Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹27.9 CrAccepted-AOC BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | ₹27.9 Cr Quoted ₹28.0 Cr | l1 | Accepted-AOC Lowest Bidder |
| 2 | l2₹29.7 CrRejected-AOC | ₹29.7 Cr | l2 | Rejected-AOC Not lowest bidder |
| 3 | L3₹31.3 CrRejected-AOC GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | ₹31.3 Cr | L3 | Rejected-AOC Not lowest bidder |
| 4 | L4₹31.4 CrRejected-AOC NOT SPECIFIED | ₹31.4 Cr | L4 | Rejected-AOC Not lowest bidder |
| 5 | L5₹32.0 CrRejected-AOC | ₹32.0 Cr | L5 | Rejected-AOC Not lowest bidder |
Tender Value
₹30.4 Cr
EMD Value
₹15 L
Closing Date
24 Mar 2025, 6:00 pmClosed
Chief Engineer Chennai Zone
Chief Engineer Chennai Zone, Island Grounds, Anna Salai, Chennai 600009
PROVN OF DEFICIENT MD ACCN FOR JCOS AND OR AT KANNUR MIL STN
2025_MES_696550_1
85176/E8
Open Tender
Civil Works
730 days
Kannur
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
Garrison Engineer (Army) Trivandrum
₹15 L
Yes
7 Jul 2025
5 Feb 2025
1 Apr 2025
5 Feb 2025
24 Mar 2025
9 Mar 2025
5 Feb 2025 - 25 Feb 2025
Amount
Lumpsum price worked out by the tenderer for BUILDINGS AND STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for PROTECTIVE WORK as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for DEMOLITION as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for ROAD, PATH, HARDSTANDING AND CULVERT as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for AREA DRAINAGE AND RCC OPEN WELL as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for COMPOUND WALL/ FENCING GATE as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for LIFT as listed in Schedule ‘A’ Part-XIII
Lumpsum price worked out by the tenderer for FIRE FIGHTING as listed in Schedule ‘A’ Part-XIV
Lumpsum price worked out by the tenderer for LIGHTENING PROTECTION as listed in Schedule ‘A’ Part-XV
SCHEDULE 'A' PART XVI (DIESEL GENERATOR SET) & SCHEDULE 'A' PART XVII ( OTHER MISCELLANEOUS ITEMS ) Note: SCHEDULE 'A' PART XVI & XVII is not pre-priced by MES
INTERNAL ELECTRIC SUPPLY
Material and labour for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FR-LSH unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall / ceiling including continous earth wire 1.5 Sqmm PVC insulated FR-LSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in walls and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc complete all as specified for the following:- One light / fan point controlled by one switch.
One three pin switch socket 6 Amps outlet on independent board.
One three pin switch socket 6 Amps outlet on same board.
One light point controlled by two nos of two way switches.
One bell point controlled by one bell push.
All as per item No 16 here in before but with cable 4 sqmm multi stranded copper FR-LSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 4 sqmm copper stranded conductor FR-LSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified
Supply and fix power module 240V, 20A complete with 4 module metal flush box, cover plate, Starter, Plug & Socket all as directed
Supplying and installing 100 mm width x 50 mm depth x 1.6 mm thickness of Perforated Hot Dipped Galvanised lron cable tray with cover, perforation not more than 17.5%, in convenient sections, joined with connectors, bends, tees, reducer etc. including G.l. bolts & nuts, etc as required.
S&F exhaust fan, steel body AC single Phase. 230V of size 250 mm sweep with, blades, and frame and louvers complete all as specified and directed by engineer-in-charge.
S & F LED Bulb 9W B22, BEE star rated with minimum 3 star rating
S & F Decorative Wall Bracket Light, input voltage range 140-270 V, input frequency 50-60 Hz made up of poly carbonate, suitable for 9 W LED lamp B22 base complete all as specified and directed by the engineer-in-charge.
Supply,install, commission and testing cubical type LT meter box indoor , manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 2.0 mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be suitable to accomodate 01 No TPN DB 4 ways and 04 Nos Single phase smart meters.
Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less' than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR-2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and adequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection complete all as specified and as directed.
Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI wire length up to 7.50M will be measured as one unit)
(EXTERNAL WATER SUPPLY )
Supply, lay and testing ductile iron pipes with spigot and socket ends cast calss K-9 confirming to IS 8329 with inside surface of centrifugally cast cement mortar lined suitable for rubber/lead joint 100 mm dia (4") bore including for laying level or to falls , in trenches , on the ground or on supports above ground level complete all as specified. (Note : Earth excavation shall be measured and paid seperately under respective item of Sch 'A' part XI)
Supply ,install , test and commission of Centrifugal electrically driven self priming monoblock pump set with cast iron impeller capable of pumping 7.1 LPS at 40 Mtr head, squirrel cage TEFC induction motor 3 phase, 415V AC,50 Hz s coupled on common base chanel including necessary PCC foundation works, nuts and bolts, suitable size copper cable from starter to motor through PVC flexible pipe , suitable size of suction pipe not less than 20 feet or as reqd at site , air release valve, foot valve on suction side complete all as directed and specified (Note : Rate quoted shall be inclusive of cost of necessary foundation and suitable electric connection form starter panel to pump set)
Supply ,install , test and commission of open well submersible pump set Horizontal type, multistage with cast iron impeller capable of pumping 6.2 LPS at 34 Mtr head, coupled to submersible electric driven motor, 3 phase, 415V AC,50 Hz including provision of non-return valve both ends screwed of size 75mm dia fixed to 75mm dia bore of pipe including connecting to 3 core copper conductor submersible cable (water proof) of suitable size complete all as specified and as directed.
M/L for Earthing of machinery/equipment Installed at pump house/substation complete using galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 32x 6 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all as shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI strip length up to 7.50M will be measured as one unit)
M&L for construction of valve chamber 900x900x900 mm depth with PCC foundation in the ratio 1:4:8 brick work cement mortar in the ratio 1:6 using of class B bricks , PCC 1:2:4 type B0 using 12.5 mm aggregate at the top , plastering 15 mm thick in the ratio 1:4 including MS sheet cover 3mm thick with angle iron frame 50x50x6mm locking arrengement complete with painting on steel surface with two coatsof synthetic enameeled paint over one coat of red oxide paint all as specified and directed . (Earth work shall be measured and paid seperetely in the respective items of Schedule 'A' part XI)
Supplying and fixing water proof flat submersible copper conductor cable 6 sqmm, 3 core, 1100 volts grade including nylon binding wire and accessories to clamp with column pipe at places to column pipe complete all as specified and directed Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of Indoor type PLC (Programmable Logic Controller) based Slave Monitoring / Annunciating Control Panel made out of 1.6mm thick CRCA sheet for control and monitoring of 02 Nos centrifugal pumps , 06 Nos Motorized butterfly valves, 02 nos. magnetic level sensors, 01 Nos Ultra Sonic Level Sensor, 03 Nos valves for priming motorised valves, 02 Nos Pressure transmitters , 02 Nos air release valves & the panel shall consist of the following equipments; (a) PLC with suitable Digital and analog Inputs / outputs, expansion modules, RTC etc. (b) HMI -7" (c) Transformer with regulated output voltage of 230V, +/-5%, (d)SMPS of 6 A rating,
(e) Set of Control Relays and suitable MCB (f) audio visual generator etc. (g) Suitable No. of LED Indicators for easy visualisation (h) Selecetor Swtiches (k) Push Buttons / Illuminated Push Buttons (l) 0.5 sqmm multistarnded internal wiring with ferruling and suitable lugs. (m) GPRS communication Modem along with suitable external antenna of suitable gain, patch chord and mounting accessories with following specification. Make of Control Panel : Rkom Solutions / Integrated Control Systems / Dynatek India Pvt Ltd Location : Pump House
Supply, Installation, Testing and Commissioning of Outdoor type PLC (Programmable Logic Controller) based Slave Monitoring / Annunciating Control Panel made out of 1.6mm thick CRCA sheet for control and monitoring of OHT, 04 Nos Motorized butterfly valves, 08 Nos Magnetic Level Sensor & the panel shall consist of the following equipments; (a) PLC with suitable Digital and analog Inputs / outputs, expansion modules, RTC etc., (b)7" HMI (c) Transformer with regulated output voltage of 230V +/- 5%, (d)SMPS of 15 A rating,
(e) Set of Control Relays and suitable MCB (f) audio visual generator etc. (g) Suitable No. of LED Indicators for easy visualisation (h) Selecetor Swtiches (j) Push Buttons / Illuminated Push Buttons (k) 0.5 sqmm multistarnded internal wiring with ferruling and suitable lugs. (l) GPRS communication Modem along with suitable external antenna of suitable gain, patch chord and mounting accessories. Make of Control Panel : Rkom Solutions / Integrated Control Systems / Dynatek India Pvt Ltd Location 1 : 8 Floor Bldg Location 1 : 7 Floor Bldg
Supply, Installation, Testing and Commissioning of rust proof maintenance free magnetic sensors. Make: Rkom/Mahalaxmi/Techtrol
Supply, Installation, Testing and Commissioning of Motor Actuated Butterfly valve with the following specifications including all accessories as required :- (a) Valve size: 50 mm dia. (b) Designed line pressure: 10 kg/sq cm. (c) Operating Angle: 90 degrees (d) Disc Material: C.I. with nylon coating (e) Limit switches: 02 nos. for open and close (f) Type: Direct mounting / Indirect Mounting Actuator Make : Rkom / ICS / Realtork / Emtork Butterfly Valve Make : L&T / Normex / Leader / Zoloto
Supply, Installation Testing & Commissioning of pressure transmitter with following specification: (a) Power supply: 10-36 V DC (b) Process connection: G ½ “ (c) Enclosure: whether proof IP 65 (d) Process temperature: -30 to 120 celcius (e) Accuracy:1 % Make: DANFOSS/ INDFOSS/ Siemens
Supply, Installation Testing & Commissioning of motorized valve suitable for 25mm GI pipe for priming of pump including suitable bypass with necessary GI fittings with following specifications: (a) Size: 25 mm (b) Material : SS/ Forged Brass/ Cast Bronze (c) Pressure rating: 6 kg / sq. cm. Make: Avcon/ Rotox/ JOHNSON CONTROL
Supply, Installation Testing & Commissioning of solenoid valve suitable for 10 mm GI pipe for priming of pump including bypass arrangement using 10 mm. gate / ball valve with necessary GI fittings with following specifications: (a) Size: 10 mm (b) Material : SS/ Forged Brass/ Cast Bronze (c) Type: Pilot operated, diaphragm type / direct acting type. (d) Pressure rating: 6 kg / sq. cm. (e) Normally closed Make: Avcon/ Rotox/ JOHNSON CONTROL
Supply, Installing,Testing and Commissioning of Ultrasonic Level Transmitter Range : 0-5 metres , Accuracy : 0.5 % minimum, Supply Voltage : 24V dc, Output : 4-20 mA Make: NIVELCO/ E+H/ SIEMENS / BANNER / KROHNE MARSHAL
Supply,laying,testing and commissioning of 2C x 1.5 sq.mm cable of 1.1KV Grade XLPE ,insulated,sheathed steel armoured with Copper Conductor Power Cables.The rates quoted for laying shall include laying of cables on surface with saddles,screws etc. including material and labour charges etc complete .
Supply,laying,testing and commissioning of 4C x 1.5 sq.mm cable of 1.1KV Grade XLPE ,insulated,sheathed steel armoured with Copper Conductor Power Cables.The rates quoted for laying shall include laying of cables on surface with saddles,screws etc. including material and labour charges etc complete .
Supply,laying,testing and commissioning of 6C x 1.5 sq.mm cable of 1.1KV Grade XLPE ,insulated,sheathed steel armoured with Copper Conductor Power Cables.The rates quoted for laying shall include laying of cables on surface with saddles,screws etc. including material and labour charges etc complete .
Supplying and fixing 5 pair 0.5 mm dia copper armoured communication cable insulated,sheathed steel armoured with Copper Conductor Power Cables.The rates quoted for laying shall include laying of cables on surface with saddles,screws etc. including material and labour charges etc complete .
(EXTERNAL ELECTRIC SUPPLY )
S&F pole mounted FRP box weather proof type with hinged type doorof white colour of size 250x181x98 mm with 4 way PVC connector including 1 No MCB SP 6 amps and with suitable clamping arrangements for street light fittings all as specified and directed by Engr-in-charge.
S&F LED All in One solar street light fitting 36 watt luminiare output (120 Lumen/Watt) in built Lithium Ferro Phosphate battery 12.8V & 27 Ah, Mono Crystalline solar panel 60W &18V, PIR Sensor with Colour Temperature 6000K, MPPT charge controller with dusk down sensor, 2 days autonomy with dimming profile complete incuding galvanised Octagonal steel pole of 6 mtr length, 3 mm thickness, 70 mm top & 130 mm bottom with base plate 200x200x12 mm and 64 micron, M16x600/EN 8 grade foundaction bolt, 1 mtr arm for light fixing & PCC foundation.
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and direc ted with the following switch gears: - ( Main LT Panel)
(i) MCCB 4 pole 500 Amps 35 KA - 01 No (Incoming) (ii) MCCB 4 pole 250 Amps 25 KA - 01No (Outgoing for APFC) (iii) MCCB 4 pole 200 Amps 25 KA - 02 Nos (Outgoing for Bldgs) (iv) MCCB 4 pole 160 Amps 25 KA - 01No (Outgoing for AMF) (v) LED phase indication lamp for 3 phase- 01 No (vi) Aluminium bus bar 3 phase & neutral of suitable capacity.
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and direc ted with the following switch gears:: - ( DG Panel)
(i) MCCB 4 pole 160 amps 35 KA - 01 No (Incoming) (ii) MCCB 4 pole 40 Amps 25 KA - 07 Nos (Outgoing for Bldg) (iii ) MCB 4 pole 20 Amps 15 KA - 01No street lights (iv) Timer with contactor- 01 Set (vi) LED phase indication lamp for 3 phase- 01 No (vi) Aluminium bus bar 3 phase & neutral of suitable capacity. (vii) Timer switch three phase with contactor 16/20 amp (for JCOs Street Lt) - 01 Nos
Boring of holes under road, pavement, hard standing by trenchless technology sing ultra sonding techinques and necessary machines including HDPE pipes of 150 mm dia suitable for 0.4MPA working pressure complete all as specified and directed.
Supplying, installing on wall or suspension on ceiling, testing and commissioning of 315 A capacity Air Insulated Compact Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply as per IEC 60439 (1&2) & IS 8623 (1&2) with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A sq cm at nominal current rating, necessary joints, elbow joints & expansion joints, fire barrier at each floor, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.l. clamping brackets, suspenders angle iron bracket, steel fasteners, connecting to earthing system etc asrequired.
S & F end cover for Air Insulated Compact Type Bus Trunking as mentioned in Sl Item No. 44 here-in-before
Supplying, installation, testing & commisioning of 315 Amp, Isc =25kA for 1 sec End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with and including provision of MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
Supplying, installation, testing & commisioning of 100 Amp, Isc=15kA for 1 sec capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains fora use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with and including provision of MCCB complete etc. as required
Supplying and installing 200 mm width x 50 mm depth x 1.6 mm thickness size of Perforated Hot Dipped Galvanised lron cable tray with cover, perforation not more than 17.5%, in convenient sections, joined with connectors, bends, tees, reducer etc. including G.l. bolts & nuts, etc as required
S&F cable route indicator Oval shape 200x150x6mm cast iron fixed on 25x25xx6mm angle iron incuding marking of HT/LT UG Cable duly painted and grouted in PCC
M & L for Painting of HT concrete pole of complete lenght, by applying one coat of white cement based paint after scraping / brushing and cleaning the Algae on pole and cross arms and a coat of white synthetic enamel painting to pole upto 1.5 mtr from ground level shall be painted by alternate layer of black and Yellow enamel paint (30 cms apart) and Two coat of aluminium painting shall be done on Cross arm and bracing, nut, bolts and washers etc after prep of surfaces all as directed by Engr in charge. Note - one 2 pole structure measured as one job inclusive of HT poles and cross arms complete.
M & L for Painting of LT concrete pole of complete lenght, by applying one coat of white cement based paint after scraping / brushing and cleaning the Algae on pole and cross arms and a coat of white synthetic enamel painting to pole upto 1.5 mtr from ground level shall be painted by alternate layer of black and Yellow enamel paint (30 cms apart) and Two coat of aluminium painting shall be done on Cross arm and bracing, nut, bolts and washers etc after prep of surfaces all as directed by Engr in charge. Note - one pole measured as one job inclusive of LT poles and cross arms complete.
S&Fing modular TV socket including modular metal flush box and modular white cover plate all as specified
DIESEL GENERATOR SET - (REFER SCHEDULE 'A' PART XVI FOR DETAILS)
Supply, installation, testing and commissioning of 100 KVA (The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of 100 KVA or equivalent, developing suitably derated of Minimum BHP @ 1500 RPM, Liquid Cooled, electric start coupled to alternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, sound proof canopy, integral fuel tank with battery and leads and accessories complete in all respect with emission control device to control the PM within range as prescribed by latest NGT/ norms published vide GSR 804 (E) dt 03 Nov 2022 of GoI & updated till date on procurement of CPCB and CPCB approved acoustic enclosure suitable for ambient condition at Kannur including required PCC foundation as per manufacturers specification and confrrming to conditions under IS 10004722/1460 BS 5514/2613/ 5000 ISO 8526/3046 all as specified in Item No.1 of Schedule 'A' Part -XVI on Serial Page No. 54 to 57 of tender documents
(FIRE FIGHTING )
S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to he level of 3.5 kg/cm2 complete all as specified and directed by the engineer-in-charge
Supplying, erection, testing & commissioning of Cast Iron air release valve, 100 mm dia fitted on the top most point of the down comer with drain connection. The rate shall be inclusive of accessories.
M & L for Two-Wire Addressable Talkback Speaker with inbuilt driver. The Addressable Talkback speaker shall have a call button for unit activation, signaling the support control panel to indicate the caller’s location. Clear voice pickup shall be ensured within a minimum one-meter distance from the unit’s microphone and the speaker’s standing position. The unit shall be equipped with an LED that blinks in normal conditions and glows steadily upon activation. Activation can occur through the built-in push button or remotely from the control panel. Both the control panel and Talkback speaker shall continuously scan for healthiness and cable connectivity to ensure integrity compliance. The speaker shall have a capacity of 5 watts, serving both Talkback and PA functions. It shall have ABS Housing alongwith BackBox. It shall be able to produce 70 db sound at 1 mtr distance. Make: Airlight/Nitin/Agni/NotoFire
M & L for Two-Wire Addressable Speaker with LED light flash/Beacon, suitable for targeted announcements and equipped with a LED light flash (to cater to hearing-impaired occupants). The unit shall be equipped with an LED that blinks in normal conditions and glows steadily upon activation. Both the control panel and speaker unit shall continuously scan for healthiness and cable connectivity to ensure integrity compliance. The speaker must have a minimum capacity of 5 watts with max voice current of 100mA. It shall have ABS Housing alongwith BackBox. It shall be able to produce 90 db sound at 1 mtr distance. Make: Airlight/Nitin/Agni/NotoFire
M & L for Two-Wire Addressable Speaker driver Module with built-in audio amplifier and alongwith 12-15 W horn type speaker(Maximum Voice current of 300mA) for outdoor use such as parking areas, asssembly areas etc. & with the Back Box. It shall be able to produce minimum 90 db sound at 1 mtr distance. Make: Airlight/Nitin/Agni/NotoFire
M & L for Two-Wire Addressable Multisensor Heat Cum Smoke detector along with its base, with dual bi-colour LED indication for 360° viewing angle & with the following specifications:- Smoke sensitivity : 0.5 – 3.5 %obs/foot Thermal sensitivity: 20ºC to 60ºC Housing: Polycarbonate Contact Clamp: Stainless steel
M & L for Remote Repeater Panel similar to Main control Panel capable of full supervision of all inputs and network integrity, having colour touch screen display, environmental adjustment controls to maximize LCD legibility, LED status indicators (for power supply and off normal condition) Make: Airlight/ Nitin/ Agni/ NotoFire
M & L for low smoke zero halogen (LSOH) flame retardant fire alarm cable 2C x 1.5 Sq mm, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through & including concealed PVC conduit and accessories of minimum 20 mm NB and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 C to +70 °C and minimum bending radius being 6 times the over all cable diameter, RED in colour, including laying., termination and ferruling complete all as specified and directed by the engineer-in-charge
S & F of Signage having size 300 mm X 150 mm reading "EXIT" in 12.5 mm block letters in Green and white background, self illuminated properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level.These lights shall emit the maximum light required even during the electricity supply or in Black out period with high energy efficiency manufactured using superior quality Aluminium Extrusion body raw material Make: Variex, Mr safe, Matrix sign lab NOTE: EXIT Signage shall meet the following technical / operational requirements: (i) Product Material: Alluminium ALLOY Extrusion (ii) Product Finish:- Matt Black / Snow white finish after phosphochromate treatment (iii) Wattage:-5 Watt (iv)Mounting: Surface /Hanging
S & F of Signage having size of 500 mm X 500 mm, indicating the "Floor Number" in bold type and at 75 mm high numerals in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non- reflective self adhesive vinyle painted foam board, posted and maintained within each stair enclosure on every floor, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level Make: Variex / Mr. safe / Matrix sign
S & F of Signage having size of 450 MM X 150 MM reading "FIRE EXTINGUISHER" in 12.5 mm block letters in White and Red background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non- reflective self adhesive vinyle painted foam board,properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top the sign is not above 2 m from the finished floor level Make: Variex / Mr. safe / Matrix sign Lab
S & F of Signage having size of 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the "STAIRCASE" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,securely attached to the side of the stairwal door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level Make: Variex / Mr. safe / Matrix sign Lab
Supply & Installation of Light weight squeeze grip type CO2 type Fire Extinguisher of 4.5 kgs capacity with stand ,made from brand new seamless drawn steel cylinder as per IS: 7285 with ISI mark and Chief of controller of explosives approval,fitted with wheel valve as per IS: 3224 with ISI mark,with discharge hose and horn and supplied complete with initial charge as per IS: 15683 with ISI mark. Make:- Kanex/Minimax/Cease-fire/Safeguard/ Coffco/ Variex
S&F of Mechanical foam type fire extinguishers, 9 Ltr capacity, IS:15683 : 2006, complete.
S&F of Dry powder ABC stored pressure squeeze grip type fire extinguishers, 6 kg capacity, IS:15683 : 2006, filled with ABC Mono Ammonium Phosphate base powder-90 complete with discharge hose and wall mounting bracket, 2mm Mild Steel, EPDM Rubbers, Pressure Guage, which work effectively on all class of fires (A, B, C & Electrical fires) complete.
Supply & Installation of Water Stored pressure type Fire Extinguisher of 9lit capacity,fitted with discharge control valve (Squeeze grip type) CEmarked and pressure gauge, with discharge hose and open nozzle and supplied complete with initial charge as per IS:15683 with ISI mark and wall bracket. Fire Rating 2A
S&F of 4 Nos of 9 lts capacity round bottom sand /water buckets along with round bottom type , enamel painted white inside and red outside & letter fire in black outside & handle with mounting bracket along with suitable MS stand to install the buckets as per the local fire standards
LIGHTENING PROTECTION
Supply, Installation, Testing and Commissioning of aviation obstruction light LED type minimum 10 watts made out of die-cast aluminium alloy housing,IP-65 with built in circuits, junction boxes for installing on top/highest portion of Bldg consisting of (S+7) & (S+8) floors complete with all connected accessories such as including all necessary cables, contactors/timer switches, controls and connections etc as per requirement and as specified . The minimum size of cable shall be XLPE, armoured aluminium conductor of not less than 4.0 sq.mm cross- section. It can be charged from Lift electric panel.
(SEWAGE DISPOSAL)
S & F conventional type LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and as directed.
M&L for DWCPE (SN8) 180(OD)/163 (ID) mm dia pipes, laid and jointed complete all as specified and directed.
(FENCING GATE)
S&F PVC coated GI Chain link fencing with 2.5mm diaGI wire and over aal 3.80mm dia of size 50mmx50mm mesh and made up in to mattress or cages, laped, wired and tied in position using GI PVC coated binding wire all as specified and as directed
Outsourcing of services for operation of 8 & 13 passengers electrically operated lifts (during first year of defects liability period) of any capacity type and make to serve any number of floors by providing services of one lift operator [Semi skilled] in each shift on all the days including sunday & holidays in two shifts including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department, complete all as specified and as directed by the Engineer-in-charge (Shift Details : 365 days x 2 shifts = 730 shifts)
Outsourcing of services for operation of 8 & 13 passengers electrically operated lifts (during second year of defects liability period)of any capacity type and make to serve any number of floors by providing services of one lift operator [Semi skilled] in each shift on all the days including sunday & holidays in two shifts including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department, complete all as specified and as directed by the Engineer-in-charge (Shift Details : 365 days x 2 shifts = 730 shifts)
Outsourcing of services for operaion of 8 & 13 passengers electrically operated lifts (during first year after completion of defects liability period) of any capacity type and make to serve any number of floors by providing services of one lift operator [Semi skilled] in each shift on all the days including sunday & holidays in two shifts including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department, complete all as specified and as directed by the Engineer-in-charge (Shift Details : 365 days x 2 shifts = 730 shifts)
Outsourcing of services for operation of 8 & 13 passengers electrically operated lifts (during second year after completion of defects liability period)of any capacity type and make to serve any number of floors by providing services of one lift operator [Semi skilled] in each shift on all the days including sunday & holidays in two shifts including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department, complete all as specified and as directed by the Engineer-in-charge (Shift Details : 365 days x 2 shifts = 730 shifts)
Outsourcing of services for operation of 8 & 13 passengers electrically operated lifts (during third year after completion of defects liability period) of any capacity type and make to serve any number of floors by providing services of one lift operator [Semi skilled] in each shift on all the days including sunday & holidays in two shifts including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department, complete all as specified and as directed by the Engineer-in-charge (Shift Details : 365 days x 2 shifts = 730 shifts)
Notes for BOQ Sl Nos. 85 to 89 (OUTSOURCING SERVICES FOR LIFT) : (i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge. (ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 5 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair /replacement of perished/ unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors.
(viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc. (ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same. (xi) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. "Name of the firm and designation" on front and on the back of the T-shirt along with protective clothing/ gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes.
(xii) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.
(xiii) The rate quoted by the bidders shall be deemed to be including Basic rate [Minimum Wages as notified by Government of India/ State Government/ Local body, which ever is higher], employers contribution towardsEmployees Provident Fund (EPF) liability, contribution towards Employees State Insurance Corporation (ESIC), contribution towards Bonus. Overhead and profit and labour welfare cess (LWC) as applicable depending upon the manpower requirement. This will create onus on the Bidders to applicable depending upon the manpowwer requirement. This will create onus on the bidders to ascertain the relevant rates and quote accordingly. The rates quoted shall be inclusive of all taxes, cess, levies are applicable including GST. DETAILS OF LIFT : (i) 8 Passenger Lift -01 / 13 Passenger Lift - 01 No (Total - 2 Nos) to Serve upto (S + 7 Floors JCO Tower) (ii) 8 Passenger Lift - 01 No / 13 Passenger Lift -01 No. (Total 02 Nos) to Serve upto (S + 8 Floors OR Tower) Note: The Manpower deployed shall be changed for every 11 months period. The rate quoted deemed to be inclusive for the same.
Comprehensive maintenance of Electrically Operated lifts 4 Numbers (1 No. 08 passenger lifts (544 Kgs) to serve (S+7 Floors) for JCOs Md Accn, 1 No. 08 passenger lifts (544 Kgs) to serve (S+8 Floors) for ORs Md Accn, 01 No of 13 passenger lifts (884 Kgs) to serve (S+7 Floors) JCOs Md Accn and 01 No of 13 passenger lifts (884 Kgs) to serve (S+8 Floors) ORs Md Accn including ARD and all connected components of lift during Third year after the date of completion of Phase-I all as specified and directed
Comprehensive maintenance of Electrically Operated lifts 4 Numbers (1 No. 08 passenger lifts (544 Kgs) to serve (S+7 Floors) for JCOs Md Accn, 1 No. 08 passenger lifts (544 Kgs) to serve (S+8 Floors) for ORs Md Accn, 01 No of 13 passenger lifts (884 Kgs) to serve (S+7 Floors) JCOs Md Accn and 01 No of 13 passenger lifts (884 Kgs) to serve (S+8 Floors) ORs Md Accn including ARD and all connected components of lift during Fourth year after the date of completion of Phase-I all as specified and directed
Comprehensive maintenance of Electrically Operated lifts 4 Numbers (1 No. 08 passenger lifts (544 Kgs) to serve (S+7 Floors) for JCOs Md Accn, 1 No. 08 passenger lifts (544 Kgs) to serve (S+8 Floors) for ORs Md Accn, 01 No of 13 passenger lifts (884 Kgs) to serve (S+7 Floors) JCOs Md Accn and 01 No of 13 passenger lifts (884 Kgs) to serve (S+8 Floors) ORs Md Accn including ARD and all connected components of lift during Fifth year after the date of completion of Phase-I all as specified and directed
(iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (iv)Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engineer-in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM. (vii) Maintaining the performance characteristics of the equpiments as originally designated and installed by manufacture. A reasonable stock of genuine and original spare parts of replacement is to be maintained so that these are made available at the time of breakdown. Any replacement of spares should be with rewand of equilavalent type or higher of same make. All the replaced parts shall conorm to relevant IS codes or Kerala lifts Act and Rules made there under:- (viii) Responsive item for maintenace of items covered under AMC will be 24 hours. In the event of unable to attend call or provide service within the stipulated time period, penalty liable as per contract.
Supply, lay/ spread in trenches riddled sand for cushioning of cable to the full width of excavated trench, 8cm thick before laying cable and 15cm thick above the cable, gently punned down after stretching and testing of cable on transformer yard, etc., complete all as specified and as directed. Note : Punned thickness will only be considered for payment.
Kurian And Varghese (BID ID -3269463)
VIJAY CONSTRUCTIONS (BID ID -3261841)
United Sales Corporation (BID ID -3259814)
CREATIVE BUILDERS (BID ID -3263908)
Crescent Construction Company (BID ID -3269442)
S.N. Constructions (BID ID -3269529)
SHAIJAL T M (BID ID -3265457)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid