Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹34.9 L+₹1.7 L (5.26%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹34.9 L+₹1.8 L (5.40%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹35.8 L+₹2.7 L (8.18%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹36.4 L+₹3.3 L (10.0%)Rejected-Finance NEAR OLD POST OFFICE SUJANPUR TEH DISTT PATHANKOT PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
24 Aug 2023, 6:00 pmClosed
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
GER-28/2023-24 Provn of 01 x 320 KVA Generator Set and AMF Panel for Generator Set and Special repair to UG cables and connected items at Rajouri of AGE E/M under GE 862 EWS
2023_MES_610352_1
GER-28/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Class D b(i)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹79,000
Yes
9 Sept 2023
24 Jul 2023
26 Aug 2023
24 Jul 2023
24 Aug 2023
10 Aug 2023
Amount
Supply, installation, testing and commissioning complete of OEM manufactured, static silent (sound proof enclosure) diesel Engine Driven generating set capable of delivering 320 KVA, Water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. Engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears.The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardised by manufacturer, fuel tank with mounting arrangements and inlet, outlet, return and inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Rajouri (J&K) (capacity of Engine, alternators shall be worked out taking all derating factors into consideration), with all provisions to operate through AMF panel & including PCC foundation of suitable size leaving at least 0.5 M all around for easy of movement and 0.5 M height, anti vibration pads, including all features to complete with latest CPCB guidelines and comprising of following :- (i) ENGINE (Prime Mover) : Diesel Engine 8 cylinders 1500 RPM, direct injection type , confirming to ISO 3046 / BS 5514, Water cooled, naturally turbo charged, capable of giving adequate@ 400 BHP to drive alternator capable of delivering 320 KVA at outdoor atmospheric conditions at Rajouri (J&K), ( Taking all derating factor into consideration), Dry cell battery ( Make: Exide / Amaron / HBL ) to be provided as per manufacturer recommendations with suitable battery charger, electric battery start, complete with flywheel all standard fittings / fixtures as per manufacturer and including suitable panel with tachometer, lube oil, temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic speed governor (ECPG) and engine protection system (shut down, High water temperature, low lube oil, oil pressure, over speed etc) fuel tank, emergency stop button and first fill of lube oil and other consumables including Diesel for commisioning test etc.
(ii) ACCOUSTIC ENCLOSURE :- Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75% load under field condition. (iii) Foundation / Plinth / Base : Shall be provided as per manufactures recommendations, however minimum 0.5 M space should be available all around the set and height of plinth shall not be less than 0.5 M above ground level. (iv) Diesel storage tank of adequate capacity for storage of diesel for 12 hrs operation of Gen Set. (v) MISC : Tool kit, operation and maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer's standard practices. (vi) ALTERNATOR : Brushless AC alternator, 3 phase, 415 volt, 4 wire, self excited, self regulated with fast response rated for output of 320 KVA, Minimum power factor 0.8, 1500 RPM, IP 65 protection class enclosure, insulation class “H” salient pole, revolving field single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine between ± 1% of Sets volts from no load to full load.
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 300 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for foundation, etc, or for laying of cables, n.exc 10 Sqm on plan and getting out, complete all as specified and directed.
Returning, filling in, any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid in trenches flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
M&L for 40mm bore galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including 32X6mm thick galvanised iron strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mm c/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion, complete all as specified and directed. (Note:-Earth strip and protection pipe upto test point is included in the rate quoted)
S&F for change over switch, 4 pole, 415 Volts of rating 400 Amps, front handle operated type, on load type in sheet metal enclouser of 2mm thick CRCA sheet, powder coated weather proof fixed on wall complete including connected to incoming and outgoing cables with suitable lugs, glands, nuts, bolts, and washers etc, complete all as specified and directed.
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
S&F in replacement for change over switch, 4 pole, 415 Volts of rating 63Amps, front handle operated type, on load type in sheet metal enclouser of 2mm thick CRCA sheet, powder coated wheather proof fixed on wall including all fixing arrangement and connected to incoming and outgoing cables with suitable lugs, glands, nuts, bolts, and washers etc, complete all as specified and directed.
S&F for LED secutity light fitting 35 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall / pole at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type, complete all as specified and directed
S&F for FRP looping box of size 325x220x150 mm with aluminium bus bar (02 Nos) 100 Amps capacity connector and comprising oF MCB SP 6 Amps, ISI marked 240 V, 'C' series/curves complete with including providing GI calmps, nuts bolts etc suitable for fixing on PCC pole/wall etc and after taking down old unserviceable looping box of any type complete all as specified and directed.
M&L for GI bracket pipe of size 40mm bore medium grade of 1.2 mtr long bent to shape hot or cold suitable for nil street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clamps 2 Nos of suitable length, duly fixed to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts and washers and after taking down old unserviceable GI brakcet of any type complete all as specified and directed.
S&F for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 3 core 1.5 sqmm and including connection and testing and after taking down old unserviceable copper conductor cable, complete all as specified and directed.
S&F for decorative LED Bollard light with cone shaped integral decorative with polycarbonate diffuser type LED Bollard light 9W, IP 65 lihgt including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC 1:2:4 fixed on wall/floor and making electrical connection with copper cable, after taking down old unserviceable light fittings of any type, complete all as specified and directed.
S&F in repair for post top lantern light fitting 35 watts with cast aluminium spigot lid cover and clear acrylic cover with IP65 protection complete with all accessories including fixing arrangement by providing GI pipe of suitable size and length as per site requirement and making good the distrubed portion to match with existing surface, after taking down old unserviceable light fittings of any type, complete all as specified and directed.
S&F bus bar chamber panel out door type 3.15mm of suitable size with 4 strips 200 Amp bus bar aluminium along with MCCB of 125 Amp four pole adjustable type duly connected to aluminium strip at incoming side with suitable space for 2 incoming cables and outgoing of 2 cables, bus bar fixed on insulators in zig-zag position, clearance in each strip and clearance at both side should not be less than 125mm with sufficient working space, height of bus abr chamber not less than 1 mtr, mounted MS angle 50x6mm, made of CRCA sheet 2mm thick outdoor type powder coated both side opening shutter in two halves cable opening from bottom side with indicators RYB hinges through out the length of shutter with half turn locking arrangement, including grouting in PCC, after taking down old unserviceable bus bar chamber panel of any type, complete all as specified and directed. Note: Bus bar chamber panel of size 600x900x350mm.
M&L in repair for 50mm bore galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
HUSSAIN ENTERPRISES
M/s Kay Aar Enterprises
M/S PARSHOTAM KUMAR GUPTA
M/S SURINDER KUMAR MAHAJAN
FANGALIA TRADERS
HARPAL ENGINEERS AND BUILDERS
Vijaypower Generators Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .