| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹17.8 L+₹68,762.77 (4.02%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹18.3 L+₹1.2 L (6.80%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹22.2 L
EMD Value
₹44,400
Closing Date
14 Feb 2022, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-58/2021-22 REPAIRS TO PUMP SETS, DG SETS, WATER SUPPLY LINES, UG SUMPS, SWTS, INTERNAL ELECTRIFICATION, CEILING FANS, COOLING APPLIANCES, DESERT COOLERS, VOLTAGE STABILISERS, EARTHING PITS, LT PANELS, STREET LIGHTS AND OTHER MISCELLANEOUS W
2022_MES_501994_1
GE AF/AMB-58/2021-22
Open Tender
Civil Works - Water Works
Item Rate
335 days
GE AF AMBALA
ALL AS PER NIT AND TEDNDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹44,400
Yes
25 Mar 2022
17 Jan 2022
16 Feb 2022
17 Jan 2022
14 Feb 2022
1 Feb 2022
24 Jan 2022 - 28 Jan 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking out / down old unserviceable cable, protection pipes, brick covers, etc. from any location and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, covers, tubing, cushioning will be measured and paid separately under respective item herein
4 core 16sqmm
4 core 25sqmm
3.5 core 50sqmm
3.5 core 70sqmm
3.5 core 95sqmm
3.5 core 120sqmm
Supplying, laying / fixing, testing and commissioning of electric cable 11000V grade earthed aluminium conductor 3 core 95sqmm XLPE insulated, armoured cables conforming to IS-7098 (Part-I)-1988, XLPE insulation, PVC tape inner sheath conforming to IS-1554 (Part-I)-1988, PVC type ST-2 outer sheath conforming to IS-5831-1984 including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed Notes: (i) Cable shall be having manufacturing date not earlier than Dec 2020. Cable shall have standard markings as per IS (ii) Excavation/earthwork, bricks, sand cushoing and GI pipe shall be measured and paid separately under respective items herein
Supplying, fixing / laying PVC insulated aluminium conductor cable, 2 core 6sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in service connections suspended by and including insulated hangers not more than 1.0m c/c and 4mm suspension wire complete all as specified and as directed
Supplying, fixing / laying PVC insulated aluminium conductor cable, 2 core 10sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in service connections suspended by and including insulated hangers not more than 1.0m c/c and 4mm suspension wire complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundation filling, mass concrete, etc. complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to PCC/steel poles 9/11m high/long with two coats of synthetic enamel paint in black & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
M&L in repairs for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed
M&L for restringing only ACSR conductor, straightening properly on insulators and binding with aluminum tape /binding wire/conductor, jumper, etc. complete all as specified and as directed
M&L in repairs for stringing of aluminum conductor steel reinforced (ACSR), wesel type, stringing properly on insulators and binding with aluminum binding wire, jumpers, etc. complete all as specified and as directed
M&L for taking down insulators of any capacity / type from any locations / position and disposing off complete all as specified and as directed
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, 02Nos. galvanised iron washers and 01No. galvanised iron nut, 100mm height 65mm dia for 1100V grade of size 150mm dia and 150mm long complete all as specified and as directed
S&F shackle type porcelain vitreous white insulator, 1100V grade, 75mm in height and 90mm dia including galvanised mild steel strap of size 31x3mm, 12mm dia insulator bolts, washers and nuts complete all as specified and as directed
S&F loop type porcelain insulator, vitreous white/brown/ green overall dimension 65x90mm, clearance of hole 16mm complete all as specified and as directed
M&L for stay assembly and accessories as shown in electrical plate No. 1 of SSR Part-I, using stay rod of 16mm dia, stay plate 6mm thick of size 300x300mm including stay wire 7/3.15mm dia of suitable length complete all as specified and as directed
S&F in repairs porcelain line separator, screw type for LT OH line suitable for 4 wire system of 1100V grade complete all as specified and as directed
S&F in repairs porcelain line separator, screw type for LT OH line suitable for 2 wire system of 1100V grade complete all as specified and as directed
M&L for switch air break gang operated, tripple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200A 11000V grade with 12 insulators including 25mm dia GI medium grade pipe, supports worked from ground level vertically operated including taking down old unserviceable switch from existing place and disposing off complete all as specified and as directed
M&L for filtering transformer oil with stream line filtration plant in service connections having dielectric strength below 50kV, testing of oil after filtration and removing moisture content and acidity test of oil, insulation resistance, etc. and refilling in transformer complete all as specified and as directed
Supplying, filling / topping up transformer oil of breaking down capacity 50kV, conforming to IS-339-1989 in transformers / voltage stablisers as required complete all as specified and as directed
S&F in repairs LT side stud of gun metal / brass metal of suitable size of existing specification and make for transformer of capacity 50 to 315kVA at site including nuts, washers, gasket, bushes, etc. complete all as specified and as directed
S&F in repairs LT/HT side bushes of existing size, specifications and make of equipment complete all as specified and as directed
S&F in repairs HT/LT bushing rubber (ring) gaskets set of transformer complete all as specified and as directed
M&L for disconnecting transformer in any position / location and rewinding of HV/LV sides with super enamelled copper winding as per original gauge & data / DPC winding as per relevant IS, replacing insulating material viz. cotton tape, packing, sleeves, etc. vacuum impregnation and baking of coil core assembly complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 200A 36kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 125A 25kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 63A 16kA adjustable thermal release type complete all as specified and as directed
M&L danger notice plates, for LT of size 200x150mm, made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts complete all as specified and as directed
M&L danger notice plates, for LT of size 250x200mm, made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts complete all as specified and as directed
M&L for taking out defective underground cable from trenches by digging out removing cable covers, etc. rectifying the fault including replacing of cable joints as required, making good the existing sand bed and relaying cable, covers and filling in and levelling after completion complete all as specified and as directed Note: Cable joints if replaced as directed will be measured separately under resective items
S&F fuse wire copper tungstan of required size at site complete all as specified and as directed
S&F in repairs recess/surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36W, PF 0.9, CRI> 70, L 70 with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod complete all as specified and as directed
S&F in repairs recess/surface mounting LED flat panel 8"x8" with high efficient LED & glare free full window opal diffuser of 36W, PF 0.9, CRI> 70, L 70 with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod complete all as specified and as directed
M&L for cable jointing kit for 11kV earthed grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core, 50 to 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 11kV earthed grade cable for outdoor end termination heat shrink type joint with jointing material and accessories suitable for 3 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 50 to 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for LT cable jointing kit, end termination heat shrink type, with jointing material and accessories suitable for 240V 35 to 120mm², XLPE aluminium conductor cable complete all as specified and as directed
M&L for disconnecting electric connection of underground LT / HT, XLPE cable, 25sqmm to 300sqmm 3/3.5/4 core from both sides and locating faults in cable with fault locating machine in the entire length and testing cable with the help of modern fault detector equipment and commissioing of cable complete all as specified and as directed Notes: (i) Work will be executed after obtaining proper shutdown from main power house after making prior intimation and permission, etc. (ii) Cost of excavation earthwork, power supply to machineries shall be deemed to be included in the quoted rate
M&L for taking down eletric poles any type including disconnecting mains and connections, all necessary T&P, safety precautions, etc. as required as site from any locations complete all as specified and as directed
Supply, erect in position and fixing steel tubular swaged electric poles with CI base plate (300x300mm and 6mm thick), finial taper plug, pole caps, bolts, nuts and screws type 410 SP-31, 9m long with detachable bracket arms including two coats of silver paint over shop coat of primer at any locations complete all as specified and as directed Note: Excavation / earthwork and PCC coping etc. will be measured and paid separately under respective items herein
M&L for servicing of DG sets, 63 to 160kVA at site in any location / position, decoupling the engine from alternator, cleaning of diesel tank internally thoroughly with water and air pressure, removing the sludge from the tank, opening of oil chamber cover, draining out used engine oil, cleaning the chamber throughly internally and refixing the chamber cover, taking off and replacing worn out / unserviceable parts, replacing worn out thimbles, bolts, washers, 'O' rings, etc. and making DG set functional including all testing on full load, etc. and works as detailed hereafter complete all as specified and as directed Notes: Replaced spares / components will be measured and paid in respective items. Minor spares and thimbles, bolts, washers, 'O' rings, etc. shall be deemed to be included in the quoted rates
M&L for decanning of used engine oil of DG sets, cleaning the oil chamber, topping up and filling the same with fresh engine oil of grade 20W 40 and of existing make complete all as specified and as directed
Supply and pouring fresh coolant in DG sets as per existing specifications and manufacturer's recommendations complete all as specified and as directed
Replacement of lubricant oil filter element (set of two)
Replacement of fuel filter element (set of two)
Replacement of bypass filter
Replacement of air cleaner secondary filter element
Replacement of solenoid coil as per existing size
Replacement of 'V' belt set as per existing size
Replacement of oil pressure gauge suitable for 63 to 160kVA DG set
Replacement of high pressure diesel pipe suitable for 63 to 160kVA DG set
Replacement of high pressure engine oil pipe suitable for 63 to 160kVA DG set
Supply and placing silica gel in existing position / place as required brought in sealed packets complete all as specified
M&L for taking out old unserviceable self starter of capacity 12volt suitable for 160kVA DG set, reparing the same by rewinding armature, field coil, replacing the pinion, carbon brush and fixing at its original position and testing complete all as specified and as directed
S&F in repairs GCU (generator control unit) suitable for 63 to 160kVA DG sets of existing make and type including testing complete all as specified and as directed
S&F in repairs starting switch suitable for 63 to 160kVA DG sets of existing make and type complete all as specified and as directed
S&F in repairs oil safety switch suitable for 63 to 160kVA DG sets of existing make and type complete all as specified and as directed
S&F CI non-return valve of size 150mm conforming to IS-1538 with ISI marked Tee (equal or unequal) dead flanges/plug, connecting pieces, tapers, collars, reducers, etc. and testing on fixing including taking out old unserviceable valve and disposing off complete all as specified and as directed
M&L for collecting unserviceable voltage stabilizer of capacity 75kVA from Site-IV Kalpi, transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and repalcement of defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get correct output and transporting back the same to MES store yard complete all as specified and as directed Notes: (i) Cartage shall include both loading and unloading, etc. (ii) Replacement of defective spares / rewinding of transformers of voltage stabilizers will be measured & paid separately under respective items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted in this item
S&F printer circuit card of 75kVA voltage stablizer complete all as specified and as directed
M&L for servicing and repairing AMF panel for 63kVA DG set at site including changing of contactor (2NO+2NC BCH15 T22 BCH 15) and relay (MC320KE32 MD DMD control relay) and all other minor unserviceable spares/items and making the panel functional complete all as specified and as directed
M&L for servicing and repairing LT panels of STPs by replacing defective parts of boiler motor, etc. viz. contactor, relay, preventors, indicators, controlling switches, winding and all other minor unserviceable spares/items and making the panel serviceable, testing for overall functionliy of the STP including load balance etc. complete all as specified and as directed
S&F servo controlled motor for dimmer stat complete all as specified and as directed
S&F sproket set for servo controlled motor complete all as specified and as directed
S&F water pump of existing size / type suitable for 63 to 160kVA DG sets complete all as specified and as directed
S&F in repairs fan belt of existing size/make of DG set capacity 63 to 160kVA
S&F in repairs solenoid coil of requisite capacity of existing size/make of DG set capacity 63 to 160kVA and testing
S&F battery 180AH 12V, set including initial charging, filling of distilled water, etc. including copper connecting lead and testing on installation and taking off and disposing off old unserviceable battery complete all as specified and as directed
S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for connection and tapping from existing supply pipe lines to resume water supply including taking up/down old unserviceable tubings and disposing off complete all as specified and as directed for the following bores:
20mm bore
25mm bore
40mm bore
50mm bore
M&L for run lead joint for CI pipes 150mm bore including jointing material like spun yarn, white lead, bolts, washers, mineral wool, etc. complete all as specified and as directed Note: Excavation and earthwork shall be measured and paid separately under respective items
M&L for run lead joint for CI pipes 100mm bore including jointing material like spun yarn, white lead, bolts, washers, mineral wool, etc. complete all as specified and as directed Note: Excavation and earthwork shall be measured and paid separately under respective items
M&L for run lead joint for CI pipes 80mm bore including jointing material like spun yarn, white lead, bolts, washers, mineral wool, etc. complete all as specified and as directed Note: Excavation and earthwork shall be measured and paid separately under respective items
M&L for flanged joints for cast iron pipes 150mm bore including nuts, bolts, washers, rubber gaskets, fiber boards, etc. complete all as specified and as directed Note: Excavation and earthwork will be measured and paid separately under respective items
M&L for flanged joints for cast iron pipes 100mm bore including nuts, bolts, washers, rubber gaskets, fiber boards, etc. complete all as specified and as directed Note: Excavation and earthwork will be measured and paid separately under respective items
M&L for CI specials / fittings like bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc.), tee pieces single branch 'Y' junction, double branch, cross (all sockets or socket and spigot), collars, caps, plug, etc. upto and including 200mm bore complete all as specified and as as directed Note: Lead joint, excavation and earthwork shall be measured and paid separately under respective items
M&L for CI pipes with socketed and spigot ends suitable for tyton joints centrifugally cast (spun) class LA conforming to IS:1536 cut to any length and laid in trenches including rubber gaskets joints complete all as specified and as directed of the following sizes: Note: Fittings shall be measured and paid separately under respective item
80mm bore
100mm bore
150mm bore
S&F sluice valve, 150mm dia, cast iron body class PN 1 marked both ends fanged with brass spindle and brass check nuts with caat iron hand wheel including jointing material like rubber insulation sheet 3mm thick, bolts, nuts and fixed to pipe line, including testing on installation and taking out of old unserviceable valve and disposing off complete all as specified and as directed
M&L for removing / taking out non-clog type submersible sewage pumping set capacity upto 12HP from sewage well, with column pipe, duck foot bend etc., dewatering all sewage water with pump lifting, dismantling the pump for assessing and making good for running conditions by repair / replacement of all unserviceable spare parts like upper lower bearing, seal assembly, bottom plate, cable gland, neoper cable protector, cable seal, cable clamp and screw, plug joint ring, gasket neoper, circlip spring, impeller key, impeller nut, electronic timer, eye bolt, etc. as required and replacement of O ring set, full fasteners set & Nitrile `O` ring set, checking of all bearings & mechanical seal by cleaning greasing and reassembling the same including hydraulic air testing and balancing, changing of lubricant oil, re-assembling, lowering the same into the sewage well and making necessary connections, testing complete all as specified and as directed
M&L for removing / taking out motor from submersible pump 20 to 40HP, 3 phase, 415V, dismantling the pump for assessing and making good for running conditions by repair / replacement of all unserviceable spare parts like upper lower bearing, seal assembly, bottom plate, cable gland, neoper cable protector, cable seal, cable clamp and screw, plug joint ring, gasket neoper, circlip spring, impeller key, impeller nut, electronic timer, eye bolt, etc. as required, re-winding with super enameled copper wire of existing gaugeand pattern, replacement of O ring set, full fasteners set & Nitrile `O` ring set, checking of all bearings & mechanical seal by cleaning greasing and reassembling the same including hydraulic air testing and balancing, changing of lubricant oil, re-assembling and making necessary connections, testing complete all as specified and as directed
M&L for rewinding of motor upto 12HP of non-clog type submersible sewage pumping set with suitable size of copper winding wire including all insulation material & motor winding provided with thermal switches for protection against excessive temperature rise complete all as specified and as directed
M&L for taking up and lowering column pipe flanged 80/100mm bore with 2Nos new submersible cable and repaired pump set in the existing bore hole of tube wells with submersible cable and pump set of any capacity from bore hole of tube wells located in different locations for carrying out repairs complete all as specified and as directed Notes: (i) The depth of bore well shall be 60 to 95m and the work shall be carried out in 25Nos. bore wells (appx) (ii) Repair/replacement of spares/parts of pumps, submersible cable and column pipe will be measured and paid separately under respective items hereinafter
S&F column pipe 100mm bore, GI, medium grade with 2Nos. flanged fixed at both ends 10ft long complete all as specified and as directed
M&L for installation, testing and commissioning chemical dozing system complete with motor and pump having injection pressure 10 bar of capacity 6litres/hour including all necessary parts viz. NRVs, head, assembly, diaphragm, injecting valves, 100litres PVC tank with lid, etc. including dismantling and disposing off old unserviceable dozing system complete all as specified and as directed
M&L for cleaning of internal surfaces of RCC SWT of capacity 50000 gallons capacity by scrubing the surfaces with the help of coir brush, jute cloth and flushing out / wiping clean all the accumulated mud / silt inside the tank, then applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. and writing tank number, capacity of tank, date of cleaning with white synthetic enamel paint over a black synthetic enamel paint base (of suitable dimensions) with size of letter 4" height complete all as specified and as directed
M&L for cleaning of internal surfaces of RCC overhead tank of 50000 gallons capacity including staging to a height approx 18m, by scrubing the surfaces with the help of coir brush, jute cloth and flushing out all the accumulated mud / silt inside the tank, then applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. and writing tank number, capacity of tank, date of cleaning with white synthetic enamel paint over a black synthetic enemal paint base (of suitable dimensions) with size of letter 4" height complete all as specified and as directed
M&L for potability water chemical analysis testing of water to be conducted through laboratories authosied by NABL, PPCB & CPCB for analyis of pH, colour, odour, taste, turbidity, total hardness, total alkalinity, iron, chloride, residual free chlorine, fluroide, total dissolved solids, sulphate, nitrate, total Coliform, e-coli, etc. including collecting of water from the source in a specialised glass bottle designated for this purpose, submitting samples and collecting reports from the laboratory complete all as specified and as directed Notes: (a) Laboratory shall be as approved by the GE. The Contractor has to get the same approved in due course of time (b) All requirements for collection, submission, etc. of samples, cartage, etc. shall be included in the quoted rate (iii) The Contractor has to submit reports to the Engineer-in-charge for his approval and the same shall be submitted and kept on records and produced alongwith claims for such testing works in RARs
M&L for potability water chemical analysis testing of water to be conducted through laboratories authosied by NABL, PPCB & CPCB for analyis of BOD & COD including collecting of water from the source in a specialised glass bottle designated for this purpose, submitting samples and collecting reports from the laboratory complete all as specified and as directed Notes: (a) Laboratory shall be as approved by the GE. The Contractor has to get the same approved in due course of time (b) All requirements for collection, submission, etc. of samples, cartage, etc. shall be included in the quoted rate (iii) The Contractor has to submit reports to the Engineer-in-charge for his approval and the same shall be submitted and kept on records and produced alongwith claims for such testing works in RARs
Supply only chlorination chemical highly efficient (high strength) calcium based granular disinfectant, more stable than chlorine gas, highly stable, in sealed container to check no sodium, iron/mercury/heavy metal contaminations, etc. complete all as specified Notes: (i) Paid vouchers of calcium based granular disinfectant shall be submitted (ii) The calcium based granular disinfectant shall be brought at site/store in sealed plastic container of appropriate capacity / size asked (iii) The brand of chemical shall be as approved by the GE
S&F star delta control panel starter 415V 3phase suitable for montoblock motor of capacity upto 20HP including all necessary contacts, relays, under/over voltage protection, short circuit protection, overload, dry run protection, phase unbalance & sequence protection, single phase preventor, inbuilt auto-start switch, digital display (volt & amps) including fixing arrangement like clamp, nuts & bolts of suitable sizes and taking out old unserviceable starter of any type and disposing off complete all as specified and as directed
S&F star delta control panel starter 415V 3phase suitable for montoblock motor of capacity upto 40HP including all necessary contacts, relays, under/over voltage protection, short circuit protection, overload, dry run protection, phase unbalance & sequence protection, single phase preventor, inbuilt auto-start switch, digital display (volt & amps) including fixing arrangement like clamp, nuts & bolts of suitable sizes and taking out old unserviceable starter of any type and disposing off complete all as specified and as directed
S&F in repairs submersible flat copper 3core 10sqmm 1100V grade, ISI marked including passing with column pipes duly tied with nylon rope complete all as specified and as directed
S&F in repairs aluminum cable of size 10sqmm 2 core in connecting up fittings, etc. complete all as specified and as directed
S&F in repairs aluminum cable of size 10sqmm 2 core in connecting up fittings, etc. complete all as specified and as directed
M&L for preparation of surfaces viz. panels, feeders, etc. at any location and position, by scrapping old paints, smoothening, etc. and spray painting with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer, writing SM/MES No. in black of approved tint in synthetic enamel paint of approved font complete all as specified all as directed
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed on walls, ceiling etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 5A one way switch
One bell point controlled by one bell push
One switch socket outlet 3 pin 5A on independent board
One switch socket outlet 3 pin 5A on same board
M&L for point wiring with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through and including PVC casing capping not less than 20mm wide and accessories, surface on walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for 3 pin 15A switch socket power point on independent board complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 6A, 240V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 16A, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 6A flush modular type, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 16A flush modular type, ISI marked, 240V complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 240V complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 15A, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 5A flush type, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, two in one, 3 pin, 5A flush type, ISI marked, 240V complete all as specified and as directed
S&F switch socket combination outlet, 2 in 1, 3 pin, 5A flush type, ISI marked, 240V complete all as specified and as directed
S&F switch socket combination outlet, 2 in 1, 3 pin, 5/15 flush type, ISI marked, 240V complete all as specified and as directed
S&F PVC lamp holder, insulated body, bracket holder / angle holder 240V complete all as specified and as directed
S&F bell push flush button type, 5A, 240V modular type complete all as specified and as directed
S&F bell push flush button type, 5A, 240V complete all as specified and as directed
S&F bell buzzer, ding dong type, 240V, single pole complete all as specified and as directed
S&F plug top 3 pin 15A 240V single phase complete all as specified and as directed
S&F plug top 3 pin 5A 240V single phase complete all as specified and as directed
S&F electronic fan regulator, stepped modular type (5 steps), 120W, 50Hz, 240V, ISI marked duly connected up complete all as specified and as directed
S&F electronic fan regulator, stepped type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F LED 1x18W batten tube light fitting, wall mounted, extruded heat dessipation, integrated crystal glass body, 230V with connector block, etc. internally pre-wired and connecting up with twin core twisted flexible copper conductor cable of suitable size, with all accessories and 18W LED tube rod including taking down and disposing old fitting any type complete all as specified and as directed
S&F in repairs LED bulb / lamp 9W suitable fo existing light fittings complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked concealed in wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
Notes for item No. 140: (i) 2 runs of 6sqmm main cable, 1 run of earth conductors and 1 run of PVC conduit as per item shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
S&F energy efficient BEE five star rated ceiling fan, 230/240V, single phase, 1200mm sweep and connecting up with provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to ceiling fan and taking down old and depositing in MES store complete all as specified and as directed
S&F heavy duty, PVC body with PVC blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 250mm sweep with lauvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts complete all as specified and as directed
S&F electric water heaters (geysers), stainless steel body, 25litres capacity, storage type, vertical mounting, with glass lined inner tank, energy efficient 5 star rated of approved design and colour, including all necessary clamps, grouting duly with holding bolts & nuts and all necessary connections at locations complete all as specified and as directed
Supplying, installing, testing and commissioning of single phase two wire digital electronic energy meter, with engineering plastic box, hinge type with seal, 10-60A, class accuracy:1, 1x230V, backelite LCD display with kWh, kW, PF, I, V and average of V, I & PF, last 12 month history for kWh, kVAh and MD with features like TOD, tamper logging, optical port for data retrieving with cable without opening engineering box, touch pad for parameter scrolling and having load temperature profile features in meter memory complete all as specified and as directed
Supplying, installing, testing and commissioning of single phase two wire digital electronic energy meter, with engineering plastic box, hinge type with seal, 10-60A, class accuracy:1, 1x415V, backelite LCD display with kWh, kW, PF, I, V and average of V, I & PF, last 12 month history for kWh, kVAh and MD with features like TOD, tamper logging, optical port for data retrieving with cable without opening engineering box, touch pad for parameter scrolling and having load temperature profile features in meter memory complete all as specified and as directed
Notes for item Nos. 145 to 146: (i) Meters shall have a mimimum 5 year manufacturer warranty. The Contractor shall replace any faulty meters as informed at any time by the Engineer-in-charge without any cost (ii) These shall be installed at locations as directed
Notes for item Nos. 142 to 146: (i) Exhaust fans, ceiling fans, electric meters shall be taken down from any location, height, positions, etc. as per site (ii) Disconnection from mains and supply shall be done with requisite safety measures (iii) All cost of loading, unloading, carting, T&P, etc. as required to deposit taken down items to MES storeyard shall be deemed to be inclusive in the quoted rates
M&L for disconnecting from main supply and taking down old damaged sheet metal enclosures complete all as specified and as directed
S&F sheet metal enclosures for MCB distribution board 415V TPN 4 way double door, flushed inside walls, etc. with 100A rated busbar with and including necessary thimbles, plugs, nuts, bolts, etc. and making good the disturbed surfaces complete all as specified and as directed
S&F sheet metal enclosures for MCB distribution board 240V SPN 8 way double door, flushed inside walls, etc. with 100A rated busbar with and including necessary thimbles, plugs, nuts, bolts, etc. and making good the disturbed surfaces complete all as specified and as directed
S&F sheet metal enclosures for MCB distribution board 240V SPN 4 way double door, flushed inside walls, etc. with 100A rated busbar with and including necessary thimbles, plugs, nuts, bolts, etc. and making good the disturbed surfaces complete all as specified and as directed
S&F metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket with and inlcuding one SP MCB 20A 10kA including taking down and disposing off old/unserviceable socket complete all as specified and as directed
S&F in repairs isolators TPN 415V, 63 to 100A, 10kA with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs isolators SPN 240V, 5 to 63A, 10kA with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs isolators SP 240V, 6 to 32A, 10kA with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F 1.5m long 25mm bore light grade GI pipe bracket duly cut to size and bent to shape required duly painted with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer, including 2Nos. MS clamps as required to fix on concrete / steel poles and taking down and disposing off old unserviceable brackets complete all as specified and as directed
S&F in repairs thermoplastic cable junction box with 02Nos. PVC gland, weather proof, IP 66/67 protection class, for outdoor installation with knock outs for cable entry of size 300x250x200mm hinged type with 4Nos aluminium bus bar of size 25x6mm and 8Nos. terminals with all required nuts, bolts, mounted on bus bars and connecting up with existing cable and duly fixed with MS clamps made out of FI 40x3mm thick with nuts & bolts as required complete all as specified and as directed
S&F in repairs LED bollard fitting 6W, powder coated aluminium body with opal diffuser suitable for landscape / garden lighting complete all as specified and as directed
S&F in repairs aesthetically disigned LED post top lantern 25W, input voltage 230VAC, 50Hz with die cast aluminium spigot & prismatic diffuser, IP-65/66 protection class including fixing arrangment like suitable clamps, nut, bolts and washers and connecting up with suitable sized of copper conductor cable complete all as specified and as directed
S&F LED street light fitting, 90W, 230V, 50HZ, suitable for operation over voltage range of 140V to 270V, duly housed in pressure die cast aluminium housing, compressing of LED with individual optical lens, electronic driver with IP 66 protection and impact reistance of IK 07, including connecting lead of 3 core 1.5sqmm flexible copper wire 1.5sqmm from ceiling rose to fitting and taking down and disposing off old unserviceable fitting complete all as specified and as directed
S&F LED flood light fitting, 120W, 230V, 50HZ, suitable for operation over voltage range of 140V to 270V, duly housed in pressure die cast aluminium housing, compressing of LED with individual optical lens, electronic driver with IP 66 protection and impact reistance of IK 07, including connecting lead of 3 core 1.5sqmm flexible copper wire 1.5sqmm from ceiling rose to fitting and taking down and disposing off old unserviceable fitting complete all as specified and as directed
S&F LED flood light fitting, 120W, 230V, 50HZ, suitable for operation over voltage range of 140V to 270V, duly housed in pressure die cast aluminium housing, compressing of LED with individual optical lens, electronic driver with IP 66 protection and impact reistance of IK 07, including connecting lead of 3 core 1.5sqmm flexible copper wire 1.5sqmm from ceiling rose to fitting and taking down and disposing off old unserviceable fitting complete all as specified and as directed
Taking down carefully exhaust fans (with or without louvers), 300/380/400mm, any type, from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Note: Cost of replaced minor spares shall be deemed to be inclusive in the quoted rates
Taking down carefully ceiling fans, 1200/1400mm sweep from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, rewinding with same gauge of wire, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Note: Cost of replaced minor spares shall be deemed to be inclusive in the quoted rates
S&F PVC 3 core chord, flexible copper insulated cable 1.5sqmm/core size, black/grey in colour and fixed / laid complete all as specified and as directed
S&F PVC 3 core chord, flexible copper insulated cable 1.5sqmm/core size, black/grey in colour and fixed / laid complete all as specified and as directed
M&L for taking down carefully water heaters / geysers of any capacity any make after disconnecting electric & water connections for carrying out repairs by replacing worn out / damaged parts / components, setting thermostat at 70oC, etc. refixing the same after carrying out necessary repairs to original place and re-connecting electric & water supply lines, testing for proper functioning on installation complete all as specified and as directed Note: Replaced parts / components shall be measured under respective items hereunder
Supply only heating element 2kW for 50litres capacity geyser ISI marked complete all as specified and as directed
Supply only heating element 1.5kW for 25/35litres capacity geyser ISI marked complete all as specified and as directed
Supply only thermostat switches of geyser of any capacity complete all as specified and as directed
Supply only indicating bulb (Red/Green) of geysers complete all as specified and as directed
S&F capacitors 2.5MFD 230V suitable for ceiling fans complete all as specified and as directed
S&F capacitors 3.15MFD 230V suitable for ceiling fans complete all as specified and as directed
M&L for taking down split type AC 1.5/2TR capacity for required servicing, cleaning of cooling coil, air filters/plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solutions, etc., checking serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches, knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed Note: Spares / components replaced shall be measured and paid separately under respective items herein
Supply only running capacitor 36MFD
Supply only running capacitor 45MFD
Supply only running capacitor 100-120MFD
Supply only starting relay 1022/1622/2000
Supply only thermostat switch 2059/2064/2054
Supply only fan motor (outdoor unit) for split type AC 1.5/2T
Supply only fan motor (indoor unit) for split type AC 1.5/2T
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split AC capacity 1.5/2T
Supply, installing, testing and commissioning of compressors of split type air conditioner in any location / position including disconnecting electrical mains, remove the refrigerant and capture it in a storage cylinder, cutting line sets, removing the condenser coil and everything around the compressor, taking out the condenser unit, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally put the rest back together and balance charging of refrigerant gas F-22/R-134A (if required) including disposing of old unserviceable condensor unit complete all as specified and as directed for the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
2Ton capacity
1.5Ton capacity
Supply, installing, commissioning and testing of complete indoor unit of split type air conditioner of capacity 1.5Ton, compatable with existing outdoor unit, of exsiting make, in any location / position including taking down old damaged unit and disposing off complete all as specified and as directed
Supply, installing, commissioning and testing of complete outdoor unit of split type air conditioner of capacity 1.5Ton, compatable with existing outdoor unit, of exsiting make, in any location / position including taking down old damaged unit and disposing off complete all as specified and as directed
M&L for charging refrigerant gas F-22/R-134A in window type / split type AC units of capacity 1.5/2Ton including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for detecting leakages of gas from window / split type air-condiioners 1.5/2T capacity in any location / position, with all necessary brazing, welding, etc. and ensuring functionaility complete all as specified and as directed
M&L for collecting unserviceable voltage stabilizer of capacity 3 to 5kVA from Site-III Baknaur, transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and repalcement of defective spare parts, rewinding with super enameled copper winding wire of existing gauge, re-assembling after making connections, testing by applying low and high voltage input to get correct output of 230V, ensuring proper functioning and transporting back the same to location or MES store yard complete all as specified and as directed Notes: (i) Cartage with loading, unloading, etc. shall be deemed to be included in the quoted rate (ii) Cost of spares replaced, rewinding of transformers of voltage stabilizers shall be deemed to be included in quoted rate
M&L for collecting unserviceable transformer of capacity 50 to 315kVA from various locations at site-III Baknaur, transporting to workshop, disassembling the unit for locating the fault by seggregating the damaged parts, including checking the serviceability of electrical parts viz. circuits relays, etc. and repalcement of defective spare parts, refilling dehydrated oil, testing for ensuring proper functioning and transporting back to the same to location re-fixing in position, re-assembling and making connections, complete all as specified and as directed Notes: (i) Cartage with loading, unloading, etc. shall be deemed to be included in the quoted rate (ii) Cost of spares replaced, rewinding of transformers of voltage stabilizers shall be deemed to be included in quoted rate
M&L for cleaning and utility servicing HT Vacuum Circuit Breaker (VCB), 11kV (outdoor type), 400/630A, 3 phase, checking of each moving parts, spring charging system, triping system, indication system, metering system, remote operation, closing & trip coil assembly and proper oiling, greasing and proper adjustment of trip bars, closing bar complete with the following testings complete all as specified and as directed (i) ON/OFF testing in local and remote position (ii) Spring charge system (iii) Tripping test in overload and earth fault position by external current injecting Kit on both primary & secondary sides (iv) Meggar testing between phase to phase and phase to earth in ON / OFF position both (v) Calibration of earth fault / over current relay Notes: (a) Tests shall be carried out through competent labs / test houses / authorised service centres as approved by the GE (b) All the test reports shall be submitted to the Engineer-in-charge and shall be made part of RAR / FB
S&F the following defective parts of voltage stabilisers of capacities 3 to 5kVA:
Voltmeter (analog) 0 to 300V single phase 50Hz AC any type
Printer circuit control card stuiable for 3kVA
Printer circuit control card stuiable for 4 to 5kVA
Relays for 3 to 5kVA
Time delay and high voltage cutoff circuit with relay suitable for 3 to 5kVA
M&L for taking out burnt winding from transformers of voltage stabilisers 3 to 5kVA, cleaning with suitable cleaning agent, preparing the core, rewinding the transformer with super enameled copper wire of existing gauge including varnishing, heating, reinstalling and testing complete all as specified and as directed
Supply, fixing, connecting and testing spring charging motor (universal motor) for outdoor type, 11kV, VCB, operated on 230V AC/ DC, with charging time less than 15seconds of approved rating complete all as specified and as directed
S&F shunt trip coil assembly suitable for HT, OCB/ VCB, operating on 24/110V system and testing complete all as specified and as directed
S&F closing coil operated on 110/24V system suitable for working of relay of HT OCB / VCB complete all as specified and as directed
S&F under voltage coil assembly suitable for HT OCB/ VCB operated on 110/24V system and testing complete all as specified and as directed
S&F in repairs indication lamp (LED type) Red / Yellow / Green colour suitable for 110V AC / 110V DC / 30V DC (as required at site) complete all as specified and as directed
M&L for replacing deteriorated / cracked top gasket set of LT/HT cable entry box of transformers of existing size and type complete all as specified and as directed
S&F in repairs electric heaters suitable for VCB (as required at site) complete all as specified and as directed
M&L for disconnecting from mains and taking down for servicing water coolers, upto 150litres capacity including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches, knobs, fan and blower, etc. replacing the damaged / faulty spares and making the water cooler to satisfactory working conditions all as specified and as directed Note: Cost of spares / parts / components viz. condensor, thermostat, copper filter, relays, door handle, etc. replaced shall be deemed to be included in the quoted rate
S&F company made new sealed compressor units for water coolers including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed for the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
80 to 150litres capacity
40litres capacity
S&F condensor fan motor of capacity 1/10 HP, 1/16HP single phase AC 220V suitable for water coolers of capacity 150litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F condensor fan motor of capacity 1/32HP single phase AC 220V suitable for water coolers of capacity 40litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
M&L for evaporator / cooling coil of water coolers of capacity 150/80/40litres, checking the serviceability, checking leakages of gas and rectifying same by welding, etc. and ensuring satisfactory working conditions complete all as specified and as directed
S&F in repairs thermostat switches of water coolers of any capacity complete all as specified and as directed
S&F in repairs water cooler taps self closing type complete all as specified and as directed
S&F in repairs starting relays of existing size for water coolers complete all as specified and as directed
M&L for charging refrigerant gas F-22/R-134A in water coolers of capacity 150/40 litres including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, filling of holes with putty, etc. and painting to water coolers with one coat of duco paint over a coat of red oxide primer complete all as specified all as directed of the following capacities:
80/150litres capacity
40litres capacity
S&F company made new sealed compressor units for refrigerators, 165/180litres capacity including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
S&F lightening arrestor (set of three), expulsion type, 65KA discharge capacity transmission class, suitable for 11KV system including staging as required, testing on installation including taking down and disposing of old / damaged arrestors complete all as specified and as directed
M&L for preventive maintenance to functional earthing GI any type, by mechanically checking earth resistance value and bringing up the same to required state by developing and adding new chemical mixture of sodium carbonate, magnesium sulphate, common salt, charcoal, etc. and ensuring required earth resistance value on completion including all necessary excavation/earthwork complete all as specified and as directed
Supply, installation, testing and commissioning maintenance free tripod chemical earthing system consisting of 3Nos. of solid copper earth rod of 10ft length, 17.2mm dia and 3m long on outer surface having 250microns (minimum thickness) with exothermically jointed copper bus bar of 25x3mm for long lasting and connecting each copper rod and the exothemically jointed bus bar, both CPRI tested on at leat 25kA fault current ensuring high current carrying capacity of the system and earth rod should be certified by laboratories confirming to comply with UL 467 international standards grounding and bonding equipment and each rod should be used with minimum 50kg earth enhancing compund that should be ROHS tested and have passed leaching sulpher, corrosion, resisitivity test shall be less than 0.05lhm mtr and international standard for earth enhancement compound by NABL acredited laboratory and each rod should be interconnected with 8mm dia copper clad steel conductor at the distance of 3m to make a shape of traingle with top of the bore finished with 40mm thick PCC in 1:2:4 type B-1, 75mm thick PCC in 1:4:8 type D-2 and back fill/JAM compund shall be covered with advanced polymer pit cover of 30x30mm size including taking out old unserviceable earthing complete all as specified and as directed
Notes for item No. 226: (i) The earthing shall comply to IS 3043, UL 467, BS/EN50164-7 (ii) The earth resistance shall be less than 01Ohm. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect (iii) To obtain earth resistance less than 01Ohm, if a combination two or more earthings are to be inter-connected or the length of the electrode/s is/are to be increased it shall be measured and paid as one earthing only (iv) Testing of earthing shall be carried out in presence of Departmental rep and requisite test reports shall be submitted (v) Cost of all excavation & earthwork required shall be deemed to be included in the quoted rate
M&L for earthing using GI earthing strip 25x4mm with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 25x4mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
M&L for earthing with galvanised steel earth wire electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth wire 4sqmm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
Notes for serial item Nos. 228 & 229: (i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
The Rahul Vig
M/S Sonu Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .