Loading…
Loading…
Tender Value
₹57.6 L
EMD Value
₹58,000
Closing Date
9 Jul 2026, 6:00 pm
Similar tender results from the same govt authority in the past 3 years.
Additional City Engineer & I/c. City Engineer
CONSTRUCTION OF CONVENTIONAL TYPE BRTS BUS SHELTER AT RATNAMALA JUNCTION,UNDER FLYOVER BRIDGE IN NORTH (KATARGAM)ZONE, SURAT(WORK NO.01)(2nd Attempt)
315564
ACE & I/C C.E./Traffic BRTS Pro. Cell/02/2026-2027,(WORK NO.01)
Open
Civil Works
Surat
3 documents required · 3 mandatory
₹2,832
Commissioner, Surat Municipal Corporation
₹58,000
19 Jun 2026
19 Jun 2026
19 Jun 2026
9 Jul 2026
19 Jun 2026
Name of Work :- CONSTRUCTION OF CONVENTIONAL TYPE BRTS BUS SHELTER AT
RATNAMALA JUNCTION,UNDER FLYOVER BRIDGE IN NORTH (KATARGAM) ZONE, SURAT
(WORK NO.1) (2nd Attempt)
Location - Katargam
SMC - S.O.R. 2024-25
Description Qty. Rate Unit Amount
WORK UP TO PLINTH LEVEL
Providing and installing barricades including supplying,
paiting with flourscent paint/white paint and fixing CGI
sheet 24 SWG of required height as per site condition
and M.S. angle of required size to restain at 2.5 mt. c/c
1 and dismantalling the same after completion of work 210.00 124.72 S.M.
and allowing for movement of traffic as per drawing
and as per instruction from engineer in charge
(SOR -Road work-SMC 2023-24, Pg No. 13, It No.
1,PART-V)TRAFFIC SAFETY,TRAFFIC CONTROL AND
Reuse of the above barricades in item 24.1 for traffic
2 safety purpose without procuring new barricades. 210.00 28.32 S.M.
(SOR -Road work-SMC 2023-24,, Pg No. 13, It No.
2,PART-V)TRAFFIC SAFETY,TRAFFIC CONTROL AND
Provision of Solar Blinkers For barricading for limited
period at suitable locations as per requirement during
the construction in construction zone comprising of
warning zone, approach transition zone, working zone
and terminal transition zone Etc.
(SOR -Road work-SMC 2023-24,, Pg No. 13, It No.
6,PART-V)TRAFFIC SAFETY,TRAFFIC CONTROL AND
Demolition including stacking of serviceable materials
4 with all lead and lift. (i) RCC Work
(SOR SMC 2024-25, Pg No. 18, It No. 1) Demolition
Items / Items for Scrap Value
Excavation for foundation including sorting out and
stacking off useful materials and disposing of the
excavated stuff up to 50 mt. lead and all lift, watering
(A) loose or soft soil with Manual Labours
Description Qty. Rate Unit Amount
SMC SOR 24-25, PAGE NO 1 IT NO
Disposing off the excavated stuff of above items for
lead of (E) 400 to 500 m
Boring holes 3.5 mt.deep in ordinary soil ( for cast
in situ piles) & disposal of the surplus excavated
soil as directed within a lead of 50 M. For
following diameter of piles.
SMC SOR 24-25, ITEM NO. 94, PG. NO.
Earthwork for embankment including breaking
clods, dressing with all lead and lift and including
watering rolling and consolidation of subgrade in
8 layers at O.M.C. to required dry density including 6.00 176.15 C.M.
filling the depression which occur during the
process using power roller 8T to 10T.(E) From
Borrow area within 3.0KM. lead (more than
R & B SOR, ITEM NO.- 26004EA
Providing & laying C.C 1:3:6 (1cement : 3 coarse
sand : 6 Crushed stone agg 20m.m Nominal size)
&curing comp. excl. cost of form work in :(a)
foundation & Plinth
SMC SOR 24-25, PAGE NO 1 IT NO 5 21.00 3,095.25 C.M.
Providing & laying cement concrete 1:2:4 (1
cement : 2 sand : 4 graded stone agg. 20 mm
nominal size) & curing comp. Includ. cost of form
work but exclu. Cost of reinforcement for
reinforced concrete work in : Grade Slab
(C) Grade slab 23.00 3,741.69 C.M.
(SOR SMC 24-25 Pg No. 9 It No. 95)
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M25 Design mix concrete
as per IS 456:2000 (latest revision) and as per
tender specification in all items including cost of
form work and rendering but excluding cost of
(A) foundation, footing, base of columns and mass
SMC SOR 24-25, PAGE NO 14, Design Mix
Description Qty. Rate Unit Amount
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M25 Design mix concrete
as per IS 456:2000 (latest revision) and as per
tender specification in all items including cost of
form work and rendering but excluding cost of
(1) Having cross sectional area up to 0.085sq.mt. 0.00 12,930.68 C.M.
(2) Having cross sectional area more than 0.085 sq.
mt .up to 0.12 sqmt.
(3) Having cross sectional area more than 0.12 sq.
SMC SOR 24-25, PAGE NO 14, Design Mix
(1) Having cross sectional area upto 0.08 sq.mt. 0.00 9,083.57 C.M.
(2) Having cros sectional area more than 0.08 sq.
mt and upto 0.12 sq.mt.
(3) Having cross sectional area more than 0.12 sq.
(G) Vertical and horizontal fins 0.00 9,483.21 C.M.
SMC SOR 24-25, PAGE NO 14, Design Mix
Providing & laying C.C 1:3:6 (1cement :3 coarse
sand :6 crushed stone agg. 20 m.m Nominal size)&
curing comp. incl. cost of from work in: wall caps/
Providing & fixing IS Mark TMT Bar FE 500d
reinforcement for R.C.C. work incl. bending,
binding & placing in position etc.comp.---Ground
Upto G.L./P.L. 5945.00 77.29 Kg.
(SOR SMC 24-25,Pg No. 1 It No. 8)
Providing & construction brick work using Fly Ash
bricks having crushing strength not less than
Kg./sq.cm. in foundation & plinth in C.M. 1:6 (1
cement:6 sand ) etc. comp. - Ground Floor,P.L.
Filling available excavated earth (excluding rock) in
trenches. plinth, sides of foundations etc. in layers
16 not exceeding 20 cm. in depth consolidating each
disposited layer by ramming and watering.
(SOR SMC 24-25, Pg No. 1 It No. 10) 75.00 136.92 C.M.
Description Qty. Rate Unit Amount
Filling in foundation and plinth with murrum or
selected soil in layers of 20cm. thickness including
watering, ramming and consolidating etc.
carrying out plinth treatment to post
construction/existing structure by spraying
chemical solution for termite control treatment
including labour and material consisting with ISI
specification using chlordene and chiorpurfiles
18 EC as per 6131_part II concentration weight one 97.00 87.03 S.M.
litter give 1% concentration inclusive of one litter
chemicals emulsions application at the rate of
litter chemicals /sqmt of surface is recommended
(SOR SMC 24-25, Pg No. 12 It No. 127)
Providing & Applying 20mm. Th. Heavy Roller
plaster on walls or similar surfaces at all floor
levels consisting of 12 mm av. Th. Backing coat of
C.M. 1:3 (1 cement:3 sand) & 8 mm. th. Finishing
19 coat of C.M. 1:1 (1cement: 1 sand) apply thick 82.00 324.00 S.M.
cement slurry and apply roller horizontal as well as
vartical ( two times ) up to good quality and size of
grain in elevation as per directed by engineer
(SOR SMC 24-25, Pg No. 3 It No. 28)
Description Qty. Rate Unit Amount
Providing & applying two coats of weather shield max
paint (3 coats may be required in case of darker
colours.)of ICI Dulux or Apex Ultima of Asian Paint
including applying exterior acrylic primer coat as per
manufacturers specification and directions in shade and
colour approved by architects, on exterior surfaces of the
building including scaffolding, preparing the surface,
watering, curing etc. complete and as directed by the
architects and manufacturers Surface Preparation :
surface is thoroughly clean, dry and free from all loose
dirt, chalk, grease, fungi,algae and flaking paint. This can
be achieved by brushing with a wire/ stiff coir brush,
20 followed by water jetting if required. Fill up all minor
cracks and defects with white cement and sand mixture in
the ratio 1:3. For application on previously painted wall,
previous coatings of paint must be thoroughly scraped off
and Clean the surface thoroughly using wire
brushes.Priming: Apply a liberal coat of exterior acrylic
primer and allow it to dry for 4-5 hours.Application of
putty is not recommended.
Minimum 4-6 hours duration is required between each
coat of weather shield max paint
SMC SOR 24-25, , COLOR WORK ITEM NO.- 17 82.00 82.00 S.M
TOTAL COST UP TO PLINTH-(A)
WORK ABOVE PLINTH
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M25 Design mix concrete
as per IS 456:2000 (latest revision) and as per
tender specification in all items including cost of
form work and rendering but excluding cost of
(1) Having cross sectional area up to 0.085sq.mt.
Ground Floor 0.00 12930.68 C.M.
(2) Having cross sectional area more than 0.085 sq.
mt .up to 0.12 sqmt.
Ground Floor 4.00 11253.32 C.M.
(3) Having cross sectional area more than
Ground Floor 0.00 9288.03 C.M.
(SOR SMC 24-25,Pg No. 14 ,Design Mix Concrete)
Description Qty. Rate Unit Amount
(1) Having cross sectional area upto 0.08 sq.mt.
Ground Floor 0.00 9083.57 C.M.
(2) Having cros sectional area more than 0.08 sq.
mt and upto 0.12 sq.mt.
Ground Floor 9.00 8155.37 C.M.
(3) Having cross sectional area more than
Ground Floor 1.00 7067.84 C.M.
(SOR SMC 24-25, Pg No. 14 ,Design Mix Concrete)
(2) Slabs having more than 8 Cm & upto 10 Cm
Ground Floor 0.00 7965.38 C.M.
(3) Slabs having more than 10 Cm & upto 13 Cm
Ground Floor 12.00 7377.92 C.M.
(4) Having more than 13 cm. Thickness
Ground Floor 0.00 6793.97 C.M.
(SOR SMC 24-25, Pg No. 14 ,Design Mix Concrete)
Ground Floor 1.00 9963.33 C.M.
(SOR SMC 24-25, Pg No. 14 ,Design Mix Concrete)
Ground Floor 3.00 7119.46 C.M.
(SOR SMC 24-25, Pg No. 14 ,Design Mix Concrete)
Providing & fixing IS Mark TMT Bar FE 500d
reinforcement for R.C.C. work incl. bending,
binding & placing in position etc.comp.---Ground
Ground Floor 5345.00 77.29 Kg
(SOR SMC 24-25, Pg No. 2 It No. 15)
Brick work using common burnt clay building
bricks having crushing strength not less than
kg./Sq.Cm. in Cement Mortar 1:6 (1- Cement : 6 -
fine sand)(C) Fly Ash Bricks
Ground Floor 17.00 4729.83 C.M.
(SOR SMC 24-25, Pg No. 2 It No. 16)
Description Qty. Rate Unit Amount
Half brick masonry in common brunt clay building
bricks having crushing strength not less than
Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
coarse sand ) in foundation and plinth (C)Fly Ash
Ground Floor 10.00 712.81 S.M.
(SOR SMC 24-25, Pg No. 2 It No. 17)
Providing & Applying 10mm.th.cement plaster in
single coat on brick/ concrete walls similar
surfaces for plastering & finished even & smooth
25 with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion
etc. comp. in C.M 1:3 (1 cement : 3sand) (A) For
wall and similar surfaces -- Ground Floor
(A) for wall and similar surfaces
Ground Floor 111.00 199.28 S.M
(B) for ceilings and soffits of stairs
Ground Floor 119.00 225.34 S.M
(SOR SMC 24-25, Pg No. 3 It No. 24)
Providing and fixing 150 mm wide, approved
quality chicken wire mesh (FRP / PVC)at junction of
brick work and RCC work or two dissimilar
26 surfaces, at all heights fixed by nails, rowal plugs or
tag by cement mortar 1:3 before applying the
plaster, including curing, scaffolding all complete
Ground floor 46.00 102.00 S.M
(SOR SMC 24-25 Pg No. 11 It No. 124)
Providing & Applying 20mm. Th. Heavy Roller
plaster on walls or similar surfaces at all floor
levels consisting of 12 mm av. Th. Backing coat of
C.M. 1:3 (1 cement:3 sand) & 8 mm. th. Finishing
27 coat of C.M. 1:1 (1 cement: 1 sand) apply thick
cement slurry and apply roller horizontal as well as
vartical ( two times ) up to good quality and size of
grain in elevation as per directed by engineer
Ground Floor 132.00 324.00 S.M
(SOR SMC 24-25.Pg No. 3 It No. 28)
Description Qty. Rate Unit Amount
Providing & applying single coat of textured finish
at external surface at all floor levels with three
coats of weather proof exterior paint of approved
standard brands make (Asian/Dulux/Narolac) or
Equivalent at outer side of the building on RCC or
Masonary walls. Rate to include for all labour,
materials, staging, scaffolding, cleaing, curing etc.
application of texture after throughly brushing
th`e surface to give an even shade free from
mortar dropping/other foreign matter etc.
complete. application of textures & paints must be
as per company's standard instructions. Texture
and colour selection as per approved by engineer
RATE ANALYSIS -
Providing throating or plaster drip and moulding it
to R.C.C. chajja etc. comp.. For all floor
Ground Floor 29.00 43.74 R.M
(SOR SMC 24-25, Pg No. 3 It No. 29)
Providing 20 mm deep finished groove in plaster in
line and level etc. Comp. For all Floor (M.R.)
Ground Floor 72.00 50.00 R.M
(SOR SMC 24-25, Pg No. 3 It No. 30)
Providing & applying two coats of weather shield max paint
(3 coats may be required in case of darker colours.)of ICI
Dulux or Apex Ultima of Asian Paint including applying
exterior acrylic primer coat as per manufacturers
specification and directions in shade and colour approved by
architects, on exterior surfaces of the building including
scaffolding, preparing the surface, watering, curing etc.
complete and as directed by the architects and
manufacturers Surface Preparation : surface is thoroughly
31 clean, dry and free from all loose dirt, chalk, grease,
fungi,algae and flaking paint. This can be achieved by
brushing with a wire/ stiff coir brush, followed by water
jetting if required. Fill up all minor cracks and defects with
white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous coatings of
paint must be thoroughly scraped off and Clean the surface
thoroughly using wire brushes.Priming: Apply a liberal coat of
exterior acrylic primer and allow it to dry for 4-5
hours.Application of putty is not recommended.
Minimum 4-6 hours duration is required between each coat
SMC SOR 24-25, , COLOUR WORK ITEM NO.- 17 132.00 82.00 S.M
Description Qty. Rate Unit Amount
NOTE :- (1) The whole work is to be executed
through specialized agency with a guarantee of
(Ten) years given on a prescribed proforma duly
stamped (2) The rate shall include for work
at all floors & conducting water proof test as
directed. (M.R.)
(B) Providing and laying integral cement based water
proofing treatment including preparation of surface as
required for treatment of roofs, balconies, terraces etc.
consisting of following operations. (a) Applying and grouting
a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with proprietary water proofing compound
comforming to IS:2645 over the R.C.C. slab including cleaning
the surface before tratment. (b) Laying cement concrete
using broken bricks/brick bats 25 mm to 100 mm size with
32 50% of cement mortar 1:5 (1 Cement : 5 Coarse sand)
admixed with proprietary water proofing compound
conforming to IS:2645 ,brick bats is finally covered by
jointless cement plaster 20mm th. in C.M. 1:4 added with
special water proofing compound confirming to IS:2645 &
top smooth finished with trowel with false chequered
marking of 300 mm.size.The treatment is carried along the
vertical surface of the parapet & other adjoining wall up to
height of about 300 mm in a shape of quarter round vata Incl.
curing etc. Comp. With average thickness of 120 mm and
SMC SOR 24-25, Page no-6.ITEM NO.- 62-B 104.00 511.00 S.M
Providing and laying broken china mosaic flooring for
terrace using 12mm to 20mm broken pieces of glazed
tiles to be laid over cement mortar 1:3 to plain or slope
and to be tempered to bring mortar creme out upto
surface using white cement including rounding off
junctions and extending them upto 15 cm along the
wall clearing with water and oxalic acid etc. as directed.
SMC SOR 24-25, Page no-6.ITEM NO-131 104.00 779.70 S.M
Providing and laying polished Kota stone slab flooring
over 20mm (Average) thick base of cement mortar 1:6
(1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty
:1.5 - coarse sand) laid over and jointed with grey
cement slurry mixed with pigment to match the shade
of slab including rubbing and polishing etc. complete.
Providing and laying polished kota stone slab 25mm
thick in risers of steps,skirting Dedo and pillars laid on
10mm thick cement mortar 1:3 (1- Cement : 3 coarse
35 sand) and jointed with gray cement slury mixed with
pigment to match the shade of slab including rubbing
and polishing etc. complete
Description Qty. Rate Unit Amount
Apply two coats of putty and two coats of primer
of approved brand and manufacture on new wall
surface to give an even shade including thoroughly
brushing the surface free from mortar dropping
and other matter and sand papered smooth.
(SOR SMC 2024-25, Pg No. 15, It No. 4,Colour works) 230.00 40.59 S.M
Wall painting (two coats) with plastic emulsion
paint of approved brand and manufacture on
undecorated wall surface to give an even shade
including throughly brushing the surface free from
mortar droppings and other foreign matter and
sand papered smooth.
(SOR SMC 2024-25, Pg No. 16, It No. 5,Colour works) 230.00 83.36 S.M
Providing and fixing precast Rubber Dye
moulded TECTILE concrete flooring tiles, 25 to
30mm avg. thick with grade of concrete M250
pnumatic compressed and Mechanically vibreted
38 and as per approved design over 20mm thick bed
of cement mortar 1:6 jointed with neat cement
slurry with pigment to match the shade of tiles in
proper line & level etc.complete.
RA-Tectile flooring 11.00 3042.47 S.M
Providing & fixing U-PVC pipes Confirming to IS no.
13592 (Type "A") of Prince/Supreme/Jain/Astral/
Tulsi/Finolex make for rain water at all floor levels incl.
39 fixtures like bends, tees, shoe etc joined with resin of
approved brand & manufacture etc. comp. (M.R.) (B)
(SOR SMC 24-25, Pg No. 8 It No. 85) 40.00 325.00 R.M.
Providing & fixing G.I./Aluminum Patti clamps at all
floor levels of approved design to C.I. Or S.C.I pipes
including the cost of cutting holes & making good the
wall etc. Complete - 100 mm. dia. (M.R.)
(SOR SMC 24-25, Pg No. 8 It No. 91) 10.00 20.00 No.
Providing & Fixing Kathi around the vertical PVC
drainage pipes for concealing with cement plaster
41 mm avg thickness(CM 1:3 [1 cement :3 coarse sand])
finishing as per instruction given by Eng. incharge. For
(B) 100 mm /110 mm PVC PIPE
(SOR SMC 24-25, Pg No. 9 It No. 93) 20.00 180.00 R.M.
Description Qty. Rate Unit Amount
Providing and fixing stainless steel ( Grade 304)
railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and
making curvature (wherever required) and fitting
the same with necessary stainless steel nuts and
bolts complete, i/c fixing the railing with necessary
accessories & stainless steel dash fasteners
42 stainless steel bolts etc., of required size, on the
top of the floor or the side of waist slab with
suitable arrangement as per approval of Engineer-
incharge, (for payment purpose only weight of
stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts,
fasteners etc.).
Providing and fixing stainless steel ( Grade 304)
(Flat of size 30mm x 5mm. thick), gill with 10mm.
Dia S.S.polished bar etc., including welding,
grinding, buffing, polishing and making curvature
43 (wherever required) and fitting the same with
necessary stainless steel nuts and etc., of required
size as per approval of Engineer-incharge, as per
drawing .(for payment purpose only weight of
stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts,
Providing & fixing in position collapsible steel
shutters with vertical channels 20 x10 x 2 mm.
Braced with flat iron diagonals 20 x5mm size with
44 top & bottom rails of T-iron 40x40x6mm. with
38mm dia. steel pulleys comp. with bolts, locking
arrangements, stoppers, handles incl. applying a
priming coat of Redlead paint etc. comp.
Description Qty. Rate Unit Amount
Providing and fixing of 8 mm thick toughned GLASS
DOORS using 75 mm C-channels in border and
edge profile in between with powder coating with
using Dorma Xl-C 4001 Glass Door PKG EN 3 (Top
Patch-1, Bottom patch-1, Heavy duty Floor Spring-
1, Corner Lock-1); Dorma Xl-C 4003 A Patch fitting
for overpanel and sidelight; Dorma Xl-C 4004 A
Connector for overpanel and Sidelight; Dorma Xl-C
45 4006 Central Connector; Dorma Xl-C 4008 Side 1.00 36337.92 Each
Connector; Dorma Xl-C 3000 H Type Handle
400x22 CTC 300 AND AS PER DRAWING including
all acceessories,locks, material,
silicone,labour,installation, Hole & slote charges
etc. and complete the work satisfactorily as per
instruction of architect or Engineer-in charge.
R.A.-Glass door
Providing and constructing sandwitch type Granite
stone working platform 0.6 mt. wide & 0.75 mt.
height, including one end side granite stone
(Double Polish) of 1.25 mt. height & front granite
46 stone patti of 10 cm wide, vertical partitions of half 3.00 3128.00 R,M,
B.M. wall in C.M. 1:4 and 10mm th. plaster in 1:3
with finishing smooth with cement slurry as
required etc. comp as per instruction given by site
in charge at all floors. (Basic rate of Granite
(SOR SMC 2024-25, Pg No. 11, It No. 123)
Providing and fixing 8mm thick glass of approved
make including toughening, edge diamond
polishing, making necessary holes in glass,
47 supporting system of good quality SS accessories 7.00 2825.98 S.M.
of Ozone make ("D" clamp fittings) and joints to be
filled where necessary by clear structural silicon
sealant as specified by Engineer in Charge.
R.A-Glass partition for Ticket counter
Fire extinguisher - CO2 Gas type 4.5 kg. Supply,
installation and testing of CO2 Gas fire extinguisher
with necessary hardware and consumables. Standard -
Confirming to IS:15683-2006 with ISI mark. UOM - Price
per each No. Make - Kanex / Safex / Secure Zone
(SOR SMC 2024-25, Pg No. 12, It No. 136)
Description Qty. Rate Unit Amount
Fire extinguisher - ABC powder type 6 Kg. Supply,
installation and testing of ABC powder fire extinguisher
necessary hardware and consumables. Stored pressure
49 mechanism. Charged with MAP-50% (ABC) Dry powder. 2.00 2000.00 Each
with wall mounting clamp. UOM - Price per each No.
Make - Kanex / Safex / Secure Zone
(SOR SMC 2024-25, Pg No. 12, It No. 135)
Providing and fixing 3-sitter S.S. Bench made of 32mm x
5mm thik S.S. Flat (SS 304 Grade) with top seatting
arrangement made of Polished Indian teak wood
Sleeper of section size 200 mm x 25mm(W x H),and
fixing the bench at the specified location as per detail
drawing and instruction of architect or Engineer-in
Rate Analysis Bench-3 Seater 3.00 9330.00 No.
Providing and fixing of cement ceiling using 10 mm
cement sheet of brand T.P.I,SHERA (single sides), etc.
using aluminium framing of 25mm x 50mm x 1 mm in
600 x 600 mm grid,and same pipe for vertical framing,
including all hardware item, aluminium L clits, 25 mm
powder coated self drilling screws,groove (if shown)
51 with all material, 75 mm anchor fastners,making of
coves for indirect lighting, grooves,cutting
,labour,SCAFFOLDING, lead and wastage etc. complete.
And Finished with satin finish wall color and complete
the work satisfactorily as per instruction of architect or
Engineer-in charge.
R.A-Cement sheet ceiling 105.00 2356.00 SM
Steel work welded in built up sections, framed
work including cutting, hoisting, fixing in position
and applying a priming coat of red lead paint (A) in
52 beams & joists channels angles, tees, flats with
connection plates or angle cleats as in main &
cross beams,hip & trussed purlins connected to
common raffers & the like
(SOR SMC 24-25, Pg No. 9 It No. 98-A) 23.00 9108.48 Qtl.
Providing and fixing 12mm dia Fasternar bolts using
53 HILTI chemical system incluing all material, labour,
equipment required.
Description Qty. Rate Unit Amount
Providing and erecting on site 6mm thick colour acrylic
sheet with 3M make Defuser film of UV resistant type
with graphic profile cut in colour acrylic. The entire
surface shall be water proof and air tight with necessary
gaskets. The corners shall be properly made. The acrylic
54 to acrylic joints at the corners shall be evenly
chamfered before sticking. The item includes necessary
hardware to fix the acrylic signage to the MS structure.
Do as specified by Engineer in Charge.
SMC APPROVED RATE (Public Transport Mobility
Comm. Res.No. 04/2024 Dt. 08/02/24
Providing and fixing in position 10mm thick acrylic
sheet UV resistant as per designs on ETM counters for
signages. The acrylic sheet shall be firmly screwed to
the M.S. members so as to withstand wind speeds upto
47m/s. The joints of the sheets shall be well
champhered and jointed using silicone sealants of Dow
corning. The rates shall be inclusive of all kinds of
scaffolding, staging, tools, tackles, hardware and
adhesives. The work shall be done to the complete
satisfaction of the Engineer in charge.the complete
satisfaction of the Engineer in charge.
SMC APPROVED RATE (Public Transport Mobility
Comm. Res.No. 04/2024 Dt. 08/02/24
Providing and fixing in position 8mm thick acrylic sheet
UV resistant as per designs on ETM counters for
signages. The acrylic sheet shall be firmly screwed to
the M.S. members so as to withstand wind speeds upto
47m/s. The joints of the sheets shall be well
56 champhered and jointed using silicone sealants of Dow
corning. The rates shall be inclusive of all kinds of
scaffolding, staging, tools, tackles, hardware and
adhesives. The work shall be done to the complete
satisfaction of the Engineer in charge.
SMC APPROVED RATE (Public Transport Mobility
Comm. Res.No. 04/2024 Dt. 08/02/24
Description Qty. Rate Unit Amount
Providing and installing in position HDPE synthetic
Fiber carry rollers of 100mm dia as instructed by
Engineer in Charge. The rollers shall have seals
which are with labyrinth seal components, non-
rubbing polymer seal and attached with dust and
water deflectors. The rollers shall be such that they
shall have good rolling during impact and shall not
57 damage the body of the bus nor shall get damaged
during impact and shall act as a protecting
mechanism for the bus and the surface of the bus
shelter. The installation of the rollers shall be as
per the instructions of the manufacturers. Samples
shall be approved prior to installation. Roller shafts
shall be made of stainless steel and multi labyrinth
seals shall be filled with high grade lubricants.
SMC APPROVED RATE (Std Com. Res.No.
Providing & Laying Cement concrete guardstone in
proportion 1:2:4 (1 Cement : 2 Coarse sand : 4 Graded
stone aggregate 20 mm nominal size) & shape as per
58 the drawing including necessary excavation steel form
work & white washing etc. complete (cement and steel
contractor own supply.) 750 MM X 350 MM X 400 MM
(M.R.) Approved in S.W (Athwa zone) 100.00 656.00 No.
Providing & fixing interlocking type Cement
Concrete paver block of approved shape & design
having 60 mm thickness (M-40) purchased from
SMC's approved paverblock manufacturer only on
59 fine sand bedding. Item includes leveling by using 0.00 553.00 S.M.
vibratory plates compacted machine. Item also
includes all materials, Labour, euipments, tools,
plants, watering, cleaning etc. complete.
For Road Junction 80 mm thick ( M-50) 18.00 714.00 S.M.
SMC SOR 24-25, GROUND DEVELOPMENT WORK
Preparation of subgrade with Compacting,
Levelling and consolidation of subgrade with
miniroller /plate vibrator machine including
watering and filling in depressions which occur
during the process as directed by engineer in
SMC SOR, GROUND DEVELOPMENT WORK
Description Qty. Rate Unit Amount
Providing & laying Granular sub base
(GSB)confirming to Grading-V of Table 400.0 of
compacted thick of 150mm with specified graded
stone metal and sand mixed in place and laid with
61 mechanical means spreading with motor grader 41.00 1,469.00 C.M.
and compacting with vibratory roller having
minimum 80-100 KN static weight to acheve
desired density of 98% of MDD including all
material, labour, machinery with all leads and lift
SMC SOR, GROUND DEVELOPMENT WORK
Providing and laying 200 micron plastic sheet on
prepared sub base For V.D.S Concrete
SMC SOR, GROUND DEVELOPMENT WORK
Providing & laying cement concrete Pavement
using 1:1.5:3 (1 cement:1.5 sand:3 graded stone
63 agg. 20 mm nominal size) & Vaccuum Dewatering 41.00 5981.00 C.M.
technique including floating surface with a skim
powder floater, curing etc. complete.
SMC SOR 24-25, GROUND DEVELOPMENT WORK
Cutting of Groove 5 to 7 mm thick in VDS for depth
64 1/3 of total thickness with filling of epoxy sealent 45.00 50.00 R.M.
as directed by engineer in charge
SMC SOR 24-25, GROUND DEVELOPMENT WORK
Providing 100mm thick readymade C.C. kerb of
strength M-20 (size 300mm x 380mm) purchased
from SMC's approved paverblock manufacturer &
setting in line, level and in truly vertical position,
65 including filling joints in C.M. 1:1 (1 part of cement 10.00 228.0 R.M.
: 1 part of stone dust) smooth pointing in C.M. 1:1
(1 part of cement : 1 part of coarse sand) including
watering etc. complete and as directed by
engineer in charge.
SMC SOR 24-25, GROUND DEVELOPMENT WORK
Providing and fixing Eco Solvent Vinyl Sticker (120
gsm) with Lamination (100 gsm)
(SOR SMC 2024-25, Pg No. 13, It No. 147)
TOTAL COST ABOVE PLINTH-(B)
Part-B Electrical Work R&B SOR 2025-26
Description Qty. Rate Unit Amount
Part-01 Internal Wiring & Light Fixture
Point wiring for Light / Bell with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type switch /
bell push & accessories and earth continuity of
following type, erected on PVC / Metallic/Wooden
67 box, single mounting base frame covered with 20.00 485.81 Pt.
textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose /
H.D.Connector as directed. (f) with medium class
Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete Cat. III
68 Primary light point controlled by one SP MCB 5.00 585.80 Nos
Secondary light point controlled by same switch /
Point wiring for Tissino / Modular secondary light
point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires, in below
type of pipe to be erected complete with earth
continuity and necessary connection with primary
light with accessories erected on Metal / PVC /
70 wooden box covered with 3 mm thick 10.00 167.66 Pt.
PC(Polycarbonate) / Acrylic sheet for open /
concealed wiring. with necessary Lamp holder /
ceiling rose / H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm & earth wire
of 1.5 sq.mm (Green) both are of .ISI marked
KV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of
pipe erected with 6A Modular type switch and
hum free EME step type electronic fan regulator
mounted and accessories with earth continuity of
following type erected on PVC / Metallic/Wooden
71 box, single mounting base frame covered with 1.00 674.68 Pt.
textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as
directed. (f) with medium class Rigid PVC pipe
and accessories erected concealed in
wall/ceiling complete Cat. III
Description Qty. Rate Unit Amount
Point wiring for Individual Plug with & earth wire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe
erected complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden box
covered with appropriate front plate modules
72 erected on / in wall / ceiling as per pipe erected 8.00 510.05 Pt.
with following type of accessories.[I] For 6A Plug
and 6 a switch with 2-1.5 sq.mm Cu. Wire from
nearby switchboard/mcb db board.(f) with
medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat.
Point wiring for Individual Plug with & earth wire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe
erected complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden box
covered with appropriate front plate modules
73 erected on / in wall / ceiling as per pipe erected 6.00 745.38 Pt.
with following type of accessories.[II] For 16A Plug
and 16 amp switch with 2-2.5 sq.mm Cu. Wire
from mcb db board.(f) with medium class Rigid
PVC pipe and accessories erected concealed in
wall/ceiling complete Cat. III
DO - as 1.1.5 but with4 sq.mm wire for phase &
Neutral & 2.5 sq. mm for Earthing
-Do- as 1.1.6 but With 20 Amp DP switch and
socket at different location
Point wiring for on board Looped Plug with 6A
Modular type switch & 5 pin socket erected on PVC
/ Metallic/Wooden box, single mounting base frame
covered with textured /metallic/white front plate
modules erected on / in wall / ceiling with following
type accessories Cat. III
Wiring for the UPS / Comp. / Raw Power outlet
with 2 nos. of 250 volts single phase and neutral
16 amps switched socket outlet with 4 sq mm x
core FRLS Round flexible copper conductor
volts grade wires of approved make in
concealed or surface mounted Prelaid 25 mm dia
77 medium guage PVC Conduit / Race ways including 2.00 1333.20 Nos
providing and fixing of 2 no.s of 16 amps 5 pin
switch socket outlet of approved quality colour
make & design in 2 mm thick GI box and
earthing of fixtures and the outlet box . (
Maximum 2 nos. of Plugs can be looped in
Description Qty. Rate Unit Amount
Providing following type of Modular Type
Accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with
textured / metallic/white front plate , modules
erected with necessary connections as per site
situation directed by Engineer In charge. (4) TV Co-
axial Socket outlet Cat. III
Providing & erecting Switch board for Computer
or electric apparatus consisting of following
modular type accessories mounted with PVC /
Metallic concealed/open box with single mounting
base frame covered with textured/metallic /white
front plate,modules erected with necessary
connections as directed.
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug Cat.III
Supplying & erecting approved make LAN cable of
80 following size in existing pipe as per direction [C] 50.00 76.76 Mtr
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to be
erected on/in wall or ceiling erected with necessary
81 PVC fittings & Junction boxes fixed with adhesive 60.00 24.24 Mtr
solution & Clamps with following dia of pipes, in
approved manner as directed.(a)20 mm
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to be
erected on/in wall or ceiling erected with necessary
82 PVC fittings & Junction boxes fixed with adhesive 50.00 33.33 Mtr
solution & Clamps with following dia of pipes, in
approved manner as directed.(b) 25 mm
Providing and fixing 350 x 350 x 40 mm deep
mm thick GI sheet junction box including providing
3 mm thick stainless steel cover as per
Supplying, Fabricating, Installtion, Testing &
Commissining of the 2 mm thick CRCA sheet Steel
Powder Coated MS box as per the approved
Design with locking Arrangement
Supplying and laying UPVC cable trunking system
comprising unplasticised polyvinyl, chloride rigid
material with ignition free and flame proof
confirming BS with necessary end caps Internal
and external bend, flat bends, coupler, tee etc..All
necessary accessories and measuring of following
sizes (2) 100 mm x 50 mm trunking
Description Qty. Rate Unit Amount
Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with
smooth finish powder coated and heat sink
extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass
with company mark/name engraved or embossed
160 to 270 V,Power Factor more than 0.95, THD <
10 %, CCT 3000 K to 5700K,Uniformity ratio
86 >0.45, Luminaire efficacy> 100 lumens/watt . LED 4.00 3345.12 Each
driver efficiency > 85 %.( fittings required LM-79 &
LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A)
Street Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line
supply with over-voltage protection. (i) above
36 to 48 watts Cat-lll
Supplying and erecting Street light pole bracket
comprising main B Class GI pipe of 4.2 cm/require
outside dia. complete with suitable B Class G.I.
sleeve tubing of approx. 45cms.length and suitable
for 76.5mm/80mm/require size of pole top having
nuts and bolts for fixing the brackets and having
87 spread of 0.5 mtr. Length with 110 deg.with vertical 4.00 491.87 Each
plane and suitable welded stiffener reducer and
nipple with check nut complete painted with one
coat.of Red oxide / PU base primer and two coats
of Aluminium / PU paint. paint with following nos of
arms. [A] Single Arm bracket 0.5 Mtr
Description Qty. Rate Unit Amount
Supplying and erecting LED indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/aluminium pressure die cast
powder coated and high U.V. & corrosion
resistance with diffuser housed in aluminium
casted body with company mark/name
160V to 270V,Power Factor more than 0.9, THD <
15 %, CCT 3000 K to 6500K, Luminaire efficacy>
85 lumens/watt , LED driver efficiency > 85 % (
88 fitting required LM-79 & LM-80 Certificates)(NOTE: 26.00 758.51 Ea.
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges
shown.) (A) Square/ Circular shaped
Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips
complete.IP65 (iv) 22-24 watts, Surge-2 KV Cat-
Supplying and erecting LED indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/ aluminium die cast powder
coated and high U.V. & corrosion resistance with
diffuser with company mark/name 120 to
V,Power Factor more than 0.9, THD < 10 %, CCT
3000 K to 6500K, Luminaire efficacy>
lumens/watt ,LED efficiency110 lumens/watt LED
89 driver efficiency > 85 % CREE / OSRAM / PHILIPS 2.00 112.11 Each
Lumileds / NICHIA / SEOUL/Bridgelux make LED
used for luminaire. ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage
capacity between the ranges shown.) (A) LED
Lamps integral type,cool white with PC diffuser
suitable for B22 LAMP holder (b) 5 to 8 watts
Description Qty. Rate Unit Amount
Supplying and erecting LED indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/aluminium pressure die cast
powder coated and high U.V. & corrosion
resistance with diffuser housed in aluminium
casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD <
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage
capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed
Mount Downlight with provision for spring loaded
mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV
Providing & erecting Approved make Ceiling Fan
with double ball bearing with Condenser 230 volt
91 A.C.50 Hz. 900 mm sweep complete having 3 1.00 1982.63 Ea.
Aluminium blades, canopy erected complete. [
Make shall be approved by Engineer in Charge]
Supplying & erecting fan hook box of 10 mm M.S.
round bar bounded to the RCC bars up to 50mm
length each side and pierced through a 16 Gauge
M.S. box / Heavy Duty PVC box complete erected
concealed in Ceiling with necessary finishing.
Supplying and erecting 19 / 20 mm. nominal bore
Medium Class M.S. Pipe down rod erected duly
painted for fan complete with proper insulation
without leakage and earthing.
Supplying Table fan approved make A.C. 23OV,
c/s. 40 cm. sweep oscillating complete with 3 mtrs.
94 of 3core round flexible wire and 3 pin plug top. [ 2.00 1841.23 Ea
Make shall be approved by Engineer in Charge]
Supplying and erecting approved make Bracket fan
of 230 volt, A.C. 50 Cy/s., 400/450 mm sweep
complete erected on wall or with lead Cores and
connections complete. Cat.II
Subtotal Part-01
Part-02 LT Switchgear, Distribution Boards &
Description Qty. Rate Unit Amount
Providing and erecting Miniature circuit breaker
single pole 6A to 25A suitable to operate on 240 V
96 A.C. system and having breaking capacity 10 KA to 6.00 112.11 Each
be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III
Providing and erecting Sheet Steel powder coated
MCB distribution board - flush / surface mounted
fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of
97 MCBs.(The DBs should be used of same company 1.00 1152.41 Each
of MCB to be used) suitable for (A) single phase
incoming and horizontal single phase outgoing
(b) sheet steel double door (IP-43) (iii)8 way
Supply, Erecting, testing and commissioning of
only TPN D.B. PPI type with space for FPMCB as
98 incoming and space for DPELMCB and 16 SPMCB 1.00 4190.49 Each
as outgoing per phase (i.e. 3 tier x 13 way flexy
D.B.) of Legrand Make
Supply, Erecting, testing and commissioning of
only TPN D.B. PPI type with space for FP ELMCB
99 as incoming and space for 12 SPMCB as outgoing 1.00 3580.45 Each
per phase (i.e. 2 tier x 13 way flexy D.B.) of
Providing and erecting Sheet Steel powder coated
MCB distribution board - flush / surface mounted
fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of
100 MCBs.(The DBs should be used of same company 1.00 1152.41 Each
of MCB to be used) suitable for (A) single phase
incoming and horizontal single phase outgoing
(b) sheet steel double door (IP-43) (iv)12 way
providing and erecting Approved make RCCBs
conforming to IS: 12640 and having sensitivity
of 30 mA and Short Circuit withstand capacity
of 10 KA and suitable for operation on single
phase 240 V,50Hz. having characteristic of 2.00 1969.50 Each
quick action & tripping with all advance feature
& do not incorporate any electronic
component. for following Max. rating erected
as directed (i) 25 Amps.DP Cat. III
Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve) having
102 10 KA breaking capacity & confirms to IS : 8828 in 3.00 299.97 Each
existing box having following capacity (A) 6 to
Description Qty. Rate Unit Amount
providing and erecting Miniature circuit breaker
single pole 6A to 25A suitable to operate on 240 V
A.C. system and having breaking capacity 10 KA
to be erected in existing box. confirming to IS
8828/1996 with ISI Mark
Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity
105 25 A / 100 mA DP ELMCB 2.00 2323.00 Each
106 32 A / 100 mA DP ELMCB 1.00 2981.52 Each
107 40 A / 100 mA DP ELMCB 1.00 2636.10 Each
Providing & erecting 415 V MCB Four Pole for
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in existing
108 box having following capacity 1.00 595.90 Each
(a) 6 to 32 Amp.
Providing & erecting 415 V MCB Four Pole for
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in existing
109 box having following capacity 1.00 595.90 Each
(a) 6 to 32 Amp.
Providing & erecting 415 V MCB Four Pole for
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in existing
box having following capacity
astronomical Dual Channel Timer equivalent to
Legrand Make D22 Cat. No.
40 Amp DP Dinrail Mouned Contactor Equivalent
to Legrand make Cat. No.
63 Amp FP Dinrail Mouned Contactor Equivalent to
Legrand make Cat. No.
Sheets steel powder coated enclosure suitable for
incorporating One/Two nos. MCB.
Description Qty. Rate Unit Amount
Providing and erecting Sheet Steel powder coated
MCB distribution board - flush / surface mounted
fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of
115 MCBs.(The DBs should be used of same company 2.00 355.52 Each
of MCB to be used) suitable for
(A) single phase incoming and horizontal single
(a) single door (IP-30)
Subtotal Part-02
Part-03 Cables and Wires
Providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with
116 1.5 sq. mm copper conductor FRLS PVC insulated 30.00 82.82 Mtr
stranded wire of green colour for earth continuity of
following size.(A) with medium class Rigid PVC
pipe and accessories.(b) 2 wire 2.5 sq. mm )
Providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size(A)
with medium class Rigid PVC pipe and
accessories.(a) 2 wire 4 sq. mm
Providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size(A)
with medium class Rigid PVC pipe and
accessories.(h) 4 wire 6 sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe at road crossing or floor
of following size of cables. (A) 4 core 10 Sq. mm
Description Qty. Rate Unit Amount
providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and
(a) 2 wire 4 sq. mm
Providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
(A) With medium class Rigid PVC pipe and
(b) 2 wire 2.5 sq. mm
Providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with
122 1.5 sq. mm copper conductor FRLS PVC insulated 50.00 46.46 Mtr
stranded wire of green colour for earth continuity of
(E) in existing pipe
(a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with
123 1.5 sq. mm copper conductor FRLS PVC insulated 50.00 62.62 Mtr
stranded wire of green colour for earth continuity of
(E) in existing pipe
(b) 2 wire 2.5 sq. mm
Supplying & erecting approved make LAN cable of
124 following size in existing pipe as per direction 100.00 47.47 Mtr
Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor
125 for 1.1 KV. to be laid on wall with necessary 100.00 153.52 Mtr
clamps or in existing trench / pipe of following size
of cables (A) 4 core 16 Sq. mm
Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
126 armoured cable complete with out going tails, 10.00 47.47 Ea
insulating tape etc for following size of cables. (D)
2 to 4 core 16 Sq. mm
Description Qty. Rate Unit Amount
Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following size
evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
manner. (C) 16/25 Sq.mm.
Making trench in soft soil of suitable width of 90 cm
deep for laying cable or locating the fault all over
the run and back filling the same and making the
surface as normal ground.
Providing & laying approved make Double walled
corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
129 necessary connecting accessories of same 120.00 62.62 Mtr
material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable (A)50 mm outer dia
Providing & laying approved make Double walled
corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
130 necessary connecting accessories of same 50.00 95.95 Mtr
material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable (C))90 mm outer dia
Providing & laying. R.C.C. Hume pipe for cable to
be laid 90 cm. below ground across the road
131 crossing or on floor with necessary material in an 25.00 226.24 Mtr
approved manner and making the ground as per
original. (F) 100 mm dia.
Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
132 armoured cable complete with out going tails, 2.00 38.38 Each
insulating tape etc for following size of cables. (C)
2 to 4 core 10 Sq. mm
Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following size
evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
manner. (B) 10 Sq.mm
Subtotal Part-03
Part-04 Earthing and Automatic sliding Doors &
Providing and erecting HOT deep Galvanized iron
strip wire 8 to 16 SWG.
Description Qty. Rate Unit Amount
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having
200-250 Micron galvanising, connection terminal
dia of 12mm with constant ohmic value surrounded
by highly conductive compound with high charge
dissipation suitable for following type of
applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test
certificate including value of earth resistance of
installation duly stamped and signed by agency
and officer Incharge has to ensure the value of
earthing resistane mentioned in test Certificate) &
having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:-
0.2 ohm / meter testing as per IEC 62561-2017,
Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :-
Earthing compound should be capable to retain
moisture for long time Necessary test report must
be submitted by Agency. (b)For Electrical
installation up to 11 KV in normal soil.Length of
Pipe : 2.00 mtrs Back filling Compound :1 no. Bag
Providing and erecting required size HOT deep
Galvanised iron strip for earthing of H.T. , OCB/
ACB/ Transformer LT panel board, Motors etc.
using proper clamp.
Providing and erecting Annealed bare Copper wire
For using salt and charcoal / coke as required for
pipe type earthing.
Approval & Liasioning work for Obtaining the
necessary legal permissions from the concern
govrnment authorities, including to prepar drawings
before/after execution for the work etc complete as
139 directed by E.I.C (Certificate For LIFT, Highrise 1.00 1515.00 Job
Permission DG set. Also for Power supply meter
connection) It includes charges of Name Transfer
of Electric Meter of each flat as well as service
Description Qty. Rate Unit Amount
providng and erecting Approved make single
phase electronic energy meter rating 5A/20A/40A
based on ASIC (Application Specific integral
circuit) digital technology with accuracy Class-I,
temper proof, free from effect of external magnetic
field with phase, earth, reverse and impulse
indications, 6 digit electro-mechanical counter
suitable to work on 120 V to 300V, 45 - 55 Hz.,
housed in robust enclosure complete to be erected
as directed with 3 year replacement guarantee.
Providing and fixing 02 units Automatic sliding
Doors (2 leafs) of size as per drawing for items to
be fitted onto the Bus Station excluding any other
RF component.) with Four Door RF Controller with
2 RFID Reader with weatherproof Stainless-Steel
enclosure to be fitted near the bus door with
Emergency Door operations Switche in Ticket
office (inclusive of two-year warranty period) + Four
141 Door RF Controller (inclusive of two-year warranty 1.00 610890.42 Lot
period) + RFID Reader with weatherproof Stainless-
Steel enclosure to be fitted near the bus door
(inclusive of two-year warranty period) +
Emergency Door operations Switche in Ticket
office (inclusive of two-year warranty period) ( SD
unit Per Station .Each Unit comprise two leafs)
S & L only PVC Heavy gauge in concealed manner
142 with GI pulling wire of 25 mm dia with all 50.00 32.32 Mtr
S & L only PVC heavy gauge in concealed manner
143 with GI pulling wire of 32 mm dia with all 50.00 53.53 Mtr
Subtotal Part-04
Total Civil + Electrification work
SIGNATURE OF THE CONTRACTOR WITH SEAL. Executive Engineer
Surat Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Technical Bid Ratnamala Junction.pdf
Price Bid Ratnamala Junction.pdf
01 BRTS_STATION_STRUCTURE_DETAILS.PDF
OPTION-02.pdf
Download all tender documents and submit your bid