Executive Engineer
Executive Engineer Mechanical DivisionAgartala
Providing Installation Testing and Commissioning of split type air conditioning system in Cabinet Section Room No 1210 2nd floor Secretariat Building Agartala
2025_CEPWD_60543_1
4_EE_DNIeT_MECH DIVN_AGT_2025-26
Open Tender
Electrical Works
Works
60 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹4,035
3 May 2025
23 Apr 2025
3 May 2025
23 Apr 2025
3 May 2025
23 Apr 2025
Amount
Supply, Installation, Testing and Commissioning of ISO certified company made Air cooled High Wall Split type Air Conditioners with latest star rating system as per BEE amended up to date complete with Indoor unit (IDU), Outdoor unit (ODU), surface/ concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr. (IDU to ODU), R-32/ R-410/ R-407 Green refrigerant, wireless remote control, suitable for working between 180-260 V with low & high voltage cut-off and 50 Hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ rotary compressor. The system shall be able to deliver 100 % of the rated capacity upto 43 Degree celcius. Minimum 5-Year OEM warranty of both compressor & PCB. NABL accredited as per IS/ISO/IEC 17025 standards/ CPRI/ ERDA lab testing reports as per IS-1391 (Part-2) 2018 with OEM certificate must be submitted to Engineer-in-charge, complete as per CPWD specification, as per the terms & condition and as directed by Engineer-in-charge.
2.0 TR split type high wall AC machine (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 Btu/hr or 7000 watt)
Standard installation, testing and commissioning of 2.0 TR split including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 1.5/2.0 as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units as per direction of the Engineer-in-charge.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
stage.html
html • 0.02 MB
finance_61577.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .