Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance DOOR NO 2 31 23 SECTOR 7 SBI COLONY MVP VISAKHAPATNAM 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | Admitted-Finance |
Tender Value
₹44.4 L
EMD Value
₹88,720
Closing Date
6 Sept 2024, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
DAY TO DAY MAINTENANCE, ATTENDING BREAKDOWN AND CALL ON REPAIRS FOR 24 HRS FOR SECURITY LIGHT, HIGH MAST LIGHT, TOWER LIGHT AND AREA LIGHT, REPLACEMENT OF UNSV CABLES, SECURITY LIGHTS, FLOOD LIGHTS, HIGH BAY LIGHT AND ALLIED WORKS AT EOC JETTY UNDER
2024_MES_667821_1
8097/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM, Visakhapatnam
₹88,720
Yes
10 Sept 2024
25 Jul 2024
9 Sept 2024
25 Jul 2024
6 Sept 2024
8 Aug 2024
Amount
Supply and fixing HDPE double wall pipe corugated pipe of size 40 mm dia for cable protection laid in trenches in lieu of sand/brick protection complete all as specified and directed.
Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 6 Sqmm 3 core and connection complete with aluminium cable lugs including dismantling taking down unsv one all as specified and directed.
All as per item No. 2.00 above, but of Size 16 Sqmm 4 core
All as per item No. 2.00 above, but of Size 35 Sqmm 3.5 core
S/F MS cross arm, bracings, supports, clamps, nuts, bolts and washers on Pole including painting with one primer coat, one under coat and one finishing coat of aluminium paint incl dismantling taking down unserviceable one all as specified and directed.
Attending electrical complaints and 24 hr call on repair of control panel of street light, security light, garden light, perimeter light, tower light & high mast light provided inside EOC jetty, decarbonizing all contact points of contactors , replacement of wornout aluminium cable lugs, wornout screws, nuts, bolts and washers, tightening the loose connections whereever required, adjustment of timer, cleaning and restore the power supply all as specified and directed. Note : (i) Work to be measured as unit specified. Contractor shall not claim for outsourcing. Work is to be carried out till rectification. Any material as in this schedule shall be measured as applicable. Required screws, saddles, nuts, bolts, insulation tapes shall be provided by the contractor. Complaint shall be rectified within 2 hours else recovery shall be made double the quoted rate.
Note (ii) : (a) Replacement of spares viz MCB, MCCB, contactors, timers, cables, will be measured and paid for separately as supply only and labour element for taking down the replaced spares shall be deemed to include in the unit rate quoted. (b) If the qty of complaints to be attended in a control panel/LT panel is more than 01 No in a day, altogether the complaints will be considered only 1 (one). (c) The contractor has to engage minimum 01 nos electrician and 01 nos helper to attend and rectify the defects. (d) The contractor or his representative must take a round of entire site and check for any defect after 6PM everyday and should rectify any defect immediatly
M&L for dismatling and taking out street light cable loop near pole for size of cable 6 sqmm to 25 sqmm after dismantling connection from junction box, cutting, removing damaged portion of the cable ends, providing new aluminium cable end terminals, laying of cable through protection pipe through coping to junction box including necessary connection complete all as specified and directed.
M&L for dismantling taking out cables 10 sqmm to 25 sqmm from trench, including making straight through joints at damaged portion and relaying to trench complete all as specified and directed.
M&L for dismantling of non - functional street light/flood light from any type of pole at height upto 9 mtr by suitable ladder for repair of the same for replacement unserviceable items like LED driver, connector block and decarbonising contact points and refixing the same to pole after repair of any type security/Street light . Note: Required LED driver shall be measured and paid separately
Supply and fixing PVC insulated, PVC round sheathed submersible copper flexible electric cable 1.5 sqmm 3 core, 1100 Volts grade and dismantling wornout/defective cables all as specified and as directed.
Supply and fixing PVC insulated, PVC round shethed copper flexible electric cable 2.5 sqmm 3 core, 1100 Volts grade and dismantling wornout/defective cables all as specified and as directed.
M&L for complete servicing, repair, maintenance of timer panel, by cleaning inside and outside, replacement of burnt MCB, MCCB, Timer, contactor, wiring, bypass toggle switch complete all as specified and directed. Note: Replacement of MCB, MCCB, Timer, contactor shall be measured as supply only
Supply only power contactor 3 phase, 415V, 63 amps cap utilsed for heavy duty by taking down the old perished / deteriorated contactor all as specified and directed. Make: Schneider, Model-ETVS-LC1E6301 or equivalent of Legrand/L&T/ABB
Supply only surface mounting Analog time switches heavy duty of 230 V 50Hz including dismantling taking down unsv one and all as specified and directed Make : 6499 15 Maxi Rex 4QT (daily) of Legrand or equivelent of ABB/L&T
Supply only MCB, SP, 10KA, 'C' 6-32 A including dismantling taking down unserviceabl one complete all as specified and directed. Make:- Schneider or equivelent of Legrand/ABB /L&T
Supply only MCB, DP, 10KA, 'C' 40A-63 A including dismantling taking down unserviceable one complete all as specified and directed. Make:- Schneider or equivelent of Legrand/ABB /L&T
Supply only MCB, 4P, 10KA, 'C' 40A-63 A including dismantling taking down unserviceable one all as specified and directed. Make:- Schneider or equivelent of Legrand/ABB/L&T
Supply only MCCB with thermal magnetic release, 18 KA, 3 pole, 415V, 40A to 100 A complete all as specified and directed. Make:- Schneider , Model- Easy compact CVS 100 BS, LV510950 to 58 or equivelent of Legrand/ABB/L&T
Supply only LED driver suitable for street light fitting 1x 100/120 W , 230V all as specified and directed. Make :- CG/Halvells/Bajaj/Philips/Wipro
Supply only LED driver suitable for street light fitting 1x 150 W , 230V all as specified and directed. Make :- CG/Halvells/Bajaj/Philips/Wipro
Supply only LED driver suitable for street light fitting 1x 200 W , 230V all as speified and directed. Make- CG/halvells/Bajaj/Philips/Wipro
S & F on flood light LED 60 watt including dismantling taking down unserviceable one complete all as specified and directed.
S & F Street light fitting LED 100 watt watt including dismantling taking down unsv one complete all as specified and directed
S & F Street light fitting LED 150 watt watt incl dismantling taking down unsv one complete all as specified and directed
S & F High bay light fitting LED 200 watt watt including dismantling taking down unsv one complete all as specified and directed,
S & F Flood light fitting LED 300 watt watt incl dismantling taking down unsv one complete all as specified and directed,
S & F LED security search light 400 watt incl dismantling taking down unsv one complete all as specified and directed.
S & F Post top lantern 40 watt incl dismantling taking down unsv one complete all as specified and directed
Taking down old unserviceable aviation light fitting and supply & fix new LED aviation light fitting with clamps, nuts, bolts and service connections up to the junction box complete all as specified and directed. Make :- Cat No.BGAV 302 LED of Bajaj or eqiuvalent in philips/CG/ Havells/Wipro.
M&L for painting of steel tubular pole any type / swan neck pole with one coat of aluminium paint after preparation of complete surface including writing pole number with synthetic enamel black paint comlete all as specified and directed.
M&L for white wash to pole coping PCC at alternate 60 days complete all as specified and directed.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 2.65 Mtr long using suitable mechanical drilling rig or mannually (for drilling near the specified location), connected with galvanised steel earthing strip 25x4mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
S&F PVC junction box of outdoor type, weather proof, with provision of hole at bottom for cable entry, hinged door with locking arrangement, of size not less than 200mm (L) x 100mm(B) x 300mm (H) incl taking down unserviceable one, fixed to pole with MS clamp, nuts, bolts and washers complete including complete connection all as specified and directed. Make- Syntex / Hansel
S&F street light bracket made with 40mm bore medium grade MS pipe, bent to shape of total length 1200 mm with 2 pair of MS clamp, nuts bolts washers painted with one coat of red oxide and two coat of aluminium paint incl dismatling taking out unsv one
Supply and fix garden spike and mini flood light 50 Watt luminaires complete with back powder coated pressure die-cast aluminium housing with mounting bracket all as specified and directed. Make :- Cat No BESBL 150 DH PAR 1X50W E-27 Make Bajaj or equivalent to Philips/Havells/CG
Supply and fix 4W Solar integral decorative LED bollard with IP65 protection all as specified and directed Make : Havells Urban Solar Bollard Cat Part no. LHKNAWPFFN6K001 OR equivalent in Crompton/Bajaj/Philips
S&F on wall/pole timer enclosure panel complete with timer Analog time switches heavy duty of 230 V 50Hz, power contactor 3 phase MNX 18 , 415V, 63 amps, 100A MCCB, TPN, 16KA, 'C' with rotary switch with connector for incoming and outgoing cable entry complete all as specified and directed Make :- Indo Asian/Havells
M&L for fixing of 25mm GI pipe of lenth 3.6 meter at the top of truss using arc welding at one end to avoid swinging of rod due to winds and at other end providing a hook to mount highbay light complete all as specified and directed. Note : Highbay light should be firmly fixed to the hook and should swivel by wind speed. Working height is above 60 meter and contractor has to provide safety equipment to each of the worker.
Material and labour for disconnecting the burnt out high mast tower winch motor 3 phase ,415V, 50Hz,1400 RPM, 4 pole, 2HP and rewinding with supper enameled copper wire of same gauge/size of wire including re-fixing the same in its original position testing and commissioning complete all as directed.
Material and labour for servicing of high mast tower control mechanism by greasing and varnishing of electric motor 2 HP, 3 phase 415 volts 50Hz including replacement of unsv plug and socket for trouble free functioning including painting of starter panel with one coat of synthetic enamel paint all as specified and directed.
SAI SREENIVASA ENGINEERING (BID ID -3090310)
B.Veerabhadra Rao (BID ID -3089412)
MSN ENGINEERING WORKS (BID ID -3089333)
VENKATESWARA ENGINEERS AND CONTRACTORS (BID ID -3089605)
M/s SAI GANESH ENGINEERING ENTERPRISES (BID ID -3089534)
ANAND ENTERPRISES AND ENGINEERS (BID ID -3090409)
M/s SS Engineering Enterprises (BID ID -3090290)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .