HQ CWE AF BHISIANA
REPAIR/MAINTENANCE OF HT TRANSFORMER, VCB, RMU AND ALLIED WORKS AT DOMESTIC AREA AT AF STATION HALWARA UNDER GE (AF) HALWARA
2026_MES_796463_1
CWE(BHI)/HAL-92/2026-27
Open Tender
Civil Works
Works
180 days
HALWARA
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF HALWARA
₹30,000
Yes
30 Oct 2026
30 Oct 2026
20 Nov 2026
30 Oct 2026
18 Nov 2026
13 Nov 2026
30 Oct 2026 - 6 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting of HT and DC connections from existing bus bar, disconnecting trolley including servicing of complete parts of VCB 11 KV any type any make at site, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete Relays etc including checking parts, repair to control wring with single core conductor of existing size as required at site for VCB of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts, re-assembling the same, re-connecting all HT & AC / DC connections to make it functional including testing on existing load complete all as specified and as directed by Engr-in-charge. | 2 | Each Job | - | - |
| 2 | Supply and fixing in replacement of closing coil 24 V, DC for 11 KV VCB trolly of make & specifications as existing at site as per latest standards after taking down coil complete all as specified and as directed by Engr-in-charge. | 1 | Each | - | - |
| 3 | Supply and fixing in replacement of shunt tripping coil 24 V, DC for 11 KV VCB trolly of make & specifications as existing at site after taking down coil complete all as specified and as directed by Engr-in-charge. | 1 | Each | - | - |
| 4 | Supply and fixing in replacement of Aegis Relay Low setting & High setting for 11 KV VCB after taking down coil as existing at site complete all as specified and as directed by Engr-in-charge. | 1 | Each | - | - |
| 5 | Supply and fixing in repair male fixed contact for 11 KV VCB after taking down coil complete all as specified and as directed by Engr-in-charge. | 2 | set of 6 Nos | - | - |
| 6 | Supply and fixing in repair Epoxy Spout Bushings for 11 KV VCB after taking down coil complete all as specified and as directed by Engr-in-charge. | 1 | Set of 6 Nos | - | - |
| 7 | Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 3 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 3 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections reconnecting/replacing all the ABB boot from the cable & reconnecting with the terminal after installing new boot on the cable terminal. Cost of boots deemed to be included in the quoted prices.to make it functional including tesing on existing load complete all as specified and as directed by Engr-in-charge. | 7 | Each Job | - | - |
| 8 | Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 4 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 4 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections reconnecting/replacing all the ABB boot from the cable & reconnecting with the terminal after installing new boot on the cable terminal. Cost of boots deemed to be included in the quoted prices to make it functional including tesing on existing load complete all as specified and as directed by Engr-in-charge. | 2 | Each Job | - | - |
| 9 | Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 5 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 5 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections reconnecting/replacing all the ABB boot from the cable & reconnecting with the terminal after installing new boot on the cable terminal. Cost of boots deemed to be included in the quoted prices to make it functional including tesing on existing load complete all as specified and as directed by Engr-in-charge. | 2 | Each Job | - | - |
| 10 | Supply and fixing Control Wiring with 1.5 sqmm FRLS copper conductor for control circuits and 2.5 sqmm FRLS copper conductor for CT circuits as per existing diagram including providing cable ties, beading etc of VCB or RMU after taking out old wiring complete all as specified and as directed by Engr-in-charge. | 1 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
Tender92.pdf
Tender Documents • 1.12 MB
BOQ_893338.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .