Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAdmitted-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L1 | Admitted-Finance | |
| 2 | L2₹29.5 L+₹44,137 (1.52%)Admitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Admitted-Finance | |
| 3 | L3₹29.5 L+₹49,709 (1.71%)Admitted-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L3 | Admitted-Finance | |
| 4 | L4₹32.4 L+₹3.4 L (11.5%)Admitted-Finance | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AISWARYA ENTERPRISES L4 | Shree Ayyappa Engineering L2 | Glacier Cooling Solutions Private Limited L3 | ELAN ENGINEERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Supply, installation, testing and commissioning of Air cooled Floor mounted packaged type Inverter AC of under mentioned capacity of energy efficient with inverter type, hard drawn copper refrigerent piping between indoor and out door units, control cabling between indoor & out door units, provide rigid PVC drain piping 25 mm dia up to nearest drain point, package AC should comprising of hermetically sealed scroll compressor, cooling coil internally grooved copper tubing with aluminium fins, fans, motor, safety devices, hydrophilic coated suitable to work till 50°C ambient, including grouted on ribbed rubber pads as vibration insulators alongwith all standard fittings, HP/LP cutout, single phase preventer, OLR suitable for operational on three phase AC electric supply, including required foundation for base, MS frame stand for outdoor unit of Package Unit including fabrication work and installation work complete all as per OEM recommendation with making up good existing walls/floors/ceiling with existing finishes fixed on cable tray complete all as specified and as directed by Engineer-in-charge. Note: (i) Cable tray of suitable size deems to be inclusive of the rate quoted above (ii) Items such as charging of gas, refrigerant piping, control cabling, draining piping used shall deemed to be measured and paid seperately under relevant items. (iii) Contractor shall procure warrantee for the period of one year at the time of final bill. | |||||||
| 1.01 | 11TR Fixed speed Package unit complete all as specified and as directed | 1 | Each | 3,45,000 ₹3,45,000 | 4,18,000 ₹4,18,000 | 3,87,059 ₹3,87,059 | 3,30,000 ₹3,30,000 Lowest |
| 1.02 | 23TR Fixed speed Package unit complete all as specified and as directed | 1 | Each | 6,80,000 ₹6,80,000 | 8,35,900 ₹8,35,900 | 6,38,000 ₹6,38,000 Lowest | 6,54,000 ₹6,54,000 |
| 2.00 | Material and laying of refrigerant piping (suction & discharge) hard drawn from hard copper tube of suitable sizes as recommended by OEM, with copper elbows, tees all connecting material with insulation for suction line unit connections complete all as specified and as directed by Engineer-in-charge.
Note: One run of both suction & discharge pipe line along with insulation shall be measured as one length. | 30 | RM | 3,000 ₹90,000 | 2,300 ₹69,000 Lowest | 2,600 ₹78,000 | 2,700 ₹81,000 |
| 3.00 | Supply and fill of refrigerant 410A gas as specified and as directed by Eng-in-charge. | 35 | Kg | 1,500 ₹52,500 | 1,200 ₹42,000 | 1,050 ₹36,750 Lowest | 1,700 ₹59,500 |
| 4.00 | Supply, Installation of control cabling between indoor unit and outdoor unit complete all as specified and as directed by Engineer-in-charge. | 35 | RM | 300 ₹10,500 | 700 ₹24,500 | 650 ₹22,750 | 270 ₹9,450 Lowest |
| 5.00 | Supply and laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors,1100 volts grade of size 70 qmm 3.5 core complete all as specified and as directed.
Note : For Ser No 5 The rates quouted deems to inclusive of cutting of road /removal of interlocking tiles for laying of cables and refixing/repairing the same after laying of cables, matching with the existing ground level complete all as specified. Any damage caused to the interlocking tiles shall be replaced without any extra cost. | 200 | RM | 500 ₹1,00,000 Lowest | 700 ₹1,40,000 | 800 ₹1,60,000 | 750 ₹1,50,000 |
| 6.00Supply, fabrication, installation and testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. as required. | |||||||
| 6.01 | 0.63 mm (24 Gauge) complete all as specified and as directed | 120 | Sqm | 1,800 ₹2,16,000 | 1,200 ₹1,44,000 | 1,150 ₹1,38,000 Lowest | 1,750 ₹2,10,000 |
| 6.02 | 0.80 mm (22 Gauge) complete all as specified and as directed | 45 | Sqm | 2,200 ₹99,000 | 1,400 ₹63,000 | 1,250 ₹56,250 Lowest | 2,050 ₹92,250 |
Tender Value
₹28.9 L
EMD Value
₹57,860
Closing Date
7 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
PROVISION OF PACKAGE TYPE AIR CONDITIONING AT BUILDING No P-196 AND P-197 (900 MEN JUNIOR SAILORS DINING HALL) AT INS GARUDA,KOCHI
2026_MES_788569_1
8721/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
KOCHI
As per Tender documents
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹57,860
Yes
9 Oct 2026
9 Sept 2026
9 Oct 2026
9 Sept 2026
7 Oct 2026
24 Sept 2026
9 Sept 2026 - 10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, installation, testing and commissioning of Air cooled Floor mounted packaged type Inverter AC of under mentioned capacity of energy efficient with inverter type, hard drawn copper refridgerent piping between indoor and out door units, control cabling between indoor & out door units, provide rigid PVC drain piping 25 mm dia up to nearest drain point, package AC should comprising of hermetically sealed scroll compressor, cooling coil internally grooved copper tubing with aluminium fins, fans, motor, safety devices, hydrophilic coated suitable to work till 50°C ambient, including grouted on ribbed rubber pads as vibration insulators alongwith all standard fittings, HP/LP cutout, single phase preventer, OLR suitable for operational on three phase AC electric supply, including required foundation for base, MS frame stand for outdoor unit of Package Unit including fabrication work and installation work complete all as per OEM recommendation with making up good existing walls/floors/ceiling with existing finishes fixed on cable tray complete all as specified and as directed by Engineer-in-charge. Note: (i) Cable tray of suitable size deems to be inclusive of the rate quoted above (ii) Items such as charging of gas, refrigerant piping, control cabling, draining piping used shall deemed to be measured and paid seperately under relevant items. | |||||
| 1.01 | 11TR Fixed sped Package unit complete all as specified and as directed | 1 | Each | - | - |
| 1.02 | 23TR Fixed sped Package unit complete all as specified and as directed | 1 | Each | - | - |
| 2 | Material and laying of refrigerant piping (suction & discharge) hard drawn from hard copper tube of suitable sizes as recommended by OEM, with copper elbows, tees all connecting material with insulation for suction line unit connections complete all as specified and as directed by Engineer-in-charge.
Note: One run of both suction & discharge pipe line along with insulation shall be measured as one length. | 30 | RM | - | - |
| 3 | Suplly and fill of refrigerant 410A gas as specified and as directed by Eng-in-charge. | 35 | Kg | - | - |
| 4 | Supply, Installation of control cabling between indoor unit and outdoor unit complete all as specified and as directed by Engineer-in-charge. | 35 | RM | - | - |
| 5 | Supply and laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium onductors,1100 volts grade of size 70 qmm 3.5 core complete all as specified and as directed.
Note : For Ser No 5 The rates quouted deems to inclusive of cutting of road /removal of interlocking tiles for laying of cables and refixing/repairing the same after laying of cables, machiching with the existing ground level complete all as specided. Any damage caused to the interlocking tiles shall be replaced without any extra cost. | 200 | RM | - | - |
| 6Supply, fabrication, installation and testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. as required. | |||||
| 6.01 | 0.63 mm (24 Gauge) complete all as specified and as directed | 120 | Sqm | - | - |
| 6.02 | 0.80 mm (22 Guage) complete all as specified and as directed | 45 | Sqm | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
PS8721.pdf
Tender Documents • 0.57 MB
COMMONPAGES8721.pdf
Tender Documents • 0.51 MB
BOQ_883913.xls
BOQ • 2.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .