Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-Finance ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | L1 | Accepted-Finance Lowest | |
| 2 | L2₹1.8 L+₹12,677 (7.77%)Accepted-Finance ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | L2 | Accepted-Finance second Lowest |
Tender Value
Refer Docs
EMD Value
₹4,079
Closing Date
14 Aug 2026, 4:30 pmClosed
Assistant Executive Engineer
PWD ELECTRICAL SUB DIVISION IDUKKI
MLA SDF SITC of Solar security lights and UPS in ECHS Polyclinic Painavu
2026_PWD_864784_1
PWD/BLDG/TR/4536/2026
Open Tender
Electrical Works
Percentage
30 days
Cheruthony
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
Yes
₹4,079
Yes
7 Sept 2026
7 Aug 2026
17 Aug 2026
7 Aug 2026
14 Aug 2026
7 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1UPS and Inverter | |||||
| 1.001 | OD351265/2025-2026:Supply installation testing and commissioning of Philips 25W Solar Street Light Essential Smart Bright( BRC010 LED40/765)with IP65 Waterproof Street Light Includes wall mount bracket, Infrared remote for control with following features a) Color Temperature 6500K (Cool White) b) Lumen Output 4000 lumens c) Battery Type Inbuilt Lithium-Ion Battery d)Battery Backup Up to 12–14 hours (on full charge) e) Solar Panel Type Polycrystalline / Monocrystalline f) Charging Time 6–8 hours (under full sunlight) g) Control Type Infrared Remote Control h) Mounting Pole Mount i) Ingress Protection IP65 j) Rated – Water & Dust Resistant k) Material Die-cast Aluminum Body l) Operating Temperature -10°C to 50°C m) Warranty 1 Year ( from the date of SITC) | - | set | 15,310.32 | - |
| 1.002 | OD350754/2025-2026:Supply and installation of BIS CERTIFIED 1000VA/24 VDC line interactive UPS with 2 nos of 7Ah SMF Battery inbuilt Single Phase Input Single Phase output and Earth, Input power factor –0 .9, Input current Distortion – I-THD-<=5%, , Nominal output voltage – 230 V AC Single phase, Output voltage regulation- +/-1%, efficiency - >90%, Ventilation – Forced – Air cooled, for –Mains on, Inverter on, Battery Low, Over Load, Trip, Common Alarm, - Battery low Pre-alarm, Trip, Output short circuit protection, Output over/under voltage, Battery over temperature alarm, Battery 12V/7Ah CPRI CERTIFIED SMF 2No. Mandatory CERTIFICATION - ISO9001-2015, ISO14001 -2015, OHSAS 18001: 2007, CE Certification AND BIS Certification, CPRI Certification for batteries. Warranty –Inverter and Battery – 3 years Onsite Replacement Make : Numeric, Hykon, V-Guard, Exide, Amron or equivalent | - | each | 12,198.31 | - |
| 1.003 | OD350755/2025-2026:Supply and installation testing and Commissioning of of suitable size of 150 Ah Tubular battery with interconnection cable with socket(make Exide EL150 or Equivalent) | - | each | 15,645.5 | - |
| 1.004 | OD350756/2025-2026:Supply Installation testing and commissioning of 5KVA/96VDC Pure Sine Wave Offline UPS The OFFLINE UPS shall have the following specifications. 1) INPUT a) Nominal Voltage - 220VAC/230VAC b) Operating Voltage Range - 160 ~ 280 VAC c) Operating Frequency Range- 45~55 Hz d) Power Factor - 0.99 e) THDi (Current harmonics) - <2% for linear load, <5% for non-linear loads f) RECTIFIER - advanced DSP technology a) Output Voltage - 220 Vac / 230 Vac ± 1% b) AC Volt. Reg. (Batt. Mode) - ± 1% c) Frequency Range - 50 Hz ± 1% d) Crest Factor - 3 : 1 (max) e) THDv (Voltage harmonics) - <2% for linear load, <5% for non-linear loads f) Overload - 125% for 1min and 150% for 200ms g) Transfer Time - 4-8 milli sec for Mains to Battery h) Out put Power Factor - > 0.85 i) a) Overall 90%~92% 4) BATTERY a) Battery Voltage - 96V DC b) Charging Current (max) - 5-15A 5) DISPLAY - Input Voltage, Output Voltage, Load current, Output Frequency, Battery Voltage, UPS Status 6) INDICATIONS - Load On Mains, Load on Battery, Battery Low, Overload, UPS Fault 7) ALARM - Input / Low / Fail, Output Overload, Over Temperature, Battery low 8) ENVIRONMENT a) Temperature - 0° C to 40° C b) Operational Humidity - 0 to 95% c) Noise Level - < 60dB (1m from the surface level) 9) CERTIFICATIONS - Comply with Relevant BIS/IS standards 11) Warranty - 3 years from SITC. 12) Make - Exide/Hykon/NUMERIC/or its equivalent | - | set | 39,753.97 | - |
| 1.005 | OD351016/2025-2026: Supply and providing name board on 16/20 mm thick granite slab with inscriptions as directed, Fixing it on foundation with required materials etc as required. | - | each | 1,974.55 | - |
| 1.006 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | - | metre | 237.1 | - |
| 1.007 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | - | metre | 147.76 | - |
| 1.008 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | - | each | 674.38 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_1463228.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_1463228.xls
BOQ • 0.31 MB
SBD.pdf
Tender Documents • 3.31 MB
NIT.pdf
Tender Documents • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .