| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC AIR FORCE ROAD GORAIMARI HALESHWAR TEZPUR SONITPUR ASSAM 784104 | SONITPUR | ASSAM | 784104 | ₹40.3 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹45.1 L+₹4.8 L (12.0%)Rejected-Finance | ₹45.1 L+₹4.8 L (12.0%) | L2 | Rejected-Finance NOT L1 |
| 3 | L3₹45.2 L+₹4.9 L (12.2%)Rejected-Finance VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | ₹45.2 L+₹4.9 L (12.2%) | L3 | Rejected-Finance NOT L1 |
| 4 | L4₹45.2 L+₹4.9 L (12.2%)Rejected-Finance | ₹45.2 L+₹4.9 L (12.2%) | L4 | Rejected-Finance NOT L1 |
| 5 | L5₹45.2 L+₹4.9 L (12.2%)Rejected-Finance AIR FORCE ROAD GORAIMARI PO HALESWAR PS TEZPUR DISTT SONITPUR ASSAM 784104 | SONITPUR | ASSAM | 784104 | ₹45.2 L+₹4.9 L (12.2%) | L5 | Rejected-Finance NOT L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Mar 2023, 6:00 pmClosed
GE AF TEZPUR
GE AF TEZPUR,PO-SALONIBARI,DIST-SONITPUR,ASSAM
CERTAIN REPAIR/MAINTENANCE OF CEILING FANS,GEYSERS,EXHAUST FANS AND OTHER INTERNAL E/M WORKS AT AFS TEZPUR UNDER GE (AF) TEZPUR.
2023_MES_579162_2
GE AF/ TEZ/8807/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
TEZPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) TEZPUR
₹80,000
Yes
18 May 2023
24 Feb 2023
8 Mar 2023
24 Feb 2023
6 Mar 2023
1 Mar 2023
Amount
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one bell/buzzer point controlled by one push button including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light point controlled by two 2-way switchs including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 5 Amps socket outlet independent including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
All as per Serial Item No.4 Here in Before but for,one 3 Pin 5 Amps socket outlet on same board with other switch,complete all as specified and directed.
Materials and Labour for point wiring with 2.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket outlet independent including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade,single core,laid into and including stove enamelled steel conduit complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid into and including stove enamelled steel conduit complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 5 Amps socket outlet independent including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
All as per Serial Item No.8 Here in Before but for,one 3 Pin 5 Amps socket outlet on same board with other switch,complete all as specified and directed.
Materials and Labour for point wiring with 2.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid into and including stove enamelled steel conduit complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket outlet independent including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade,single core,laid into the existing concealed PVC conduit/stove enamelled steel conduit fixed to walls/ceiling including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid into the existing concealed PVC conduit/stove enamelled steel conduit fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light point controlled by two 2-way switchs including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid into the existing concealed PVC conduit/stove enamelled steel conduit fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 5 Amps socket outlet independent including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power),complete including fittings such as switches,ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls,floors etc.,complete all as specified and directed.
All as per Serial Item No.13 Here in Before but for,one 3 Pin 5 Amps socket outlet on same board with other switch,complete all as specified and directed.
Materials and Labour for point wiring with 2.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid into the existing concealed PVC conduit/stove enamelled steel conduit fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket outlet independent including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Supply and fix switch piano, flush button, single pole, one way, 6 Amps, complete all as specified and directed.
Supply and fix in repair,switch piano, flush button, single pole, one way, 6 Amps, complete all as specified and directed.
Supply and fix switch piano, flush button, single pole, two way, 6 Amps, complete all as specified and directed.
Supply and fix in repair,switch piano, flush button, single pole, two way, 6 Amps, complete all as specified and directed.
Supply and fix, bell push, flush type,5 Amps, complete all as specified and directed.
Supply and fix in repair,bell push, flush type,5 Amps, complete all as specified and directed.
Supply and Fix in repair,Modular Switch, one way,6 Amps,1 Module, complete all as specified and directed.
Supply and Fix in repair,Modular Switch, 2 way,6 Amps,1 Module, complete all as specified and directed.
Supply and Fix in repair,Modular Switch,one way,16 Amps,1 Module, complete all as specified and directed.
Supply and Fix,ceiling rose,three terminal, PVC/polycarbonate insulated body, complete all as specified and directed.
Supply and Fix in repair,ceiling rose,three terminal, PVC/polycarbonate insulated body, complete all as specified and directed.
Supply and fix socket outlet 3 pin, 6A, flush type, complete all as specified and directed.
Supply and Fix,switch socket combination 2 in 1, 6A flush type,complete all as specified and directed.
Supply and Fix in repair,switch socket combination 2 in 1, 6A flush type, complete all as specified and directed.
Supply and Fix,switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal,complete all as specified and directed.
Supply and Fix in repair,switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal,complete all as specified and directed.
Supply and Fix in repair,Modular Socket, 6 Amps, 2/3 Pin, 2 Module, complete all as specified and directed.
Supply and Fix in repair,Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed.
Supply and Fix stepped type electronic fan regulator, flush type, on existing phenolic laminated sheet etc. as required,complete all as specified and directed.
Supply and Fix in repair,stepped type electronic fan regulator, flush type, on existing phenolic laminated sheet etc. as required,complete all as specified and directed.
Supply and Fix in repair,Modular Fan step regulator, 120W - 2 module,complete all as specified and directed.
Supply and Fix,Lamp holder, PVC/Polycarbonate type, with back plate suitable for batten fittings complete all as specified and directed.
Supply and Fix in repair,Lamp holder, PVC/Polycarbonate type, with back plate suitable for batten fittings complete all as specified and directed.
Supply and Fix,bell multi music type,complete all as specified and directed.
Supply and Fix in repair,bell multi music type,complete all as specified and directed.
Supply and Fix, LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed.
Supply and Fix in repair, LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed.
Supply and Fix,LED lights fitting 1x 20W, 220V,AC decorative box type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose,complete all as specified and directed. [Cat No. CCS-100-20-65-HL2-DP-NWH of Make 'Crompton Greaves' or equivalent Model of Make 'Wipro'/'Philips'/'GE']
Supply and Fix in repairs,LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose,complete all as specified and directed. [Cat No. CCS-100-20-65-HL2-DP-NWH of Make 'Crompton Greaves' or equivalent Model of Make 'Wipro'/'Philips'/'GE']
Supply and Fix in repair,LED batten with poly carbonate housing and polycarbonate diffuser, with white LEDs,1X22 W,lumen efficacy more than 100lm/W, with electronic driver complete with all accessories internally pre wired,including lamp,complete all as specified and directed. [Cat No.LHEXBLP7PN1W022 of Make “Havells” or equivalent Model of Make Wipro'/'Philips'/'GE'/ Crompton Greaves’]
Supply and Fix in repair,1X20 W, LED smart batten (Tuneable White) with colour options and provisions to alter the brightness and with electronic control driver complete with all accessories internally pre wired,including lamp,complete all as specified and directed. [Cat No.LHLDAMNDUA8R020 of Make “Havells” or equivalent Model of Make Wipro'/'Philips'/'GE'/ Crompton Greaves’]
Supply and Fix,decorative wall light fixture made up of polycarbonate, with and including 15 W retrofit LED Lamp (Spiral B-22 base) complete all as specified and directed. [Model CITY 2, Cat No.LHDL03160099 for light fitting and Cat No. LHLDDEEEML8R015 for Lamp, of Make 'Havells' or equivalent Model of Make 'Philips'/ 'Wipro']
Supply and Fix in repairs, decorative wall light fixture made up of polycarbonate, with and including 15 W retrofit LED Lamp (Spiral B-22 base) complete all as specified and directed. [Model CITY 2, Cat No.LHDL03160099 for light fitting and Cat No. LHLDDEEEML8R015 for Lamp, of Make 'Havells' or equivalent Model of Make 'Philips'/ 'Wipro']
Supply and Fix in repair,round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed. [Cat No.LCDEP-06-CDL of Make 'Crompton Greaves' or equivalent Model of Make 'Wipro'/'Philips'/'GE']
Supply and Fix in repair,round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed. [Cat No.LCDEP-12-CDL of Make 'Crompton Greaves' or equivalent Model of Make 'Wipro'/'Philips'/'GE']
Supply and Fix in repairs,36 Watts,LED recessed full lit luminaire,size 600 mm x 600 mm with glare free uniform illumination,lumen efficacy >100 Lumen/Watt, complete all as specified and directed. [Cat No.LCTLSNE-36-FO-CDL of Make 'Crompton Greaves' or equivalent Model of Make 'Wipro'/'Philips'/'GE']
Supply and Fix in repairs, LED post top light fittings, 40 Watts,CCT 5700°K, Power Factor >95%, AC input voltage 120V-277V,surge protection 5 KV, with aluminium alloy power coated housing and aluminium bright anodised housing, opal polycarbonate diffuser and degree of protection IP-65, complete all as specified and directed. [Cat No.LPTO-40-CDL of Make 'Crompton Greaves' or equivalent Model of Make 'Wipro'/'Philips'/'GE']
Refixing of serviceable light fittings obtained at site and connecting up,complete all as specified and directed. Note:- Serviceable light fittings obtained at site during taking down existing unserviceable point wirings shall be re-fixed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn into existing surface/recessed steel/PVC conduit and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring, including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity),complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn into existing surface/recessed steel/PVC conduit and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring, including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity),complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn into and including stove enamelled steel conduit and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn into and including stove enamelled steel conduit and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Dressing/aligning of existing circuit/sub main wiring by taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including steel conduit with fittings etc.,making good disturbed surfaces of walls, floors etc.and refixing the same in original position,complete all as specified and directed. Note:- Damaged steel conduit/PVC Casing Capping for replacement if any will be measured and paid seperately under respective item of this BOQ.
Supply Only,25 mm size PVC Casing Capping,ISI Marked(IS:14927),all as specified.
Supply Only,20 mm external diameter,stove enamelled black,rigid steel conduit,welded,all as specified.
Supply and Fix in repairs,3 mm thick plastic laminated sheet cover (ISI Marked) of size 125 mm x 175 mm,for mounting switches/ regulator /bell push etc,complete all as specified and directed.
Supply and Fix in repairs,3 mm thick plastic laminated sheet cover (ISI Marked) of size 175 mm x 225 mm,for mounting switches/ regulator /bell push etc,complete all as specified and directed.
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 4 way, with 200 Amps rated bus bar, Single Pole & Neutral,complete all as specified and directed. [Cat No. 5076 10 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 200 Amps rated bus bar, Single Pole & Neutral,complete all as specified and directed. [Cat No. 5076 11 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs,415 Volts, 4 Way,Triple Pole & Neutral,complete all as specified and directed. [Cat No. 5076 70 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
Supply and Fix, miniature circuit breaker (MCBs) single pole, 240 Volts,10KA,C curve, 6 to 32 Amps complete all as specified and directed. [Cat No. 4085 87-4085 95 of Make Legrand or equivalent Model of Make L&T/Hager/Seimens/GE/Schneider/ABB]
Supply and Fix in repair, miniature circuit breaker (MCBs) single pole, 240 Volts,10KA,C curve, 6 to 32 Amps complete all as specified and directed. [Cat No. 4085 87-4085 95 of Make Legrand or equivalent Model of Make L&T/Hager/Seimens/GE/Schneider/ABB]
Supply and Fix, miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA, 6 to 32 Amps complete all as specified and directed. [Cat No. 4086 09-4086 17 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and Fix in repair, miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA, 6 to 32 Amps complete all as specified and directed. [Cat No. 4086 09-4086 17 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and Fix,miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA, 40 Amps complete all as specified and directed. [Cat No. 4086 18 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and Fix in repairs,miniature circuit breaker (MCBs) single pole and neutral, 240 Volts,10KA, 40 Amps complete all as specified and directed. [Cat No. 4086 18 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and Fix,miniature circuit breaker (MCBs) triple pole, & neutral, 415 Volts, 10KA, 63 Amps complete all as specified and directed. [Cat No. 4086 83 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix in repair,miniature circuit breaker (MCBs) triple pole, & neutral, 415 Volts, 10KA, 63 Amps complete all as specified and directed. [Cat No. 4086 83 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and fix PVC blanking plates,single way suitable for blank ways of MCB DBs, complete all as specified and directed.
Supply and fix in repair,electronic meters temper proof LCD display with polycarbonate cover single phase 230 V,5-30 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH,complete all as specified and directed. [Cat No.WM101BC5DL0BOX of Make L&T/'Liberty 200' of Make Secure Meters or equivalent models of the Makes mentioned in the particular specifications.] Note:- The existing energy meter(s) shall be deposited by the Contractor in the store yard of AGE E/M (AF) Tezpur and receipt voucher obtained.
Supply and Fix in repair,meter box/DB box made of 1.00 mm thick MS Sheet 600mm X 900mm X 250mm with double leaf door and suitable locking arrangement,duly painted both externally and internally,complete all as speciied and directed.
Taking down carefully existing ceiling fan 1200 mm/1400 mm sweep, dismantaling parts,cleaning throughly internally and externally, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling,hanging in original position and connecting up including provision of cable from ceiling rose or connector to fan and including testing and commissioning,complete all as specified and directed.
Taking down carefully existing exhaust fan 300 mm/450 mm sweep,dismantaling parts,cleaning throughly internally and externally, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling,fixing in original position and connecting up including provision of cable from ceiling rose or connector to fan and including testing and commissioning,complete all as specified and directed.
Disconnecting power supply from existing wall mounted/table fan any size/sweep,taking down carefully,dismantaling parts,cleaning throughly internally and externally, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations,replacement of defective parts,re-assembling,fixing in original position and connecting including testing and commissioning,complete all as specified and directed.
Disconnecting power supply from existing pedestal fan of any size/sweep, dismantaling parts,cleaning throughly internally and externally, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling,placing in original position and connecting up including testing and commissioning,complete all as specified and directed.complete all as specified and directed. NOTES:- (Applicable for BOQ Serial Item No.79,80,81&82) (i) Repair woks shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Spares for replacement will be measured and paid separately.
Taking down carefully existing ceiling fan 1200 mm/1400 mm sweep, dismantaling of parts,removing burnt out windings with insulating materials,cleaning throughly internally and externally,rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing,lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioningcomplete all as specified and as directed.
Taking down carefully exhaust fan 300 mm/450 mm size, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally,rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning,complete all as specified and directed.
Disconnecting power supply,taking down carefully existing wall mounted fan any size/sweep,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally,rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning,complete all as specified and directed.
Disconnecting power supply from existing pedestal fan of any size/sweep, dismantaling of parts,removing burnt out windings with insulating materials, cleaning throughly internally and externally,rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations,replacement of defective parts,re-assembling, placing in original position including testing and commissioning,complete all as specified and directed. NOTES:- (Applicable for BOQ Serial Item No. 83,84,85&85) (i) Repairs and rewinding woks shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Spares for replacement will be measured and paid separately.
Materials and Labour for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust etc. including writing MES No.,complete all as specified and as directed.
Materials and Labour for painting of exhaust fans 300mm/400mm/450mm size complete with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust etc. including writing MES No.,complete all as specified and as directed.
Materials and Labour for painting of pedestal fans of any size/sweep complete with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust etc. including writing MES No.,complete all as specified and as directed.
Supply Only,Gun Metal Bushing/Sleeve Bearing of suitable for shaft size.
Supply Only,Capacitors for electric fan motors, 2.5 mfd, 440 V conforming to IS:1709 (Cat No. QHPCWC5002X5 of Make Havells or equivalent Model of Make UNIVERSAL/EPCOS)
Supply Only,Capacitors for electric fan motors,4 mfd, 440 V conforming to IS: 1709 (Cat No. QHPCWC5003X1 of Make Havells or equivalent Model of Make UNIVERSAL/EPCOS)
Supply Only,Chrome Steel Ball Bearing,size 6201 for fan as per OEMs specifications. (Make: TATA/NBC/SKF)
Supply only, chrome steel ball bearings, size 6003 for fan as per OEMs specifications. (Make: TATA/NBC/SKF)
Supply Only,Chrome Steel Ball Bearing,size 6202 for ceiling fan as per OEMs specifications. (Make: TATA/NBC/SKF)
Supply Only,Chrome Steel Ball Bearing,size 6204 for ceiling fan as per OEMs specifications. (Make: TATA/NBC/SKF)
Supply Only Ceiling Fan blades made out of 1.00 mm thick aluminium sheet, painted/powder coated finished,1200 mm/ 1400 mm sweep as per OEMs specifications. .
Supply Only, Exhaust Fan blade set (Three Nos. Blades) made out of 1.00 mm thick aluminium sheet, painted/powder coated finished,300 mm/ 450 mm/ 600 mm sweep/size as per OEMs specifications. .
Supply Only,Molded polypropylene canopy for upper and lower end of down rod,with fixing arrangement and screw as per OEMs specifications. .
Supply Only, Rubber bushing for upper end clamp of down rod in ceiling fan as per OEMs specifications.
Taking down carefully, existing defective storage type water heater (geyser) of Capacity 25/50 Litres of any Make for repairing, including replacement of defective spares as required including descaling of storage tanks internally, brazing of leakage if any in tanks and including replacement of terminals with defective connection wires and reinstallation of the geyser in original position including testing and commissioning,complete all as specified and directed. NOTES:- (i) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Spares for replacement will be measured and paid separately.
Supply Only,Thermostat, stem type,adjustable upto 75 Degree Celcius, ISI Marked (IS 3017).
Supply Only,Heating Element, 2000 Watts for geyser as per OEM's specifications.
Supply Only,brass pressure relier valve suitable for geyser as per OEMs specifications.
Supply Only,Glass Incandescent Electric Water Heater Indicator Lamp, in multi-color caps as per OEMs specifications..
Supply Only,apparatus plate suitable for geyser as per OEMs specifications.
Supply Only,glass wool for insulation purpose suitable for geyser as per OEMs specifications.
Supply Only,brass non return valve,15 mm size suitable for geyser as per OEMs specifications.
Supply Only,stainless steel storage tank suitable for 25 Litres capacity geyser as per OEMs specifications.
Supply Only,stainless steel storage tank suitable for 50 Litres capacity geyser as per OEMs specifications.
Supply Only,600 mm long,PVC Hot/Cold water connections,15mm size,with brass nuts .
Materials and Labour for painting of storage type water heater (geyser) of Capacity 25 Litres complete with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust etc. including writing MES No.etc.,complete all as specified and as directed.
Materials and Labour for painting of storage type water heater (geyser) of Capacity 50 Litres complete with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust etc. including writing MES No.etc.,complete all as specified and as directed.
Materials and Labour for galvanized steel tubing, medium grade, 15 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor,including taking up or down existing steel tubing ,complete all as specified and directed.
Supply and Fix in repair,gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe,15 mm bore, complete all as specified and directed.
Supply and Fix in repair, 3-Pin plug top 16 Amps,complete all as specified and directed. (Code No.39582 of Make Anchor or equivalent of Make Kinjal/Havells)
Supply and Fix in repair,PVC insulated and FR PVC round sheathed cable with copper conductor (flexible),nominal area of conductor 4.0 sq mm, 3 core, 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable,complete all as specified and directed.
Supply and Fix in repairs,single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240V, complete all as specified and directed. [Cat No. 5078 11 of Make Legrand or equivalent Model of Make L&T/ Hager/ Seimens/ GE/ Schneider/ABB]
Supply and Fix in repairs,metal frame and louvers suitable for exhaust fan,steel body AC single phase,230V of size 300 mm sweep,complete all as specified and directed.
Materials and Labour for,earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire, complete all as specified and directed.
Materials and Labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanised steel earth lead wire 4 mm dia. by means of bolts, nuts check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No 3 of SSR Part –I (2009) including testing on completion.
M/S SHIVAYA ENGINEERING
Singhs Construction
M/S N G CHOWDHURY
M/S R.B. Construction
SHRI D. C. BISWAS
M/S Annu Electronics
M/s A.Rahim Talukdar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .