Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹22.2 L+₹5.1 L (29.8%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in cat (b) (ii) | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in cat (b) (ii) |
Tender Value
₹22.3 L
EMD Value
₹44,540
Closing Date
26 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR
85897 E8 REPAIR AND MAINT OF HT INFRA AND ALLIED WORKS AT AIR FORCE STN MOUNT ABU AND GURUSHIKHAR UNDER AGE EM,GE AIR FORCE NO-2 JODHPUR
2021_MES_491216_2
85897/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Gurushikhar and Mount Abu under GE AF NO 2 Jodhpur
As Per NIT
7 documents required · 7 mandatory
₹500
GE AF NO 2 Jodhpur
₹44,540
Yes
20 May 2022
7 Jan 2022
28 Jan 2022
7 Jan 2022
26 Jan 2022
14 Jan 2022
7 Jan 2022 - 7 Jan 2022
60 days
Amount
Disconnecting and removing from site step down 11KV/440 Volts transformer complete all as specified and directed by Engineer-in-charge.
Disconnecting the transformer by taking out transformer oil for comprehensive maintenance of all parts including winding and terminals , replacement of rubber gasket sheet ,silica gel, cleaning and removing moisture from it taking all the assembly of transformer and removing / repairing the unserviceable parts, reassembling it after repair testing and commissioning the transformer of capacity 250- 400 KVA stepdown type complete all specified and directed .Repair to power distribution to stop the oil leakage by draining out transformer oil complete in moisture proof drum, dismantling the top cover along with conservator tank, Mashalling box, breather etc and replacing the oil seals and reassembling transformer, refilling oil after filtration by high vacuum oil filtration plant & testing complete all as specified and directed by Engineer-in-Charge.
Checking of ACB 1100 Volt cap 630-800 Amps and servicing/maintenance through authorised dealer for rectification of fault, connecting and testing on load complete all as specified and directed by Engineer-in-Charge. Note: Replacement of unserviceable spares shall be included as follows:- (a) Supply and fixing of manual charging handle assy as per existing make and model complete (b) Supply and fixing of trip coil as per existing make and model complete (c) Supply and fixing of close coil as per existing make and model complete
Supply and Filling ISI Marked transformer oil in sealed drum and topping up of transformer oil in transformers after filtration with 50 to 60 KV/min of die-electric strength of oil by high vacuum oil filtration plant complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade following cross sectional area laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe including taking down the existing cable complete all as specified and directed by Engineer-in-Charge. (a) 95 Sqmm 3 core
(b) Ditto all as per item no-7.00 above but 120 Sqmm 3 Core complete all as specified and directed by Engineer-in-Charge.
S&F HT 11KV XLPE straight through joint, heat shrinkable type, suitable for cable size of 95 Sqmm 3 core cable complete all as specified and directed by Engineer-in-Charge.
S&F HT 11KV XLPE straight through joint, heat shrinkable type, suitable for cable size of 120 Sqmm 3 core cable complete all as specified and directed by Engineer-in-Charge.
Cutting out unserviceable/burntout HT joints from cable supplying, jointing and testing outdoor type HT cable end termination heat shrinkable suitable for 3 core 11 KV under ground XLPE insulated cable of size 120 Sqmm complete all as specified and directed by Engineer-in-Charge.
Cutting out unserviceable/burntout HT joints from cable supplying, jointing and testing outdoor type HT cable end termination heat shrinkable suitable for 3 core 11 KV under ground XLPE insulated cable of size from 95 Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F HT brass spindles with porcelain bush of power distribution transformer of capacity 200 KVA to 400 KVA including taking out unserviceable spindle complete all as specified and directed by Engineer-in-Charge.
Supply and filling dehydrating breather with first fill dehydrating agent (silica jel) supply and fix Dehydrating agent (silica jel) of power distribution transformer of capacity 200 KVA to 400 KVA including taking out unserviceable Silica Jel complete all as specified and directed by Engineer-in-Charge.
Disconnecting the GOD of any capacity and make from main power supply afte taking proper shut down and carrying out repairing of unserviceable GOD by taking down, dismantling & removing dust, carbon deposits or any other substance and replacing worn out parts like fixed contactor-03 Nos, moving contactor-03 Nos, reasssembling complete GOD, re installing in position after applying petroleum jelly on moving and fixed contactor complete all as specified and directed by Engineer-in-Charge.
M & L Drop out fuse with fuse links and wire fuse complete of capacity HT 11KV 200 Amps 10(KA) station class complete with fixing clamps, bolts, nuts and washers fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F Lightening arrester of capacity HT 11KV 200 Amps 65(KA) station class complete with fixing clamps, bolts, nuts and washers fixed in repairs complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr deep and not exceeding 1.5m wide and getting out in hard / dense soil for laying of cables complete all as specified and directed by Engineer-in-Charge.
Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in hard / dense soil and making mounts of surplus soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and laying reinforced precast concrete cable cover, class HV type 1 flat size 300mm x 180mm x 40mm complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning using dry river sand for cable cushioning complete all as specified and directed by Engineer-in-Charge. Note:- for the purpose of payment punned thickness will be measured.
S&F of CT ratio coil 600/5 Amps of 230 volts (Set of 3) complete all as specified and directed by Engineer-in-Charge.
S&F RYB 3 phase LED indicator lamps (set of 3) complete all as specified and directed by Engineer-in-Charge.
Supply and laying GI tubing, light grade, 100mm bore as cable protection fixed on walls/ pole / laid in trenches including removal of old unserviceable pipe complete all as specified and directed by Engineer-in-Charge.
Supply only aluiminium lugs of 100 Sqmm to 400 Sqmm size complete all as specified and directed by Engineer-in-Charge.
M&L for detection / locatisation of fault in HT 11 KV UG cable of any size and length, by means of cable fault locator including pinpointing the exact location of fault retrieving the exposing damaged portion carefully for further inspection and repairs complete all as specified and directed by Engineer-in-Charge. Note :- (i) Charge of cable fault equipment carred out by BESCOM/other agencies are deemed to be included in the item rate quoted. (ii) Contractor on demand by dept has to arrange the above equipment without any delay failing which penalty will be levied by the dept.
M&L for preparation of old painted external exposed surfaces of HT panel board of any size and painting one coat of synthetic enamel paint of approved colour and make complete all as specified and directed by Engineer-in-Charge.
S&F of copper thimbles using crimping tool for electrical connections with cable and connectiong with suitable size of nuts / bolts and washers of size 95 to 240 Sqmm LT cable size complete all as specified and directed by Engineer-in-Charge.
Comprehensive maintenance servicing and testing of APFC panel of capacity 90 KVAr -120 KVAr including cheching of Phase cap capacitors in all capacitor banks ,all MCCB's ,duty contactors, ST relay and all connected wiring including refitting of all as specified and directed by Engineer-in- charge. Note :- (a) Spares required for replacement shall be measured and paid separately.
Taking out unserviceable capacitors from the site of any/size complete all as specified and directed by Engineer-in-Charge.
S&F phase cap capacitor of capacity 5 KVAr in APFC panel complete all as specified and directed by Engineer-in-Charge.
S&F phase cap capacitor of capacity 10 KVAr in APFC panel complete all as specified and directed by Engineer-in-Charge.
S&F phase cap capacitor of capacity 12.5 KVAr in APFC panel complete all as specified and directed by Engineer-in-Charge.
S&F phase cap capacitor of capacity 15 KVAr in APFC panel complete all as specified and directed by Engineer-in-Charge.
S&F power factor controller ST relay ,230 Volt suitable for 120 KVAr APFC panel in APFC panel complete all as specified and directed by Engineer-in-Charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .