum 8 tonnes
and dressing up, in embankments for roads, flood banks,
marginal banks, and guide banks etc., lead upto 50 m and lift
Preparation and consolidation of sub grade with power road
roller of 8 to 12 tonne capacity after excavating earth to an
average of 22.5 cm depth, dressing to camber and
2 16.1 consolidating with road roller including making good the Sqm 3650.00 118.09 431028.50
undulations etc. and re-rolling the sub grade and disposal of
surplus earth with lead upto 50 metres.
Construction of granular sub-base by providing close graded
Material conforming to specifications, mixing in a mechanical
mix plant at OMC, carriage of mixed material by tippers to
work site, for all leads & lifts, spreading in uniform layers of
3 16.78 specified thickness with motor grader on prepared surface and
compacting with vibratory power roller to achieve the desired
density, complete as per specifications and directions of
Engineer in-Charge.
With material conforming to Grade-I (size range 75 mm to
0.075 mm) having CBR Value-30
Providing, laying, spreading and compacting graded stone
aggregate (size range 53 mm to 0.075 mm ) to wet mix
macadam (WMM) specification including premixing the
material with water at OMC in for all leads & lifts, laying in
4 16.79 uniform layers with mechanical paverfinisher in sub- base / cum 730.00 2794.53 2040006.90
base course on well prepared surface and compacting with
vibratory roller of 8 to 10 tonne capacity to achievethe desired
density, complete as per specifications and directions of
Engineer-in-Charge.
Providing and laying 60mm thick factory made cement
concrete interlocking paver block of M -30 grade made by
block making machine with strong vibratory compaction, of
approved size, design & shape, laid in required colour and
pattern over and including 50mm thick compacted bed of
coarse sand, filling the joints with fine sand etc. all complete
as per the direction of Engineer-in-charge.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and laying Bituminous Macadam using crushed
stone aggregate of specified grading premixed with
bituminous binder, transported to site by tippers, laid over a
previously prepared surface with paver finisher equipped with
6 NS electronic sensor to the required grade, level and alignment
and rolling with smooth wheel, vibratory and tandem rollers
as per specifications to achieve the desired compaction and
density, complete as per specifications and directions of
engineer in charge.
50mm to 100 mm average compacted thickness with bitumen
of grade VG - 30 @ 3.5% (Percentage by weight of total mix)
NS prepared in batch type hot mix plant of 100-120 TPH capacity cum 37.50 7481.00 280537.50
(refer item no. 16.55.1 of DSR 2016 CPWD vol 2)
2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum
of stone chippings of 13.2 mm and 11.2 mm size respectively
per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of
7 NS stone chippings of 13.2 mm and 11.2 mm size respectively,
including a tack coat with hot straight run bitumen, including
consolidation with road roller of 6 to 9 tonne capacity etc.
complete (tack coat to be paid for separately).
With paving Asphalt grade VG - 10 heated and then mixed
with solvent at the rate of 70 grams per kg of asphalt. (refer
item no. 16.33.1 DSR 2016 CPWD vol 2)
Providing and applying tack coat using bitumen emulsion
8 conforming to IS:8887, using emulsion pressure distributer
including prepareing the surface & cleaning with mechanical
9 51.16.31.1.2 On Bitumenous Surface @0.25 Kg / sqm. For BM surface Sqm 750 8.15 6112.50
WATER TANK, OHT & UG SUMP
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
1 2.6.1 disposal of excavated earth, lead up to 50 m and lift up to 1.5 Cum 238.29 165.07 39334.53
m, disposed earth to be levelled and neatly dressed.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundation etc. in layers not exceeding 20 cm
2 2.25 in depth, consolidating each deposited layer by ramming and Cum 71.22 164.81 11737.77
watering, lead up to 50 m and lift up to 1.5 m.
Extra for every additional lift 1.5 m or part there of in
excavation / banking excavated or stacked materials.
All kinds of soil
Providing and laying in position cement concrete of specified
4 4.1.8 grade excluding the cost of centering and shuttering - All Cum 7.943 5869.06 46617.94
work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8
graded stone aggregate 40 nominal size)
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix,including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
5 5.33.1 recommended proportions as per IS: 9103 to accelerate,retard Cum 64.204 8448.78 542445.47
setting of concrete, improve workability without impairing
strength and durability as per direction ofEngineer - in-charge.
Note:- Cement content considered in this item is @ 330 kg/
cum. Excess or lesscement used as per design mix is payable
or recoverable separately.All work upto plinth level
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement content used is
6 5.34.1 payable/ recoverable separately. Cum 64.204 91.09 5848.34
Providing M-30 grade concrete instead of M-25 grade
BMC/RMC. (Note:- Cement content considered in M-30 is @
Centering and shuttering including strutting, etc. and removal
7 5.9.2 of form for:Walls (any thickness) includingattached pilasters, Sqm 284.582 496.19 141206.74
butteresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal
8 5.9.3 of form for:Suspended floors, roofs, landings, balconies and Sqm 90.83 553.47 50271.68
access platform
Steel reinforcement for R.C.C work including straightening,
cutting, bending, placing in position andbinding all complete
upto plinth levelThermo - Mechanically Treated bars of grade
Fe-500D or more
10 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) Sqm 198.83 226.67 45068.80
CONSTRUCTION OF 1 LAKH LITRE WATRE TANK
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
disposal of excavated earth, lead up to 50 m and lift up to 1.5
m, disposed earth to be levelled and neatly dressed.
All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in
excavation / banking excavated or stacked materials. All kinds
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm
3 2.25 in depth, consolidating each deposited layer by ramming and Cum 182.93 164.81 30147.87
watering, lead up to 50 m and lift upto 1.5m.
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
4 4.1.8 work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 Cum 4.20 5869.06 24650.05
graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer - in-
charge. Note:- Cement content considered in this item is @
330 kg/ cum. Excess or less cement used as per design mix is
payable or recoverable separately.
All work above plinth level upto floor V level
Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement content used is
payable/ recoverable separately.
Providing M-30 grade concrete instead of M-25 grade
BMC/RMC. (Note:- Cement content considered in M-30 is @
Centering and Shuttering
Centering and shuttering including strutting, propping etc. and
removal of form for :
Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
9 5.22.6 upto plinth level.Thermo-Mechanically Treated bars of grade Kg 8400.00 74.18 623112.00
Fe-500D or more.
10 13.1.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Sqm 259.20 226.67 58752.86
Earth work in Excavation by mechanical means (hydraulic
excavator)/ manual means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm on plan), including
1 2.8.1 dressing of sides and ramming of bottoms, lift upto 1.5m Cum 44.76 218.08 9760.61
including getting out excavated soil and disposal of surplus
excavated soil as directed, within a lead of 50m. All kinds of
Extra for every additional lift of 1.5 m or part thereof in
2 2.26 excavation /banking excavated or stacked materials.
All kinds of soil
2.26.1 All kinds of soil Cum 31.81 67.82 2157.63
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm
3 2.25 in depth, consolidating each deposited layer by ramming and Cum 327.46 164.81 53969.34
watering, lead up to 50 m and lift upto 1.5m.
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
4 4.1.8 work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 Cum 25.82 5869.06 151550.87
graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
5 5.33.1 recommended proportions as per IS: 9103 to accelerate, retard Cum 30.00 8448.78 253463.40
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
Note: - Cement content considered in this item is @
330kg/cum. Excess/ less cement used as per design mix is
payable or recoverable separately. All works Upto Plinth level
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
6 5.33.2 recommended proportions as per IS: 9103 to accelerate, retard Cum 42.86 9501.92 407280.80
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer - in-
charge. Note:- Cement content considered in this item is @
330 kg/ cum. Excess or less cement used as per design mix is
payable or recoverable separately.
All work above plinth level upto floor V level
Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement content used is
payable/ recoverable separately.
7 5.34.1 Providing M-30 grade concrete instead of M-25 grade Cum 42.86 91.09 3904.39
BMC/RMC. (Note:- Cement content considered in M-30 is @
Centering and Shuttering
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Centering and shuttering including strutting, propping etc. and
removal of form for :
Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level.Thermo-Mechanically Treated bars of grade
Fe-500D or more.
12 mm cement plaster of mix:
Solid block masonry using pre cast solid blocks ( factory
made) of size 40x20x20cm or nearest available size
confirming to IS 2185 part 1 of 1979 for foundation and plinth
with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6
coarse sand) etc complete
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45
cm dry brick honey comb shaft with bricks and S.W. drain
pipe 100 mm diameter, 1.8 m long complete as per standard
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
1 5.33.1 recommended proportions as per IS: 9103 to accelerate, retard Cum 8.32 8448.78 70319.20
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
Note: - Cement content considered in this item is @
330kg/cum. Excess/less cement used as per design mix is
payable or recoverable separately. All works Upto Plinth level
Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement
content used is payable/ recoverable separately.Providing M-
2 5.34.1 30 grade concrete instead of M-25 grade Cum 6.86 91.09 625.15
BMC/RMC. (Note:- Cement content considered in M-30 is @
Centering and shuttering including strutting, etc. and removal
3 5.9.2 of form for:Walls (any thickness) including attached pilasters, Sqm 51.98 496.19 25792.95
butteresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal
4 5.9.3 of form for:Suspended floors, roofs,landings, balconies and Sqm 17.42 553.47 9641.45
access platform
Steel reinforcement for R.C.C work including straightening,
cutting, bending, placing in position andbinding all complete
upto plinth level Thermo - Mechanically Treated bars of grade
Fe-500D or more
6 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) Sqm 79.19 226.67 17950.68
ELECTRICAL WORK
SUB HEAD I - CT METERING PANELS
1 CT METERING PANEL -
Supply and erection of compartmentialised CT metering panel
(3 Compartment type) for
receiving the EB supply consisting of :-
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
300A 4 Pole copper bus bars suitable to accommodate 3 Nos.
CT's.The meter chamber will have provision to fix 3 phase 4
wire 50 HZ CT operated Kwhr meter to be supplied by supply
authorities and the front meter door shall be fitted with glass
/Acrylic cover infront of meter dial to read the meter
recording the meter door shall have provision for sealing
arrangement by supply authorities
The TTB chamber will have 3 phase 4 wire 50 HZ TTB.
All chambers should have sealing arrangement provision.
3 Nos 315 Amps Porcelain cutouts and 500 Amps Neutral link
with cable chamber suitable for receiving 2 no. 3 1/2 core
240 sq mm PVC insulated Aluminium conductor armoured
The board should be manufactured such that should be
approved by Local supply authorities.
CT METERING PANEL - Set 1.00 58000.00 58000.00
SUB HEAD I - PANELS
GENERAL REQUIREMENT OF PANELS
The size of bus shall be uniform through out the panel with
necessary connecting fish plates.
Each of the outgoings shall be connected to bus with
interconnection of adequate size of AL. flat. The outgoing
terminals of each of the ACB /MCCB shall be provided with
terminal connection to receive appropriate size of
cable/busduct of outgoing.
The interconnection and the terminal connections shall be
sleeved with colour coded heat shinkable sleeves with the
exception joints.The switch board shall be provided with
Double earth bus with AL. flat asper IS..The switch doors and
instrument chamber of the board shall be earthed with flexible
braided AL/CU. as per requirement of Electrical Inspectorate /
The instruments chamber meter / instruments etc. shall be
wired with 1.5 Sqmm for control &2.5 Sq.mm of 1.1KV for
CTs multistrand copper conductor wire with double sleeving
and with appropriate colour code and the terminal ferruled
and connectedwith suitable Lugs etc.
The Panel board shall be so manufactured for extenion on
both sides bus bars space provision for fixing fish plates etc.
shall be provided in the panel. The future panel coupling holes
provided in the panel shall be plugged with nylon/ PVC
bushes/ suitable size bolts & nuts to make the panel dust &
vermin proof. Whichever panels are called for the extention.
All incomers ACBs/ MCCBs terminal shall be brough on top /
bottom of panel to receive bus duct bus/Cables. Necessary
shrouding and fixing arrangement shall also be provided at top
/ bottom of panel as acceptable to inspectorate and also as per
site requirements.
All ougoing ACBs/MCCBs/SDFs terminal shall be brough on
top / bottom/cable chambers of panel to receive bus duct
bus/Cables. Necessary shrouding and fixing arrangement shall
also be provided at top / bottom of panel as acceptable to
inspectorate and also as per site requirements.
The incoming terminal of each of the MCCB/SDF shall be
connected to respective bus and their outgoing terminal
connection brought out to receive AYFY cables and this
terminal are properly supported so that the stress of the cable
does not transfer to MCCB/SDF terminal necessary shrouds
between phase should also be provided as per OEM.
All incoming/ougoing MCBs power wiring shall be brought
up to respective rated power terminal block. All starters
power & control wiring shall be brought up to terminal
block.All CTs are resincost type only All meters shall have
A port compartment shall be provide in all panels
with 20% spare terminal block. All external linking like
Remote,IBMS, RS485,etc shall be wired upto this.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
The Panel shall be finished with powder coated paint of
approved shade after duly treated for rust prevention. The
panel shall be fabricated as per relevant IS and with adequate
clearances and as per the norms stipulated by Electrical
Inspecting authority.The panel shall be provided with warning
labels, feeder designation and all other provisions as may be
required in IS wheather or not all item has been brought in
this bill of quantities.The feeder arrangement shall be made to
suit site condition and to avoid cross over of cables /busduct.
2000A and Above rated panels shall be of type testded panels
as per IS 61439 part 1&2
2 NS Technical Specification for MAIN PANEL -
Suupply, erection, testing and commissioning of floor
mounting free standing dust &
vermin proof cubicle pattern switch board fabricated out of 14
sheets comprising of following for MAIN PANEL.
1 No.- 250A 4P 35KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
protection and with 230V shunt
trip releases Aux switch of 1 NO + 1 N/C for contacts
multiplication etc. as
1 - Digital type flush mounting power monitor
to indicate the following parameters and 5A CT
Current, Voltage, Frequency, KWh & KW,etc.
3 - Current transformer of ratio 315/5 class 1, 15VA
burden for metering.
1 Set. - 3 Nos. R, Y, B indicating lamp to indicate
supply position.
1 Set. - 2 Nos. Red & Green indicating lamp to
indicate ON-OFF
position of breaker.
3 Nos.- 250/5A Class P5 T5, 10 VA for power factor
1Set - Potential protection HRC fuses/MCB of suitable
indicating lamp, meter, control circuit etc.
GENERATOR INCOMER
1 No.- 250A 4P 35KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
protection and with 230V shunt
trip releases Aux switch of 1 NO + 1 N/C for contacts
multiplication etc. as
1 No. - Digital type flush mounting power monitor
with inbuilt selectors to indicate the following
Current, Voltage, KW,KWhr, Power factor,
Frequency, etc. CL -0.5
3 Nos. - 250/5A Class 1 15 VA C.T. metering
1 Set. - 3 Nos. R, Y, B indicating lamp to indicate
supply position.
1 Set. - 2 Nos. Red & Green indicating lamp to
indicate ON-OFF
position of breaker.
1 Set. - Amber Breaker trip due to fault indication
1 Set. - Potential fuses/MCB for voltmeter,
indicating lamps, meter, control circuit etc.
1 Set. - Outgoing terminals to receive Cables.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Both the incomers shall be mechanically interlocked to avoid
parlleing each other.
1 Set. 250A TP & N bus bars with Alu. flat with the size
having a current density of
0.7A / Sqmm. The Bus bar shall be provided with
colour coded heat shrunkable
PVC sleeves with the exception of joint. The bus bar
shall be supported at
suitable intervals with SMC/ FRP as per IS.
1 Nos. - 160A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
4 Nos. - 100A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
4 Nos. - 100A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
5 Nos. - 63A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
2 Nos. - 40A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
2 Nos. - 32A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
3 NS Technical Specification for APFCR Panel
Supply, erection, testing & commissioning of floor/wall
mounting dust & vermin proof
cubicle pattern noncompartmentalised outdoor APFCR
Panel fabricated out of 14 /16 SWG CRCA
sheet comprising of the following :-
1 No.- 160A TP & N 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
protection and with 433V shunt
trip releases Aux switch of 1 NO + 1 N/C for contacts
multiplication etc. as
1 - 8 stage APFCR Relay.
1 - Auto manual selector switch.
1 - Digital type flush mounting meter with inbuilt
selector to indicate the
following parameters suitable for operation with
5A CT secondary.
Current, Voltage, Frequency
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
1 Set. - 3 Nos. R, Y, B indicating lamp to indicate
supply position.
1 Set. - 2 Nos. Red & Green indicating lamp to indicate
position of breaker.
1 Set. - Amber Breaker trip due to fault indication
1Set - Potential protection HRC fuses/MCB of suitable
indicating lamp, meter, control circuit etc.
1 - 160A TP & N Alu. bus bar having a current
density of 0.7A per Sqmm
and with adequate number of FRP/SMC bus
supports at suitable interval
as per IS. The busbar shall be PVC sleeved with
heat shrukable colour
coded PVC sleeves with the exception of joint.
1 No. - Capacitor compartment each with 63A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 15 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 15 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
2 Nos. - Capacitor compartment each with 63A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 10 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 10 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 5 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 5 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 4 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 4 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 3 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 3 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 2 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 2 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 1 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 1 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
1 - 160A TP & N Alu. bus bar having a current
density of 0.7A per Sqmm
and with adequate number of FRP/SMC bus
supports at suitable interval
as per IS. The busbar shall be PVC sleeved with
heat shrukable colour
coded PVC sleeves with the exception of joint.
The instrument chamber meter /instruments shall be wired
with 2.5 Sqmm for CT's &
1.5 Sqmm for other circuits multi-strand copper conductor
wire with double sleeving &
with appropriate colour code and the terminal ferruled and
connected with suitable lugs.
The above panel shall be fabricated as per IS and complete
with specified bus
bar, bus supports, interconnections from bus to MCCB,
MCCB to capacitor banks
duly taped or sleeved wirings providing 2 Nos.earth bus with
flat, door earthing with braided copper etc. all complte as per
IS as acceptable
to Architects in conformity with the Local Electrical
Inspectorate whether or
not all items has brought in this. The board shall be provided
with noncompartmental
and intercompartment shrouds, terminal extensions for
receiving cable, shrouds
for terminals etc. The aggregated capacity of each of the
bank shall be of 50
KVAr. The board shall be finished with powder coated paint
of approved shade
after duly treated for rust prevention and appllying 2 coats of
metal primer. The
board shall be provided with necessary warning, feeder
designation labels as per
IS and as per site requirement and cater to General
requirement of switch board
specification given in the tender.
SUB HEAD V - WIRING
4 1.10 Wiring for light point / fan point / exhaust fan point / call
bell point with 1.5 sq.mm. FRLS PVC insulated copper
conductor single core cable in surface / recessed medium
class pvc conduit, with modular switch, modular plate,suitable
G.I.Box and earthing the point with 1.5 sq mm. FRLS PVC
insulated copper conductor single core cable etc as required.
5 1.55 Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point (without independent
switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable in surface/ recessed PVC conduit,
and earthing the point with 1.5 sq. mm FRLS PVC insulated
copper conductor single core cable etc. as required.
6 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface /
recessed medium class pvc conduit, two way modular switch,
modular plate ,suitable GI box, and earthing the point with Point 3 1060.28 3180.84
1.5sqmm FRLS PVC insulated copper conductor single core
cable etc as required.
7 1.14 Wiring for circuit / sub main wiring along with earth wire
with the following sizes of PVC insulated copper conductor,
single core cable in surface/recessed medium class PVC
conduit as required. (for Lighting Ckt)
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
8 1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
recessed medium class PVC conduit along with 1 No. 4 sq. RM 525 220.18 115594.50
mm FRLS PVC insulated copper conductor single core cable
for loop earthing as required.
9 1.32 Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess,including providing
and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and Each 16 532.10 8513.60
15/16 amps modular type switch, connections, painting etc as
10 1.31 Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess,including and
providing and fixing 3 pin 5/6 amps modular socket outlet
and 5/6 amps modular type switch, connections, earthing,
painting etc as required. (for light plugs to be used in non
residential buildings)
11 1.25 Supplying and fixing two module stepped type electronic fan
regulator on the existing modular plate switch box
including connections but excluding modular plate etc. as
Supply,installation,testing and commissioning of 305 mm
12 NS exhaust fan, metal body, i/c making the hole to suit the size of Each 7.00 2171.00 15197.00
the above fan, making good the damages connections etc as
Supply, Installation, testing and commissioning of 1200mm
sweep ceiling fan with double bearing, i/c 3 nos blade,
condensor, down rod, fan shackle, bolt and nut, cottor pin etc
13 NS operation on 240 volts,single phase,50HZ,AC supply, of Each 107.00 2537.00 271459.00
360/390RPM,including wiring the down rod of standard
length( upto 75cm) with 1.5sq.mm FR PVC insulated, copper
conductor single core cable etc as reqd.(but without regulator.
Supply, Installation, testing and commissioning of 6W LED
STEP Light fitting with all other accessoriess i/c connections
with 1.5 sq.mm PVC insulated FR copper conductor single
core cable etc as required.
Supply, Installation, testing and commissioning of 11W LED
Mirror Light wall mount fitting with all other accessoriess i/c
connections with 1.5 sq.mm PVC insulated FR copper
conductor single core cable etc as required.
Supply, Installation, testing and commissioning of 18W LED
Wall Light fitting with all other accessoriess i/c connections
with 1.5 sq.mm PVC insulated FR copper conductor single
core cable etc as required.
Supply, Installation, testing and commissioning of 30W LED
Down Light fitting surface mounted with all other
accessoriess i/c connections with 1.5 sq.mm PVC insulated
FR copper conductor single core cable etc as required.
Supply, Installation, testing and commissioning of 18W LED
Tube Light fitting Surface/suspended/recess mounted with all
18 NS other accessoriess i/c connections with 1.5 sq.mm PVC Each 170.00 1771.00 301070.00
insulated FR copper conductor single core cable etc as
Supply, Installation, testing and commissioning of 40W LED
IP65 Tube Light fitting Surface /suspended/recess mounted
19 NS with all other accessoriess i/c connections with 1.5 sq.mm Each 15.00 2960.00 44400.00
PVC insulated FR copper conductor single core cable etc as
Supply, Installation, testing and commissioning of 40W LED
Tube Light fitting Surface /suspended/recess mounted with all
20 NS other accessoriess i/c connections with 1.5 sq.mm PVC Each 54.00 3289.00 177606.00
insulated FR copper conductor single core cable etc as
CABLE TERMINATION & CABLE TRAY
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Supplying and making end termination with brass
compression gland and aluminium lugs for following size of
PVC insulated and PVC sheathed XLPE armoured power
cable of 1.1 KV grade as required.
Supplying and laying of the following size of one number
PVC insulated and PVC sheathed XLPE armoured power
cable confirming to IS:7098/Part-I/85 etc as required.
Supplying and installing following size of perforated Hot
Dipped Galvanised Iron cable trays with perforation not more
than 17.5%, in convenient sections, joined with connectors,
suspended from the ceiling with G.I. suspenders including
mm depth X 1.6 mm thickness RM 41 665.00 27265.00
NS 300 mm width X 50 mm depth X 1.6 mm thickness RM 85 928.00 78880.00
Supplying and installing following size of perforated Hot
Dipped Galvanised Iron cable tray bends with perforation not
more than 17.5%,, joined with connectors, suspended from the
ceiling with G.I. suspenders including bolts & nuts, etc as
150 mm width X 50 mm depth X 1.6 mm thickness Each 5 1289.00 6445.00
NS 300 mm width X 50 mm depth X 1.6 mm thickness Each 12 1911.00 22932.00
Supplying and fixing cable identification tags made out of
round aluminium plates of thickness not less than 3mm and
tying with cable with appropriate intravels for cable
emenating from individual SSB.
DISTRIBUTION BOARD, LIFT & ALLIED WORKS,
Supplying and fixing following rating, Three pole, 415 V,
25 MCB 10KA " C " Curve in the existing MCB DB complete
with connections, testing and commissioning etc. as required
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA,
"C" curve, miniature circuit breaker suitable for inductive
load of following poles in the existing MCB DB complete
with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, Four pole, 415 V,
27 MCB 10KA " C " Curvein the existing MCB DB complete
with connections, testing and commissioning etc. as required
Supplying and fixing following way, horizontal type three
pole and neutral, sheet steel, MCB distribution board, 415 V,
28 2.4 on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder
painted including earthing etc. as required. (But without
NS 4MCB/RCCB/Isolator)
way (4 + 12), Double door Each 1 2902.00 2902.00
NS 8 way (4 + 24), Double door Each 1 4187.00 4187.00
NS 12 way (4 + 36), Double door Each 1 4502.00 4502.00
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Supplying and fixing of following ways surface/ recess
mounting, vertical type, 415 V, TPN MCB distribution board
of sheet steel, dust protected, duly powder painted, inclusive
29 of 100 A tinned copper bus bar, common neutral link, earth
bar, din bar for mounting MCBs (but without MCBs and
incomer ) as required . (Note : Vertical type MCB TPDB is
normally used where 3 phase outlets are required.)
NS 4 way ( 4 + 12), Double door Each 1 5945.00 5945.00
NS 8 way ( 4 + 24), Double door Each 1 7479.00 7479.00
Supplying and fixing following rating, TPN, 415 V, MCCB
30 10KA " C " Curvein the existing MCB DB complete with
connections, testing and commissioning etc. as required
Supplying and fixing following rating, Three pole, 415 V,
31 MCB 10KA " C " Curve in the existing MCB DB complete
with connections, testing and commissioning etc. as required
Wiring with 3 x 2.5 Sqmm PVC copper wire in 20mm MS
electrical grade conduit with all standard accessories for lift
shaft lights & 6/16A 3pin sockets in the lift shaft as surface
conduit wiring for lift well lighting. (Lift shaft lighting and
socket to be controlled by SP MCB in the lift room lighting
Supply and fixing of 2 Nos. 6A 1 Way switch 1 No. 6/16A
32 NS 3pin socket MODULAR type to an 16g MS enclosure with Nos 6 1567.00 9402.00
3mm thick hylam sheet top. (Note: The MS box shall have
arrangement to terminate earth wire.
Supply & fixing Bulk head fittings with metal guard complete
33 NS with holder etc. suitable to house 10W LED at lift shafts Nos 6 1689.00 10134.00
EARTHING & DG SET
5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm Set
thick including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering
pipe of 2.7 metre long etc.with charcoal/coke and salt as
5.15 Providing and fixing 25mm x 5mm G.I. strip on surface or in Metre
40 recess for connections etc. as required. 471 169.07 79631.97
Supply and drawing bare earthing conductors of the following Metre
41 90.16.1.4 sizes along with wiring/ cables and giving connection as 29 87.35 2533.15
42 NS Design, manufacture, transportation, installation testing and
capacity run on 1500 RPM, four stroke, designed for
operating on HSD,
completed with 180 KVA Alternator 415V, 50 hZ, 0.8 PF,
370 litres, batteries 12V suitable for starting of the DG set.anti
pads, silencers with thermal insulation, with Electonic
Engine control panel suitable for Syncronous operation and
system in suitable size accoustic enclosure as per
requirements of PCB &
authorites includes the following transport, insurance,
inclusing performance tests and excluding civil foundations
civil,structural and
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
electrical works, control and instrumentation etc.The rate
shall include the
fuel pipelines including valuves from tank to engines.The
shell have proper air intake and exhaust system as per OEM Nos 1 592000.00 592000.00
Providing and fixing 40mm x 6mm GI strip on surface/recess
from earth electrode as required Metre
Providing and fixing 25mm x 6mm Copper strip on
surface/recess from earth electrode as required Metre
Providing and fixing 8SWG copper wire on surface or in
recess for connections etc. as required. Metre
Supply and laying of necessary control cabling from generator
engine panel to generator control panel with suitable gland,
crimping sockets and earthing etc., in prepared trench / cable
tray for DG sets.
a) NS 16C x 2.5 Sqmm armoured copper cable. Metre 24 469.00 11256.00
b) NS 4C x 4 Sqmm armoured copper cable. Metre 24 215.00 5160.00
c) NS 4C x 2.5 Sqmm armoured copper cable. Metre 24 152.00 3648.00
Supplying and fixing of MS Self Supporting structure made of
MS Channels and MS angles on existing CC foundation for
46 NS supporting the exhaust piping of the DG Set including Kg 500 140.00 70000.00
painting with zinc chromite primer and aluminium/ synthetic
enamel paint etc as required.
47 MISCELLANEOUS
Providing and fixing the following electrical accessories
confirming to relevant IS specification
b NS LT Mat of size (6mm thick of size 2M X 1 M) Nos. 4 8897.00 35588.00
c NS Fire Extinguishers, Dry Chemical type 5Kg Nos. 2 5367.00 10734.00
d NS 3 nos Fire Buckets with stand and sand filled Set 1 2648.00 2648.00
e NS First Aid box Nos. 1 2006.00 2006.00
f NS First aid chart(in Malayalam,Hindi & English) Nos. 1 1416.00 1416.00
h NS Portable rechargeable emergency led light Nos. 1 5389.00 5389.00
i NS Earth discharge rod No. 1 9440.00 9440.00
A. SANITARY FIXTURES & FITTINGS:
1 Providing and fixing white vitreous china pedestal type water
closet (European type) with seat and lid, 10 litre low level
white vitreous china flushing cistern & C.P. flush bend with
fittings & C.I. brackets, 40 mm flush bend, overflow
17.3 arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete,
including painting of fittings and brackets, cutting and making
good the walls and floors wherever required :
17.3.1 W.C. pan with ISI marked white solid plastic seat and lid Nos. 15 6020.57 90308.55
2 Providing and fixing white vitreous china flat back half stall
urinal of size 580x380x350 mm with white PVC automatic
flushing cistern, with fittings, standard size C.P. brass flush
pipe, spreaders with unions and clamps (all in C.P. brass) with
waste fitting as per IS : 2556, C.I. trap with outlet grating and
other couplings in C.P. brass, including painting of fittings
and cutting and making good the walls and floors wherever
Single half stall urinal with 5 litre P.V.C. automatic flushing
3 NS Providing & Fixing white glazed vitreous china urinal
partitions of approved make including rawl plugs, screws or
any other approved device for fixing arrangements, making Nos. 20 2086.44 41728.80
holes in walls, floors & making good.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
4 Providing and fixing wash basin with C.I. brackets, 15 mm
C.P. brass pillar taps, 32 mm C.P. brass waste of standard
17.7 pattern, including painting of fittings and brackets, cutting and
making good the walls wherever require:
White Vitreous China Flat back wash basin size 550x400 mm
17.7.4 with single 15 mm C.P. brass pillar tap Nos. 17 2381.82 40490.94
5 Providing and fixing CP Brass 32mm size Bottle Trap of
17.22.A approved quality & make and as per the direction of Engineer- Nos. 17 1042.12 17716.04
6 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible
17.16.A tube upto 1 metre long with S.S. triangular plate to Eureopean Nos. 17 333.94 5676.98
type W.C. of quality and make as approved by Engineer - in -
7 Providing and fixing CP Brass Single lever telephonic wall
17.22.B mixer of quality & make as approved by Engineer in charge.
(a) 15 mm nominal dia Nos. 8 6180.46 49443.68
8 18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm
9 17.73 Providing and fixing PTMT towel rail complete with brackets
fixed to wooden cleats with CP brass screws with concealed
fittings arrangement of approved quality and colour.
17.73.2 600 mm long towel rail with total length of 645 mm, width 78
mm and effective height of 88 mm, weighing not less than 190 Nos. 17 553.99 9417.83
10 17.34 Providing and fixing toilet paper holder :
11 NS Providing and fixing CP brass twin coat hook. Nos. 15 935.12 14026.80
Providing and fixing PTMT liquid soap container 109 mm
wide, 125 mm high and 112 mm distance from wall of
12 17.71 standard shape with bracket of the same materials with snap Nos. 4 180.67 722.68
fittings of approved quality and colour, weighing not less than
Providing and fixing C.P. brass long nose bib cock of
approved quality conforming to IS standards and weighing not
less than 810 gms.
15 mm nominal bore Nos. 32 727.78 23288.96
Providing and fixing C.P. brass stop cock (concealed) of
14 18.52 standard design and of approved make conforming to IS:8931.
18.52.1 15 mm nominal bore Nos. 2 715.52 1431.04
Providing and fixing C.P. brass angle valve for basin mixer
15 18.53 and geyser points of approved quality conforming to IS:8931
Providing and fixing 600x450 mm beveled edge mirror of
superior glass (of approved quality) complete with 6 mm thick
16 17.31 hard board ground fixed to wooden cleats with C.P. brass Nos. 17 1072.01 18224.17
screws and washers complete.
Providing and fixing complete set of sanitary fixtures for
handicapped toilets, make of Cera "Crane" / Hindware Cat.
no. 70002) / or approved equivalent comprising of EWC - P,
Cistern, Seat Cover, Twin Flush Fittings, Wash Basin
17 NS 450x300, Half pedestal, 1 faucet with spatula lever, 1 hinged Nos. 3 36612.80 109838.40
rail and 2 grab bars, including cutting and making good the
walls and floors wherever required complete as per directions
of Engineer in charge.
Providing and fixing uplasticised PVC connection pipe with
18.21.1 30 cm length
18.21.1.1 15 mm nominal bore Each 32 77.85 2491.20
B. COLD / HOT / FLUSHING WATER SUPPLY
(INTERNAL / EXTERNAL):
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
1 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, including
fixing the pipe with clamps at 1.00 m spacing. This includes
jointing of pipes & fittings with one step CPVC solvent
cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall
18.7.3 25 mm nominal outer dia Pipes RM 230.00 283.35 65170.50
2 18.7.4 32 mm nominal outer dia Pipes RM 150.00 378.83 56824.50
3 18.7.5 40 mm nominal outer dia Pipes RM 70.00 505.24 35366.80
4 18.7.6 50 mm nominal outer dia Pipes RM 100.00 718.93 71893.00
5 NS 63 mm nominal outer dia Pipes RM 200 980.97 196194.00
6 NS 62.50 mm nominal inner dia Pipes RM 50 980.97 49048.50
7 NS 75 mm nominal inner dia Pipes RM 10 1209.64 12096.40
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, i/c fixing
the pipe with clamps at 1.00 m spacing. This includes jointing
of pipes & fittings with one step CPVC solvent cement and
the cost of cutting chases and making good the same including
testing of joints complete as per direction of Engineer in
Concealed work, including cutting chases and making good
11 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply
including all CPVC plain & brass threaded fittings This
includes jointing of pipes & fittings with one step CPVC
solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge.
18.9.3 25 mm nominal outer dia Pipes RM 20.00 251.18 5023.60
12 18.9.4 32 mm nominal outer dia Pipes RM 10.00 328.37 3283.70
13 18.9.5 40 mm nominal outer dia Pipes RM 10.00 420.90 4209.00
14 18.9.6 50 mm nominal outer dia Pipes RM 10.00 634.66 6346.60
15 18.9.7 62.50 mm nominal inner dia Pipes RM 250 1417.74 354435.00
16 18.9.8 75 mm nominal inner dia Pipes RM 10 1574.10 15741.00
17 18.9.9 100 mm nominal inner dia Pipes RM 10 2120.68 21206.80
18 NS Supplying, laying/ fixing, testing and commissioning of
following of duly insulated with following closed cell
elastometric nitrile rubber of minimum 45 Kg / cu m
density, thermal conductivity 0.037 W/MK or better at 20 deg
mean temperature class ‘O’ insulation applied by suitable
rubber based adhesive complete and as per specifications and
20 required complete
mm dia (19 in all
mm thick respect.
nitrile rubber insulation) RM 10 82.52 825.20
19 NS 25 mm dia (19 mm thick nitrile rubber insulation) RM 50 88.90 4445.00
20 NS 32 mm dia (19 mm thick nitrile rubber insulation) RM 50 98.46 4923.00
21 NS 40 mm dia (19 mm thick nitrile rubber insulation) RM 10 108.02 1080.20
22 NS 50 mm dia (19 mm thick nitrile rubber insulation) RM 5 123.96 619.80
23 NS 65 mm dia (19 mm thick nitrile rubber insulation) RM 5 127.15 635.75
24 Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) :
31 NS Providing and fixing Butterfly valve (upto 150mm dia with
band lever operation & above with gear box operation) with
SS-304 disc. Tested to a pressure not less than 15 Kg/sq.cm
including rubber gaskets, flanges, nuts, bolts, washers &
painting complete as required.
32 NS Providing & fixing Auto Air vent for cold / hot water supply
risers, suitable for pressure not less than 15 Kg/Sq.cm.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
33 18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick
work in cement mortar 1:4 (1 cement : 4 coarse sand) for
sluice valve, with C.I. surface box 100mm top diameter, 160
mm bottom diameter and 180 mm deep ( inside) with chained
lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size ) , i/c necessary
excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
12 mm thick, finished with a floating coat of neat cement
complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class
designation 7.5
C. INTERNAL DRAINAGE (SOIL, WASTE & VENT)
1 NS Providing, jointing, testing and fixing UPVC Soil, Waste &
Vent system conforming to IS : 13592 Type B and UPVC
fittings (moulded as well as fabricated) like bends, tees, Y-
tees, crosses, boss connections, access pieces, saddle pieces,
cleanouts, adaptors for connections to other materials, plugs,
reducers, cowls, offset and other specials, jointing done with
solvent cement for fittings and specials, fixing inside sunken
slab / suspended below RCC slab for concealed soil and waste
lines, making proper connection and also pipes may be laid /
fixed in sunken floors, under hung from ceiling. The pipes
laid in sunken floor shall be supported with cement concrete
(1:2:4) blocks and under hung lines shall be supported from
slab with universal clamps. The installation shall be complete
in all respects including cutting chases / holes in walls, slabs
and making good the same as per specifications. (All GI pipe
supports to hold the pipes is included in this item).
3 Providing, jointing, testing and fixing UPVC Soil, Waste &
Vent system conforming to IS : 13592 Type B and UPVC
fittings (moulded as well as fabricated) like bends, tees, Y-
tees, crosses, boss connections, access pieces, saddle pieces,
cleanouts, adaptors for connections to other materials, plugs,
reducers, cowls, offset and other specials, jointing done with
solvent cement for fittings and specials, fixing at wall / ceiling
level supported by galvanized steel slotted rails, threaded
rods, clamps, hangers etc., making proper connection etc for
duct and ceiling suspended soil and waste lines. The
installation shall be complete in all respects including cutting
chases / holes in walls, slabs and making good the same as per
specifications. (All major MS / GI supports to hold the stack
is included in this item).
6 Providing, fixing, jointing, testing and commissioning UPVC
(Class III) Rain water downtake pipe conforming to IS:4985
cut to required lengths including all necessary fittings and
specials.UPVC fittings (moulded as well as fabricated) like
bends, tees, Y-tees, crosses, boss connections, access pieces,
saddle pieces, cleanouts, adaptors for connections to other
materials, plugs, reducers, cowls, offsets and other specials.
Fixing at wall/ceiling level supported by galvanized steel
slotted rails, threaded rods, clamps, hangers etc. Making
proper connection with cement solvent joint as per BIS /
manufacturer. Cutting, chases / holes in floors / walls / slab
and making good wherever required. (All major MS / GI
supports to hold the stack is included in this item).
NS 110 mm dia. 6 kg/cm2 (Class III ) RM 50.00 1014.91 50745.50
7 NS 160 mm dia. 6 kg/cm2 (Class III ) RM 50.00 1736.98 86849.00
8 NS 200 mm dia. 6 kg/cm2 (Class III ) RM 10.00 2518.91 25189.10
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
9 Providing, fixing, jointing and testing UPVC soil, waste, vent
pipework comprising UPVC pipe conforming to IS :4985-
1983 of class 3 ( 6kg/cm2) as specified below and fittings
(moulded as well as fabricated) like elbows, bends, reducers,
threaded tail pieces, caps, suitable elbow with suitable
extension piece for drain point and other specials jointing
with cement solvent, chasing, cutting and making good the
walls & floors pipes laid in floors shall be encased with 40
mm thick concrete all around, complete in all respects
including testing of complete installation for cocealed drain
lines. (All major MS / GI supports to hold is included in this
NS 40 mm dia 6 kg/cm2 (Class III ) RM 10.00 323.98 3239.80
10 NS 50 mm dia 6 kg/cm2 (Class III ) RM 55.00 429.94 23646.70
11 Providing, fixing, jointing and testing UPVC soil, waste, vent
pipework comprising UPVC pipe conforming to IS :4985-
1983 of 10kg/cm2 as specified below and fittings (moulded
as well as fabricated) like elbows, bends, reducers, threaded
tail pieces, caps, suitable elbow with suitable extension piece
for drain point and other specials jointing with cement
solvent, chasing, cutting and making good the walls & floors
pipes laid in floors shall be encased with 40 mm thick
concrete all around, complete in all respects including testing
of complete installation for cocealed drain lines. (All major
supports to hold is included in this item)
13 NS Providing and fixing UPVC/SWR trap (Multi trap) of self
cleaning design as per IS:13592 : 1992 complete including
cost of cutting and making good the cutouts in walls and
floors etc.including cutting and making good the walls and
floors wherever required complete.
100 mm inlet and 75 mm outlet. Nos. 46.00 313.06 14400.76
14 NS Providing and fixing Heavy Class SS grating of approved
design including setting in floor with cement motor to match
with floor finish as per architect requirement suitable for
waster and FT, UT & FD.
15 NS Providing and fixing P.V.C. WC connector (straight or bend
type) with rubber lip ring. Including 110 mm dia PVC pipe /
bend of required length and proper connection with M seal Nos. 15.00 436.72 6550.80
to C.I. pipe complete as required.
D. EXTERNAL SEWAGE/ STORM WATER DRAINAGE.
1 Providing, fixing, jointing, testing and commissioning UPVC
(Class III) Soil, Waste & Rain Water Drainage pipes
conforming to IS:4985 cut to required lengths including all
necessary fittings and specials. UPVC fittings (moulded as
well as fabricated) like bends, tees, Y-tees, access pieces,
saddle pieces, cleanouts, adaptors for connections to other
materials, reducers and other specials including trenching,
refilling & testing of joints etc. Making proper connection
with cement solvent joint as per BIS / manufacturer, complete
as per direction of Engineer in Charge.
NS 110 mm dia 6 kg/cm2 (Class III ) RM 100.00 1105.98 110598.00
3 NS 200 mm dia 6 kg/cm2 (Class III ) RM 10.00 2629.32 26293.20
4 19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5
coarse sand : 10 graded stone aggregate 40 mm nominal size)
up to haunches of SW pipes including bed concrete as per
standard design :
6 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1
complete with C.I. grating brick masonry chamber with water
tight C.I. cover with frame of 300 x300 mm size (inside) the
weight of cover to be not less than 4.50 kg and frame to be not
less than 2.70 kg as per standard design:
19.4.1 100x100 mm size P type
19.4.1.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
7 19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1
cement : 4 coarse sand ) with R.C.C. top with 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size), foundation concrete 1:4:8 mix (1 cement : 4
coarse sand : 8 graded stone aggregate 40 mm nominal size),
inside plastering 12 mm thick with cement mortar 1:3 (1
cement : 3 coarse sand) finished with floating coat of neat
cement and making channels in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) finished with a floating coat of neat cement
complete as per standard design :
19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover
with frame (light duty) 455x610 mm internal dimensions, total
weight of cover and frame to be not less than 38 kg (weight of
cover 23 kg and weight of frame 15 kg) :
19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
8 19.7.2 Inside size 120x90 cm and 90 cm deep including C.I. cover
with frame (medium duty) 500 mm internal diameter, total
weight of cover and frame to be not less than 116 kg (weight
of cover 58 kg and weight of frame 58 kg) :
19.7.2.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
9 19.8 Extra for depth for manholes :
19.8.1 Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 Metre 3.00
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
11 19.9 Constructing brick masonry circular type manhole 0.91 m
internal dia at bottom and 0.56m dia at top in cement mortar
1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm
thick with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with a floating coat of neat cement, foundation
concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone
aggregate 40 mm nominal size), and making necessary
channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a
floating coat of neat cement, all complete as per standard
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-
20 grade designation) 560 mm internal diameter conforming
to I.S. 12592, total weight of cover and frame to be not less
than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2
19.9.1 coarse sand : 4 graded stone aggregate 20 mm nominal size)
including centering, shuttering all complete. (Excavation, foot
rests and 12mm thick cement plaster at the external surface
shall be paid for separately) :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
12 19.10 Extra depth for circular type manhole 0.91m internal dia (at
bottom) beyond 0.91 m to 1.67 m
19.10.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
E. MISCELLANEOUS ITEMS
Providing and fixing M.S. puddle flanges (fabricated of 750
mm long pipe pieces) to R.C.C. water tanks wall / slab. The
entire fitting shall be hot dipped galvanized (Flanges shall
confirm to BS10 Table E) .
NS 50 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x
100 mm plus dia of pipe).
NS 65 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x
100 mm plus dia of pipe).
NS 80 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x
100 mm plus dia of pipe).
NS 100 mm dia (Flanged ends MS plate 6 mm thick; 250 mm x
20 mm plus dia of pipe).
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
NS Providing, testing & commissioning of dial type pressure
gauge with pressure scale of 0 to 15 kg / cm2. Provision of
isolation cock suitable for pressure of 15 kg / cum2 shall be
included in cost.
WATER SUPPLY PUMPS
1 Providing, fixing, testing and commissioning of Horizontal
centrifugal pumps for pumping drinking water from sump to
overhead water tank, the pumps shall be made of CI casing, CI
Impeller, CS shaft & sleeve, Mechanical Seal connected to a
TEFC induction motor mounted on a common channel base
frame with coupling guard, motor to be suitable for 400/440
V, 3 Phase, 50 cycles AC power supply, including all
necessary accessories.
Cold Water Pump: Flushing
Cold Water Pump: Domsetic set 1.00 44859.17 44859.17
Capacity : 4.4 Litres / sec
Head : 12-36 Mtrs
Type of Pump : Horizonal Centrifugal pump
Total No. of Pump-2No.(1W+1S)
2 Providing, fixing, testing and commissioning of Horizontal
centrifugal pumps for pumping drinking water from sump to
overhead water tank, the pumps shall be made of CI casing, CI
Impeller, CS shaft & sleeve, Mechanical Seal connected to a
TEFC induction motor mounted on a common channel base
frame with coupling guard, motor to be suitable for 400/440
V, 3 Phase, 50 cycles AC power supply, including all
necessary accessories.
Cold Water Pump: Flushing
Cold Water Pump: Flushing set 1.00 27213.10 27213.10
Capacity : 3.9 Litres / sec
Head : 8-22 Mtrs
Type of Pump : Horizonal Centrifugal pump
Total No. of Pump-2No.(1W+1S)
FIRE FIGHTING SYSTEM
1 NS TERRACE PUMP
Supply, erection, testing and commissioning of Electrical
driven Terrace pump with all necessary valves and fittings
comprising as follows: Electrical motor driven pump capable
of delivering 450LPM at a head of 20Mtrs 7.5 HP mono block
to electrical motor fiited in a common base plate, coupling
and coupling guard complete.
MAKE : KIRLOSKAR
2 NS DOL STARTER
NS Supply, installation, testing and commissioning of motor
control panel for the Terrace pump for fire fighting including
all neccesssary control wiring with indication lamps and
3 NS POWER CABLE
NS Supply and Laying of below sized XLPE insulated PVC
sheathed Aluminium conductor armored cabling to the
incoming and outgoing of fire pump panel including necessary
termination, glanding, necessary connections etc
4 NS PRESSURE SWITCH
NS Supply, installation, testing and commissioning of industrial
type pressure switch having 1/4" BSP(F) complete as Nos. 1.00 1346.43 1346.43
Make: Danfoss/Indifss/Waree
5 NS PRESSURE GAUGE
NS Supply, installation, testing and commissioning of pressure
gauge with 0 to 12kg range 4" dia.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
NS Supply, erection, testing and commissioning of above ground
piping of approved make medium quality MS "C" class pipes
with branded malleable specials conforming to IS 1239 part 1
& 2 such as tees, elbows, unions, flanges, nipples etc.
including cutting, welding and painting the exposed pipes
with one coat of zinchromate primer and two coats of PO red
enamel paint. The pipes shall be supported suitably..
Make: Tata/Zindal
8 NS BUTTERFLY VALVE
NS Supply, installation, testing and commissioning of slim seal
type cast iron butterfly valves lever operated type with
necessary flanges, nuts, rubber gaskets and bolts complete
Make : Intervalve/Karthar/Advance
9 NON RETURN VALVE
NS Supply, installation, testing and commissioning of slim seal
type cast iron non-return valves with necessary
flanges,nuts,bolts and rubber gaskets complete.
Make : Intervalve/Karthar/Advance
10 NS HYDRANT VALVE
NS Supply, erection, testing and commissioning of single headed
Hydrant valve stainless steel with ISI mark as per the IS Nos. 4.00 5345.54 21382.16
specification fitted to 80mm dia pipe.
Make: Arihant/Newage/Essel
11 NS HOSE REEL SET
Supply, installation, testing and commissioning of First-aid
Hose Reel with MS construction spray painted in Post office
Red, conforming to IS 884 with up to date amendments,
complete with the following as required as per technical
specification(a) 30 m. long 20 mm (nominal internal dia water
hose Thermoplastic (Textile reinforced) Type-2 as per IS:
12585(b) 20 mm nominal internal ) dia gun metal globe valve
nozzle.(c) Drum and brackets for fixing the equipment's
on wall.(d) Connections from riser with 40 mm dia stop valve
(gun metal) M.S. Pipe
Make: Arihant/Newage/Monsher
12 NS HOSE BOX
NS Supply, installation, testing and commissioning of hose boxes
wall/pedestal type of size 600 x 250 x 400 mm made out of 18
gauge MS sheet steel with front side glass, locking
arrangement and painted with approved colour completed as
required and as per specifications.
13 NS FIRE HOSE
Supply, installation, testing and commissioning of 63 mm dia,
15 mtr. Long RRL hose pipe with 63 mm dia Male and
Female SS couplings duly binded with GI wire, rivets etc.
conforming to IS 636 (type-A) as required as per technical
Make: CRC/Newage
14 NS BRANCH PIPE
NS Supply, installation, testing and commissioning of 63 mm dia
Gun metal branch pipe with 20 mm (nominal internal
diameter) size SS nozzle conforming to IS 903, suitable for Nos. 4.00 1471.42 5885.68
instantaneous connection to interconnect hose pipe coupling
Make: Arihant/Newage/Swastik
15 NS FIRE BRIGADE INLET
NS Supply, installation, testing and commissioning of 3 way Fire
Brigade Inlet connection of 63 mm dia. built - in Gun metal
Non- return valves instantaneous coupling type arrangement
to be connected to wet riser main.
Make: Arihant/Newage/Swastik
16 NS GATE/BALL VALVE
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
NS Supply, installation, testing and commissioning of lever
operated 25mm dia Gate/ball valve conforming to IS
9890:1981 with forged body, brass/stainless steel ball and
shall be internally threaded to receive pipe connections .
Make: Zoloto/Sant/Keeto
17 NS AIR RELEASE VALVE
NS Supply, installation, testing and commissioning of gunmetal
air release valve 25 mm with necessary fittings etc. complete.
Make: Arihant/Karthar/Atom
18 NS ABC FIRE EXTINGUISHER
Supply and installation of ABC Stored pressure type Fire
Extinguisher 4 Kgs Capacity Mono Ammonium Phosphate
based Dry Chemical Powder as per IS 14609 with ISI Mark
for Fighting ABC Class of Fire, stored Pressure type of Mild
steel body pressurized by Nitrogen Gas. The Extinguisher
shall have pressure gaugefor indicating inside pressure with
opening and closing lever of squeeze grip type with tamper
proof seal, complete with wall bracket. The Extinguisher
should be manufactured strictly as per IS: 15683:2006 with
Make: Safex/Kanex/Bharat
19 NS CO2 FIRE EXTINGUISHER
Supply and installation of CO2 type fire extinguisher of 4.5
NS kg. Capacity complete with initial charges and installation Nos 4.00 5800.00 23200.00
Make: Safex/Kanex/Bharat
FIRE ALARM SYSTEM
1 NS MANUAL CALL POINT
Supply, installation, testing and commissioning of manual call
points break glass type with hammer & chain
Supply, installation, testing and commissioning of audio alarm
3 NS FIRE ALARM PANEL
Supply, installation, testing and commissioning of Control
NS Panel of 8 Zone complete with charger, rectifier, alarm Nos. 1.00 18500.00 18500.00
display with all other necessary attachments
Make : Ravel/ Aswin/Agni
Supply ,Installation, testing and commissioning of 1 Sq.mm
Make :Finolex /Havells/RR
Supply ,Installation, testing and commissioning of 20mm PVC
Supply Installation, testing and commissioning of 2 x 12V 7
Ah Battery for Panel
NS SIGN BOARDS
Supply & erection of Glow Sign Board made of 3mm thick
PVC foam board for each floor 12" x 4"
8 NS Supply & erection of Assembly Point sign board 16" x 16" No 1.00 1800.00 1800.00
9 Supply & erection of Fire route map drwing in A3 sheet with
plastic laminated
SUKHAPURAM SUB TOTAL - (A ) 76625959.33
LOCATION NO. 2 - SABARIMALAMIDWAY SHELTER AT MANIYANKODE (VIRI BLOCK)
ITEM UNIT QUANTITY RATE AMOUNT
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Boring, providing and installing bored cast-in-situ reinforced
cement concrete piles of grade M-25 of specified diameter and
length below the pile cap to carry a safe working load not less
than specified, excluding the cost of steel reinforcement but
including the cost of boring, with bentonite solution and
temporary casing of appropriate length for setting out and
1 20.2.4 removal of same and the length of the pile to be embedded in Metre 880.00 2321.07 2042541.60
the pile cap etc. all complete, including removal of excavated
earth with all lifts and leads (Length of pile for payment shall
be measured upto bottom of pile cap).
500 mm dia piles
Extra for providing richer mixes at all floor levels. Note: -
Excess/less cement over the specified cement content used is
payable/ recoverable separately. Providing M-30 grade
2 5.34.1 concrete instead of M-25 grade BMC/RMC. (Note: - Cement Cum 172.48 91.77 15828.58
content considered in M30 is at the rate 340 kg/cum).
Steel reinforcement for R.C.C work including straightening,
cutting, bending, placing in position and binding all complete
Thermo - Mechanically Treated bars of grade Fe-500D or
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
4 2.6.1 disposal of excavated earth, lead up to 50 m and lift up to 1.5 Cum 249.32 166.30 41462.08
m, disposed earth to be levelled and neatly dressed.
All kinds of soil
Vertical load testing of piles in accordance with IS 2911( Part
IV) including installation of loading platform and preparation
of pile head or construction of test cap and dismantling of test
cap after test etc. complete as per specification & the direction Per
Group of two or more piles upto 50 tonne capacity
Vertical load testing of piles in accordance with IS 2911( Part
IV) including installation of loading platform and preparation
of pile head or construction of test cap and dismantling of test
cap after test etc. complete as per specification & the direction Per
Single pile upto 50 tonne capacity
Providing and fixing pots for pillar slab including the cost of
7 NS all labour and material, transportation, loading Sqm 276.96 1336.29 370098.88
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
work up to plinth level:
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard
9 5.33.1 setting of concrete, improve workability without impairing Cum 210.85 8511.96 1794738.25
strength and durability as per direction of Engineer - in-
charge. Note:- Cement content considered in this item is @
330 kg/ cum. Excess or less cement used as per design mix is
payable or recoverable separately.
All work upto plinth level
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Steel reinforcement for R.C.C work including straightening,
cutting, bending, placing in position and binding all complete
Thermo - Mechanically Treated bars of grade Fe-500D or
Steel reinforcement for R.C.C work including straightening,
cutting, bending, placing in position and binding all complete
Thermo - Mechanically Treated bars of grade Fe-500D or
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard
12 5.33.2 setting of concrete, improve workability without impairing Cum 371.06 9572.97 3552165.39
strength and durability as per direction of Engineer - in-
charge. Note:- Cement content considered in this item is @
330 kg/ cum. Excess or less cement used as per design mix is
payable or recoverable separately.
All work above plinth level upto floor V level
Centering and Shuttering 0.00
Centering and shuttering including strutting, propping etc. and
5.9 removal of form for : 0.00
13 5.9.1 Foundations, footings, bases of columns, etc. for mass Sqm 375.78 256.09 96232.99
Walls (any thickness) including attached pilasters, butteresses,
14 5.9.2 plinth and string courses etc. Sqm 80.00 499.90 39992.00
15 5.9.3 Suspended floors, roofs, landings, balconies and access Sqm 1083.10 557.60 603936.56
16 5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 1752.22 452.77 793353.10
Columns, Pillars, Piers, Abutments, Posts and Struts.
Solid block masonry using pre cast solid blocks ( Factory
made) of size 30x20x20cm or nearest available
size confirming to IS 2185 Part I of 1979 for super structure
up to floor two level thickness 20cm and
above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory
made) of size 30x20x20cm or nearest available size
confirming to IS 2185 part I of 1979 for foundation and plinth
19 50.6.1.4 with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 Cum 71.28 5130.00 365666.40
coarse sand ) etc complete
Solid block masonry using pre cast solid blocks (Factory
made) of size 40x20x10 cm or nearest available
size confirming to IS 2185 part I of 1979 for super structure
20 50.6.3.2 up to floor two level for 10 cm thick wall in : Cum 29.46 6426.53 189325.57
CM 1:6 ( 1 cement : 6 coarse sand) including cost of
scaffolding complete
21 13.1.1 12mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Sqm 6123.11 228.36 1398272.71
6mm th Ceiling Plaster plaster of mix 1:3 (1 cement: 3 coarse
18 mm thick plain cement mortar band in cement mortar 1:4
(1 cement : 4 fine sand):
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and fixing I st quality ceramic glazed wall tiles
conforming to IS : 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades
except burgundy, bottle green, black of any size as approved
27 11.36 by Engineer -in-Charge, in skirting, risers of steps and dados, Sqm 408.53 983.43 401758.69
over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3 kg
per sqm, including pointing in white cement mixed with
pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS : 15622, of
approved make, in all colours and shades, laid on 20 mm thick
28 11.41.2 cement mortar 1:4(1 cement : 4 coarse sand), including Sqm 995.64 1478.06 1471621.57
grouting the joints with white cement and matching pigments
etc., complete.
Size of Tile 600 x 600 mm.
Providing and laying flamed finish Granite stone flooring in
required design and patterns, in linear as well as curvillinear
portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average)
thick base of cement mortar 1:4 (1 cement : 4 coarse sand)
laid and jointed with cement slurry and pointing with white
29 8.12 cement slurry admixed with pigment of matching shade Sqm 605.83 3813.18 2310127.40
including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-charge. a. Flamed
finish granite stone slab Jet Black, Cherry Red, Elite Brown,
Cat Eye or equivalent.
WATER PROOFING 0.00
Providing and laying water proofing treatment in sunken
portion of WCs, bathroom etc., by applying cement slurry
mixed with water proofing cement compound consisting of
applying : a) First layer of slurry of cement @ 0.488 kg/sqm
mixed with water proofing cement compound @ 0.253 kg/
sqm. This layer will be allowed to air cure for 4 hours. b)
30 22.5 Second layer of slurry of cement @ 0.242 kg/sqm mixed with Sqm 199.12 393.88 78429.39
water proofing cement compound @ 0.126 kg/sqm. This layer
will be allowed to air cure for 4 hours followed with water
curing for 48 hours. The rate includes preparation of surface,
treatment and sealing of all joints, corners, junctions of pipes
and masonry with polymer mixed slurry.
Providing and laying Ceramic glazed floor tiles of size
300x300 mm (thickness to be specified by the manufacturer),
of Ist quality conforming to IS : 15622, of approved make, in
all colours, shades, except White, Ivory, Grey, Fume Red
Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1
cement : 4 Coarse sand), including pointing the joints with
white cement and matching pigments etc., complete.
Applying one coat of water thinnable cement primer of
32 13.43.1 approved brand and manufacture on wall surface : Water Sqm 8254.61 48.79 402742.28
thinnable cement primer
Finishing walls with textured exterior paint of required shade
:New work (Two or more coats applied @ 3.28 ltr/10 sqm)
over and including priming coat of exterior primer applied @
Finishing walls with Acrylic Smooth exterior paint of required
shade : New work (Two or more coat applied @ 1.67 ltr/10
sqm over and including priming coat of exterior primer
applied @ 2.20 kg/10 sqm)
PAINTING Wall painting with premium acrylic emulsion
paint of interior grade, having VOC (Volatile Organic
Compound ) content less than 50 grams/ litre of
approvedbrand and manufacture, including applying
additional coats wherever required to achieve even shade and
colour. Two coats
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing wood work in frames of doors, windows, clerestory
windows and other frames, wrought framed and fixed in
position with hold fast lugs or with dash fasteners of required
dia & length (hold fast lugs or dash fastener shall be paid for
Second class teak wood
Providing and fixing panelled or panelled and glazed shutters
for shutters for doors, windows and
clerestory windows, including ISI marked M.S. pressed butt
37 9.5.1.1 hinges bright finished of required size with Sqm 28.80 3364.58 96899.90
necessery screws, excluding panelling which will be paid for
separately, all complete as per direction of
Engineer - in-charge.Second class teak wood35 mm thick
Providing and fixing panelling or panelling and glazing in
panelled or panelled and glazed shutters for doors, windows
and clerestory windows (Area of opening for panel inserts
excluding portion inside grooves or rebates to be measured).
Panelling for panelled or panelled and glazed shutters 25 mm
to 40 mm thick : Kiln seasoned and chemically treated hollock
wood. (1/3rd glazed and 2/3rd panelled)
Providing and fixing ISI marked flush door shutters
conforming to IS : 2202 (Part I) decorative type, core of block
board construction with frame of 1st class hard wood and well
39 9.20.1 matched teak 3 ply veneering with vertical grains or cross Sqm 81.36 3286.41 267382.32
bands and faceveneers on both faces of shutters. 35 mm thick
including ISI marked Stainless Steel butt hinges with
necessary screws.
Providing and fixing M.S. grills of required pattern in frames
40 9.48 of windows etc. with M.S. flats, square or round bars etc.
including priming coat with approved steel primer all
9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. Kg 1072.50 148.48 159245.39
Providing 40x5 mm flat iron hold fast 40 cm long including
fixing to frame with 10 mm diameter bolts, nuts and wooden
41 9.53 plugs and embedding in cement concrete block 30x10x15cm Each 464.00 156.60 72662.40
1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate
20mm nominal size)
Providing and fixing aluminium extruded section body tubular
type universal hydraulic door closer (having brand logo with
ISI, IS : 3564, embossed on the body, door weight upto 36 kg
to 80 kg and door width from 701 mm to 1000 mm), with
double speed adjustment with necessary accessories and
screws etc. complete.
Providing and fixing aluminium handles, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS :
1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper,
ISI marked, anodised (anodic coating not less
than grade AC 10 as per IS: 1868) transparent or dyed to
required colour and shade, with necessary
screws etc. complete.Twin rubber stopper
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and fixing factory made panel PVC door shutter
consisting of frame made out of M.S. tubes of 19 gauge
thickness and sized of 19 mm x 19 mm for styles and 15x15
mm for top & bottom rails. M.S. frame shall have a coat of
steel primers of approved make and manufacture. M.S. frame
covered with 5 mm thick heat moulded PVC 'C' channel of
size 30 mm thickness, 70 mm width out of whicj 50 mm shall
be flat and 20 mm shall be tapered in 45 degree angle on both
side forming styles and 5mm thick, 95 mm wide PVC sheet
out of which75 mm shall be tapered in 45 degree on th inner
side to form top and bottom rail and 115 mm wide PVC sheet
out of which 75 mm shall be flat and 20 mm shall be tapered
48 9.120.1 on both sides to form lock rail. Top, bottom and lock rails Sqm 63.15 3655.00 230816.91
shall be provided both side of the panel. 10 mm (5 mmx2)
thick, 20 mm wide cross PVC sheet be provided as gap insert
for top rail & bottom rail. paneling of 5 mm thick both side
PVC sheet to be fitted in the M.S. frame welded /sealed to the
styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide
PVC sheet beading on inner side, and joined together with
solvent cement adhesive. An additional 5 mm thick PVC strip
of 20 mm width is to be stuck on the interior side of the 'C'
Channel using PVC solvent adhesive etc. complete as per
direction of Engineer -in-charge, manufacture's specification
30 mm thick plain PVC door shutters
Providing and fixing factory made P.V.C. door frame of size
50x47 mm with a wall thickness of 5 mm, made out of
extruded 5 mm rigid PVC foam sheet, mitred at corners and
joined with 2 Nos. of 150 mm long brackets of 15x15 mm
M.S. square tube, the vertical door frame profiles to be
49 9.119 reinforced with 19x19 mm M.S. square tube of 19 gauge, Metre 191.50 579.33 110941.70
EPDM rubber gasket weather seal to be provided through out
the frame. The door fame to be fixed to the wall using M.S.
screws of 65/100 mm size, complete as per manufacturer's
specification and direction of Engineer-in Charge.
Providing and fixing aluminium sliding door bolts, ISI
marked anodised (anodic coating not less than grade AC 10 as
50 9.96.1 per IS : 1868), transparent or dyed to required colour or shade, Nos 57.00 280.52 15989.64
with nuts and screws etc. complete:
Providing and fixing aluminium sliding door bolts, ISI marked
anodised (anodic coating not less than grade AC 10 as per IS :
1868), transparent or dyed to required colour or shade, with
51 9.96.2 nuts and screws etc. complete: Nos 68.00 249.82 16987.76
Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard
tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS:1285, fixing
with dash fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at top, bottom
and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free,straight, mitred
and jointed mechanically wherever required including cleat
angle, Aluminium snap beading for glazing / paneling, C.P.
brass / stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) : For
fixed portion Anodised aluminium (anodised transparent or
dyed to required shade according to IS: 1868, minimum
anodic coating of grade AC 15)
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard
tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS : 733 and IS: 1285, fixing
with dash fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at top, bottom
and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred
53 21.1.1.2 and jointed mechanically wherever required including cleat kg 199.35 507.69 101208.00
angle, Aluminnium snap beading for glazing /paneling, C.P.
brass/ stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge.(Glazing,
paneling and dash fasteners to be paid for separately):
For fixed portion
Powder coated aluminium (minimum thickness of powder
coating 50 micron)
Providing and fixing glazing in aluminium door, window,
ventilator shutters and partitions etc. with EPDM
rubber / neoprene gasket etc. complete as per the architectural
54 21.3.1 drawings and the directions of Engineer - Sq.m 66.45 979.08 65059.87
in -Charge. ( Cost of aluminium snap beading shall be paid in
basic item):With float glass panes of 4.0
Steel work in built up tubular (round, square or rectangular
hollow tubes etc.)trusses etc., including cutting, hoisting,
fixing in position and applying a priming coat of approved
steel primer, including welding and bolted with special shaped
washers etc. complete. Hot finished welded type tubes.
loading and unloading, transportation, all lead and lift, etc.,
Providing and fixing stainless steel ( Grade 304) railing made
of Hollow tubes, channels, plates etc., including welding,
grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel
nuts and bolts complete, i/c fixing the railing with necessary
56 10.28 accessories & stainless steel dash fasteners , stainless steel Kg 1500.00 623.76 935640.00
bolts etc., of required size, on the top of the floor or the side
of waist slab with suitable arrangement as per approval of
Engineer-in-charge, (for payment purpose only weight of
stainless steel members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc.).
Painting with synthetic enamel paint of approved brand and
57 13.61.1 manufacture to give an even shade:Two or Sqm 2238.00 103.52 231677.76
more coats on new work
Supply and installation of GI puff sheet of thickness 150
mm for viri main roof including fasterning screw cost of
58 NS materials and labours, transportation, loading unloading, all Sqm 1310.89 2834.07 3715159.69
lead and lift, etc., complete as per design and instruction of
engineer in charge.
Providing & fixing on roof pressed clay tile (Mangalore tile)
of 20 mm nominal thickness and of approved size and as per
59 12.48 approved pattern on steel frame work complete (steel Sqm 1310.89 314.26 411960.92
framework to be paid separately)
Providing & laying on roof pressed clay tile ridge (Mangalore
tile) of 20 mm thickness and of approved pattern on steel
frame work complete (steel frame work to be paid separately
Fixing of ceiling kerala tiles below for car porch roof and
sunshades including labour, installation, transportation,
loading unloading, all lead and lift, scaffolding, etc., complete
as per drawing and instruction of engineer in charge.
Supply and fixing of eave board of 12mm thickness
including the cost of all material and labour, installation,
transportation, etc., complete ass per drawing and instruction
of engineer in charge.
MANIYANKODE VIRI SUB TOTAL - (B) 44097539.98
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
LOCATION 02- SABARIMALAMIDWAY SHELTER AT MANIYANCODE- ANNADHANAM
ITEM UNIT QUANTITY RATE AMOUNT
Boring, providing and installing bored cast-in-situ reinforced
cement concrete piles of grade M-25 of specified diameter and
length below the pile cap to carry a safe working load not less
than specified, excluding the cost of steel reinforcement but
including the cost of boring, with bentonite solution and
temporary casing of appropriate length for setting out and
1 20.2.4 removal of same and the length of the pile to be embedded in Metre 512.00 2321.07 1188387.84
the pile cap etc. all complete, including removal of excavated
earth with all lifts and leads (Length of pile for payment shall
be measured upto bottom of pile cap).
500 mm dia piles
Steel reinforcement for R.C.C work including straightening,
cutting, bending, placing in position and binding all complete
Thermo - Mechanically Treated bars of grade Fe-500D or
Vertical load testing of piles in accordance with IS 2911( Part
IV) including installation of loading platform and preparation
of pile head or construction of test cap and dismantling of test
cap after test etc. complete as per specification & the direction Per
of engineer -in-Charge. Test
Single pile upto 50 tonne capacity
Vertical load testing of piles in accordance with IS 2911( Part
IV) including installation of loading platform and preparation
of pile head or construction of test cap and dismantling of test
cap after test etc. complete as per specification & the direction Per
of engineer -in-Charge. Test
Single pile upto 50 tonne capacity
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8
graded stone aggregate 40 mm nominal size)
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
6 2.6.1 disposal of excavated earth, lead up to 50 m and lift up to 1.5 Cum 825.00 166.30 137197.50
m, disposed earth to be levelled and neatly dressed.
All kinds of soil
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
7 5.33.1 recommended proportions as per IS: 9103 to accelerate, retard Cum 128.66 8511.96 1095165.80
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
(Note: - cement content considered in this item is @
330kg/cum. Excess or less cement used as per design mix is
payable or recoverable separately.) All works upto plinth level
Steel reinforcement for R.C.C work including straightening,
8 5.22.6 cutting, bending, placing in position and kg 15874.80 74.73 1186323.80
binding all complete upto plinth levelThermo - Mechanically
Treated bars of grade Fe-500D or more
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundation etc. in layers not exceeding 20 cm
9 2.25 in depth, consolidating each deposited layer by ramming and Cum 526.05 166.04 87345.34
watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
10 5.33.2 finishing and reinforcement, including admixtures in Cum 106.69 9572.97 1021378.46
recommended proportions as per IS: 9103 to accelerate, retard
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer - in-
charge. Note:- Cement content considered in this item is @
330 kg/ cum. Excess or less cement used as per design mix is
payable or recoverable separately.
All work above plinth level upto floor V level
Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement content used is
payable/ recoverable separately.
Providing M-30 grade concrete instead of M-25 grade
BMC/RMC. (Note:- Cement content considered in M-30 is @
reinforcement for R.C.C work including straightening,
cutting, bending, placing in position and binding all complete
above plinth level.
12 5.22A.6 Thermo - Mechanically Treated bars of grade Fe-500D or Kg 37107.80 74.73 2773065.89
Centering and shuttering including strutting, propping etc. and
removal of form for :
Foundations, footings, bases of columns, etc. for mass
Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal
15 5.9.5 of form for:Lintels, beams, plinth beams, Sqm 977.73 452.77 442688.62
girders bressumers and cantilevers
Centering and shuttering including strutting, etc. and removal
16 5.9.6 of form for:Columns, Pillars, Piers, Sqm 419.08 617.75 258886.05
Abutments, Posts and Struts
Solid block masonry using pre cast solid blocks ( Factory
made) of size 30x20x20cm or nearest available
17 50.6.1.5 size confirming to IS 2185 Part I of 1979 for super structure Cum 194.70 5589.76 1088309.50
up to floor two level thickness 20cm and
above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory
made) of size 30x20x20cm or nearest available size
18 50.6.1.4 confirming to IS 2185 part I of 1979 for foundation and plinth Cum 71.28 5130.00 365666.40
with thickness 20cm and above in: CM 1:6 ( 1 cement : 6
coarse sand ) etc complete
Solid block masonry using pre cast solid blocks (Factory
made) of size 40x20x10 cm or nearest available
size confirming to IS 2185 part I of 1979 for super structure
up to floor two level for 10 cm thick wall in :
CM 1:6 ( 1 cement : 6 coarse sand) including cost of
scaffolding complete
20 13.1.1 12mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Sq.m 3483.45 228.36 795481.33
18 mm thick plain cement mortar band in cement mortar 1:4
(1 cement : 4 fine sand):
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and laying vitrified floor tiles in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid on 20mm thick
25 11.41.2 cement mortar 1:4 (1 cement : 4 coarse sand), jointing with Sqm 555.51 1478.06 821075.63
grey cement slurry @ 3.3 kg/ sqm including grouting the
joints with white cement and matching pigments etc.,
complete. Size of tile 600x600 mm
Providing and laying Anti skid ceramic floor tiles of size
300x300 mm (thickness to be specified by the manufacturer),
of 1st quality conforming to IS : 15622, of approved make, in
all colours, shades, except White, Ivory, Grey, Fume Red
26 11.38 Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Sq.m 33.29 987.53 32874.87
Cement : 4 Coarse sand), jointing with grey cement slurry @
3.3 kg/ sq.m including pointing the joints with white cement
and matching pigments etc., complete.
Providing and fixing I st quality ceramic glazed wall tiles
conforming to IS : 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades
except burgundy, bottle green, black of any size as approved
27 11.36 by Engineer -in-Charge, in skirting, risers of steps and dados, Sqm 98.44 983.43 96811.80
over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3 kg
per sqm, including pointing in white cement mixed with
pigment of matching shade complete.
Providing and laying flamed finish Granite stone flooring in
required design and patterns, in linear as well as curvilinear
portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm
(average) thick base of cement mortar 1:4 (1 cement : 4 coarse
sand) laid and jointed with cement slurry and pointing with
28 8.12 white cement slurry admixed with pigment of matching shade Sqm 191.47 3813.18 730121.01
including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge : Flamed
finish granite stone slab Jet Black, Cherry Red, Elite Brown,
Cat Eye or equivalent.
Applying one coat of water thinnable cement primer of
29 13.43.1 approved brand and manufacture on wall surface : Water Sqm 3483.45 48.79 169957.67
thinnable cement primer
PAINTING Wall painting with premium acrylic emulsion
paint of interior grade, having VOC (Volatile Organic
30 13.83.2 Compound ) content less than 50 grams/ litre of Sqm 2557.57 93.75 239772.28
approvedbrand and manufacture, including applying
additional coats wherever required to achieve even shade and
colour. Two coats
Finishing walls with textured exterior paint of required shade
:New work (Two or more coats applied @ 3.28 ltr/10 sqm)
over and including priming coat of exterior primer applied @
Finishing walls with Acrylic Smooth exterior paint of required
shade : New work (Two or more coat applied @ 1.67 ltr/10
sqm over and including priming coat of exterior primer
applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and
33 13.61.1 manufacture to give an even shade:Two or Sqm 2238.00 103.52 231677.76
more coats on new work
Providing and fixing ISI marked flush door shutters
conforming to IS : 2202 (Part I) decorative type, core of block
board construction with frame of 1st class hard wood and well
34 9.20.1 matched teak 3 ply veneering with vertical grains or cross Sqm 28.80 3286.41 94648.61
bands and faceveneers on both faces of shutters. 35 mm thick
including ISI marked Stainless Steel butt hinges with
necessary screws.
Providing and fixing M.S. grills of required pattern in frames
35 9.48 of windows etc. with M.S. flats, square or round bars etc.
including priming coat with approved steel primer all
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. Kg 634.95 148.48 94277.38
Providing 40x5 mm flat iron hold fast 40 cm long including
fixing to frame with 10 mm diameter bolts, nuts and wooden
36 9.53 plugs and embedding in cement concrete block 30x10x15cm each 138.00 156.60 21610.80
1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate
20mm nominal size)
Providing and fixing aluminium extruded section body tubular
type universal hydraulic door closer (having brand logo with
ISI, IS : 3564, embossed on the body, door weight upto 36 kg
37 9.84 to 80 kg and door width from 701 mm to 1000 mm), with each 14.00 512.84 7179.76
double speed adjustment with necessary accessories and
screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS :
1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper,
ISI marked, anodised (anodic coating not less than grade AC
10 as per IS : 1868) transparent or dyed to required colour and
shade, with necessary screws etc. complete.
9.101.2 Twin rubber stopper each 18.00 50.18 903.24
Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard
tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS:1285, fixing
with dash fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at top, bottom
and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free,straight, mitred
and jointed mechanically wherever required including cleat
angle, Aluminium snap beading for glazing / paneling, C.P.
brass / stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid separately) : For fixed
portion Anodised aluminium (anodised transparent or dyed to
required shade according to IS - 1868, minimum anodic
coating of grade AC 15).
For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision for
fixing of fittings whereever required including the cost of
44 21.1.2.1 EPDM rubber / neoprene gasket required (fitting shall paid for kg 112.05 548.03 61406.76
separately). Anodised aluminium (anodised transparent or
dyed to required shade according to IS: 1868, minimum
anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window,
ventilator shutters and partitions etc. with EPDM
rubber / neoprene gasket etc. complete as per the architectural
45 21.3.1 drawings and the directions of Engineer - Sqm 37.35 979.08 36568.64
in -Charge. ( Cost of aluminium snap beading shall be paid in
basic item):With float glass panes of 4.0
Providing wood work in frames of doors, windows, clerestory
windows and other frames, wrought framed and fixed in
position with hold fast lugs or with dash fasteners of required
dia & length (hold fast lugs or dash fastener shall be paid for
Second class teak wood
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and fixing aluminium sliding door bolts, ISI marked
anodised (anodic coating not less than grade AC 10 as per IS :
47 9.96 1868), transparent or dyed to required colour or shade, with
nuts and screws etc. complete :
Providing and fixing factory made P.V.C. door frame of size
50x47 mm with a wall thickness of 5 mm, made out of
extruded 5 mm rigid PVC foam sheet, mitred at corners and
joined with 2 Nos. of 150 mm long brackets of 15x15 mm
M.S. square tube, the vertical door frame profiles to be
48 9.119 reinforced with 19x19 mm M.S. square tube of 19 gauge, metre 14.85 579.33 8603.63
EPDM rubber gasket weather seal to be provided through out
the frame. The door fame to be fixed to the wall using M.S.
screws of 65/100 mm size, complete as per manufacturer's
specification and direction of Engineer-in Charge.
Providing and fixing factory made panel PVC door shutter
consisting of frame made out of M.S. tubes of 19 gauge
thickness and sized of 19 mm x 19 mm for styles and 15x15
mm for top & bottom rails. M.S. frame shall have a coat of
steel primers of approved make and manufacture. M.S. frame
covered with 5 mm thick heat moulded PVC 'C' channel of
size 30 mm thickness, 70 mm width out of whicj 50 mm shall
be flat and 20 mm shall be tapered in 45 degree angle on both
side forming styles and 5mm thick, 95 mm wide PVC sheet
out of which75 mm shall be tapered in 45 degree on th inner
side to form top and bottom rail and 115 mm wide PVC sheet
out of which 75 mm shall be flat and 20 mm shall be tapered
49 9.120.1 on both sides to form lock rail. Top, bottom and lock rails Sqm 4.73 3655.00 17273.53
shall be provided both side of the panel. 10 mm (5 mmx2)
thick, 20 mm wide cross PVC sheet be provided as gap insert
for top rail & bottom rail. paneling of 5 mm thick both side
PVC sheet to be fitted in the M.S. frame welded /sealed to the
styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide
PVC sheet beading on inner side, and joined together with
solvent cement adhesive. An additional 5 mm thick PVC strip
of 20 mm width is to be stuck on the interior side of the 'C'
Channel using PVC solvent adhesive etc. complete as per
direction of Engineer -in-charge, manufacture's specification
30 mm thick plain PVC door shutters
Providing and fixing panelled or panelled and glazed shutters
for shutters for doors, windows and
clerestory windows, including ISI marked M.S. pressed butt
50 9.5.1.1 hinges bright finished of required size with Sqm 9.60 3364.58 32299.97
necessery screws, excluding panelling which will be paid for
separately, all complete as per direction of
Engineer - in-charge.Second class teak wood 35 mm thick
Providing and fixing panelling or panelling and glazing in
panelled or panelled and glazed shutters for doors, windows
and clerestory windows (Area of opening for panel inserts
51 9.7.1 excluding portion inside grooves or rebates to be measured). Sqm 9.60 2689.72 25821.31
Panelling for panelled or panelled and glazed shutters 25 mm
to 40 mm thick : Second class teak wood
Providing and fixing stainless steel ( Grade 304) railing made
of Hollow tubes, channels, plates etc., including welding,
grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel
nuts and bolts complete, i/c fixing the railing with necessary
52 10.28 accessories & stainless steel dash fasteners , stainless steel Kg 1500.00 623.76 935640.00
bolts etc., of required size, on the top of the floor or the side
of waist slab with suitable arrangement as per approval of
Engineer-in-charge, (for payment purpose only weight of
stainless steel members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc.).
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Steel work in built up tubular (round, square or rectangular
hollow tubes etc.)trusses etc., including cutting, hoisting,
fixing in position and applying a priming coat of approved
53 10.16.1 steel primer, including welding and bolted with special shaped Kg 57131.67 119.17 6808380.76
washers etc. complete. Hot finished welded type tubes.
loading and unloading, transportation, all lead and lift, etc.,
EXTERIOR WALL CLADDING: Providing and fixing
laterite exterior cladding including the cost of all materials
and labour charges, scaffolding etc. complete as per drawing
and instruction of engineer in charge.
Supply and installation of GI puff sheet of thickness 100
mm for annadhanamandapam main roof including
55 NS fasterning screw cost of materials and labours, transportation, Sqm 950.00 2834.06 2692357.00
loading unloading, all lead and lift, etc., complete as per
design and instruction of engineer in charge.
Providing & fixing on roof pressed clay tile (Mangalore tile)
of 20 mm nominal thickness and of approved size and as per
approved pattern on steel frame work complete., loading and
unloading, transportation, all lead and lift, etc., complete
(steel frame work to be paid separately)
Providing & laying on roof pressed clay tile ridge (Mangalore
57 12.49 tile) of 20 mm thickness and of approved pattern on steel Rm 160.00 69.25 11080.00
frame work complete (steel frame work to be paid separately
Fixing of ceiling kerala tiles below for car porch roof and
sunshades including labour, installation, transportation,
58 MR loading unloading, all lead and lift, scaffolding, etc., complete Sqm 50.00 773.56 38678.00
as per drawing and instruction of engineer in charge.
Supply and fixing of eave board of 12mm thickness
including the cost of all material and labour, installation,
transportation, etc., complete ass per drawing and instruction
of engineer in charge.
Earth work in Excavation by mechanical means (hydraulic
excavator)/ manual means in foundation trenches or drains
(not exceeding 1.5 metre in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto
1.5 metre, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of
All kinds of soil.
Extra for every additional lift of 1.5 m or part thereof in
61 2.26.1 excavation /banking excavated or stacked materials. Cum 86.06 68.33 5880.68
All kinds of soil
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm
62 2.25 in depth, consolidating each deposited layer by ramming and Cum 232.43 166.04 38591.85
watering, lead up to 50 m and lift upto 1.5m.
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
63 4.1.8 work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 Cum 4.20 5912.95 24834.39
graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
64 5.33.1 finishing and reinforcement, including admixtures in Cum 5.60 8511.96 47649.95
recommended proportions as per IS: 9103 to accelerate, retard
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
All works upto to plinth level
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement
content used is payable/ recoverable separately.Providing M-
30 grade concrete instead of M-25 grade
BMC/RMC. (Note:- Cement content considered in M-30 is @
Centering and Shuttering
Centering and shuttering including strutting, propping etc. and
removal of form for :
Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level.Thermo-Mechanically Treated bars of grade
Fe-500D or more.
69 13.1.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) sqm 259.20 228.36 59190.91
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in
70 5.33.2 recommended proportions as per IS: 9103 to accelerate, retard Cum 5.64 9572.97 53981.98
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer - in-
charge. Note:- Cement content considered in this item is @
330 kg/ cum. Excess or less cement used as per design mix is
payable or recoverable separately.
All work above plinth level upto floor V level
Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement
content used is payable/ recoverable separately.Providing M-
30 grade concrete instead of M-25 grade
BMC/RMC. (Note:- Cement content considered in M-30 is @
Centering and shuttering including strutting, etc. and removal
72 5.9.2 of form for:Walls (any thickness) including attached pilasters, Sqm 51.98 499.90 25985.80
butteresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal
73 5.9.3 of form for:Suspended floors, roofs, Sqm 17.42 557.60 9713.39
landings, balconies and access platform
Steel reinforcement for R.C.C work including straightening,
cutting, bending, placing in position andbinding all complete
upto plinth level Thermo - Mechanically Treated bars of grade
Fe-500D or more
75 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) Sqm 72.44 228.36 16542.86
Earth work in excavation by mechanical means (Hydraulic
excavator) /manual means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, lift up to 1.5 m,
including getting out the excavated soil and disposal of
surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Extra for every additional lift 1.5 m or part there of in
77 2.26.1 excavation / banking excavated or stacked materials.All kinds Cum 119.15 68.33 8141.18
Filling available excavated earth (excluding rock) in trenches,
78 2.25 plinth, sides of foundation etc. in layers not exceeding 20 cm Cum 71.22 166.04 11825.37
in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift up to 1.5 m.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8
graded stone aggregate 40 nominal size)
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix,including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
80 5.33.1 finishing and reinforcement, including admixtures in Cum 64.20 8511.96 546501.88
recommended proportions as per IS: 9103 to accelerate,retard
setting of concrete, improve workability without impairing
strength and durability as per direction ofEngineer - in-charge.
Note:- Cement content considered in this item is @ 330 kg/
cum. Excess or lesscement used as per design mix is payable
or recoverable separately.All work upto plinth level
Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement
content used is payable/ recoverable separately.Providing M-
30 grade concrete instead of M-25 grade
BMC/RMC. (Note:- Cement content considered in M-30 is @
Centering and shuttering including strutting, etc. and removal
of form for:Walls (any thickness) includingattached pilasters, Sqm 284.58 499.90 142262.54
82 5.9.2 butteresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal
83 5.9.3 of form for:Suspended floors, roofs, Sqm 90.83 557.60 50646.81
landings, balconies and access platform
Steel reinforcement for R.C.C work including straightening,
cutting, bending, placing in position andbinding all complete
upto plinth levelThermo - Mechanically Treated bars of grade
Fe-500D or more
85 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) Sqm 198.83 228.36 45404.82
Banking excavated earth in layers not exceeding 20 cm in
depth, breaking clods, watering, rolling each layer with ½
tonne roller, or wooden of steel rammers, and rolling every
86 2.3 3rd and top-most layer with power roller of minimum 8 tonnes
and dressing up, in embankments for roads, flood banks,
marginal banks, and guide banks etc., lead upto 50 m and lift
2.3.1 All kinds of soil Cum 240.00 356.18 85483.20
Preparation and consolidation of sub grade with power road
roller of 8 to 12 tonne capacity after excavating earth to an
87 16.1 average of 22.5 cm depth, dressing to camber and Sqm 800.00 118.97 95176.00
consolidating with road roller including making good the
undulations etc. and re-rolling the sub grade and disposal of
surplus earth with
Construction lead upto
of granular 50 metres.
sub-base by providing close graded
Material conforming to specifications, mixing in a mechanical
mix plant at OMC, carriage of mixed material by tippers to
work site, for all leads & lifts, spreading in uniform layers of
88 16.78 specified thickness with motor grader on prepared surface and
compacting with vibratory power roller to achieve the desired
density, complete as per specifications and directions of
Engineer in-Charge.
With material conforming to Grade-I (size range 75 mm to
0.075 mm) having CBR Value-30
Providing, laying, spreading and compacting graded stone
aggregate (size range 53 mm to 0.075 mm ) to wet mix
macadam (WMM) specification including premixing the
material with water at OMC in for all leads & lifts, laying in
89 16.79 uniform layers with mechanical paverfinisher in sub- base / cum 160.00 2815.42 450467.20
base course on well prepared surface and compacting with
vibratory roller of 8 to 10 tonne capacity to achievethe desired
density, complete as per specifications and directions of
Engineer-in-Charge.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Tack Coat - RS Bitumen Emulsion - On W.B.M / W.M.M @
0.4 kg/ sqm Providing and applying tack coat using bitumen
emulsion conforming to IS : 8887, using emulsion
90 51.16.31.1.1 pressure distributor including preparing the surface & Sqm 800.00 18.77 15016.00
cleaning with mechanical broom.
1. With Rapid Setting Bitumen Emulsion
1. On W.B.M / W.M.M @ 0.4 kg/ sqm
Tack Coat - RS Bitumen Emulsion - On bituminous surface @
Providing and applying tack coat using bitumen emulsion
conforming to IS : 8887, using emulsion
91 51.16.31.1.2 pressure distributor including preparing the surface & Sqm 1600.00 12.36 19776.00
cleaning with mechanical broom.
1. With Rapid Setting Bitumen Emulsion
2. On bituminous surface @ 0.25 kg /sqm
2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum
of stone chippings of<br>13.2 mm and 11.2
mm size respectively per 100 sqm and 52 kg and 56 kg of
hot<br>bitumen per cum of stone chippings of
13.2 mm and 11.2 mm size respectively,<br>including a tack
coat with hot straight run bitumen, including
92 NS consolidation with<br>road roller of 6 to 9 tonne capacity etc. Sqm 800.00 233.95 187160.00
complete (tack coat to be paid for
separately).<br>With paving Asphalt grade VG - 10 heated
and then mixed with solvent at the<br>rate of
70 grams per kg of asphalt (Refer Item No. 16.33.1 DAR 2016
Providing and laying Bituminous Macadam using crushed
stone aggregate of specified grading premixed with
bituminous binder, transported to site by tipper, laid over a
precisely prepared surface with paver finisher equipped with
93 electronic sensor to the required grade level and alignment
and rolling with smooth wheeled vibratory and tandem rollers
as per specifications to achieve the desired compaction and
density, complete as per specifications and directions of
Engineer in charge.
50 to 100 mm average compacted thinkness with bitumen of
grade VG - 30 @ 3.50% (percentage by weight of total mix)
prepared in batch type hot mix plant of 100-120 TPH cum 40 7873.15 314926.00
capacity. (item no. 16.55.1 dsr 2016)
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
disposal of excavated earth, lead up to 50 m and lift up to 1.5
m, disposed earth to be levelled and neatly dressed.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm
in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5m.
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8
graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
97 5.33.1 finishing and reinforcement, including admixtures in Cum 17.28 8511.96 147086.67
recommended proportions as per IS: 9103 to accelerate, retard
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
upto Plinth level
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
98 5.33.2 finishing and reinforcement, including admixtures in Cum 10.80 9572.97 103388.08
recommended proportions as per IS: 9103 to accelerate, retard
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level.Thermo-Mechanically Treated bars of grade
Fe-500D or more.
Centering and Shuttering
Centering and shuttering including strutting, propping etc. and
removal of form for :
Foundations, footings, bases of columns, etc. for mass
101 13.1.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Sqm 312.00 228.36 71248.32
Finishing with Deluxe Multi surface paint system for interiors
and exteriors using Primer as per manufacturers
102 13.48.1 specifications. Two or more coats applied on walls @ 1.25 Sqm 312.00 130.65 40762.80
ltr/10 sqm over and including one coat of Special primer
applied @ 0.75 ltr /10 sqm
Solid block masonry using pre cast solid blocks ( Factory
made) of size 30x20x20cm or nearest available size
103 50.6.1.5 confirming to IS 2185 Part I of 1979 for super structure up to Cum 31.201 5589.76 174406.10
floor two level thickness 20cm and above in: CM 1:6 ( 1
cement : 6 coarse sand) etc complete
Steel work in built up tubular (round, square or rectangular
hollow tubes etc.)trusses etc., including cutting, hoisting,
fixing in position and applying a priming coat of approved
steel primer, including welding and bolted with special shaped
washers etc. complete. Hot finished welded type tubes.
loading and unloading, transportation, all lead and lift, etc.,
Earth work in excavation by mechanical means (Hydraulic
excavator) /manual means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, lift up to 1.5 m,
including getting out the excavated soil and disposal of
surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in
106 2.26.1 excavation /banking excavated or stacked materials. Cum 83.66 68.33 5716.49
All kinds of soil
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm
in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5m.
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8
graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and
machine mixed design mix M-25 grade cement concrete for
reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
109 5.33.1 finishing and reinforcement, including admixtures in Cum 42.21 8511.96 359281.32
recommended proportions as per IS: 9103 to accelerate, retard
setting of concrete, improve workability without impairing
strength and durability as per direction of Engineer-in-charge.
All works Upto Plinth level
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement
110 5.34.1 content used is payable/ recoverable separately.Providing M- Cum 41.74 91.77 3830.30
30 grade concrete instead of M-25 grade
Centering and Shuttering
Centering and shuttering including strutting, propping etc. and
removal of form for :
Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level.Thermo-Mechanically Treated bars of grade
Fe-500D or more.
Solid block masonry using pre cast solid blocks ( Factory
made) of size 30x20x20cm or nearest available
size confirming to IS 2185 Part I of 1979 for super structure
up to floor two level thickness 20cm and
above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
115 13.1.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Sqm 418.77 228.36 95631.00
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45
cm dry brick honey comb shaft with bricks and S.W. drain
116 19.32.1 pipe 100 mm diameter, 1.8 m long complete as per standard Nos 1.00 27307.85 27307.85
design. With common burnt clay F.P.S. (non modular) bricks
of class designation 7.5
PLUMBING WORKS - GUEST HOUSE BUILDING
A. SUB HEAD - I : SANITARY FIXTURES & FITTINGS:
1 17.3 Providing and fixing white vitreous china pedestal type water
closet (European type) with seat and lid, 10 litre low level
white vitreous china flushing cistern & C.P. flush bend with
fittings & C.I. brackets, 40 mm flush bend, overflow
arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete,
including painting of fittings and brackets, cutting and making
good the walls and floors wherever required :
17.3.1 W.C. pan with ISI marked white solid plastic seat and lid Nos. 29.00 6065.59 175902.11
2 17.5.1 Providing and fixing white vitreous china flat back half stall
urinal of size 580x380x350 mm with white PVC automatic
flushing cistern, with fittings, standard size C.P. brass flush
pipe, spreaders with unions and clamps (all in C.P. brass) with
waste fitting as per IS : 2556, C.I. trap with outlet grating and Nos. 7.00 8169.84 57188.88
other couplings in C.P. brass, including painting of fittings
and cutting and making good the walls and floors wherever
Single half stall urinal with 5 litre PVC. automatic flushing
Providing & Fixing white glazed vitreous china urinal
partitions of approved make including rawl plugs, screws or
any other approved device for fixing arrangements, making
holes in walls, floors & making good.
4 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm
C.P. brass pillar taps, 32 mm C.P. brass waste of standard
pattern, including painting of fittings and brackets, cutting and
making good the walls wherever require:
17.7.4 White Vitreous China Flat back wash basin size 550x400 mm
with single 15 mm C.P. brass pillar tap
5 17.22.A Providing and fixing CP Brass 32mm size Bottle Trap of
approved quality & make and as per the direction of Engineer-
6 17.16.A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible
tube upto 1 metre long with S.S. triangular plate to Eureopean Nos. 29.00 336.44 9756.76
type W.C. of quality and make as approved by Engineer - in -
7 17.22.B Providing and fixing CP Brass Single lever telephonic wall
mixer of quality & make as approved by Engineer in charge.
8 18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
9 17.73 Providing and fixing PTMT towel rail complete with brackets
fixed to wooden cleats with CP brass screws with concealed
fittings arrangement of approved quality and colour.
17.73.2 600 mm long towel rail with total length of 645 mm, width 78
mm and effective height of 88 mm, weighing not less than 190
10 17.34 Providing and fixing toilet paper holder :
11 NS Providing and fixing CP brass twin coat hook. No. 29.00 935.00 27115.00
12 17.71 Providing and fixing PTMT liquid soap container 109 mm
wide, 125 mm high and 112 mm distance from wall of
standard shape with bracket of the same materials with snap Nos. 2.00 182.02 364.04
fittings of approved quality and colour, weighing not less than
13 18.50 Providing and fixing C.P. brass long nose bib cock of
approved quality conforming to IS standards and weighing not
less than 810 gms.
14 18.52 Providing and fixing C.P. brass stop cock (concealed) of
standard design and of approved make conforming to IS:8931.
Providing and fixing C.P. brass angle valve for basin mixer
and geyser points of approved quality conforming to IS:8931
Providing and fixing 600x450 mm beveled edge mirror of
superior glass (of approved quality) complete with 6 mm thick
hard board ground fixed to wooden cleats with C.P. brass
screws and washers complete.
Providing and fixing complete set of sanitary fixtures for
handicapped toilets, make of Cera "Crane" / Hindware Cat.
no. 70002) / or approved equivalent comprising of EWC - P,
17 NS Cistern, Seat Cover, Twin Flush Fittings, Wash Basin Nos. 4.00 30763.37 123053.48
450x300, Half pedestal, 1 faucet with spatula lever, 1 hinged
rail and 2 grab bars, including cutting and making good the
walls and floors wherever required complete as per directions
of Engineerand
Providing in charge.
fixing uplasticised PVC connection pipe with
18.21.1 30 cm length
Providing and fixing PTMT Soap Dish Holder having length
of 138 mm, breadth 102 mm, height of 75 mm
with concealed fittings arrangements, weighing not less than
B. SUB HEAD - II : COLD / HOT / FLUSHING WATER
SUPPLY (INTERNAL / EXTERNAL):
20 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, including
fixing the pipe with clamps at 1.00 m spacing. This includes
jointing of pipes & fittings with one step CPVC solvent
cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall
18.7.3 25 mm nominal outer dia Pipes RM 350.00 285.47 99914.50
21 18.7.4 32 mm nominal outer dia Pipes RM 150.00 381.66 57249.00
22 18.7.5 40 mm nominal outer dia Pipes RM 60.00 509.01 30540.60
23 18.7.6 50 mm nominal outer dia Pipes RM 150.00 724.31 108646.50
24 NS 63 mm nominal outer dia Pipes RM 180.00 981.00 176580.00
25 NS 62.5 mm nominal outer dia Pipes RM 70.00 981.00 68670.00
26 NS 75 mm nominal outer dia Pipes RM 100.00 1210.00 121000.00
27 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, i/c fixing
the pipe with clamps at 1.00 m spacing. This includes jointing
of pipes & fittings with one step CPVC solvent cement and
the cost of cutting chases and making good the same including
testing of joints complete as per direction of Engineer in
Concealed work, including cutting chases and making good
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
30 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply
including all CPVC plain & brass threaded fittings This
includes jointing of pipes & fittings with one step CPVC
solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge.
18.9.3 25 mm nominal outer dia Pipes RM 20.00 253.05 5061.00
31 18.9.4 32 mm nominal outer dia Pipes RM 20.00 330.83 6616.60
32 18.9.5 40 mm nominal outer dia Pipes RM 10.00 424.05 4240.50
33 18.9.6 50 mm nominal outer dia Pipes RM 10.00 639.40 6394.00
34 18.9.7 62.50 mm nominal outer dia Pipes RM 130.00 1428.34 185684.20
35 18.9.8 75 mm nominal outer dia Pipes RM 100.00 1585.87 158587.00
36 18.9.9 100 mm nominal outer dia Pipes RM 10.00 2136.54 21365.40
37 NS 63 mm nominal outer dia Pipes RM 10.00 898.00 8980.00
38 Supplying, laying/ fixing, testing and commissioning of
following of duly insulated with following closed cell
elastometric nitrile rubber of minimum 45 Kg / cu m
density, thermal conductivity 0.037 W/MK or better at 20 deg
mean temperature class ‘O’ insulation applied by suitable
rubber based adhesive complete and as per specifications and
NS as required
mm dia (19 in all
mm thick respect.
nitrile rubber insulation) RM 100.00 83.00 8300.00
39 NS 25 mm dia (19 mm thick nitrile rubber insulation) RM 120.00 89.01 10681.20
40 NS 32 mm dia (19 mm thick nitrile rubber insulation) RM 50.00 98.00 4900.00
41 NS 40 mm dia (19 mm thick nitrile rubber insulation) RM 50.00 108.00 5400.00
42 NS 50 mm dia (19 mm thick nitrile rubber insulation) RM 70.00 124.00 8680.00
43 NS 65 mm dia (19 mm thick nitrile rubber insulation) RM 10.00 127.00 1270.00
Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) :
Providing and fixing Butterfly valve (upto 150mm dia with
band lever operation & above with gear box operation) with
51 NS SS-304 disc. Tested to a pressure not less than 15 Kg/sq.cm
including rubber gaskets, flanges, nuts, bolts, washers &
painting complete as required.
52 NS Providing & fixing Auto Air vent for cold / hot water supply
risers, suitable for pressure not less than 15 Kg/Sq.cm.
53 18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick
work in cement mortar 1:4 (1 cement : 4 coarse sand) for
sluice valve, with C.I. surface box 100mm top diameter, 160
mm bottom diameter and 180 mm deep ( inside) with chained
lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size ) , i/c necessary
excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
12 mm thick, finished with a floating coat of neat cement
complete as per standard design :
18.33.1 With common burnt clay F.P.S.(non modular) bricks of class
designation 7.5
C. SUB HEAD - III : INTERNAL DRAINAGE (SOIL,
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
54 NS Providing, jointing, testing and fixing UPVC Soil, Waste &
Vent system conforming to IS : 13592 Type B and UPVC
fittings (moulded as well as fabricated) like bends, tees, Y-
tees, crosses, boss connections, access pieces, saddle pieces,
cleanouts, adaptors for connections to other materials, plugs,
reducers, cowls, offset and other specials, jointing done with
solvent cement for fittings and specials, fixing inside sunken
slab / suspended below RCC slab for concealed soil and waste
lines, making proper connection and also pipes may be laid /
fixed in sunken floors, under hung from ceiling. The pipes
laid in sunken floor shall be supported with cement concrete
(1:2:4) blocks and under hung lines shall be supported from
slab with universal clamps. The installation shall be complete
in all respects including cutting chases / holes in walls, slabs
and making good the same as per specifications. (All GI pipe
supports to hold the pipes is included in this item).
56 NS Providing, jointing, testing and fixing UPVC Soil, Waste &
Vent system conforming to IS : 13592 Type B and UPVC
fittings (moulded as well as fabricated) like bends, tees, Y-
tees, crosses, boss connections, access pieces, saddle pieces,
cleanouts, adaptors for connections to other materials, plugs,
reducers, cowls, offset and other specials, jointing done with
solvent cement for fittings and specials, fixing at wall / ceiling
level supported by galvanized steel slotted rails, threaded
rods, clamps, hangers etc., making proper connection etc for
duct and ceiling suspended soil and waste lines. The
installation shall be complete in all respects including cutting
chases / holes in walls, slabs and making good the same as per
specifications. (All major MS / GI supports to hold the stack
is included in this item).
59 NS Providing, fixing, jointing, testing and commissioning UPVC
(Class III) Rain water downtake pipe conforming to IS:4985
cut to required lengths including all necessary fittings and
specials.UPVC fittings (moulded as well as fabricated) like
bends, tees, Y-tees, crosses, boss connections, access pieces,
saddle pieces, cleanouts, adaptors for connections to other
materials, plugs, reducers, cowls, offsets and other specials.
Fixing at wall/ceiling level supported by galvanized steel
slotted rails, threaded rods, clamps, hangers etc. Making
proper connection with cement solvent joint as per BIS /
manufacturer. Cutting, chases / holes in floors / walls / slab
and making good wherever required. (All major MS / GI
supports to hold the stack is included in this item).
NS 110 mm dia. 6 kg/cm2 (Class III ) RM 80.00 1015.00 81200.00
62 NS Providing, fixing, jointing and testing UPVC soil, waste, vent
pipework comprising UPVC pipe conforming to IS :4985-
1983 of class 3 ( 6kg/cm2) as specified below and fittings
(moulded as well as fabricated) like elbows, bends, reducers,
threaded tail pieces, caps, suitable elbow with suitable
extension piece for drain point and other specials jointing
with cement solvent, chasing, cutting and making good the
walls & floors pipes laid in floors shall be encased with 40
mm thick concrete all around, complete in all respects
including testing of complete installation for cocealed drain
lines. (All major MS / GI supports to hold is included in this
40 mm dia 6 kg/cm2 (Class III ) RM 10.00 324.00 3240.00
64 NS 50 mm dia 6 kg/cm2 (Class III ) RM 120.00 430.00 51600.00
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
65 Providing, fixing, jointing and testing UPVC soil, waste, vent
pipework comprising UPVC pipe conforming to IS :4985-
1983 of 10kg/cm2 as specified below and fittings (moulded
as well as fabricated) like elbows, bends, reducers, threaded
tail pieces, caps, suitable elbow with suitable extension piece
for drain point and other specials jointing with cement
solvent, chasing, cutting and making good the walls & floors
pipes laid in floors shall be encased with 40 mm thick
concrete all around, complete in all respects including testing
of complete installation for cocealed drain lines. (All major
MS / GI supports to hold is included in this item)
Providing and fixing UPVC/SWR trap (Multi trap) of self
cleaning design as per IS:13592 : 1992 complete including
cost of cutting and making good the cutouts in walls and
floors etc.including cutting and making good the walls and
floors wherever required complete.
67 NS 100 mm inlet and 75 mm outlet. Nos. 73.00 313.00 22849.00
68 Providing and fixing Heavy Class SS grating of approved
design including setting in floor with cement motor to match
with floor finish as per architect requirement suitable for
waster and FT, UT & FD.
69 NS Providing and fixing P.V.C. WC connector (straight or bend
type) with rubber lip ring. Including 110 mm dia PVC pipe /
bend of required length and proper connection with M seal
to C.I. pipe complete as required.
D. SUB HEAD - IV : EXTERNAL SEWAGE/ STORM
WATER DRAINAGE.
70 NS Providing, fixing, jointing, testing and commissioning UPVC
(Class III) Soil, Waste & Rain Water Drainage pipes
conforming to IS:4985 cut to required lengths including all
necessary fittings and specials. UPVC fittings (moulded as
well as fabricated) like bends, tees, Y-tees, access pieces,
saddle pieces, cleanouts, adaptors for connections to other
materials, reducers and other specials including trenching,
refilling & testing of joints etc. Making proper connection
with cement solvent joint as per BIS / manufacturer, complete
as per direction of Engineer in Charge.
110 mm diawork6 kg/cm2 (Class III ) RM 220.00 1106.00 243320.00
72 NS 200 mm dia 6 kg/cm2 (Class III ) RM 10.00 2629.00 26290.00
73 19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5
coarse sand : 10 graded stone aggregate 40 mm nominal size)
up to haunches of S.W. pipes including bed concrete as per
standard design :
Providing and fixing square-mouth S.W. gully trap class SP-1
complete with C.I. grating brick masonry chamber with water
75 19.4 tight C.I. cover with frame of 300 x300 mm size (inside) the
weight of cover to be not less than 4.50 kg and frame to be not
less than 2.70 kg as per standard design:
19.4.1 100x100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
76 19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1
cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4
coarse sand : 8 graded stone aggregate 40 mm nominal size,)
inside plastering 12 mm thick with cement mortar 1:3 ( 1
cement : 3 coarse sand) finished with floating coat of neat
cement and making channels in cement concrete 1:2:4 ( 1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size ) finished with a floating coat of neat cement
complete as per standard design:
19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover
with frame (light duty) 455x610 mm internal dimensions, total
weight of cover and frame to be not less than 38 kg (weight of
cover 23 kg and weight of frame 15 kg) :
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover
with frame ( medium duty ) 500 mm internal diameter, total
weight of cover and frame to be not less than 116 kg ( weight
of cover 58 kg and weight of frame 58 kg):
19.7.2.1 With common burnt clay F.P.S ( non modular) bricks of class Nos. 10.00 24324.94 243249.40
designation 7.5
78 19.8 Extra for depth for manholes :
19.8.1 Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Constructing brick masonry circular type manhole 0.91 m
internal dia at bottom and 0.56 m dia at to[ in cement mortar
1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm
thick with cement mortar 1:3 ( 1 cement: 3 coarse sand)
finished with a floating coat of neat cement, foundation
concrete 1:3:6 mix ( 1 cement: 3 coarse sand: 6 graded stone
aggregate 40 mm nominal size ), and making necessary
channel in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4
graded stone aggregate 20 mm nominal size) finished with a
floating coat of neat cement, all complete as per standard
80 19.9.1.1 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD- Each 2.00 11466.02 22932.04
20 grade designation) 560 mm internal diameter conforming
to IS: 12592, total weight of cover and frame to be not less
than 182 kg, fixed in cement concrete 1:2:4 (1 cement: 2
coarse sand: 4 graded stone aggregate 20 mm nominal size)
including centering, shuttering all complete. (Excavation, foot
rests and 12 mm thick cement plaster at the external surface
shall be paid for separately):
With cement burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Extra depth circular type manhole 0.91 m internal dia ( at
bottom) beyound 0.91 m to 1.67 m
81 19.10.1 With common burnt clay F.P.S. ( non modular) bricks of class Metre 2.00 6485.54 12971.08
designation 7.5
SUB HEAD - V : MISCELLANEOUS ITEMS
Providing and fixing M.S. puddle flanges (fabricated of 750
mm long pipe pieces) to R.C.C. water tanks wall / slab. The
entire fitting shall be hot dipped galvanized (Flanges shall
confirm to BS10 Table E) .
50 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x
100 mm plus dia of pipe).
65 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x
100 mm plus dia of pipe).
80 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x
100 mm plus dia of pipe).
100 mm dia (Flanged ends MS plate 6 mm thick; 250 mm x
20 mm plus dia of pipe).
Providing, testing & commissioning of dial type pressure
gauge with pressure scale of 0 to 15 kg / cm2. Provision of
isolation cock suitable for pressure of 15 kg / cum2 shall be
included in cost.
SUB HEAD - VI - WATER SUPPLY PUMPS
Providing, fixing, testing and commissioning of Horizontal
centrifugal pumps for pumping drinking water from sump to
overhead water tank, the pumps shall be made of CI casing,
CI Impeller, CS shaft & sleeve, Mechanical Seal connected to
a TEFC induction motor mounted on a common channel base
frame with coupling guard, motor to be suitable for 400/440
V, 3 Phase, 50 cycles AC power supply, including all
necessary accessories
Cold Water Pump: Domsetic set 1 58146.22 58146.22
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Capacity : 8.3 Litres / sec
Head : 20-36 Mtrs
Type of Pump : Horizonal Centrifugal pump
Total No. of Pump-2No.(1W+1S)
Providing, fixing, testing and commissioning of Horizontal
centrifugal pumps for pumping drinking water from sump to
overhead water tank, the pumps shall be made of CI casing,
88 NS CI Impeller, CS shaft & sleeve, Mechanical Seal connected to
a TEFC induction motor mounted on a common channel base
frame with coupling guard, motor to be suitable for 400/440
V, 3 Phase, 50 cycles AC power supply, including all
Cold Water accessories
Pump: Flushing set 1 34973.13 34973.13
Capacity : 3.5 Litres / sec
Head : 8-32 Mtrs
Type of Pump : Horizonal Centrifugal pump
Total No. of Pump-2No.(1W+1S)
Providing, fixing, testing and commissioning of Horizontal
centrifugal pumps for pumping drinking water from sump to
overhead water tank, the pumps shall be made of CI casing,
CI Impeller, CS shaft & sleeve, Mechanical Seal connected to
a TEFC induction motor mounted on a common channel base
frame with coupling guard, motor to be suitable for 400/440
V, 3 Phase, 50 cycles AC power supply, including all
89 NS necessary
Cold Water accessories
Pump: Well to Sump set 1 27213.07 27213.07
Capacity : 7.1 Litres / sec
Head : 8-14 Mtrs
Type of Pump : Horizonal Centrifugal pump
Total No. of Pump-2No.(1W+1S)
FIRE FIGHTING - VIRI BLOCK & ANNADHANAM
1 NS TERRACE PUMP (VIRI BLOCK)
NS Supply, erection, testing and commissioning of Electrical
driven Terrace pump with all necessary valves and fittings
comprising as follows: Electrical motor driven pump capable
of delivering 900LPM at a head of 25Mtrs 15HP mono block
to electrical motor fiited in a common base plate, coupling
and coupling guard complete.
MAKE : KIRLOSKAR
2 NS TERRACE PUMP (ANNADHANAM MANDPAM)
Supply, erection, testing and commissioning of Electrical
driven Terrace pump with all necessary valves and fittings
comprising as follows: Electrical motor driven pump capable
NS of delivering 900LPM at a head of 25Mtrs 10 HP mono block Nos. 1.00 55200.21 55200.21
to electrical motor fiited in a common base plate, coupling
and coupling guard complete.
MAKE : KIRLOSKAR
3 NS DOL PANEL (VIRI BLOCK)
NS Supply, installation, testing and commissioning of motor
control panel for the Terrace pump for fire fighting including
all neccesssary control wiring with indication lamps and
meters. Set 1.00
4 NS DOL PANEL (ANNADHANAM MANDPAM)
Supply, installation, testing and commissioning of motor
control panel for the Terrace pump for fire fighting including
all neccesssary control wiring with indication lamps and
5 NS POWER CABLE
NS Supply and Laying of below sized XLPE insulated PVC
sheathed Aluminium conductor armored cabling to the
incoming and outgoing of fire pump panel including necessary
termination, glanding, necessary connections etc
i) 3 c x 16 Sq.mm for VIRI BLOCK Mtr 36.00 200.00 7200.00
ii) 3 c x 16 Sq.mm for ANNADANAM MANDAPAM Mtr 42.00 200.00 8400.00
6 NS PRESSURE SWITCH
NS Supply, installation, testing and commissioning of pressure
Make: Danfoss/Indifss/Waree
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
ii) ANNADANAM MANDAPAM Nos. 1.00 1508.01 1508.01
7 NS PRESSURE GAUGE
NS Supply, installation, testing and commissioning of pressure
gauge with 0 to 12 kg range 4" dia.
ii) ANNADANAM MANDAPAM Nos. 1.00 1615.01 1615.01
Supply, erection, testing and commissioning of above ground
piping of approved make medium quality MS "C" class pipes
with branded malleable specials conforming to IS 1239 part 1
& 2 such as tees, elbows, unions, flanges, nipples etc.
including cutting, welding and painting the exposed pipes
with one coat of zinchromate primer and two coats of PO red
enamel paint. The pipes shall be supported suitably..Make:
a NS 100mm dia
ii) ANNADANAM MANDAPAM Mtrs 85.50 1499.00 128164.50
b NS 80mm dia
i) VIRI BLOCK Mtrs 6.00 1122.01 6732.06
ii) ANNADANAM MANDAPAM Mtrs 15.00 1122.01 16830.15
c NS 65mm dia
i) VIRI BLOCK Mtrs 45.00 1166.15 52476.75
ii) ANNADANAM MANDAPAM Mtrs 45.00 1166.15 52476.53
9 NS BUTTERFLY VALVE
NS Supply, installation, testing and commissioning of slim seal
type cast iron butterfly valves lever operated type with
necessary flanges, nuts, rubber gaskets and bolts complete
Make : Intervalve/Karthar/Advance
10 NS NON RETURN VALVE
NS Supply, installation, testing and commissioning of slim seal
type cast iron non-return valves with necessary
flanges,nuts,bolts and rubber gaskets complete.
ii) ANNADANAM MANDAPAM Nos. 1.00 10836.04 10836.04
Make : Intervalve/Karthar/Advance
11 NS HYDRANT VALVE
NS Supply, erection, testing and commissioning of single headed
Hydrant valve stainless steel with ISI mark as per the IS
specification fitted to 80mm dia pipe.
ii) ANNADANAM MANDAPAM Nos. 4.00 5987.02 23948.08
Make: Arihant/Newage/Essel
12 NS HOSE REEL SET
Supply, installation, testing and commissioning of First-aid
Hose Reel with MS construction spray painted in Post office
Red, conforming to IS 884 with up to date amendments,
complete with the following as required as per technical
specification(a) 30 m. long 20 mm (nominal internal dia water
hose Thermoplastic (Textile reinforced) Type-2 as per IS:
12585(b) 20 mm nominal internal ) dia gun metal globe valve
nozzle.(c) Drum and brackets for fixing the equipment's
on wall.(d) Connections from riser with 40 mm dia stop valve
(gun metal) M.S. Pipe
ii) ANNADANAM MANDAPAM Nos. 4.00 8413.03 33652.12
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Make: Arihant/Newage/Monsher
13 NS HOSE BOX
NS Supply, installation, testing and commissioning of hose boxes
wall/pedestal type of size 600 x 250 x 400 mm made out of 18
guge MS sheet steel with front side glass, locking
arrangement and painted with approved colour completed as
required and as per specifications.
ii) ANNADANAM MANDAPAM Nos. 4.00 3000.00 12000.00
14 NS FIRE HOSE
NS Supply, installation, testing and commissioning of 63 mm dia,
15 mtr. Long RRL hose pipe with 63 mm dia Male and
Female SS couplings duly binded with GI wire, rivets etc.
conforming to IS 636 (type-A) as required as per technical
ii) ANNADANAM MANDAPAM Nos. 4.00 4434.01 17736.04
Make: CRC/Newage
15 NS BRANCH PIPE
Supply, installation, testing and commissioning of 63 mm dia
Gun metal branch pipe with 20 mm (nominal internal
diameter) size SS nozzle conforming to IS 903, suitable for
instantaneous connection to interconnect hose pipe coupling
ii) ANNADANAM MANDAPAM Nos. 4.00 1648.01 6592.04
Make: Arihant/Newage/Swastik
16 NS FIRE BRIGADE INLET
NS Supply, installation, testing and commissioning of 3 way Fire
Brigade Inlet connection of 63 mm dia. built - in Gun metal
Non- return valves instantaneous coupling type arrangement
to be connected to wet riser main.
ii) ANNADANAM MANDAPAM Nos. 1.00 9302.04 9302.04
Make: Arihant/Newage/Swastik
17 NS BALL VALVE
NS Supply, installation, testing and commissioning of Ball valve
of following dia
i) VIRI BLOCK Nos. 6.00 800.00 4800.00
ii) ANNADANAM MANDAPAM Nos. 4.00 800.00 3200.00
Make: Zoloto/Sant/Keeto
18 NS AIR RELEASE VALVE
NS Supply, installation, testing and commissioning of gunmetal
air release valve 25 mm with necessary fittings etc. complete.
ii) ANNADANAM MANDAPAM Nos. 1.00 1800.00 1800.00
Make: Arihant/Karthar/Atom
19 NS ABC FIRE EXTINGUISHER
NS Supply and installation of ABC Stored pressure type Fire
Extinguisher 4 Kgs Capacity Mono Ammonium Phosphate
based Dry Chemical Powder as per IS 14609 with ISI Mark
for Fighting ABC Class of Fire, stored Pressure type of Mild
steel body pressurized by Nitrogen Gas. The Extinguisher
shall have pressure gaugefor indicating inside pressure with
opening and closing lever of squeeze grip type with tamper
proof seal, complete with wall bracket. The Extinguisher
should be manufactured strictly as per IS: 15683:2006 with
ii) ANNADANAM MANDAPAM Nos. 8.00 2000.00 16000.00
Make: Safex/Kanex/Bharat
20 NS CO2 FIRE EXTINGUISHER
NS Supply and installation of CO2 type fire extinguisher of 4.5
kg. Capacity complete with initial charges and installation
ii) ANNADANAM MANDAPAM Nos. 4.00 5800.00 23200.00
Make: Safex/Kanex/Bharat
FIRE ALARM SYSTEM
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
1 MANUAL CALL POINT
Supply, installation, testing and commissioning of manual call
points break glass type with hammer & chain
i) VIRI BLOCK Nos. 6.00 750.00 4500.00
ii) ANNADANAM MANDAPAM Nos. 4.00 750.00 3000.00
Supply, installation, testing and commissioning of audio alarm
i) VIRI BLOCK Nos. 6.00 800.00 4800.00
ii) ANNADANAM MANDAPAM Nos. 4.00 800.00 3200.00
3 FIRE ALARM PANEL
Supply, installation, testing and commissioning of Control
Panel of 4 Zone complete with charger, rectifier, alarm
display with all other necessary attachments
ii) ANNADANAM MANDAPAM Nos. 1.00 18500.00 18500.00
Make : Ravel/ Aswin/Agni
Supply ,Installation, testing and commissioning of 1 Sq.mm
i) VIRI BLOCK Meter 1080.00 40.00 43200.00
ii) ANNADANAM MANDAPAM Meter 700.00 40.00 28000.00
Make :Finolex /Havells/RR
Supply ,Installation, testing and commissioning of 20mm PVC
i) VIRI BLOCK Meter 400.00 55.00 22000.00
ii) ANNADANAM MANDAPAM Meter 300.00 55.00 16500.00
Supply Installation, testing and commissioning of 2 x 12V 7
Ah Battery for Panel
ii) ANNADANAM MANDAPAM Nos. 2.00 1100.00 2200.00
7 NS SIGN BOARDS
NS Supply & erection of Glow Sign Board made of 3mm thick
PVC foam board for each floor 12" x 4"
ii) ANNADANAM MANDAPAM Nos. 16.00 450.00 7200.00
b NS Supply & erection of Assembly Point sign board 16" x 16"
ii) ANNADANAM MANDAPAM Nos. 1.00 1800.00 1800.00
c NS Supply & erection of Fire roupe map drwing in A3 sheet with
plastic laminated
i) VIRI BLOCK Nos. 4.00 450.00 1800.00
ii) ANNADANAM MANDAPAM Nos. 4.00 450.00 1800.00
ELECTRICAL WORKS
1.0 SUB HEAD I - CT METERING PANELS
Technical Specification for CT METERING PANEL
Supply and erection of compartmentialised CT metering panel
(3 Compartment type) for
receiving the EB supply consisting of :-
300A 4 Pole copper bus bars suitable to accommodate 3 Nos.
CT's.The meter chamber will have provision to fix 3 phase 4
wire 50 HZ CT operated Kwhr meter to be supplied by supply
authorities and the front meter door shall be fitted with glass
/Acrylic cover infront of meter dial to read the meter
recording the meter door shall have provision for sealing
arrangement by supply authorities
The TTB chamber will have 3 phase 4 wire 50 HZ TTB.
All chambers should have sealing arrangement provision.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
3 Nos 315 Amps Porcelain cutouts and 500 Amps Neutral link
with cable chamber suitable for receiving 2 no. 3 1/2 core
240 sq mm PVC insulated Aluminium conductor armoured
The board should be manufactured such that should be
NS approved by Local supply authorities. Set 1
2.0 NS Technical Specification for MAIN PANEL
Suupply, erection, testing and commissioning of floor
mounting free standing dust &
vermin proof cubicle pattern switch board fabricated out of 14
sheets comprising of following for MAIN PANEL.
1 No.- 250A 4P 35KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
protection and with 230V shunt
trip releases Aux switch of 1 NO + 1 N/C for contacts
multiplication etc. as
1 - Digital type flush mounting power monitor
to indicate the following parameters and 5A CT
Current, Voltage, Frequency, KWh & KW,etc.
3 - Current transformer of ratio 315/5 class 1, 15VA
burden for metering.
1 Set. - 3 Nos. R, Y, B indicating lamp to indicate
supply position.
1 Set. - 2 Nos. Red & Green indicating lamp to
indicate ON-OFF
position of breaker.
3 Nos.- 250/5A Class P5 T5, 10 VA for power factor
1Set - Potential protection HRC fuses/MCB of suitable
indicating lamp, meter, control circuit etc.
GENERATOR INCOMER
1 No.- 250A 4P 35KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
protection and with 230V shunt
trip releases Aux switch of 1 NO + 1 N/C for contacts
multiplication etc. as
1 No. - Digital type flush mounting power monitor
with inbuilt selectors to indicate the following
Current, Voltage, KW,KWhr, Power factor,
Frequency, etc. CL -0.5
3 Nos. - 250/5A Class 1 15 VA C.T. metering
1 Set. - 3 Nos. R, Y, B indicating lamp to indicate
supply position.
1 Set. - 2 Nos. Red & Green indicating lamp to
indicate ON-OFF
position of breaker.
1 Set. - Amber Breaker trip due to fault indication
1 Set. - Potential fuses/MCB for voltmeter,
indicating lamps, meter, control circuit etc.
1 Set. - Outgoing terminals to receive Cables.
Both the incomers shall be mechanically interlocked to avoid
parlleing each other.
1 Set. 250A TP & N bus bars with Alu. flat with the size
having a current density of
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
0.7A / Sqmm. The Bus bar shall be provided with
colour coded heat shrunkable
PVC sleeves with the exception of joint. The bus bar
shall be supported at
suitable intervals with SMC/ FRP as per IS.
1 Nos. - 160A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
2 Nos. - 125A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
2 Nos. - 100A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
4 Nos. - 63A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
4 Nos. - 40A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
2 Nos. - 32A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
NS Total cost of Main Panel Set 1 440000.00 440000.00
Supply, erection, testing and commissioning of floor
mounting free standing dust & vermin proof cubicle pattern
DINING BLOCK PANEL fabricated out of 14 /16 SWG
CRCA sheets comprising of following.
1 No.- 125A TP & N 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
protection and with 230V shunt
trip releases Aux switch of 1 NO + 1 N/C for contacts
multiplication etc. as
1 No. - Digital type flush mounting power monitor
with RS 485 with inbuilt
selectors to indicate the following parameters
and 5A CT secondary.
Current, Voltage, Frequency, KWh &
3 Nos - Current transformer of ratio125/5 class 1,
15VA burden for metering.
2 Sets. - 3 Nos. R, Y, B indicating lamp to indicate
supply position.
2 Sets. - 2 Nos. Red & Green indicating lamp to
indicate ON-OFF position of breaker.
2 Sets - Potential protection HRC fuses/MCB of
suitable rating for
indicating lamp, meter, control circuit etc.
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
1 - 125A TP & N Alu. bus bar having a current
density of 0.7A per Sqmm
and with adequate number of FRP/SMC bus
supports at suitable interval
as per IS. The busbar shall be PVC sleeved with
heat shrukable colour
coded PVC sleeves with the exception of joint.
3 Nos. - 100A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
2 Nos. - 63A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
3 Nos. - 40A TPN 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
NS Total Cost for DINING BLOCK PANEL Set 1 165000.00 165000.00
4.0 NS Technical Specification for APFCR Panel -Qty - 1 No.
Supply, erection, testing & commissioning of floor/wall
mounting dust & vermin proof
cubicle pattern noncompartmentalised outdoor APFCR
Panel fabricated out of 14 /16 SWG CRCA
sheet comprising of the following :-
1 No.- 160A TP & N 25KA MCCB with manual closing
mechanism with Rotary
handle, fitted with over current and short circuit
protection and with 433V shunt
trip releases Aux switch of 1 NO + 1 N/C for contacts
multiplication etc. as
1 - 8 stage APFCR Relay.
1 - Auto manual selector switch.
1 - Digital type flush mounting meter with inbuilt
selector to indicate the
following parameters suitable for operation with
5A CT secondary.
Current, Voltage, Frequency
1 Set. - 3 Nos. R, Y, B indicating lamp to indicate
supply position.
1 Set. - 2 Nos. Red & Green indicating lamp to indicate
position of breaker.
1 Set. - Amber Breaker trip due to fault indication
1Set - Potential protection HRC fuses/MCB of suitable
indicating lamp, meter, control circuit etc.
1 - 160A TP & N Alu. bus bar having a current
density of 0.7A per Sqmm
and with adequate number of FRP/SMC bus
supports at suitable interval
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
as per IS. The busbar shall be PVC sleeved with
heat shrukable colour
coded PVC sleeves with the exception of joint.
1 No. - Capacitor compartment each with 63A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 15 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 15 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
2 Nos. - Capacitor compartment each with 63A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 10 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 10 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 5 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 5 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 4 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 4 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 3 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 3 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 2 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 2 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
1 No. - Capacitor compartment each with 32A TP 10KA
FD kit, an auxilary switch 1 NO + 1 NC, and
suitably rated and
having specific duty contactor with necessary bi-
metal relays etc. all
complete for control of 1 KVAr capacitors. ON -
OFF push buttons,
ON -OFF indicating lamp, provided with a 1 KVar
capacitor bank with
reactors, control wiring from the APFC relay all
complete for proper
operation of bringing in or out of the capacitors
connected to maintain the
Power Factor as stipulated by the supply authorities.
As per details given.
1 - 160A TP & N Alu. bus bar having a current
density of 0.7A per Sqmm
and with adequate number of FRP/SMC bus
supports at suitable interval
as per IS. The busbar shall be PVC sleeved with
heat shrukable colour
coded PVC sleeves with the exception of joint.
The instrument chamber meter /instruments shall be wired
with 2.5 Sqmm for CT's &
1.5 Sqmm for other circuits multi-strand copper conductor
wire with double sleeving &
with appropriate colour code and the terminal ferruled and
connected with suitable lugs.
The above panel shall be fabricated as per IS and complete
with specified bus
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
bar, bus supports, interconnections from bus to MCCB,
MCCB to capacitor banks
duly taped or sleeved wirings providing 2 Nos.earth bus with
flat, door earthing with braided copper etc. all complte as per
IS as acceptable
to Architects in conformity with the Local Electrical
Inspectorate whether or
not all items has brought in this. The board shall be provided
with noncompartmental
and intercompartment shrouds, terminal extensions for
receiving cable, shrouds
for terminals etc. The aggregated capacity of each of the
bank shall be of 50
KVAr. The board shall be finished with powder coated paint
of approved shade
after duly treated for rust prevention and appllying 2 coats of
metal primer. The
board shall be provided with necessary warning, feeder
designation labels as per
IS and as per site requirement and cater to General
requirement of switch board
specification given in the tender.
NS Total Cost of APFCR Panel Set 1 145000.00 145000.00
SUB HEAD I - DISTRIBUTION BOARDS
Supplying and fixing following way, horizontal type three
pole and neutral, sheet steel, MCB distribution board, 415 V,
5 on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder
painted including earthing etc. as required. (But without
NS 4MCB/RCCB/Isolator)
way (4 + 12), Double door Nos 3 2902.00 8706.00
7 NS 8 way (4 + 24), Double door Nos 2 4187.00 8374.00
Supplying and fixing of following ways surface/ recess
mounting, vertical type, 415 V, TPN MCB distribution board
of sheet steel, dust protected, duly powder painted, inclusive
8 of 100 A tinned copper bus bar, common neutral link, earth
bar, din bar for mounting MCBs (but without MCBs and
incomer ) as required . (Note : Vertical type MCB TPDB is
normally used where 3 phase outlets are required.)
Supplying and fixing following rating, TPN, 415 V, MCCB
10 NS 10KA " C " Curvein the existing MCB DB complete with
connections, testing and commissioning etc. as required
Supplying and fixing following rating, Three pole, 415 V,
MCB 10KA " C " Curve in the existing MCB DB complete
with connections, testing and commissioning etc. as required
Supplying and fixing following rating, Four pole, 415 V,
MCB 10KA " C " Curvein the existing MCB DB complete
with connections, testing and commissioning etc. as required
Supplying and fixing following rating, double pole, (single
phase and neutral), 240 V, residual current circuit breaker
(RCCB), having a sensitivity current 30 mA in the existing
complete with connections, testing and commissioning etc. as
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA,
"C" curve, miniature circuit breaker suitable for inductive
load of following poles in the existing MCB DB complete
with connections, testing and commissioning etc. as required.
SUB TOTAL I - DISTRIBUTION BOARDS
SUB HEAD II - LT CABLING AND TERMINATON
90.12.1.29 Supply & laying of one number PVC insulated and PVC
sheathed armoured aluminium power cable of 1.1KV grade of
the following sizes in ground including excavation of trench
17 of size 35 x 75 cm, refilling the trench etc. as required but
excluding sand cushioning and protective covering (in
ordinary soil).
Supply & laying of one number PVC insulated and PVC
sheathed armoured aluminium power cable of 1.1KV grade of
18 the following sizes in ground including excavation of trench
of size 35 x 75 cm, refilling the trench etc. as required but
excluding sand cushioning and protective covering (in
4x 16sq.mm Al weatherproof cable with 8swg GI powder
NS coated wire for KSEB service connection
Supplying and making indoor cable end termination with
Brass compression gland and aluminium lugs for the
following sizes of PVC insulated and PVC sheathed
aluminium / copper conductor cable of 1.1 KV Grade as
Supplying of the following size of PVC insulated and PVC
sheathed XLPE Unarmoured Flexible copper cables
IS:1554/Part-I/1988 etc as required.
26 NS 4C X 4sq.mm Copper cable RM 164 215.00 35260.00
Supplying and making indoor cable end termination with
Brass compression gland and aluminium lugs for the
following sizes of PVC insulated and PVC sheathed
aluminium / copper conductor cable of 1.1 KV Grade as
27 NS 4C X 4sq.mm Copper.Cable Each 10 577.00 5770.00
SUB TOTAL II - LT CABLING AND TERMINATON
SUB HEAD III CABLE TRAY
Supplying and installing following size of perforated Hot
Dipped Galvanised Iron cable trays with perforation not more
than 17.5%, in convenient sections, joined with connectors,
28 suspended from the ceiling with G.I. suspenders including
mm depth X 1.6 mm thickness RM 37 665.00 24605.00
29 NS 300 mm width X 50 mm depth X 1.6 mm thickness RM 93 928.00 86304.00
Supplying and installing following size of perforated Hot
Dipped Galvanised Iron cable tray bends with perforation not
more than 17.5%,, joined with connectors, suspended from the
ceiling with G.I. suspenders including bolts & nuts, etc as
30 NS required.
150 mm width X 50 mm depth X 1.6 mm thickness Each 2 1289.00 2578.00
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
31 NS 300 mm width X 50 mm depth X 1.6 mm thickness Each 12 1911.00 22932.00
32 NS Supplying and fixing cable identification tags made out of
round aluminium plates of thickness not less than 3mm and
tying with cable with appropriate intravels for cable
emenating from individual SSB.
SUB HEAD IV - EARTHING
33 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm
thick including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering 10 10944.80 109448.00
pipe of 2.7 metre long etc.with charcoal/coke and salt as
34 5.15 Providing and fixing 25mm x 5mm G.I. strip on surface or in
recess for connections etc. as required. RM
35 NS Providing and fixing 8SWG copper wire on surface or in
recess for connections etc. as required. RM
SUB HEAD V - WIRING
36 1.10 Wiring for light point / fan point / exhaust fan point / call
bell point with 1.5 sq.mm. FRLS PVC insulated copper
conductor single core cable in surface / recessed medium
class pvc conduit, with modular switch, modular plate,suitable
G.I.Box and earthing the point with 1.5 sq mm PVC insulated
FRLS copper conductor single core cable etc as required.
37 1.55 Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point (without independent
switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable in surface/ recessed PVC conduit,
and earthing the point with 1.5 sq. mm FRLS PVC insulated
copper conductor single core cable etc. as required.
38 1.11 Wiring for twin control light point with 1.5 sq.mm FR PVC
insulated copper conductor single core cable in surface /
recessed medium class pvc conduit, two way modular switch,
modular plate ,suitable GI box, and earthing the point with
1.5sqmm FR PVC insulated copper conductor single core
cable etc as required.
39 1.14 Wiring for circuit / sub main wiring along with earth wire
with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/recessed medium class
PVC conduit as required. (for Lighting Ckt)
d 1.14.8 4 x 4 sq.mm + 2 x 4 sq.mm earth wire RM 75 371.03 27827.25
40 1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
recessed medium class PVC conduit along with 1 No. 4 sq. RM 911.2 221.83 202131.50
mm FRLS PVC insulated copper conductor single core cable
for loop earthing as required.
41 1.32 Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess,including providing
and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and Each 23 536.08 12329.84
15/16 amps modular type switch, connections, painting etc as
42 1.31 Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess,including and
providing and fixing 1 No 3 pin 5/6 amps modular socket Each 36 413.29 14878.44
outlet and 1 No 5/6 amps modular type switch, connections,
earthig,painting etc as required. (for lighting plugs to be used
43 1.25 in non residential
Supplying buildings)
and fixing two module stepped type electronic fan
regulator on the existing modular plate switch box
including connections but excluding modular plate etc. as
SUB HEAD VI - LIGHT FITTINGS
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
44 NS Supply, Installation, testing and commissioning of 40W LED
Tube Light fitting Surface /suspended/recess mounted with all
other accessoriess i/c connections with 1.5 sq.mm PVC Nos 56 3289.00 184184.00
insulated FR copper conductor single core cable etc as
45 NS Supply, Installation, testing and commissioning of 40W LED
IP65 Tube Light fitting Surface /suspended/recess mounted
with all other accessoriess i/c connections with 1.5 sq.mm Nos 12 2960.00 35520.00
PVC insulated FR copper conductor single core cable etc as
46 NS Supply, Installation, testing and commissioning of 18W LED
Tube Light fitting Surface/suspended/recess mounted with all
other accessoriess i/c connections with 1.5 sq.mm PVC Nos 202 1771.00 357742.00
insulated FR copper conductor single core cable etc as
47 NS Supply, Installation, testing and commissioning of 30W LED
Down Light fitting surface mounted with all other
accessoriess i/c connections with 1.5 sq.mm PVC insulated
FR copper conductor single core cable etc as required.
48 NS Supply, Installation, testing and commissioning of 18W LED
Wall Light fitting with all other accessoriess i/c connections
with 1.5 sq.mm PVC insulated FR copper conductor single
core cable etc as required.
49 NS Supply, Installation, testing and commissioning of 11W LED
Mirror Light wall mount fitting with all other accessoriess i/c
connections with 1.5 sq.mm PVC insulated FR copper
conductor single core cable etc as required.
50 NS Supply, Installation, testing and commissioning of 6W LED
STEP Light fitting with all other accessoriess i/c connections
with 1.5 sq.mm PVC insulated FR copper conductor single
core cable etc as required.
51 NS Supply, Installation, testing and commissioning of 3600mm
(12 Ft.) sweep HVLS fan with steel rope/ down rod, fan
shackle, bolt and nut, etc operation on 430 volts,three Nos 5 350000.00 1750000.00
phase,50HZ,AC supply,including wiring etc as reqd.
52 NS Supply, Installation, testing and commissioning of 1200mm
sweep ceiling fan with double bearing, i/c 3 nos blade,
condensor, down rod, fan shackle, bolt and nut, cottor pin etc
operation on 240 volts,single phase,50HZ,AC supply, of
360/390RPM,including wiring the down rod of standard Nos 103 2537.00 261311.00
length( upto 75cm) with 1.5sq.mm FR PVC insulated, copper
conductor single core cable etc as reqd.(but without regulator.
53 NS Supply,installation,testing and commissioning of 305 mm
exhaust fan, metal body, i/c making the hole to suit the size of
the above fan, making good the damages connections etc as Nos 14 2171.00 30394.00
54 90.3.20.3 Supply & installation of light fittings on TW round block
<br> Supply, conveyance installation testing and
commissioning the light fittings of following types made of
CRCA with 0.5mm thickness complete with all accessories
and lamps etc. directly on wall or ceiling with PVC round
block neatly painted to suit the fitting and giving connection Each 203 1207.15 245051.45
with required length of 16/0.20mm 3 core copper conductor
flex wire conforming to relevant ISS and giving connections
1200 mm 1X20W LED Lamp with box type fixture
55 NS Supply and erection of 10W bulkhead type LED fixtures
Philips WT202W or equivalent
56 NS Supply and erection of 450mm heavy duty exhaust fan ( for
SUB HEAD VII -LIFT & LIFT ALLIED WORKS
58 NS Wiring with 3 x 2.5 Sqmm PVC copper wire in 20mm MS
electrical grade conduit withall standard accessories for lift
shaft lights & 6/16A 3pin sockets in the lift shaft as surface
conduit wiring for lift well lighting. (Lift shaft lighting and
socket to be controlled by SP MCB in the lift room lighting
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
Supply and fixing of 2 Nos. 6A 1 Way switch 1 No. 6/16A
3pin socket MODULAR type to an 16g MS enclosure with Nos 4 1567.00 6268.00
3mm thick hylam sheet top. (Note: The MS box shall have
arrangement to terminate earth wire.
Supply & fixing Bulk head fittings with metal guard complete
with holder etc. suitable to house 10W LED at lift shafts Nos 4 1689.00 6756.00
SUB TOTAL VII -LIFT & LIFT ALLIED WORKS
61 SUB HEAD VIII - MISCELLANEOUS
NS Providing and fixing the following electrical accessories
confirming to relevant IS specification
b NS LT Mat of size (6mm thick of size 2M X 1 M) Nos. 5 8897.00 44485.00
c NS Fire Extinguishers, Dry Chemical type 5Kg Nos. 2 5367.00 10734.00
d NS 3 nos Fire Buckets with stand and sand filled Set 1 2648.00 2648.00
e NS First Aid box Nos. 1 2006.00 2006.00
f NS First aid chart(in Malayalam,Hindi & English) Nos. 1 1416.00 1416.00
h NS Portable rechargeable emergency led light Nos. 1 5389.00 5389.00
i NS Earth discharge rod Nos. 1 9440.00 9440.00
SUB HEAD IX -ELV WORKS
62 NS Supplying and Fixing of modular RJ-11 telephone jack single
with shutter with suitable box, plate, i/c connections etc as Each
63 NS Supplying and Fixing of modular RJ-45 computer jack with
shutter with suitable GI box, Modular plate, i/c connections 2 876.00 1752.00
etc as required. Each
64 1.18 Supplying and drawing following pair 0.5 mm dia FRLS
PVC insulated annealed copper conductor, unarmored
telephone cable in the existing surface/ recessed steel/
a 1.18.2 2required.
65 1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in
66 1.21 Supplying and fixing following sizes of PVC conduit along
with the accessories in surface / recess including cutting the
wall and making good the same in case of recessed conduit as
required. (For Tel & Data)
67 NS Design, manufacture, transportation, installation testing and
capacity run on 1500 RPM, four stroke, designed for
operating on HSD,
completed with 180 KVA Alternator 415V, 50 hZ, 0.8 PF,
370 litres, batteries 12V suitable for starting of the DG set.anti
pads, silencers with thermal insulation, with Electonic
Engine control panel suitable for Syncronous operation and
system in suitable size accoustic enclosure as per
requirements of PCB &
authorites includes the following transport, insurance,
inclusing performance tests and excluding civil foundations
civil,structural and
electrical works, control and instrumentation etc.The rate
shall include the
fuel pipelines including valuves from tank to engines.The
shell have proper air intake and exhaust system as per OEM Nos. 1 592000.00 592000.00
Ref no. ITEM UNIT QUANTITY RATE AMOUNT
68 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm
thick including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering 4 10945.00 43780.00
pipe of 2.7 metre long etc.with charcoal/coke and salt as
69 NS Providing and fixing 8SWG copper wire on surface or in
recess for connections etc. as required. RM
70 NS Providing and fixing 40mm x 6mm GI strip on surface/recess
from earth electrode as required RM
71 NS Providing and fixing 25mm x 6mm Copper strip on
surface/recess from earth electrode as required RM
72 Supply and laying of necessary control cabling from generator
engine panel to generator control panel with suitable gland,
crimping sockets and earthing etc., in prepared trench / cable
tray for DG sets.
a NS 16C x 2.5 Sqmm armoured copper cable. RM 21 469.00 9849.00
b NS 4C x 4 Sqmm armoured copper cable. RM 21 215.00 4515.00
c NS 4C x 2.5 Sqmm armoured copper cable. RM 21 152.00 3192.00
73 NS Supplying and fixing of MS Self Supporting structure made of
MS Channels and MS angles on existing CC foundation for
supporting the exhaust piping of the DG Set including 500 140.00 70000.00
painting with zinc chromite primer and aluminium/ synthetic
enamel paint etc as required. Kg
74 90.4.5.2 Supply, conveyance, installation, testing ad commissioning of
ceiling fan of the following sizes using standard accessories
excluding resistance type regulator, wiring the down dod with
16/0.20mm PVC insulated and PVC sheathed 650/1100V
grade 3 core round copper conductor flex wire or with 108 1858.15 200680.20
extended original wiring etc as required. 1200mm - 5 star
rated ceiling fan complete with 300mm down rod canopies,
shackeles and bldes and resistance type regulator working on
230V/240V Single phase AC Each
ANNADHANAM BLOCK SUB TOTAL - (C ) 46284144.29
GRAND TOTAL (A+B+C) ₹ 167,007,643.60
GRAND TOTAL (A+B+C) ₹ 167,007,643.60
Rupees Sixteen Crore Seventy Lakh Seven Thousand Six
Hundred and Forty Three and Sixty Paise
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
NIT_Package II.pdf
Tender Document
GCC 2019 including 16 Amendments.pdf
Tender Document
Technical specification NS Items.pdf
Tender Document
Tender Drawing Maniyancode Part 1.pdf
Tender Document
Tender Drawing Maniyancode Part 2.pdf
Tender Document
Tender Drawing Sukhapuram Part 1.pdf
Tender Document
Tender Drawing Sukhapuram Part 2.pdf
Tender Document
Tender Drawing Sukhapuram Part 3.pdf
Tender Document
TENDER BOQ.pdf
Tender Document
corrigendum-706-Corrigendum 01.pdf
pdf • 4.99 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .