| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.3 LAccepted-AOC | ₹77.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹77.4 L+₹14,444.15 (0.19%)Rejected-AOC | ₹77.4 L+₹14,444.15 (0.19%) | L2 | Rejected-AOC L2 |
| 3 | L3₹77.5 L+₹21,666.19 (0.28%)Rejected-AOC C O NEPAL DEBNATH SANTINAGAR W NO 3 P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹77.5 L+₹21,666.19 (0.28%) | L3 | Rejected-AOC L3 |
Tender Value
₹77.3 L
EMD Value
₹1.5 L
Closing Date
12 Dec 2019, 4:30 pmClosed
Sri J.M. Basumatary
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Construction of the Proposed Residence for the Chief Executive Member of BTC, Kokrajhar.
2019_BTC_15089_1
71/NIT/InfraDev/BTC/2019-20/23
Open Tender
Civil Works - Building
Item Rate
365 days
BTC
Refer to SBD
6 documents required · 6 mandatory
₹2,400
Principal Secretary, BTC, Kokrajhar
₹1.5 L
Yes
3 May 2020
30 Nov 2019
13 Dec 2019
30 Nov 2019
12 Dec 2019
30 Nov 2019
30 Nov 2019 - 12 Dec 2019
Amount
CIVIL WORKS PLYBOARD SHUTTERING: 3.2.1.8 Staircase with sloping or stepped soffits including risers and stringers but excluding landing.
3.1.3 Providing form-work of 12mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and wall etc. of insitu reinforced concrete worksupto first floor level. (a) Thickness not exceeding 200mm
BRICK WORKS: 4.1.2 Filling sunken floor with jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.
FLOORING: 5.1.2 25mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish(base concrete to be measured and paid separately) to be laid in panels including curing complete as directed.
5.10.3 Providing polished granite tiles of approved quality, size , shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop 1:3(1cement :3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department.) (ii) With White cement.
5.8.2 Kota-stone slab of 18mm thick in riser of steps, skirtings, dado and pillars laid with 10mm thick base of cement plaster 1:3 (1 cement : 3 coarse sand) laid over and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (1) 550mm X 550mm
5.9.2 18mm thick marbel stone tiles in flooring risers and treads of steps, skirting, dado, walls, pillars laid with 10 mm thick base of cement plaster in prop 1:3 (1cement :3 coarse sand) and jointed with grey cement slurry including rubbing and polishing complete with marble tiles of specified quality and shade at all levels. (c ) With 18mm thick marble stone tiles of size 300mm X 300mm (iii) Kumari Marble
5.7.3.1 Providing polished GEMS CONCRETE/ SUNROCK-Hi CTS tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match of tiles complete at all levels as specified and directed. (B) MULTIWYN TILES TILES
CEMENT PLASTERING: 5.1.10 Cement plaster skirting with cement morter in prop 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with apron in plinth wall. (a) 15mm thick
WOOD WORKS: 9.6.1 Providing and fixing 1st class timber moulded architrave of size 50 X 20mm to door and window frames with countersunk wood screw,wooden plugs and applying a coat of wood preservative on unexpected surfaces etc. (b) 1st class local wood (Hollock/Bonsum)
PAINTING: 13.4.7(a) Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on new surface to give an even shade including thoroughly brushing the surface free from morter dropping and other foreign matter and sand papered smooth.
13.2.3(a) Applying one coat of cement primer of approved brand and manufacture on new internal and external wall surface after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.9.5 Finishing wall with water proofing weather coat smooth anti-fungal exterior painting of Ace brand of Asian Paints and of required shade on old/new wall cleaning and clearing the surface etc. including scaffolding complete as directed at all levels. (two cats)
13.6.3(a) Applying priming coat with ready mixed paint, wood primer (pink) over new wood based surface over 100mm in girth/width after and including preparing the surfaces by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
13.6.5(i) (a) Painting two coats surfaces over 100mm in width or girth (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian /Berger paint/ICI paint/J&N paint/Nerolac) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter sand papering and stooping.
13.7.2(a) Applying primary coat with ready mixed "red-lead / red-oxide" primer over new steel and other metal surface up to 100mm in width or girth after preparing the surface by throughly clearing oil, grease, dirt and other foreign matter and secoured with wire brushes, fine steels, wood scrapers and sand paper.
13.7.4(i) (a) Painting two coats surfaces over 100mm in wdith or girth (excluding priming coat) on new steel and other metal surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac paint) to give an even shade including the surfaces of dirt, dust and other foreign matter.
DOOR FITTINGS: 15.3.1 Supplying, fitting, fixing brass fittings of apporved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete. (a) Sliding door, (ii) 250mm X 16mm sliding door bolts.
15.3.1 Supplying, fitting, fixing brass fittings of apporved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete. (b) Tower bolt (iii) 200mm X 10mm tower bolt
15.3.1 Supplying, fitting, fixing brass fittings of apporved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete. (b) Tower bolt (v) 150mm X 10mm tower bolt.
15.3.1 Supplying, fitting, fixing brass fittings of apporved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete. ( C) Door handles (iii) 150mm
15.5.1 Supplying, fitting and fixing drapery rods along with all accessories in doors, windows and other openings complete as specified and directed by the department at all levels. (A) MAC Drapery rod (i) Gold line and silver line.
GLASS FITTINGS 16.1 Providing and fixing clear sheet glass bedded in putty and fixed with /without wooden beadings including necessary cutting of glass to required sized (Payment for wooden beads shall be made separately) (2) Area of glass panes exceeding 0.15 sqm but not exceeding 0.52 sqm. (b) 4.00mm thick
ANTI TERMITE TREATMENT 26.1.1 Pre constraction anti-termite treatment at the bottom of foundation pits and walls on all sides upto a height of 300mm from bottom of the excavation made for column, plinth beam, wall, trenches etc. by applying the emulsion @5(five) liters per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (trical or euivalant) and water. This provides emulsion containing 1% chloropirophose solution (by weight)
26.1.2 Pre construction anti-termite treatment in the back filling in immediate contact with the foundation structure after completion of column wall etc. to a depth of 450mm and width 300mm (When required refill in 200mm thick layers) by applying the emulsion @ 5(five) litres per square meter of the surface area before starting construction work ( supplying of necessary tools and accessories by the contractor) as per the direction of the department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (trical or euivalant) and water, This provides emulsion containing 1% chloropirophose solution (by weight)
26.1.3 Pre constraction anti-termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories bt the contractor) as per the direction of the department complete. A) With aqueous emulsion having concentration 1:19 with chloropirophose solution (trical or equivalent) and water. This provides emulsion containing 1% chloropirophose solution (by weight)
26.1.5 Pre construction anti-termite treatment by applying the soil along the external perimeter of the building after completion of construction to a distance close to the plinth wall as specified and as directed by he deptt. upto a depth of 300mm making rod holes at 150mm c/c upto 300mm below by applying the emulsion @ 4.5 (four point five) litres per running meter ensuring moistening of the soil with the emulsion (Supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution ( tricel or euivalent ) and water. This provides emulsion containing 1 % chloropirophose solution (by weight)
REINFORCEMENT: 18.9.1 Providing, fitting and fixing Godrej SS 304 grade railing with pipes/glass for different staircase, cutous areas, balcony etc. with complete installation, Acrylic finish etc. which is fitted with mid pipes and top pipes of good quality steel. Moreover, depending on the requirement glass panels can also be fittedon specific railings. Good quality screws are provided for fixing up the railings. (a) SS Railing Steel with Wire Locator.
DOOR FRAMES 18.7.1 Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mm X 40mm X 5mm fabricated, welded, mitred and joined as per relevent IS Codes including fitting 8 nos of MS hold fast providing closing/holding device for 2nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed (Door hings to be paid as per relevent item of the schedule of rates)
ROOFING 8.1.41 Providing colour coated DURASHINE (TATA BLUESCOPE) zinc-aluminium profile sheet (Total coated thickness=0.45mm) of nominal 1015mm effective cover width and nominal 28mm deep ribs with subtle square fluting in the five pan at nominal 203mm centre-to-centre including fasteners class 2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately. (A) DURASHINE ROOF PROFILE (0.45mm (TCT) X 1072mm)
8.1.42 Providing colour coated DURASHINE (TATA BLUESCOPE) zinc-aluminium roof, wall and tile profile sheet accessories (Total coated thickness=0.45mm) including fasteners class 2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately. (i) Plain Ridge
9.4.1 Providing barge board of size 200mm X 20mm with 1st class local Hollock/ Bonsum timber/ BISON Board including fitting and fixing with necessary wood screws etc. complete.
WATER PROOFING: 22.3.10 Providing and applying over sunken slab etc., two coats of waterproofing slurry prepared with neat cement, water and modified styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd., by brush after proper surface preparation (Surface preparation including through cleaning of surface to be measured and paid separately) as specified & directed by the Department complete,
ROOF TRUSS: 18.3.1 providing, fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black tubes conforming to relevent I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
FALSE CEILING: 7.2.1 Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which including G.I. Perimeter channels of size 0.55mm thick (having one flang of 20mm and another flang of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm C/C. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffits at 1220mm c/c with ceiling angle of width 25mm X 10mm X 0.55mm thick fixed to soffits wih G.I cleat and steel expansion fasteners. Ceiling section of 0.55 thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermidiate channels with the help of connecting clip and in direction prependicular to the intermediate channel at 457mm c/c, 9.5mm/12.5mm tapered edge Gypboared (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. screws fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally , the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square of the boards with jointing compound , joints paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed .(for light fitings, providing opening for doors, window , ventilators etc, cut out made with frame of perimeter channel supported suitable to be measured and paid separately where necessary) (ii) 12.5mm thick
29.2.1 Supply, Installation, fixing of DRY CHEMICAL POWDER Fire Extinguisher conforming to IS:2171 with ISI mark and CO2 cartridge will be conforming to IS:4947 with ISI mark, Powder will be conforming to IS:4308 with ISI mark (5 KG) BRAND: FIRESTOP/FIREND.FIRE SHILD/GETECH/MINIMEX
29.2.9 Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguisher confirming to IS:2878 with ISI mark (4.5 LITERS) BRAND: FIRSTOP/ FRIEND/ FIRE SHIELD/ GETECH/MINIMEX
Supplying, fabricating, erecting and fixing to R.C.C. structure Mild Steel (MS) tubular frame structural work polyurathene (PU) coated (minimum 2 coats) over a coat of red oxide paint after sand blasting all exposed MS surface including providing MS base plates of minimum 14mm thick, ribs and cleats plates minimum 8mm thick, 304 Stainless Steel (SS) wire minimum 6 mm thick, 304 SS plates minimum 2mm thick, 303 SS turn buckle etc. with all 304 SS accessories as required of ANCON make including providing, earning, fixing, fitting to MS tubular and heat welding wherever required FERRARI Architectural PVC membrance in Ultra Violet Stabilized colour of ANCON make (Yam: 2x1100 Dtex PEX HT), weighing 950 gm/sqm, with Tensile Strength of 55/50 daN, adhesion of 12 daN/5cm, having PVDF finish, Formula S Flourinated Varnish Wieldable heat welded at joints as per approved drawing and as directed and specified of following make. (i) FERRARI 502 Architectural PVC Membrane
Providing, fitting and fixing Glassfibre Reinforced Concrete (GRC) Cornice Profiles of BHUTAN GRC brand to RCC chajjas with anchor bolts as per detail including making good the surface by filling the joints with 1:3 cement sand mortar wherever required as directed and specified. Gun Sprayed GRC Cornice Profile unto approved mould developing ultimate strength of not less than 20 MPa having minimum 1990 KG/M3 dry density. (i) Single band with cornice
Providing, fitting and fixing Glassfibre Reinforced Concrete (GRC) Cornice Profiles of BHUTAN GRC brand to RCC chajjas with anchor bolts as per detail including making good the surface by filling the joints with 1:3 cement sand mortar wherever required as directed and specified. Gun Sprayed GRC Cornice Profile unto approved mould developing ultimate strength of not less than 20 MPa having minimum 1990 KG/M3 dry density. (ii) Double band with cornice
BOUNDARY WALL 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling(return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Upto adepth of 2.00m below the existing G.L. (b) In hard/ dense soil Foundation of RCC column
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete( shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume. 1. Foundation of RCC column
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete( shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume. 2. Under tie beams
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete( shuttering where necessary shall be measured and paid separately ) 2. In coping over columns
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footing, bases of columns, pile cap, raft and mass concrete work etc. (i) Using 38mm thick plank 1. Foundation base of RCC column
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footing, bases of columns, pile cap, raft and mass concrete work etc. (i) Using 38mm thick plank 2. Tie beam sides
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, struts (i) Using 38mm thick plank 1. RCC columns upto tie beam
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, struts (i) Using 38mm thick plank 2. RCC columns above tie beam
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, struts (i) Using 38mm thick plank 3. In coping bottom
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, struts (i) Using 38mm thick plank 4. In coping sides
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA SAIL 1. Foundation base
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA SAIL 2. column
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA SAIL 3. Column stirrups upto soffits of 2nd tie beam
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA SAIL 3. Tie beam main bars
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA SAIL 3. Tie beam stirrups
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3 (1 cement : 1.5 coarse sand: 3 grade stone chips, 20mm down) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick. 1. column base
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3 (1 cement : 1.5 coarse sand: 3 grade stone chips, 20mm down) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick. 2. Column base tapped portion
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3 (1 cement : 1.5 coarse sand: 3 grade stone chips, 20mm down) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick. 3. Column upto tie beam
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3 (1 cement : 1.5 coarse sand: 3 grade stone chips, 20mm down) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick. 4. In tie beam
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3 (1 cement : 1.5 coarse sand: 3 grade stone chips, 20mm down) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (ii) In Supar structure from plinth level upto 1st floor level. (b) Column, pillars, post, struts, suspended floor, roof, landing, shelf and support balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing the top surface and finishing of noising. Columns
6.2.5 20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 1. Sides
6.2.5 20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 2. copping top
6.2.5 20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 3. copping sides
13.2.3(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.9.2 Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats).
10.2 Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with roundheaded bolts and nuts or screws. Ornamental grill Fixed to Brickwork/P.C.C./R.C.C. 1. 12mm square bars.
10.2 Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with roundheaded bolts and nuts or screws. Ornamental grill Fixed to Brickwork/P.C.C./R.C.C. 2. 48 X 96 RHS horizontals
10.2 Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with roundheaded bolts and nuts or screws. Ornamental grill Fixed to Brickwork/P.C.C./R.C.C. 3. 48 X 96 RHS verticals
10.2 Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with roundheaded bolts and nuts or screws. Ornamental grill Fixed to Brickwork/P.C.C./R.C.C. 4. MS 50 X 6 rail
13.7.2 +13.7.4 Painting two coats (including priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac) and brushing to give an even shade including clearing the surface of all dirt, dust and other foreign matter. surface over 100mm in wdith or girth
SANITARY WORKS: 1.1.3 Providing fitting and fixing starwhile vitreous water closet equating pan (Indian type W.C. Orissa pattern) of size 58x44x25 with 100mm SCI 'P' or 'S' trap, 10 litre low level PVC flushing cistern with manually controlled device (handle over) (Sleek Plus Single Flush) of Hindware make with all fittings and fixture complete including cutting and making good the walls and floors wherever required. (Cat. No. 20076).
1.3 Providing, fitting and fixing starwhite vitreous china wall mounted type KYLIS water closet (European type W.C. pan 380x370x550) of Hindware make with starwhite CONSTELLATION slow falling PVC seat with cover of HINDWARE make including all accessories provided for by the manufacturer including painting of fittings and brackets, cutting and makin g good the walls wherever required with P Trap. (Cat. No. 92080).
1.6 Supplying fitting and fixing concealedcistern with all internal fitting wit CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. complete as directed and specified (pipes will be paid separately). Concealed cistern (Cat No. CIB-WHT-3101011 X) with cntrol plate (CP) (Cat. No. CIS0CHR-31191510X0.
1.7(v) Providing, fitting and fixing starwhite vitreous china flat back back type lipped front urinal basin of size 610 x 390 x 370 of Hindware make with CI/MS brackets etc complete, with photo volltaic sensor automatic flushing with all accessories as provided for by the manufacturer including painting of fittings and brackets, cutting and making good to the walls and floors wherever required. (SENSO ART-60018).
1.13(B) Providing vitreous china STUDIO wash basin of size 570 x 480 of Hindware make with semi pedestal including CI/MS brackets, 32 mm CP brass waste coupling of standard pattern, CP stop cock, CP brass chain with plug, PVC waste pipe with all accessories as provided for by the manufacturer including painting of fitting and brackets, cutting and making good to the damage of the floors and (a) Starwhite vitreous china wash basin of size 570 x 480 mm (Cat No. 10096 & 11038)
Counter Top Basin (B)(ii) Hindware make (Optra 570 x 440 (cat. No. 91008).
Wall Hang Basin (a) White vitreous ,china wash basin of size 45x30 mm (Cat No. 10004)
Providing fitting and fixing stainless steel Kitchen sink of Agmeco make with coupling and strainer of same make, C.I. brackets, PVC waste pipe including painting of fittings, cutting amd making good the walls and slabs wherever required. (B) Single Bowl with single drain board. viii Bowel size of 355x355x180mm.
Providing, fitting and fixing mirror with plastic frame of size 500 x 400 mm complete as directed and specified.
Providing, fitting and fixing recessed soap tray/ soap dish complete as directed and specified.
Providing, fitting and fixing Liquid soap Dispenser and Liquid Soap Container of Agmeco make complete as specified and directed.
Supplying, fitting and fixing chrome plated C.P. Towel rail of Sona make complete as specified and directed.
Supplying, fitting and fixing chrome plated C.P. Towel rack of Sona make complete as specified and directed.
Supplying fitting and fixing chrome plated C.P. Towel ring of Agmeco make complete as specified and directed.
Supplying, fitting and fixing chrome plated C.P. robe hook of Agmeco make complete as specified and directed.
Supplying, fitting and fixing Brass tumbler Holder of Agmeco make complete as specified and directed.
Supplying, fitting and fixing C.P. bottle trap Economy model of Sona make complete as specified and directed. 32mm with 190mm long wall connection pipe.
Supplying, fitting and fixing PVC pipes of 6 Kg/sqcm (Supreme/Prince) ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) ln exposed surfaces or in trenches. (ii) 110mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of Supreme/Prince make including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed . a) ln exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing 45 degree PVC bend of Supreme/prince make including joining, fitting and fixing etc. as necessary complete at all levels including below G.l - as directed. a) ln exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of Supreme/ Prince make including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed. a) ln exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of Supreme/Prince make including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed. a) ln exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fitting and fixing PVC coupler of Supreme/Prince make including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed. A) in exposed surfaces or in tenches. (i) 110mm dia.
Providing fitting and fixing 110 mm dia PVC cowel of ISI make complete as directed and specified.
Providing fitting and fixing CP grating to the floor complete as directed and specified with PVC floor trap. (b) 100mm dia.
Providing fitting and fixing 450 mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg weight complete as directed and specified.
Construction of inspection pit inside measurement 450mm X 450mm X 450mm flush with 100/160 dia PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 115cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side walls and floor finished with a floating coat of neat cement, 450mm X 450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pits as directed.
Construction of filter bed in soak pit including earthwork in excavation of soil and then filling up of the trench with brick bats/ charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (Size of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.)
Providing brick masonry septic tank of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc. are provided at suitable points complete as directed. 10
Excavation of 300 wide and 450 deep trench to lay 110 dia. PVC pipes including flat brick soling, laying of pipe, covering pipe by laying 200 thick 1:3:6 PCC over soling and PVC pipe by providing shuttering on both side and back filling earth complete as directed.
WATER SUPPLY WORKS: 3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0 M spacing. This including joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. I. In exposed surfaces or in trenches. e. 40mm dia
3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0 M spacing. This including joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. I. In exposed surfaces or in trenches. f. 50mm dia.
3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0 M spacing. This including joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. II. Concealed by chiselling or breaking brick wall/C.C./ RCC and making good the damages. f. 15mm dia.
3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0 M spacing. This including joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. II. Concealed by chiselling or breaking brick wall/C.C./ RCC and making good the damages. e. 20mm dia
3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0 M spacing. This including joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. II. Concealed by chiselling or breaking brick wall/C.C./ RCC and making good the damages. d. 25mm dia.
3.2.1(IV)(V) Supplying fitting and fixing C.P. two way bib cock with flange as directed and specified.
3.2.1(IV)(iv) Supplying fitting and fixing C.P. long body bib cock with flange of Agmeco make as directed and specified.
3.3.2 Supplying fitting and fixing C.P. stop cock of as directed and specified. b(i) Angle cock (Cat No. F110004)
3.3.2 Supplying fitting and fixing C.P. stop cock of as directed and specified. b(ii) Concealed stop cock 15mm (Cat No. F110005)
3.9.1(I)(i) Supplying and fitting fixing C.P. central hole basin mixer as directed and specified.
3.9.1(III)(a) Supplying and fitting fixing C.P. pillar cock of Hinware (IMMACULA) make as directed and specified (Cat No. F110001)
3.6.1(ii)(a) Supplying and fitting and fixing C.P. sink cock of hindware (IMMACULA) brand as specified and directed (Cat. No. F110021)
3.8.2(III) Supplying fitting and fixing chrome plated (C.P.) over head shower.
3.8.2(V) Supplying fitting and fixing chrome plasted (C.P.) heavy casted arm
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) ISI make as specified and directed. (a) 50mm dia.
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) ISI make as specified and directed. (b) 40mm dia.
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) ISI make as specified and directed. (c ) 25mm dia.
5.4.2 Supplying and placing plastic cylindrical vertical closed top (PCVC) tank sintex/ polycon/ patton make over the staging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes complete as directed. (A) 2000 litre capacity (i) Sintex make
A. SCHEDULE ITEMS: ELECTRICAL WORKS: 3.11 Wiring for light point/fan point/call bell point with 1.5 sq. mm insulated (ISI maked) HFFR Copper Conductor cable in recessed P.V.C conduit, 2.0mm thick of required size with ceiling rose, without switch and switch board as directed by the deptt. 1.1 Short Point up to 3.00 mtr. Length.
3.11 Wiring for light point/fan point/call bell point with 1.5 sq. mm insulated (ISI maked) HFFR Copper Conductor cable in recessed P.V.C conduit, 2.0mm thick of required size with ceiling rose, without switch and switch board as directed by the deptt. 1.2 Medium Point up to 6.00 mtr. Length.
3.11 Wiring for light point/fan point/call bell point with 1.5 sq. mm insulated (ISI maked) HFFR Copper Conductor cable in recessed P.V.C conduit, 2.0mm thick of required size with ceiling rose, without switch and switch board as directed by the deptt. 1.3 Long point up to 10.00 mtr Length
8.24 Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete as per direction of department.
8.26 Supplying including installation of socket outlet 6 Amps 3 pin combine complete as per
8.9 Supplying with fitting fixing 16 amp one way modular clip in switch in recessed system with lector/indicator including making necessary connection complete as per direction
8.2 Supplying with fitting fixing 6 amp one way modular clip in switch in recessed system including making necessary connection complete as per directed of department.
8.23 Supplying with fitting fixing 6 amp one way modular clip in bell push in recessed system including making necessary connection as per direction of department.
8.1.1 Supplying with fitting and fixing 120watt electronic modular fan speed controller including making necessary connection as per direction of department.
8.34 Supplying including and fixing of metal boxes in recessed system complete as per direction (a) 1-3 module flush type
8.34 Supplying including and fixing of metal boxes in recessed system complete as per direction (b) 4-5 module flush type
8.34 Supplying including and fixing of metal boxes in recessed system complete as per direction (c ) 6-8 module flush type
8.34 Supplying including and fixing of metal boxes in recessed system complete as per direction (d) 10 module flush type
8.34 Supplying including and fixing of metal boxes in recessed system complete as per direction (e) 16 module flush type
SB-37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. (a) 1 module
SB-37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. (b) 2 module
SB-37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. (c ) 3 module
SB-37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. (d ) 4 module
SB-37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. (e ) 5 module
SB-37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. (f ) 8 module
SB-37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. (g ) 10 module
SB-37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. (h ) 16 module
13.2 Supplying with fitting fixing plug and socket D.B's common for lexic MCB and load Kontakt/load stop 13.2.1.1 Flush mounting distribution board with metal plug and socket. 20 Amps capacity
PVC INSULATED COPPER WIRING IN RECESSED PVC CONDUIT WITH SINGLE CORE STRANDED COPPER CONDUCTOR SPECIFIC BRAND OF MATERIALS (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) 4.7 Wiring for drawing sub-main line with P.V.C. insulated unsheathed 1.1 K.V. grade (I.S.I marked, R.R cable/Finolex/Havells make) single core copper conductor cable in with earth continuity in recessed PVC conduit wiring system. 4.7.1 With 2 X 2.5 sq.mm + earth continuity with 1 X 2.5 sq. mm PVC insulated unsheathed single core copper conductor cable in 20mm. dia., 2mm thick
4.7 Wiring for drawing sub-main line with P.V.C. insulated unsheathed 1.1 K.V. grade (I.S.I marked, R.R cable/Finolex/Havells make) single core copper conductor cable in with earth continuity in recessed PVC conduit wiring system. 4.7.2 With 2 X 4 sq.mm + earth continuity with 1 X 2.5 sq. mm PVC insulated unsheathed single core copper conductor cable in 25mm. dia., 2mm thick. Rigid PVC conduit pipes.
4.7 Wiring for drawing sub-main line with P.V.C. insulated unsheathed 1.1 K.V. grade (I.S.I marked, R.R cable/Finolex/Havells make) single core copper conductor cable in with earth continuity in recessed PVC conduit wiring system. 4.7.3 With 2 X 6 sq.mm + earth continuity with 1 X 4 sq. mm PVC insulated unsheathed single core copper conductor cable in 20mm. dia., 2mm thick. Rigid PVC conduit pipes.
SUPPLYING AND FIXING RIGID pvc CONDUIT IN SURFACE AND RECESSED SYSTEM (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) Supplying including fitting and fixing of rigid PVC conduit pipes in recessed wiring system including cutting the wall beam column etc. and making finish the its original Architectural view. 6.1(a) 19mm dia, 1.5mm thick rigid PVC, conduit
Supplying including fitting and fixing of rigid PVC conduit pipes in recessed wiring system including cutting the wall beam column etc. and making finish the its original Architectural view. 6.2(b) 25mm dia, 1.5mm thick rigid PVC, Conduit
Supplying including fitting and fixing of rigid PVC conduit pipes in recessed wiring system including cutting the wall beam column etc. and making finish the its original Architectural view. 6.3 32mm dia
FITTING AND ACCESSORIES (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT 11.15 Supplying and fixing fancy wall bracket of Anodized aluminium 12mm. Dia. Fixed on 3mm thick 170 mm X 40mm M.S. plate with brass bracket lamp holder including shade etc. and connection.
11.21 Supplying and fixing 200/250/305 mm. dia. (Normal size) flush type circular ceiling fittings complete with holder, Aluminium anodized back plate and brass holder including connections etc. (b) 250mm dia. Etc. as required
11.10 Supplying and fixing brass batten holder including connections etc. complete (without shades &
11.25 Supplying and fixing frosted glass shed of 100 mm dia. (Normal size) as required
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing brass batten holder/angle holder/decorative bracket/bulk head fitting etc.
11.32 Supplying and fixing of Cell bell (Buzzer) including 5 amps capacity flush piano type bell push switch including connections etc. as required complete.
PROVIDING EARTH, LOOP EARTH AND EARTH STATIONS AND LIGHTING CONDUCTOR (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) 193(a) Installation of earth station with 40mm. Dia and 4.50 metre long G.I. pipe with necessary G.I.reducing socket 40mm X 20mm size locking arrangement with hinged cover plate, funnel, G.I. nuts, through bolts etc. for putting pipe and re- fitting with necessary emclosure on the top etc. as
22.12 Extra for using salt (5 Kg) and Charcoal 64 kg for pipe earthelectrode as required.
22.1 Installation of Earth station with necessary Earth plate including providing all accessories masonary enclosure with cover plate having locking arrangement and 20 mm. dia. G.I. pipe, watering pipe with funnel, G.L. bolts, nuts, checknuts etc. but without Charcoal or cock and salt as required. With 600mm X 600mm X 3mm. Thick (10.5Kg. approx) Copper earth plate.
21.2 (C ) Extra for charcoal (96 Kg.) and salt (5 K.g) for G.I. / Copper plate earth electrode as required complete.
22.23 Supplying and laying G.I. strips 0.50 metre below ground level as strip earth electrodes including soldering, excavation work and refilling etc. as With 25mm X 4mm G.I. Strip
22.24 Supplying & laying of 25 X 4 mm. size Copper strip in 40mm. dia from earth electrodes including providing and fixing necessary bend etc. including soldering excavation work as refilling etc.
22.25 Providing and fixing 25mm X 4mm. Copper strip on surface or in recessed fitted with necessary copper saddles including connection etc.
22.28 Providing and fixing 25mm X 4mm. G.I. Strip on surface or in recess earth connection fitted with necessa G.I. Saddles including connection etc.
22.31 Providing and fixing of lighting conductor final made of 25mm. Dia 300 mm copper tube having single prong at top with 85 mm. dia 3mm. Thick copper base plate including making and
22.29 Providing and fixing G.I. Strip 20mm X 3mm. Thicks on parapet and surface or wall for lighting (a) For horizontal runs
22.29 Providing and fixing G.I. Strip 20mm X 3mm. Thicks on parapet and surface or wall for lighting (b) For vertical runs
Ceiling Fan, Exhaust Fan & Cabin Fan (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) 27.1.6 Supplying including fitting fixing of high speed A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections etc,. as required complete and as directed by the Department. (a) 1200 mm sweep
27.2.1.8 Supplying including fitting fixing of A.C. Exhaust fan in the existing hole on the wall of following sweeps and making necessary connections etc. as required complete and as directed by the department. (a) Domestic (i) 300mm sweep
27.4 Supplying including fitting fixing of swing wall fan complete with all accessories and making necessary connections etc. as required completeand as directed by the department.
MCBDB/MCB/RCCB OF SPECIFIC BRAND (ALL PRODUCTS SHOULD BE ENERYGY EFFICIENT 14.1 Supplying fitting and fixing industrial plug & Socket in surface mounting SP sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar complete with making necessary connection etc. as specified and directed by the deptt. [legrand/merlin gerin/ Hagger make]
15.6.1 Supplying with fitting and fixing sheet steel, phosphatised, powder painted double door surface mounting SPN MCB DB (IP-43 protection) incorporated with bas-bar, Neutral link, earth bar and din rail etc. fitted on wall with grounting nuts & bolts as reqd. complete with making necessary connection as specified and directed by the deptt. (a) 12 way SPN Double Door
15.8.1 Supplying with fitting and fixing sheet steel, phosphatised, powder painted double door surface mounting TPN MCB DB (IP-43 protection) incorporated with bas-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.[Legrand /Merlin Gerin/Hagger make] (c ) 8 way TPN (4+24) double door
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the folloowing capacity complete with making necessary connection as approved, specified and directed by the deptt. [Legrand/Merlin Gerin/Hagger make] A. B Series 1. Single Pole 10KA 240/415 50 Hz MCB (a) 6A
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the folloowing capacity complete with making necessary connection as approved, specified and directed by the deptt. [Legrand/Merlin Gerin/Hagger make] A. B Series 1. Single Pole 10KA 240/415 50 Hz MCB (b) 10A
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the folloowing capacity complete with making necessary connection as approved, specified and directed by the deptt. [Legrand/Merlin Gerin/Hagger make] A. B Series 1. Single Pole 10KA 240/415 50 Hz MCB (c ) 16A
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the folloowing capacity complete with making necessary connection as approved, specified and directed by the deptt. [Legrand/Merlin Gerin/Hagger make] A. B Series 1. Single Pole 10KA 240/415 50 Hz MCB (d ) 20A
16.3.2 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt. [Legrand/Merlin 1. DP 10 KA 240/415 50 Hz MCB (C series) 25A
16.3.2 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt. [Legrand/Merlin 1. DP 10 KA 240/415 50 Hz MCB (C series) (d) 32A
16.16 Supplying with fitting and fixing 100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as specified and directed by the deptt. 1. 300mA sensitivity 440/415 50Hz 4P RCCB [b] 63A
U.G. POWER CABLE LAID THROUGH GROUND (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) 32.1.3.4 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 11 KV gd aluminium conductor LT armoured U.G. cable laid in ground/partially in air (10.0% of cable length) including excavation of trench upto depth of 75cm, refilling, protective brick covering, sand cushioning etc. complete handling of surplus spoil, 32.3.2.1 4.00 mm2 3core U.G. cable
32.1.3.4 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 11 KV gd aluminium conductor LT armoured U.G. cable laid in ground/partially in air (10.0% of cable length) including excavation of trench upto depth of 75cm, refilling, protective brick covering, sand cushioning etc. complete handling of surplus spoil, 32.3.2.1 6.00 mm2 3core U.G. cable
32.5.2.1 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 11KV gd aluminium conductor LT armoured U.G. cable laid in pucca flooring road crossing, drain crossing and partially in air through G.I. Pipe (Tata/Nezone make) with necy bend and socket including excavation and refilling the trence and making good damage. 4 mm2 3 core u.G. Cable in 50mm dia medium quality G.I. Pipe
32.5.2.1 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 11KV gd aluminium conductor LT armoured U.G. cable laid in pucca flooring road crossing, drain crossing and partially in air through G.I. Pipe (Tata/Nezone make) with necy bend and socket including excavation and refilling the trence and making good damage. 6 mm2 3 core u.G. Cable in 50mm dia medium quality G.I. Pipe
23.1.6 Supplying, installation, tetsing and commissioning of the following prewired CFL/Flourescent luminaries complete with all accessories such as ballast, starter etc. directedly on wall/ceilling including connection with 1.5 sq.mm PVC insulated single core copper conductor as reqd. and as directed bt deptt. d(iii) Box type luminarious with copper ballast and 1 X 36 watt. Flourescent tube. (Havells make) model- LHIF11104009
ECBC 3.1.1 Complete CFL luminarious 1 X 11 W CFL
Fabrication, supply and erection of 4.5 Mtr. Long 75mm dia MS pole with MS base plate of 300 X 300 X 10mm thickness at the bottom of the pole with fixing arrangement for post top lantern and to accommodate a junction box. The foundation is of cement concrete of 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate) Size 0.8 X 0.8 X 35 Cu.m with collar of size 0.4m dia X 0.5m height to accomodate the looping type cable end box including excavation and refilling etc. as required
Supplying & installation of LT cable rout marker with inscription, bolted/welded to 35cm X 35cm X 6mm iron, 60cm long of following sizes 150mm dia CI marker
Supply installation testing and commissioning of WALL WASHER Light Chrome finish, integrated switch of make Philip Cat. No. QWZ 803 or eqivalent including supply of 1 X 40W GLS lamp.
Supplying installation testing and commissioning of Brass Bed Light of make Decon Cat No. 05 BT or equivalent including supply of 1 X 60W GLS
Recessed type Night Lamp/ Skirting Light of reputed make with 1 No. of 15W incandescent
Supply installation testing and commissioning of compect flourscent fittings with white powder coated CRCA sheet housing with opal acrylic diffuser and decorative end plates of make Baiai Cat No. BJEXL 111 or equivalent with 1nos 'S' type 11W CFL Lamps. (CFL(M)
LANDSCAPING WORKS: Cast in situ cement concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165mm respectively, 250mm high in M20 grade PCC on M10 grade foundation having 50mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) Using Concrete Mixer
20.10 Supplying and planting of suitable plant materials for preparation protective/external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (A) Adopting Single Row Planting Method (I) With Duranta
5.7.3.4 Providing polished OM'S INTERLOCKING PAVERS tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessary finished with flush pointing with Fix-A Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (a) 60mm thick
20.12 Supplying and planting of ornamental trees (plant saping height 1'-0") including pit making (60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (A) Neem/Bakul/Kadam/Palash/Ajar/Gulmohar
20.12 Supplying and planting of ornamental trees (plant saping height 1'-0") including pit making (60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (B) kanchan/Nahar
20.12 Supplying and planting of ornamental trees (plant saping height 1'-0") including pit making (60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (C ) Sonaru
20.12 Supplying and planting of ornamental trees (plant saping height 1'-0") including pit making (60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (D ) Nil Gulmohar/Debdaru
20.13 Supplying and planting of omamental shurb ( plant sapling height 1'-0"), including pit making(60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (B) Togor
INTERIOR DECORATION WORKS: Carpet sinthetic non woven 900mm X 1800mm
Door matt synthetic 400mm X 600mm
Sofa (Single)
Sofa (Double)
Center table (Alice)
Glass Almirah (glass door units)
Steel Almirah (Storwel plain)
Cabinet small
Cupboard
Aqua guard
EXTERNAL ELECTRIFICATION: 35.1 Supplying installation , testing and commissioning of following raing copper wound out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge cost of LT and HT metering etc.( excluding load security and making necessary arrangement for charging approval of the sub- station from the complete authority as directed and specified by the deptt. Transformer should be as per CEA guide line as amended up to date 200 KVA star rating up to 5 star above 200 KVA as per guide lines cusses along with LV endurance. 35.1.2 63KVA, 50Hz 11/0.433 KV oil filled transformer with off circuit tap change.
OVER HEAD COME: 36.6 Supplying and fitting fixing of galvanized channel of L.T. T. cross arm complete with clamps, bolts, nuts etc. as required and as directed by the department.
36.11 Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps, blots, nuts etc. as required and as directed by the department.
36.14 Supplying and erection of 11 KV pin insulator (Poly) with G.I pin bolts and nuts coach screws etc. as required and directed by the deptt.
36.16 Supplying and erection of 11 KV disc insulator (Poly) 45 KN with hardwere fittings etc. as required and as directed by the deptt.
36.22 Supplying and fitting of 11 KV 400 A gang operated switch all accessories complete as directed by the deptt.
36.23 Supplying and fixing 11 KV 150 A.D.O. fuse set complete as required and as directed by the deptt.
36.24 Supplying and fixing 11 KV 5 KA lighting arrestor (Poly) set complete as required and as directed by the deptt.
36.25 Supplying and fitting fixing pole clamp complete as required and as directed by the department.
36.33 Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the deptt.
29.1.2.3 Supplying including installation, testing and commissioning of Hi-Wall Non Ductable Type Split Air Conditioner of 1.5 ton capacity having proper cooling capacity single phase 3 STAR Model complete with corded remote, copper pipe connection between indoor & outdoor unit, electrical connection etc. (Blue star Make)
Supplying with fitting and fixing voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND/Vee 31.2.4 3.0 KVA Automatic Input 120-280 V Out put 200-240 V
DEEP TUBE WELL: 5.3.2 Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00 after first 3.00 depth and delivering the same in nearest P.W.D. camp in the small tin container (container scaffolding tools etc. will have to be arranged by the contractor at his own cost).
5.3.4 Labour for boring hole for inserting tube well pipes through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the department. (vi) Bore hole of 200mm diameter
5.3.5 Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. II. PVC Pipe SUPREME/PRINCE/FUSION SFMC Brand (vii) 160mm diameter
5.3.6 Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevent IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes concentrically in the casing pipes complete as directed G.I Pipe (a) TATA/SAIL (medium)(sockets should be welded to the pipes) (iv) 50mm diameter
5.3.8 Supplying fitting and fixing brass Tez filter 2.00 metre long.
5.3.11 Supplying fitting and fixing check valve (non return valve) including thread to pipes. (iv) 50mm diameter.
5.3.12 Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained.
5.3.13 Flushing, clearing, washing and watering of the tube well
IRON REMOVAL WATER FILTER 6.3.2 Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour of DOLPHIN make with all necessary fittings such as valve, bib cock, pipe connection etc. with a free maintanance period of six months. (A) With Zoloto fittings (I) 1000 liters capacity (a) 4mm thick Vessel.
39.3.6 5 HP single phase centrifugal monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter (Crompton/Greaves/Control & switch Gear/BCH/ L&T/Siemens make)
SITE EARTH FILLING: 1.4 Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales necessary forest royelty, sales tax, land compension, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed. (b) other than Guwahati city
SRI BISWAJIT LODH ROY
Biswajit Debnath
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .